1.0 2022-05-31 Drawings Task1-Ph2 HH Renov.pdf
PDF 8 MB Posted
- Attached to
- Repair USDA Headhouse #2 Marucci Center
- Solicitation number
- 12305B23R0005
About this file
This is a request for quotes from the USDA Agricultural Research Service for construction services to repair a USDA headhouse building located in Chatsworth, New Jersey.
The project includes repair and renovation of the existing headhouse building including structural, mechanical, electrical, and plumbing work. Drawings and specifications are provided with the solicitation. Interested vendors must be registered in SAM.gov and follow submission instructions in the solicitation. The anticipated award is a firm fixed-price contract.
The evaluation will consider past performance, technical capability, and price using a lowest price technically acceptable process. The period of performance is 270 days from notice to proceed. Payment and performance bonds are required for awards over $150,000. A site visit is scheduled and questions must be submitted in writing. The government intends to make award without discussions but reserves the right to conduct discussions if in its best interest.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A3 Q and A 1 Chatsworth Headhouse.docx | DOCX document | |
| A3 12305B23R0005.pdf | ||
| A2 12305B23R0005.pdf | ||
| A1 12305B23R0005.pdf | ||
| 19.2 12305B23R0005.pdf | ||
| 1.3 SOW 9NOV2022 Chatsworth HH2 Repair.pdf | ||
| 1.4 Specifications Task 1 - Ph2 HH Renov.pdf | ||
| 1.11 Burlington WD.pdf | ||
| 19.0 Prov Clauses - HH Reno.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP LOCATION MAP PROJECT SHEET LIST
TM
1415 ELLIOT PLACE NW, SUITE 100,
WASHINGTON, DC 20007
P: 202-393-1523
UNITED STATES DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
PHILLIP E. MARUCCI CENTER FOR BLUEBERRY AND CRANBERRY RESEARCH
REPAIR USDA HEADHOUSE #2, PHASE 2, TASK 1, ELECTRICAL UPGRADE
125A LAKE OSWEGO RD., CHATSWORTH, NJ
CONTRACT #: AG-32SD-C15-0066
TASK ORDER #: 12305B20F0193
USDA JOB #: FY21 NEA UPL-8
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 3:26:54 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\23-SAG20056.13_M\15- Task 1 Ph 2 HH CAD\20056.13_PH2_CS-001.dwg Save Date: 05/25/2022 02:11 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
CS001
COVER SHEET
PROJECT DESCRIPTION
PHASE 2, TASK 1 CONSISTS OF ARCHITECTURAL, STRUCTURAL,
MECHANICAL, ELECTRICAL, AND PLUMBING RENOVATIONS TO
THE HEADHOUSE #2 BUILDING. THESE RENOVATIONS INCLUDE
BUT ARE NOT LIMITED TO STRUCTURAL SLAB UNDERPINNING,
NEW FLOORING, CEILING, FINISHES, INSULATION, SIDING, AND A
NEW ROOF TRUSS. A NEW HVAC SYSTEM WILL BE INSTALLED
ALONG WITH PLUMBING UPGRADES, AND NEW ELECTRICAL
OUTLETS.
NJ UCC REQUIRED CODES
1. GENERAL PROVISIONS (NJAC 5:23-1)
2. ADMINISTRATION AND ENFORCEMENT (NJAC 5:23-2)
3. SUBCODES (NJAC 5:23-3)
4. REHABILITATION SUBCODE (NJAC 5:23-6)
4.1. THIS PROJECT CLASSIFIES AS A RENOVATION (NJAC
5:23-6.6)
LOCATION OF PROJECT,
HEADHOUSE #2 AND
USDA GREENHOUSE
LOCATION OF PROJECT,
35 MILES FROM ATLANTIC CITY
ADMINISTRATION CENTER
CS SHEET 01 OF 01
PROJECT DRAWING LIST
SHEET DRAWING TITLE
1 CS001 COVER SHEET
2 A001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
3 A101 DEMOLITION PLAN
4 A102 NEW CONSTRUCTION
5 A103 BUILDING ELEVATIONS AND SECTIONS
6 A104 ROOF DEMOLITION AND NEW CONSTRUCTION
7 A105 WALL SECTIONS
8 A401 DOOR AND FINISH SCHEDULE AND DETAILS
9 M001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
10 MD101 MECHANICAL DEMOLITION
11 M101 MECHANICAL NEW WORK
12 M601 MECHANICAL SCHEDULES
13 M701 MECHANICAL DETAILS
14 P001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
15 P101 PLUMBING DEMOLITION & NEW WORK
16 P501 PLUMBING DETAILS
17 E001 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
18 ED101 ELECTRICAL DEMOLITION
19 E101 ELECTRICAL LIGHTING
20 E201 ELECTRICAL POWER
21 E501 ELECTRICAL POWER RISER DIAGRAM AND SCHEDULES
22 E701 ELECTRICAL DETAILS
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
AutoCAD SHX Text
ABBREVIATIONS
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:00:59 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A0.01.dwg Save Date: 05/31/2022 04:00 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A001
GENERAL NOTES,
SYMBOLS AND
ABBREVIATIONS
A SHEET 01 OF 07
GENERAL NOTES SYMBOLS
1. THESE DOCUMENTS HAVE BEEN PREPARED TO ADHERE TO THE 2014 INTERNATIONAL BUILDING CODE, INCLUDING ITS ADOPTED REFERENCES, STANDARDS SUPPLEMENTS, THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR INSURING THAT THEIR WORK ADHERES THERE TO, AND TO ALL APPLICABLE REGULATIONS AND ORDINANCES.
2. THE CONSTRUCTION DOCUMENTS ARE COMPOSED OF THE CONSTRUCTION DRAWINGS.
3. THESE DRAWINGS ARE DIAGRAMMATIC ONLY, ESTABLISHING RELATIONSHIP AND DIMENSIONAL INTENTS. DO NOT SCALE THE DRAWINGS.
EACH SUBCONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS BEFORE BEGINNING THEIR WORK. ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS, OR ANY AMBIGUITIES OR INCONSISTENCIES CONTAINED THEREIN, SHALL BE REPORTED TO THE PROJECT MANAGER AT THE EARLIEST OPPORTUNITY, AND A SUITABLE RESOLUTION ESTABLISHED PRIOR TO THE SUBMITTAL OF BIDS AND THE BEGINNING OF THE AFFECTED WORK. WORK THAT PROCEEDS IN VIOLATION OF THIS PRINCIPLE IS ENTIRELY AT THE CONTRACTOR'S OWN RISK AND THE COSTS OF ANY CHANGES REQUIRED BY THE OWNER TO
SUITABLY MODIFY SUCH WORK SHALL BE BORNE SOLELY BY THE CONTRACTOR.
4. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE LEGALLY REGISTERED AND LICENSED TO COMPLETE THEIR WORK IN THE STATE OF NEW JERSEY. ALL CONTRACTORS SHALL CARRY WORKMAN'S COMPENSATION INSURANCE AND ALL OTHER
INSURANCES, AS REQUIRED BY LAW, AND AS OTHERWISE INDICATED BY THE OWNER.
5. EACH CONTRACTOR SHALL FURNISH ALL MATERIALS, LABOR AND EQUIPMENT REQUIRED FOR THE FULL PERFORMANCE OF THEIR WORK, UNLESS SPECIFICALLY NOTED OTHERWISE. ALL WORK SHALL BE ACHIEVED IN A GOOD WORKMANLIKE STANDARD OF CARE. EACH TRADE SHALL AFFORD ALL OTHER TRADES EVERY REASONABLE OPPORTUNITY FOR THE INSTALLATION OF THEIR WORK. ALL SUBCONTRACTORS SHALL COORDINATE THEIR WORK WITH ALL ADJACENT TRADES SO AS TO FACILITATE THE GENERAL PROGRESS OF THE WORK. ANY WORK TO BE COMPLETED OR REVISITED AFTER THE CERTIFICATE OF SUBSTANTIAL COMPLETION SHALL BE
COORDINATED WITH THE PROJECT MANAGER PRIOR TO SUCH WORK BEING DONE.
6. NO PROVISION IN THE CONTRACT DOCUMENTS, NOR FINAL PAYMENT, SHALL RELIEVE THE CONTRACTOR OR SUBCONTRACTORS OF THE RESPONSIBILITY FOR NEGLIGENCE, FAULTY MATERIALS OR POOR WORKMANSHIP. UPON WRITTEN NOTICE, THE CONTRACTOR SHALL REMEDY ANY DEFECTS AND PAY ALL EXPENSES FOR ANY OTHER DAMAGE TO OTHER WORK RESULTING THEREFROM. ALL WORK IS TO BE GUARANTEED FOR THE PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE, EXCEPT FOR EXTENDED DATES AS OTHERWISE
DEFINED IN THE CONTRACT DOCUMENTS.
7. THE CONTRACTOR SHALL COORDINATE WITH THE PROJECT MANAGER ALL STAGING OF THE WORK AND SHALL COORDINATE, 14 DAYS IN ADVANCE OF ANY INTERRUPTIONS IN THE NORMAL OPERATION OF THE BUILDING (ELECTRICAL, MECHANICAL, PLUMBING, ETC..).
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND DISPOSAL OF ALL CONSTRUCTION DEBRIS AND REFUSE ON A DAILY
BASIS AND SHALL PAY ALL FEES INCURRED THEREBY.
9. NO SUBSTITUTIONS SHALL BE ALLOWED IN BASE BID. ALL SUBSTITUTIONS MUST BE REVIEWED AND APPROVED BY THE PROJECT
MANAGER.
10. THE OWNER RESERVES THE RIGHT TO REJECT MATERIAL AND OR WORK THAT IS NOT IN STRICT ACCORDANCE WITH THE CONTRACT
DOCUMENTS.
11. ADJACENT AREAS TO REMAIN IN OPERATION DURING CONSTRUCTION, PROTECT THESE AREAS, EQUIPMENT AND PERSONNEL FROM
DAMAGE/DANGER AND PROVIDE DUST PROTECTION BARRIERS DURING CONSTRUCTION.
12. PROTECT AND REPAIR ALL AREAS AFFECTED BY THE CONSTRUCTION AS REQUIRED TO MAINTAIN THEIR EXISTING APPEARANCE, UNLESS
NOTED OTHERWISE.
13. CONTRACTOR TO SUPPLY SHOP DRAWINGS TO THE DESIGN TEAM FOR APPROVAL. SHOP DRAWINGS TO INCLUDE DIMENSIONS AND
NOTATION OF COORDINATION
BASIS OF DESIGN
WIND 120 MHP, RISK CAT II, EXPOSURE C, Q =26.63 PSF ICE 1",SNOW 20 PSF,RAIN 15'@5,89 IN/HR @60'@3,11 IN/HR CEILING 10 PSF DUE TO 4:12 PITCH AND ATTIC SPACE BEING CREATED WITH OVER 24" OF HEIGHT
- FRONT TO BACK TRUSSES @ 24" O.C.
- ANTISYMMETRIC ROOF OVERHANGS
- TRUSS LOADS:
· + 2,656 #/TRUSS GRAVITY
· -1,474 #/TRUSS UPLIFT
- WALL LOADS
· + 25.6 PSF
· - 21.3 PSF
- WALL UPLIFT
· PLYWOOD SIZE AND FASTENED DEFINED
· UPLIFT STRAP FOR TRUSS DEFINED
- WALL GRAVITY
· POCKET FOOTING DEFINED TO GO UNDER THE EXISTING SLAB EDGE. FACTORY OF SAFETY OF 2 WAS USED DUE TO UNKNOWN
SOIL CONDITIONS. POCKET HAS ROUGHLY A 3" TO 4 " PLACEMENT POCKET.
· USE A 4,000 PSI 2" HOSE PUMP MIX SHOULD FLOW REAL UNDER SLAB TO ACHIEVE DESIRED COLD JOINT.
- WALL SHEAR
· NAILING PATTERN DEFINED ALONG WITH LENGTH. SEE NOTE "N" ON SHEET A102.
DETAIL NUMBER
DETAIL TITLE
DRAWING NUMBER ON WHICH DETAIL IS DRAWN
DRAWING NUMBER FROM WHICH DETAIL IS TAKEN
DETAIL NUMBER
DETAIL
DRAWING NUMBER ON WHICH DETAIL IS DRAWN
DRAWING NUMBER FROM WHICH DETAIL IS TAKEN
DETAIL NUMBER
ELEVATION
DRAWING NUMBER ON WHICH DETAIL IS DRAWN
DRAWING NUMBER FROM WHICH DETAIL IS TAKEN
DOOR NUMBER
ROOM NUMBER
SEE SCHEDULES
WINDOW NUMBER
PARTITION TYPE SEE SCHEDULES
COLUMN GRID
LINE
REVISION NUMBER
BRICK/CLAY TILE
C.M.U.
CONCRETE
EARTH
EXISTING CONDITION
GRANULAR FILL
INSULATION
METAL
PLASTER OR GROUT
PLYWOOD
WOOD ROUGH
EXISTING PARTITION TO REMAIN - SEE PLAN NOTES
EXISTING CONSTUCTION TO BE REMOVED - SEE PLAN NOTES FOR PARTIAL OR COMPLETE DEMOLITION
NEW PARTITION - SEE PLAN NOTES
EXISTING DOOR AND FRAME TO REMAIN
EXISTING DOOR AND FRAME TO BE REMOVED
NEW DOOR AND FRAME
MATERIAL DESIGNATION
WOOD FINISH
LEGEND
LAVATORY
POUNDS
LEFT HAND
LEFT HAND REVERSE
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MANHOLE
MANUFACTURER
MASONRY
MATERIAL
MAXIMUM
MECHANICAL
METAL
METER
MILLIMETER
MINIMUM
MISCELLANEOUS
MODIFICATION
MOLDING
MOUNTING
NEW OFFICE BUILDING
NOT APPLICABLE
NOT IN CONTRACT
NOT TO SCALE
NUMBER
ON CENTER
OPENING
OUTSIDE DIAMETER
PAINTED
PRESSURE TREATED
PAINTED PLASTER
PAIR
PANELBOARD
PAVEMENT
PLASTIC LAMINATE
PLATE
Plumbing
PLYWOOD
POLYVINYL CHLORIDE
POUNDS PER CUBIC
FOOT
POWER
PRECAST
PROJECT
PROPERTY
PUBLIC ACCESS
CONTROL
QUANTITY
QUARRY TILE
RAISED ACCESS
FLOOR
REFRIGERATOR
REINFORCING
RELOCATE
REQUIRED
RIGHT HAND
RIGHT HAND REVERSE
RADIUS
REFERENCE
ROOF DRAIN
ROOM
ROUGH OPENING
SCHEDULE
SECTION
SERVICE
SERVICE SINK
SHEET
SIMILAR
SOLID CORE WOOD
SPECIFICATION
SQUARE
SQUARE FOOT
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
TELEPHONE
TELEVISION
THICK
THRESHOLD
THROUGH
TREAD
TREATED
TYPICAL
URINAL
UNLESS OTHERWISE STATED
VERTICAL
VINYL TILE
VENT THROUGH ROOF
VOLTAGE, VOLTS
WATER CLOSET
WATERPROOFING
WELDED WIRE FABRIC
WITH
WITHOUT
WOODWD.
W/O W/ W.W.F.
W.P.
W.C.
V.
V.T.R.
V.T.
VERT.
UOS.
UR.
TYP.
TRT.
T.
THRU.
THRES.
THK.
T.V.
TEL.
SUSP.
STRUCT.
STL.
STOR.
STD.
S.STL.
S.F.
SQ.
SPEC.
SCWD.
SIM.
SHT.
SSK.
SER.
SEC.
SCHED.
R.O.
RM.
R.D.
REF.
R.
R.H.R.
R.H.
REQD.
RELOC.
REINF.
REFR.
R.A.F.
Q.T.
QTY.
P.A.C.
PROP.
PROJ.
PC.
PWR.
P.S.I.
P.C.F.
PVC.
PLYWD.
PLUMB.
PL.
P.LAM.
PVMT.
PNL
PR.
P.P.
PT
N.T.S.
N.I.C.
PTD.
O.D.
OPNG.
O.C.
NO.,#
N/A N.O.B.
MTG.
MLD.
MOD.
MISC.
MIN.
MM.
M.
MET.
MECH.
MAX.
MAT.
MAS.
MFG.
MH.
L.L.V.
L.L.H.
L.H.R.
LBS.
L.H.
LAV.
POUNDS PER SQUARE
INCH
ARCHITECTURAL DRAWING LIST
SHEET DRAWING TITLE
1 A0.01 GENERAL NOTES, SYMBOLS AND ABBREVIATIONS
2 A101 DEMOLITION PLAN
3 A102 NEW CONSTRUCTION
4 A103 BUILDING ELEVATIONS AND SECTIONS
5 A104 ROOF DEMOLITION AND NEW CONSTRUCTION
6 A105 WALL SECTIONS
7 A401 DOOR AND FINISH SCHEDULE AND DETAILS
ABV. ABOVE
A.D.A AMERICAN DISABILITY ACT
A.F.F. ABOVE FINISHED FLOOR
ACOUST. ACOUSTICAL
ADJ. ADJACENT
A/C AIR CONDITIONING
ALUM. ALUMINUM
A.,AMP. AMPERE
APROX. APPROXIMATE
ARCH. ARCHITECTURAL
AUTO. AUTOMATIC
BSMT. BASEMENT
BM. BEAM
BRG. BEARING
BTWN. BETWEEN
B.O.M. BILL OF MATERIALS
BLKG. BLOCKING
BTM. BOTTOM
B.T.U. BRITISH THERMAL UNIT
BLDG. BUILDING
CAB. CABINET
CAP. CAPACITY
C.I. CAST IRON
C.L. CENTER LINE
CLG. CEILING
CM. CENTIMETER
CER. CERAMIC
C.O. CLEAN OUT
CCTV. CLOSED CIRCUIT TELEVISION
CL. CLOSET
COL. COLUMN
C.A.C. COMPOUND ACCESS CONTROL
CONC. CONCRETE
C.M.U. CONCRETE MASONRY UNIT
C.D. CONDENSATE UNIT
C.COND. CONDUIT
CONSTR. CONSTRUCTION
CONT. CONTINUATION,CONTINUOUS
DEG. DEGREE
DEPT DEPARTMENT
DET. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DR. DOOR
DWL. DOWEL
DN DOWN
D.S. DOWN SPOUT
D. DRAIN
DWG. DRAWING
D.F. DRINKING FOUNTAIN
D.W. DUMB WAITER
EA. EACH
ELEC. ELECTRICAL
E.P. ELECTRICAL PANEL
ELEV. ELEVATION
EMER. EMERGENCY
EQ. EQUAL
EQUIP. EQUIPMENT
ETC. ETCETERA
EXIST EXISTING
E.O.B. EXISTING OFFICE BUILDING
EXPAN. EXPANSION
E.I.F.S. EXTERIOR INSULATION AND FINISH SYSTEM
EXTIN. EXTINGUISHER
FT. FEET, FOOT
FIN. FINISH
F.D. FIRE DAMPER
F.L.D. FLOOR DRAIN
FLUOR. FLUORESCENT
FTG. FOOTING
GAL. GALLON
GALV. GALVANIZED
GA. GAUGE
GEN. GENERATOR
GOV'T.. GOVERNMENT
G.F.E. GOVERNMENT FURNISHED EQUIPMENT
GVL. GRAVEL
GD. GROUND
GYP. BD. GYPSUM BOARD DRYWALL
HDWE. HARDWARE
HT. HEIGHT
HCWD. HOLLOW CORE WOOD
H.M. HOLLOW METAL
HOR. HORIZONTAL
IN. INCHES
INCIN. INCINERATOR
I.D. INSIDE DIAMETER
INSUL. INSULATION
I.O.B. INTERIM OFFICE BUILDING
INT. INTERIOR
INV. INVERT
J.C. JANITOR'S CLOSET
JT JOINT
K.W. KILOWATTS
KIT. KITCHEN
LAM. LAMINATE
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W1
AutoCAD SHX Text A9
AutoCAD SHX Text A8
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A5
AutoCAD SHX Text A6
AutoCAD SHX Text
AutoCAD SHX Text A2
AutoCAD SHX Text A3
AutoCAD SHX Text
AutoCAD SHX Text X
F.
1.1.
1.1.
2.
2.
1. 1. 1. 1.
4.
4.
4.
4.
6. 6. 6. 6.
7. 7.
11.
9.
9.
9.9. 12.
11.
13.
9.
4.
15.
16.
15.15.
'-7
17'-6"
5' -1
1"
5' -9
30'-1"
'-3
'-3
17'-4"
'-7
5' -8
5' -1
0"
6 666
18.
5.
5.
5.
5.
5.
17.
13.
14.
3.
14.
GREENHOUSE # 7 GREENHOUSE # 6
POTTING SHED
CORRIDOR CORRIDOR
DIRTY ROOMCLEAN ROOM
TANK ON
CONC.PAD
EXIST.TO
REMAIN
BENCH
BENCH
ELECTRICAL EQUIPMENT
EXISTING TO REMAIN
GENERATOR EXISTING
TO REMAIN
14.
5.
5.
5.
5.
10.
8.
13.
10.
14.
13.
13.
13.
11. 11.
11.
18.
11.
11.
19. 19.
19. 19.
3.
11.11.
7'-1"
'-0
7'-1"
'-0
7'-1"
'-0
7'-1"
'-0
4'-2"
7'-10"
'-2
FRAME
SHED
FRAME
SHED
FRAME
SHED
GREENHOUSE # 7 GREENHOUSE # 6
GEN
TANK ON
CONC.PAD
1/4" = 1'-0"
A.
B.
C.
D.
E.
F.
G.
H.
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:05 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-101 headhouse Phase 2 (Task 1)demolition plan.dwg Save Date: 05/27/2022 01:40 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
03 22
A101
DEMOLITION PLAN
EXISTING WORK IS BASED ON AVAILABLE DOCUMENTATION AND SURVEY SPOT
CHECKS. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND
COORDINATE WITH ENGINEER PRIOR TO PROCEEDING WITH WORK.
THE DEMOLITION PLAN IS NOT INCLUSIVE OF ALL EQUIPMENT WITHIN THE
PROJECT AREA. IT IS INTENDED TO PROVIDE THE CONTRACTOR WITH A
GENERAL KNOWLEDGE OF THE EXISTING CONDITIONS. ANY DISCREPANCIES
OR CONDITIONS NOT SHOWN ON THIS PLAN SHALL BE COORDINATED WITH
ENGINEER.
CONTRACTOR TO FIELD COORDINATE ALL REMOVAL, STORAGE, AND
DISPOSAL OF EXISTING EQUIPMENT WITH THE FACILITY. EXISTING
BUILT-IN ITEMS TO REMAIN OR SCHEDULED FOR REMOVAL AND
RELOCATION SHALL BE PROTECTED AND REINSTALLED AS SHOWN.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES, SAFETY
REGULATIONS AND THE OWNER'S REQUIREMENTS.
ALL UNUSED, EXISTING DUCT OUTLETS AND OPENINGS SHALL BE CAPPED &
SEALED.
WHERE DUCTWORK, PIPING AND EQUIPMENT ARE REMOVED, EXISTING
CONCRETE INSERTS AND STRUCTURAL ATTACHMENTS MUST ALSO BE
REMOVED.. PATCH EXISTING SURFACE TO MATCH ADJACENT.
CONTRACTOR SHALL SCHEDULE ALL WORK IN ACCORDANCE WITH THE
OWNER'S REQUIREMENTS.
ALL EXISTING CONDITIONS NOT UNDER SCOPE OF WORK SHALL REMAIN AS IS.
1. EXISTING WINDOWS TO BE REMOVED ENTIRELY.
2. REMOVE EXISTING SINK, REMOVE AND REINSTALL EXISTING INCUBATOR.
3. EXISTING PARTITIONS TO BE REMOVED ENTIRELY.
4. DEMOLISH EXISTING DOORS AND FRAMES.
5. REMOVE EXTERIOR FINISH AND INFILL EXISTING FRAMING WITH 2X4 STUDS AT 2'
O.C. WITH TOP PLATE EXTENDED TO NEW ROOF BEARING.
6. REMOVE EXISTING SOIL BINS.
7. DEMOLISH AND REMOVE EXISTING WINDOW AC UNIT. PATCH OPENING AND
REMOVE EXISTING WINDOW UNIT SUPPORT.
8. EXISTING SINK TO REMAIN FOR REUSE.
9. DEMOLISH AND REMOVE EXISTING CEILING AND CEILING SUPPORT FRAMING.
10. REMOVE, SALVAGE AND REINSTALL EXISTING BENCH AND CASEWORK. SEE PLAN
FOR NEW LOCATIONS.
11. REMOVE PARTITION OPENING FOR NEW DOOR AND WINDOW.
12. CUT AND REMOVE EXISTING CABINET ENTIRELY.
13. REMOVE EXISTING EXTERIOR FINISH. LEAVE THE 2X6 WD FRAMING TO SISTER WITH
NEW 2X6 WD STUDS. EXTEND TO TOP PLATE AND NEW ROOF BEARING.
14. REMOVE EXISTING PARTITION FINISH AND PREPARE FOR NEW GWB FINISH.
15. REMOVE EXISTING ROOF FRAMING AND ASPHALT ROOFING ENTIRELY.
16. REMOVE EXISTING SHED ROOF WOOD FRAMING AND CORRUGATED POLY PANELS.
17. REMOVE EXISTING CONCRETE PAD.
18. EXISTING MANHOLE TO REMAIN.
19. HEAVY LINE INDICATES EXCAVATION FOR CONCRETE FOOTING UNDER EXISTING
EDGE OF SLAB.
KEY NOTES
GENERAL NOTES
A SHEET 02 OF 07
SCALE:
HEADHOUSE PHASE 2 (TASK 1) DEMOLITION PLAN
1/4"= 1'-0"
AutoCAD SHX Text
FRAME SHED
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
A101
7'-1"
'-0
7'-1"
'-0
7'-1"
'-0
7'-1"
'-0
4'-2"
7'-10"
'-2
FRAME
SHED
FRAME
SHED
FRAME
SHED
FRAME
SHED
GREENHOUSE # 7
GEN
TANK ON
CONC.PAD
GREENHOUSE # 6
5'-10" 5'-10"9'-2 1/2"
9'-2 12"
D.
F.
F.
K.
I.
J.
R.
J.
K.
K.K.
K.
30'-1"
11'-4"
17'-1"
4'-8"
30'-1"
8' -9
8' -9
J.
J.
J.
J.
J.
J.
J.
J.
J.
J.J.J.
J.
J.
J.
J.
J.
J.
J.J.
J. J.
M
M
L
N L. L N
M
MM
M
'-2
'-7
'-7
7'-1"
H.
'-3
3' -1
1"
17'-4"
'-7
5' -8
5' -1
0"
MM
'-3
3' -1
1"
17'-6"
'-7
5' -1
1"
5' -9
'-7
3'-8" 2'-7"
K.
K.
F.
G.
G.
6 F.
6'-8"10'-10" 6'-9" 10'-7"
A.
A.A.
B.
B.
B.
B.
SLOPE TO GRADE
8'
CONCRETE
SLOPE DOWN
O.
P. P.N N
A.
Q
Q
5'
5'-6"
NEW
CONCRETE
INFILL, 12"
DEEP
CONNECT
TO EXISTING
SLAB WITH
#4 DRILLED
REINFORCEMENT
DOWELS 6"
O.C. E.W.
5'
5'-6"
G.
5'
5'-6" 5'-6"
5'
GREENHOUSE # 7
CORRIDOR
FRAME
SHED
GREENHOUSE # 6
TANK ON
CONC.PAD
EXIST.TO
REMAIN
GENERATOR EXISTING
TO REMAIN
ELECTRICAL EQUIPMENT
EXISTING TO REMAIN
CORRIDOR
POTTING SHED
DIRTY ROOM
CLEAN ROOM
ELECTRICAL CLOSET
SINK
INCUBATOR
PUMP
BENCH
DESK
SINK/BENCH
FRIDGE/
FREEZERBENCH
L.
NIC
NIC
C.
L.
N.
C.
L.
N.
C.
O.
1/4" = 1'-0"
A. HEAVY DOTTED LINE INDICATES NEW FOOTING ON (FRONT)
AND (BACK) WALL.
NEW 60"X66"x6" CONCRETE STOOP.
VERTICAL METAL PANEL ON OSB SHEATHING ON 2X6 WOOD
STUDS SISTERED WITH EXISTING FRAMING.
HOUSE WRAP ALL AROUND.(R19) INSULATION AND 1/2"
GYPSUM BOARD INTERIOR FINISH PAINTED.
OIL FURNACE ETR HERE.
NOT USED.
NEW 48"X84"X1 3/4" HOLLOW METAL DOOR AND FRAME WITH
MINIMUM 2-2X10 HEADER.
NEW 36"X80"X1 3/4" HOLLOW METAL DOOR AND FRAME WITH
MINIMUM 2-2X10 HEADER.
NEW INSULATED 8'-0"X8'-0" OVERHEAD SECTIONAL DOOR
WITH MINIMUM 2-2X10 HEADER.
INSTALL RESILIENT FLOORING AND GWB SUSPENDED
CEILING PAINTED.
INSTALL ALL WALLS AND CEILING WITH 1/2" GYPSUM BOARD
INTERIOR FINISH. CONCRETE FLOOR EPOXY PAINTED
EXCEPT CLEAN ROOM FLOOR TO BE SEAMLESS RESILIENT.
NEW 48"X24" CASEMENT WINDOWS.
WALL EXTERIOR TYPICAL:
· 2X6 WOOD FRAME WALL WITH STUDS @ 16"O.C.
· 2X6 DOUBLE TOP PLATE.
· 2X6 SINGLE BOTTOM/SILL PLATE. (PT)
· 15/32"MIN.CDX EXT PLYWOOD 8d NAIL U.O.S.
· 4" O.C. EDGE & 8" O.C. FIELD.
· HOUSE RAP AND R15 BATT INSULATION.
VERTICAL METAL PANEL ON 1/2" OSB SHEATHING ON 2X4
WOOD STUDS FRAMING
HOUSE WRAP ALL AROUND.(R15) BATT INSULATION AND 1/2"
GYPSUM BOARD INTERIOR FINISH PAINTED
WALL EXTERIOR, SHEAR:4' LONG EA SIDE OF EXTERIOR
CORNERS
· 6" NOMINAL WIDTH AS SHOWN.
· 2X6 WOOD FRAMED WALL WITH STUDS @ 16"O.C, 2X6
DOUBLE TOP PLATE.
· 2X6 SINGLE BOTTOM/SILL PLATE.
· 15/32" MIN CDX EXT.PLYWOOD 8d NAIL U.O.S.
· 3" O.C EDGE & 6: O.C. FIELD.
· HOUSE RAP AND R15 BATT INSULATION.
EXISTING LANDSCAPING MANHOLE TO REMAIN.
#5 REBAR EPOXY INTO FOUNDATION WALL WITH MINIMUM 6"
EMBEDMENT, 12" O.C.
6'-8"X3' WOOD HINGED ACCESS DOOR.
13/4" THICK IN ROUGH WOOD FRAME.
TWO 2'X6'-8" DOUBLE HOLLOW METAL DOOR AND FRAME
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:11 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-102 Headhouse Phase 2(Task 1)newe construction.dwg Save Date: 05/27/2022 01:39 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A102
NEW CONSTRUCTION
Q.
KEY NOTES
04 22
A SHEET 03 OF 07
SCALE:
HEADHOUSE PHASE 2 (TASK 1) NEW CONSTRUCTION
1/4"= 1'-0"
R.
AutoCAD SHX Text A103
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
A102
TOP EXIST.
CONC. SLAB
30'-1" 10'-6"17'-6"
GREENHOUSE # 6GREENHOUSE # 7
METAL WALL PANELS METAL WALL PANELS METAL WALL PANELS
EXISTING EXISTING
METAL WALL PANELS
STANDING SEAM METAL ROOFRIDGE COVER FLASHING
STANDING SEAM METAL ROOF
GUTTER AND DOWNSPOUTS
NEW WINDOWS AND
DOORS TYPICAL
TOP OF PLATE
TOP EXIST.
CONC. SLAB
34'-8"
9' -1
1 2"
EXISTING
GREENHOUSE # 6
METAL WALL PANELS
RIDGE COVER FLASHING
STANDING SEAM METAL ROOF
DS
METAL GUTTER
STANDING SEAM METAL ROOF
METAL SOFFIT
WITH VENTS
NEW WINDOWS
METAL LOUVER VENT
TOP OF PLATE
POTTING SHEDDIRTY ROOM
TOP EXIST.
CONC. SLAB
TOP OF PLATE
TOP EXIST.
CONC. SLAB
METAL GUTTER
CONC.SLAB
EXISTING
9' -1
7' -0
2'
-3
34'-8"
2' -1
9' -1
1 2"
9' -3
1 2"
3'-8"
METAL SOFFIT WITH
VENTS2'-3"
RIDGE COVER FLASHING
34'-8" SPAN TRUSS
ASYMMETRIC OVERHANG
UPLIFT 1,475 # /TRUSS
(1)SIMPSON MSTA21 TWIST STRAP
PER TRUSS RATED 1,505 #/UPLIFT
(16)0,148"DIAX2.5"NAIL TOTAL
(8)/EACH END OF STRAP
FOOTING ON SOUTH(FRONT) AND NORTH (BACK)
WALL.
EXCAVATE UNDER EXISTING SLAB EDGE BACK TO 7"
OFF CENTERLINE OF NEW EXTERIOR WALLS.
ESTABLISH NEW FOOTING POCKET:16"WIDE X 12" MIN
DEEP.
BOTTOM OF EARTH FORM FLAT TO +/-1/2".
PLACE (2)#5 60 KSI STEEL REBAR 3"ABOVE
OFF FOOTING POCKET.
PLACE 4,000 PSI CONCRETE TO 3" ABOVE
BOTTOM OF EXISTING SLAB EXTERIOR.
VIBRATE CONCRETE AT EVERY 4' ALONG
FOOTING POCKET AFTER CONCRETE PLACED
GOAL IS A SOLID COLD JOINT BETWEEN THE
TOP OF POCKET FOOTING AND THE BOTTOM OF THE
EXISTING SLAB.
7' -0
2" SHEATHING
TITE-LOC CLIP FASTENERS
METAL SOFFIT WITH
VENTS
2" GYPSUM BD
CEILING
R-38 INSULATIONMETAL GUTTER
PROVIDE POWDER ACTUATED
FASTENERS 4' OC.
TOP OF PLATE
TOP EXIST.
CONC. SLAB
34'-8"
9' -1
1 2"
3'-8"
GREENHOUSE # 7
EXISTING
METAL WALL PANELS
RIDGE COVER FLASHING
STANDING SEAM METAL ROOF
METAL GUTTER
DS
METAL SOFFIT WITH
VENTS
METAL LOUVER VENT
NEW WINDOWS
1/4" = 1'-0"
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:18 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-103.dwg Save Date: 05/20/2022 04:39 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A103
BUILDING ELEVATIONS
AND SECTIONS
05 22
A SHEET 04 OF 07
SCALE:
HEADHOUSE BUILDING WEST ELEVATION
1/4"= 1'-0"
SCALE:
HEADHOUSE BUILDING EAST ELEVATION
1/4"= 1'-0"
SCALE:
HEADHOUSE BUILDING SOUTH ELEVATION
1/4"= 1'-0"
SCALE:
HEADHOUSE BUILDING SECTION
1/4"= 1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text A105
AutoCAD SHX Text
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
AutoCAD SHX Text A103
AutoCAD SHX Text A103
AutoCAD SHX Text A103
A103
GREENHOUSE # 7
FRAME
SHED
FRAME
SHED
FRAME
SHED
FRAME
SHED
GREENHOUSE # 7
POTTING SHED
CORRIDOR
GEN
TANK ON
CONC.PAD
DIRTY ROOM
CLEAN
ROOM
30'-1"
30'-1"
GREENHOUSE # 6
GREENHOUSE # 6
'-3
17'-4"
'-7
"5' -8
5' -1
0"
'-3
17'-6"
'-7
" 5' -1
1"
5' -9
A105
A.
A.
A.
A.
B.
B.
B.
B.
C.
C. C.
C.
C.
C.C.
D.
D.
D.
D.
D.
SIM
CORRIDOR
GREENHOUSE # 7 GREENHOUSE # 6
FRAME
SHED
FRAME
SHED
FRAME
SHED
FRAME
SHED
GREENHOUSE # 7 GREENHOUSE # 6
POTTING SHEDCORRIDOR CORRIDOR
GEN
TANK ON
CONC.PAD
DIRTY ROOM
CLEAN ROOM
'-7
17'-6"
5' -1
1"
5' -9
30'-1"
'-3
'-3
17'-4"
'-7
"5' -8
5' -1
0"
1. 1.
1.1.
3.3.
3. 3.
2. 2.
4.
4.
4.
4.
4.
4.
4.
4.
4.
4. CORRIDOR
GREENHOUSE # 7
POTTING SHED
CORRIDOR
DIRTY ROOM
CLEAN ROOM
30'-1"
30'-1"
GREENHOUSE # 6
'-3
17'-4"
'-7
"5' -8
5' -1
0"
'-3
17'-6"
'-7
" 5' -1
1"
5' -9
6' -2
A.
B.
A.
A.A.
A.
A.
TYPICAL LIGHTS,
SEE ELECTRICAL
1/8" = 1'-0"
1. REMOVE EXISTING ROOF FRAMING AND ASPHALT ROOFING ENTIRELY.
REMOVE EXISTING SHED ROOF FRAMING AND ASPHALT ROOFING ENTIRELY.2.
REMOVE EXISTING SHED METAL GUTTER AND DOWNSPOUTS ENTIRELY.3.
REMOVE EXISTING ROOF PARAPET, MODIFIED BITUMEN ROOF SYSTEM ENTIRELY.4.
DEMOLISH AND REMOVE EXISTING ROOF VENTS.
C.
D.
B.
A.
TYPICAL ROOF CONSTRUCTION
METAL ROOFING PANELS 15 # FELT
ON 1/2" PLYWOOD SHEATHING W/CLIPS
ON PREENGINERED ROOF TRUSSES
@ 24'O.C. SEE SECTIONS.
R-38 INSULATION
PROVIDE ROOF FLASHING RIDGE VENT AND METAL
SOFFIT WITH VENTS.
PROVIDE METAL GUTTERS AND DOWNSPOUTS.
METAL ROOFING, SHEATHING & INSULATION AS
ABOVE. SEE SECTIONS FOR WOOD FRAMING..
A.
1/2" GWB CEILING PAINTED. (TYPICAL)
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:25 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-104.dwg Save Date: 05/25/2022 02:05 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A104
ROOF DEMOLITION AND
NEW CONSTRUCTION
KEY NOTES
KEY NOTES
KEY NOTES
06 22
A SHEET 05 OF 07
SCALE:
HEADHOUSE PHASE 2 (TASK 1) ROOF DEMOLITION
1/8"= 1'-0"
SCALE:
HEADHOUSE PHASE 2 (TASK 1) ROOF NEW CONSTRUCTION
1/8"= 1'-0"
SCALE:
HEADHOUSE PHASE 2 (TASK 1) REFLECTED CLG.PLAN
1/8"= 1'-0"
B. 4'x2' ATTIC ACCESS DOOR. SEE SPECIFICATIONS.
AutoCAD SHX Text A105
AutoCAD SHX Text
AutoCAD SHX Text A105
AutoCAD SHX Text
AutoCAD SHX Text A105
AutoCAD SHX Text
AutoCAD SHX Text A105
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
AutoCAD SHX Text A104
AutoCAD SHX Text A104
A104
TOP OF PLATE
TOP EXIST. CONC. SLAB
METAL SOFFIT WITH
VENTS
TYPICAL ROOF CONSTRUCTION
STANDING SEAM METAL ROOF ON 15#
FELT ON 1/2" PLYWOOD SHEATHING WITH
CLIPS ON ROOF TRUSSES @ 24" O.C. SEE
FRAMING PLAN .R-38 INSULATION
7' -0
2'
-1
9' -1
1 2"
MASONRY ANCHORS
AS REQUIRED
THRESHOLD SET IN CONTINUOUS
SEALANT BED; MUST BRIDGE
THERMAL BREAK IN SLAB
THERMAL BREAK IN SLAB BETW
INTERIOR AND EXTERIOR; FILL
WITH INSULATION
SCHEDULED DOOR FRAME
EXISTING CONC. SLAB
DOOR HEAD FLASHING
2" GYPSUM
BOARD
TRUSS TYP.
2'-0" O.C
2-2X10
SPF#2
METAL GUTTER
1'-2"
8"
PROVIDE ATTIC INSULATION BAFFLE VENTS
PROVIDE NEOPRENE
CLOSURE AND METAL DRIP
EDGE CONTINUOUS
NEW CONCRETE FOOTER AT
FRONT AND BACK WALLS
TOP OF PLATE
TOP EXIST. CONC. SLAB
RAKE TRIM
5/4X6 WD TRIM
5' -0
2'
-0
7' -0
2'
-1
CLADDING BASE
DRIP FLASH
VERTICAL METAL PANEL ON 12"SHEATHING
ON 2X4 WOOD STUDS SISTERED WITH EXISTING FRAMING
HOUSE WRAP ALL AROUND.(R19) INSULATION AND 12"
GYPSUM BOARD INTERIOR
WINDOW SILL
FLASHING
WINDOW HEAD
FLASHING
METAL SOFFIT WITH VENTS
2-2X10
SPF#2
TYPICAL ROOF CONSTRUCTION
STANDING SEAM METAL ROOF ON 15#
FELT ON 1/2" PLYWOOD SHEATHING WITH
CLIPS ON ROOF TRUSSES @ 24" O.C SEE
FRAMING PLAN .R-38 INSULATION
2' -0
TREATED WD NAILER
METAL GUTTER
PROVIDE NEOPRENE CLOSURE AND
METAL DRIP EDGE CONTINUOUS
VERTICAL METAL PANEL ON 12"SHEATHING
ON 2X4 WOOD STUDS SISTERED WITH EXISTING FRAMING
HOUSE WRAP ALL AROUND.(R15) INSULATION AND 12"
GYPSUM BOARD INTERIOR.
15# ASPHALT FELT OVER 1/2" PLYWOOD OR OSB DECK
TREATED WOOD NAILER. PROVIDE VENT HOLES UNDER DRIP EDGE.
METAL CAP FLASHING AND DRIP EDGE
TOP EXIST. CONC. SLAB
TOP OF PLATE
CORRIDOR
8' -0
8' -0
1 2"
TOP OF PLATE
TOP EXIST.
CONC. SLAB
RIDGE COVER FLASHING
STANDING SEAM METAL ROOF
2-2X10
SPF#2
OUTLINE OF FOOTING OR
FOUNDATION BELOW GRADE (TYP.)
6'-8"X3' WOOD
HINGED ACCESS
DOOR BEYOND
METAL LOUVER
1/2" GWB CEILING
ON 2 X 4 CEILING
JOISTS AT 24" O.C.
R38 BATT INSULATION
POWDER ACTUATED FASTENERS AT 2' O.C.
TYPICAL WITH 1 1/2" MINIMUM PENETRATION INTO
CONCRETE, ALL EXTERIOR WALLS
2X6 ROOF DECK
JOISTS AT 24" O.C.
PROVIDE WALL FLASHING AT ALL INTERSECTIONS
5/4 X 6 WOOD TRIM FACIA
POTTING SHED
TOP EXIST. INTERIOR CONC. SLAB
TOP OF PLATE
EXISTING CONCRETE
SLAB
2" GYPSUM
BOARD
TRUSS TYP.
2'-0" O.C
7' -0
2'
-3
9' -3
/2
1'-2"
8"
2'-3"
2' -0
TYPICAL ROOF CONSTRUCTION
STANDING SEAM METAL ROOF ON 15# FELT
ON 1/2" PLYWOOD SHEATHING WITH CLIPS
ON SCISSORS ROOF TRUSSES @ 24" O.C.
SEE FRAMING PLAN .R-38 INSULATION
METAL SOFFIT WITH
VENTS
WINDOW HEAD FLASHING
METAL GUTTER
2-2X10
SPF#2
WINDOW SILL FLASHING
PROVIDE ATTIC INSULATION BAFFLE VENTS
SECURE FIRST WALL BOTTOM
PLATE TO CONCRETE WITH
POWDER ACTUATED FASTENERS
AT 2' O.C. 1 1/2" PENETRATION
TYPICAL
NEW CONCRETE FOOTER AT
FRONT AND BACK WALLS
EXISTING GRADE
1. ALL CEILING SHALL BE AT 9'-1" UNLESS OTHERWISE NOTED.
2. BASIS OF DESIGN FOR THE WINDOWS AS MANUFACTURED
BY OR SIMILAR
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:31 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-105.dwg Save Date: 05/24/2022 08:54 AM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A105
WALL SECTIONS
GENERAL NOTES
07 22
A SHEET 06 OF 07
SCALE:
EXTERIOR WALL SECTION
3/4"= 1'-0"
1 SCALE:
EXTERIOR WALL SECTION
3/4"= 1'-0"
SCALE:
EXTERIOR WALL SECTION
3/4"= 1'-0"
SCALE:
EXTERIOR WALL SECTION
3/4"= 1'-0"
AutoCAD SHX Text
CONC.SLAB
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text POWDER ACTUATED FASTENERS AT 2' O.C. TYPICAL WITH 1 1/2" MINIMUM PENETRATION INTO CONCRETE, ALL EXTERIOR WALLS
AutoCAD SHX Text Scale: 3/4"=1'-0"
AutoCAD SHX Text 12"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 3'
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
AutoCAD SHX Text A105
AutoCAD SHX Text A105
AutoCAD SHX Text A105
A105
4'-0"
7' -0
'-3
H
FLUSH HM
F BA
8" -4
'-1
1"
FLUSH HM
G
3'-0"
6' -8
6'-11"
MANUAL SECTIONAL OVERHEAD
DOOR
17'-5"
INSULATED GLASS VIEWPORTS
9'
Q
3'-0"
6' -8
TOP OF FRAME
STEEL FRAME
3'-0"
6' -8
R
4'-2" 4'-2"
FLUSH WOOD
FLUSH HM
2" FACE TYPICAL
HOLLOW METAL
W
'-1
1"
6'-3"
5/4" WOOD DOOR FRAME
3/4" STOPS
'-3
9'
2" FACE
TYPICAL
C
HOLLOW METAL
H1
1 15/16"
5/ 8"
1 15/16"
/2
2"
VARIES
SCHEDULED EXTERIOR
WALL
1/2"
HOLLOW METAL FRAME
SCHEDULED DOOR
2-2X10 SPF # 2
GWB
EXTERIOR SHEATING
METAL WALL PANEL
METAL FLASHING
AND DRIP EDGE TRIM
CONTINUOUS SEALANT
ALL AROUND FRAME
2X6 WOOD STUDS
HOLLOW METAL FRAME
SCHEDULED DOOR
SCHEDULED PARTITION
VA
R
IE
S
J1
/1 6"
1/ 2"
5/8"
FACE OF PERPENDICULAR
PARTITION WHERE OCCURS
/1 6"
2 1/2" 2"
VA
R
IE
S
BRUSHED ALUMINIUM SADDLE
THRESHOLD
DOOR 100 ONLY
S1
SCHEDULED DOOR
SCHEDULED FLOOR
RESILIENT FLOOR ON CONC. ROOM
100 ONLY
1 15/16"
HOLLOW METAL FRAME BEYOND
1 15/16"
VARIES
CONCRETE SLAB
H2
SCHEDULED PARTITION
2"
2 1/2"
1 3/4" WOOD DOOR
2-2X10 SPF # 2
PANEL RIB METAL WALL
FLASHING AND DRIP TRIM
1/2"
1/2" WOOD TRIM
5/4" FRAME AND 3/4"
WOOD STOP
VA
R
IE
S
SCHEDULED PARTITION
/1 6"
/1 6"
VA
R
IE
S
SCHEDULED DOOR
2X6 WOOD STUDS
5/8" 2"
J2
PANEL RIB METAL WALL
HOLLOW METAL FRAME
CONTINUOUS SEALANT
CONC. FLOOR
BRUSHED ALUMINIUM SADDLE
THRESHOLD
SCHEDULED DOOR
HOLLOW METAL FRAME BEYOND
1 15/16" 1 15/16"
VARIES
S2
METAL WALL
PANEL AND EDGE
TRIM BEYOND
SLOPE 1/4"
IN 12"
H3
VARIES
1 15/16"
1/2"
5/ 8"
1 15/16"
/2
2"
VARIES
SCHEDULED PARTITION
1/2"
HOLLOW METAL FRAME
SCHEDULED DOOR
2-2X10 SPF # 2
2X4 WOOD STUDS
5/4" WOOD FRAME
AND TRIM
SEAL CONTINUOUS
SCHEDULED PARTITION
VA
R
IE
S
J3
2"
3"
2"
3/
4" D
O O
R
3/4" WOOD STOP
METAL WALL PANEL &
DOOR FRAME TRIM
FASTEN & SEAL CONTINUOUS
WOOD DOOR
EXTERIOR
SHEATHING
1/2" GWB
BRUSHED ALUMINIUM SADDLE
THRESHOLD 10" WIDE MINIMUM X 36"
LONG
S3
1 3/4" WOOD DOOR
EXISTING CONC. FLOOR
WOOD FRAME BEYOND
5" FRAME AND TRIM
METAL WALL PANEL
AND EDGE TRIM BEYOND
6" MINIMUM
EXTEND EDGE OF CONCRETE SLAB
AND TURN DOWN 20" MINIMUM
DRILL AND CONNECT WITH #4
REINFORCED BARS AT 8" OC
Plotted By: BENJAMIN MONTALBANO Plot Date: 5/31/2022 4:01:38 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\10-SAG20056.13_Arch\15- Ph 2 CAD\A-401.dwg Save Date: 05/25/2022 04:09 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
A401
DOOR AND FINISH
SCHEDULE AND DETAILS
08 22
A SHEET 07 OF 07
SCALE:
DOOR TYPES
NTS
SCALE:
DOOR FRAME
NTS
SCALE:
DOOR HEAD SECTION DETAIL
NTS
SCALE:
DOOR JAMB SECTION DETAIL
NTS
SCALE:
DOOR SILL SECTION DETAIL
NTS
SCALE:
DOOR HEAD SECTION DETAIL
NTS
SCALE:
DOOR SILL SECTION DETAIL
NTS
SCALE:
DOOR JAMB SECTION DETAIL
NTS
SCALE:
DOOR SILL SECTION DETAIL
NTS
SCALE:
DOOR JAMB SECTION DETAIL
NTS
SCALE:
DOOR HEAD SECTION DETAIL
NTS
DOOR SCHEDULE
DOOR NO. LABEL
DOOR FRAME DETAIL
HARDWARE SET REMARKSSIZE(WxHxT) TYPE MAT. FINISH UNDERCUT MAT. FINISH TYPE HEAD JAMB THRSHD
100 - 3'-0"x 6'-8"x 1 3/4" G HM PT 3/4" HM PT A 9/A401 4/A401 5/A401 CLASSRM INTERIOR DOOR
101 - 4'-0"x 7'-0"x 1 3/4" F HM PT - HM PT B 3/A401 7/A401 8/A401 ENTRY
102 - 3'-0"x 6'-8"x 1 3/4" Q WOOD PT - WOOD PT W 6/A401 10/A401 11/A401 GATE
103 - 4'-0"x 7'-0"x 1 3/4" F HM PT - HM PT B 3/A401 7/A401 8/A401 ENTRY
104 - 3'-0"x 6'-8"x 1 3/4" G HM PT 3/4" HM PT A 9/A401 4/A401 5/A401 ENTRY INTERIOR DOOR
105 - 3'-0"x 6'-8"x 1 3/4" G HM PT 3/4" HM PT A 9/A401 4/A401 5/A401 ENTRY INTERIOR DOOR
106 - 4'-0"x 7'-0"x 1 3/4" F HM PT - HM PT B 3/A401 7/A401 8/A401 ENTRY
107 - 4'-0"x 7'-0"x 1 3/4" F HM PT - HM PT B 3/A401 7/A401 8/A401 ENTRY
108 - 3'-0"x 6'-8"x 1 3/4" Q WOOD PT - WOOD PT W 6/A401 10/A401 11/A401 GATE
109 - 2'-2"x 6'-8"x 1 3/4" R HM PT - HM PT C 9/A401 4/A401 5/A401 STORAGE
NOTES:
1. DOOR AND FRAME COLOR; BEN-MOORE #984 SATIN IMPERVO.
2. SEE DRAWINGS SHEET A101 FOR LOCATION OF DOOR.
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM NAME FLOOR BASE WALLS
WALL FINISHES
CEILING
CEILING
FINISH
CEILING
HEIGHT
SHEET NO.
DETAIL
REMARKS
NORTH SOUTH EAST WEST
100 CLEAN ROOM VTC ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 9'-1" *RESILIENT FLOORING
101 DIRTY ROOM EPOXY PAINT ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 9'-1"
102 POTTING SHED EPOXY PAINT ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 9'-3"
103 CORRIDOR EPOXY PAINT ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 8'-0"
104 CORRIDOR EPOXY PAINT ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 8'-0"
105 ELECTRICAL CLOSET EPOXY PAINT ON CONC. VCT GYP BD GYP GYP GYP GYP GYP BD PAINT 9'-1"
*FLOOR ELEVATION VARIES
AutoCAD SHX Text Scale: 3"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'
AutoCAD SHX Text
SAFETY & HEALTH
AutoCAD SHX Text
REAL PROPERTY
AutoCAD SHX Text
DESIGNER
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
PROJECT MANAGER
AutoCAD SHX Text
PPM
AutoCAD SHX Text
EPM
AutoCAD SHX Text
SETTY
AutoCAD SHX Text
DATE
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text
USDA
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DATE
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text Service
AutoCAD SHX Text Research
AutoCAD SHX Text Agricultural
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DWG. NO
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
SOLICITATION NO.
AutoCAD SHX Text 03/11/2022
AutoCAD SHX Text
95%%% SUBMISSION
AutoCAD SHX Text
SHS
AutoCAD SHX Text
USDA CONTRACT: #AG-32SD-C-15-0066 ORDER#12305B20F0193
AutoCAD SHX Text
USDA HEADHOUSE # 2 RENOVATION
AutoCAD SHX Text
ORIGINAL DRAWING SIZE IS 30" X 42", SCALE ENTITIES ACCORDINGLY IF REDUCED.
AutoCAD SHX Text
CHATSWORTH NJ
AutoCAD SHX Text
TASK 1, PHASE 2
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
RUTGERS UNIVERSITY
AutoCAD SHX Text 05/04/2022
AutoCAD SHX Text
100%%% SUBMISSION
AutoCAD SHX Text 05/31/2022
AutoCAD SHX Text
FINAL
AutoCAD SHX Text
WC
AutoCAD SHX Text
TI
AutoCAD SHX Text
BM
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
AutoCAD SHX Text A401
A401
3:25:50 PM Saved By: BENJAMIN.MONTALBANO File: O:\2020\SAG20056.13\23-SAG20056.13_M\15- Task 1 Ph 2 HH CAD\20056.13_M001.dwg Save Date: 05/24/2022 12:08 PM
3040 WILLIAMS DRIVE, SUITE 600
FAIRFAX, VIRGINIA 22031
P: 703-691-2115 www. .com
TM
PROJECT NUMBER:
SAG20056.13
TRUE
NORTH
PLAN
NORTH
M001
GENERAL NOTES SYMBOLS ABBREVIATIONS
GENERAL NOTES,
SYMBOLS AND
ABBREVIATIONS
1. NOTICE TO BIDDERS, CONTRACTORS, & (SUB)CONTRACTORS
1.1 NOTES ON MECHANICAL COVER SHEET DRAWING ARE BASIC OUTLINE OF MORE COMPLETE DRAWINGS AND SPECIFICATION. CONTRACTOR SHALL INITIATE A PRE BID REQUEST FOR INFORMATION (RFI) TO ENGINEER OF RECORD, IF ANY CONFLICTS ARE FOUND BETWEEN DRAWINGS
AND SPECIFICATIONS PRIOR TO SUBMITTING THE BID TO GENERAL CONTRACTOR/OWNER.
1.2 THE MECHANICAL PORTION OF THE CONTRACT DOCUMENTS FOR THIS PROJECT ARE ONLY A PORTION OF A LARGER AND MORE COMPLETE SET OF DOCUMENTS DESCRIBING ALL OF THE WORK REQUIRED TO PROVIDE A COMPLETE PROJECT. THERE ARE ITEMS SHOWN ON EACH OF THE CONTRACT DOCUMENTS WHICH HAVE AN IMPACT ON THE QUANTITY OF MATERIALS AND THE AMOUNT OF LABOR TO BE PROVIDED BY THE DIVISION 23 (SUB)CONTRACTOR. THE DIVISION 23 (SUB)CONTRACTOR SHALL PERFORM CAREFUL COORDINATION WITH EACH OF THE CONTRACT DOCUMENTS AS REQUIRED TO PROVIDE AN ACCURATE BID AND TO SUBSEQUENTLY PROVIDE ALL OF THE MATERIALS AND LABOR NECESSARY FOR COMPLETE CONFORMANCE TO THE ENTIRE SET OF CONTRACT DOCUMENTS. FAILURE OF THE (SUB)CONTRACTORS TO COORDINATE WITH ALL OF THE CONSTRUCTION DOCUMENTS, BY VIRTUE OF THIS NOTICE, SHALL NOT RELEASE THE GENERAL CONTRACTOR, THE DIVISION 23 MECHANICAL (SUB)CONTRACTOR OR THE DIVISION 26 ELECTRICAL (SUB)CONTRACTOR FROM THE OBLIGATIONS OF PROVIDING ALL OF THE MATERIALS AND LABOR NECESSARY TO COMPLETE THE REQUIREMENTS OF WORK INDICATED ON
THE COMPLETE SET OF THE CONTRACT DOCUMENTS.
2. GENERAL:
2.1 THE MECHANICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND APPLICABLE JURISDICTIONAL BODIES AS LISTED
IN "CODES AND STANDARDS" BELOW.
2.2 THE CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS AND PAY FOR ALL PERMITS, FEES, CHARGES AND INSPECTION REQUIRED, AS WELL AS APPLICABLE HAULING, RIGGING AND TRANSPORTATION CHARGES APPLICABLE TO HIS WORK.
2.3 THE PROJECT SHALL BE BID ON THE BASIS OF SPECIFIED PRODUCT(S) WHICH ESTABLISH MINIMUM QUALITY REQUIREMENTS. WHERE MORE THAN ONE PRODUCT NAME IS INDICATED, BIDS SHALL BE BASED ON ONE OF THE NAMED PRODUCTS.
2.4 WHERE USE OF A PRODUCT REQUIRES CHANGES TO THE BASE BID DESIGN IN ORDER TO INCORPORATE THE PRODUCT INTO THE PROJECT, THE CONTRACTOR SHALL SUBMIT A LAYOUT SHOWING ALL CHANGES TO ARCHITECTURAL, STRUCTURAL, ELECTRICAL, PLUMBING AND MECHANICAL REQUIREMENTS. CHANGES DUE TO USE OF ""ACCEPTABLE EQUAL"" PRODUCTS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER AND THE COST OF CHANGES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE LAYOUT SHALL ACCOMPANY THE
PRODUCT SUBMITTAL DATA.
2.5 SUBSTITUTIONS FOR "ACCEPTABLE EQUAL" PRODUCTS NOT SPECIFIED WILL BE CONSIDERED WHEN INCLUDED WITH SUBMISSION OF THE BID AND SHALL BE SUBJECT TO ACCEPTANCE BY THE OWNER/ARCHITECT/ENGINEER. PROPOSALS FOR SUBSTITUTIONS SHALL INCLUDE, BUT NOT BE LIMITED TO: (1) ANY ADDED CREDIT OR COST. (2) PRODUCT IDENTIFICATION. (3) CODE COMPLIANCE. (4) REFERENCED STANDARD COMPLIANCE. (5) DESCRIPTION OF ALL CHANGES INCLUDING ARCHITECTURAL, STRUCTURAL, ELECTRICAL, AND MECHANICAL REQUIRED TO INCORPORATE SUBSTITUTED PRODUCT INTO THE PROJECT. THE OWNER RESERVES THE RIGHT TO REJECT PROPOSED SUBSTITUTIONS.
2.6 WHERE "OR EQUAL" PRODUCTS ARE INDICATED, THE BIDDER SHALL SUBMIT A LIST OF PROPOSED EQUAL SUBSTITUTE PRODUCTS WITH THE BID. THE LIST SHALL INCLUDE ADEQUATE SUPPORTING INFORMATION AS PROOF OF EQUALITY IN ORDER TO BE CONSIDERED ACCEPTABLE.
NO LATER SUBSTITUTES WILL BE CONSIDERED.
2.7 SUBSTITUTIONS SHALL PROVIDE THE SAME WARRANTY AS SPECIFIED FOR BASE BID PRODUCTS.
2.8 THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS FOR POINTS OF CONNECTIONS, CAPACITIES, AND ELEVATIONS OF SYSTEMS. IN ALL
AREAS AFFECTED BY THE PROJECT, CUT, PATCH, REPAIR, AND/OR REPLACE ALL MATERIALS DAMAGED AS A RESULT OF WORK. ALL REPAIRED FINISHES SHALL MATCH APPROPRIATE ADJACENT FINISHES. FILL VOIDS AROUND DUCTWORK PENETRATING WALLS WITH FIRE STOPPING
MATERIAL (THERMA-FIBER OR EQUAL).
2.9 THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF WORK INCLUDED IN THE PROJECT. DO NOT SCALE THE DRAWING. HE CONTRACTOR SHALL ESTABLISH FINAL DIMENSIONS FROM FIELD MEASUREMENTS PRIOR TO STARTING WORK. THE WORD
"PROVIDE" AS USED IN THE PROJECT SHALL BE DEFINED AS "FURNISH AND INSTALL."
2.10 PROJECT PREMISES SHALL BE THOROUGHLY CLEANED AND READY FOR OCCUPANCY, INCLUDING ALL FINISHES OF EQUIPMENT PROVIDED AS PART OF THE CONTRACTOR'S WORK. PROVIDE ONE NEW SET OF CLEAN AIR FILTERS FOR PROJECT CLOSEOUT.
2.11 PROVIDE ALL NECESSARY FOUNDATIONS, SUPPORTS, PADS AND BASES AS REQUIRED FROMMECHANICAL EQUIPMENT, PIPING, AND DUCTWORK AS PER DC BUILDING AND MECHANICAL INSTALL EQUIPMENT, PIPING, AND DUCTWORK SO AS TO BE FREE FROM OBJECTIONABLE NOISE AND VIBRATIONS. CONTRACTOR SHALL COORDINATE WORK WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS
PRIOR TO ACTUAL WORK.
2.12 ALL INSULATION EXPOSED TO OUTDOOR WEATHER CONDITION SHALL BE PROVIDED WITH WEATHER PROOF JACKETING (SEE COMPONENT (DUCT/PIPING/ EQUIPMENT) INSULATION SPECS) SUITABLE FOR OUTDOOR SERVICE AND IN ACCORDANCE WITH ASHRAE 90.1-2010/IECC-2012
3. EQUIPMENT:
3.1 ALL MECHANICAL EQUIPMENT SHOWN ON CONTRACT DOCUMENTS SHALL BE NEW, AND SHALL BE PROVIDED BY THE MECHANICAL
CONTRACTOR UNLESS OTHERWISE NOTED.
3.2 MECHANICAL EQUIPMENT AND PRODUCTS SHALL BE LISTED AND/OR LABELED BY AN APPROVED TESTING OR INSPECTION AGENCY IN
ACCORDANCE WITH LOCAL AND GOVERNING CODE REQUIREMENTS.
3.3 EQUIPMENT AND PRODUCT MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS FOR INSTALLATION AND OPERATION SHALL BE FOLLOWED IN PERFORMING MECHANICAL WORK,UNLESS OTHERWISE INDICATED OR DIRECTED. MATERIALS AND METHODS USED IN THE WORK SHALL BE COMPATIBLE WITH BUILDING CONDITIONS AND COMPLY WITH THE BUILDING CODE REQUIREMENTS, WHICH SHALL BE THE BASIS FOR MINIMUM PRODUCT QUALITY. ALL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER BY SKILLED WORKMEN EXPERIENCED IN THEIR TRADE. THE WORK SHALL BE SUBJECT TO THE ACCEPTANCE OF THE OWNER OR THE DULY AUTHORIZED
REPRESENTATIVE.
4. DUCTWORK:
4.1 CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY DUCTWORK DROPS, RISES OR TRANSITIONS REQUIRED FOR DUCT
ROUTING IN THE CEILING PLENUM.
4.2 DUCTWORK SHALL BE FABRICATED WITH THE MATERIAL AS SPECIFIED IN THE 'DUCT WORK' SPECIFICATION,CONSTRUCTION AND INSTALLATION IN ACCORDANCE WITH SMACNA STANDARDS AND SYSTEM REQUIREMENTS. SHEET METAL GAUGES SHALL CONFORM TO THE INTERNATIONAL MECHANICAL CODE (IMC), ASHRAE STANDARDS, UL AND SMACNA LISTED FIRE RESISTANCE DIRECTORY REQUIREMENTS AS APPLICABLE. DUCTWORK SIZES SHOWN ARE NET CLEAR INSIDE DIMENSIONS. FABRICATE SHEET METAL FOR INTERNALLY LINED DUCTS TO ALLOW FOR THICKNESS OF INSULATION AND MAINTAIN NET CLEAR DIMENSIONS. CONTRACTOR SHALL VERIFY ACTUAL AVAILABLE DUCT SPACE PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK. SHOULD A CONFLICT OCCUR THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER BEFORE CONTINUING. ALL RECTANGULAR DUCTWORK ELBOWS 30° OR GREATER SHALL BE PROVIDED WITH
DOUBLE RADIUS TURNING VANES.
4.3 ALL DUCTWORK SHALL BE FABRICATED FROM FIELD CONFIRMED CONDITIONS. NO ALLOWANCE PERMITTED FOR DUCTWORK NOT USED.
FLEX DUCTS SHALL BE A MAXIMUM OF 6 FEET IN LENGTH AND ALL FLEX DUCT TO BE EXTERNALLY INSULATED ONLY.
4.4 ALL NECESSARY ALLOWANCES AND PROVISIONS SHALL BE MADE BY CONTRACTOR FOR BEAMS, COLUMNS OR OTHER OBSTRUCTIONS OF THE BUILDING OR THE WORK OF OTHER CONTRACTORS, WHETHER OR NOT SAME IS INDICATED. WHERE NECESSARY TO AVOID OBSTRUCTIONS, THE DUCTS SHALL BE TRANSFORMED, DIVIDED, OFFSET, RAISED OR LOWERED WITH THE REQUIRED FREE AREA BEING
MAINTAINED IN ACCORDANCE WITH SMACNA STANDARDS.
4.5 PROVIDE FIRE DAMPERS IN HVAC AIR DISTRIBUTION SYSTEMS THAT PENETRATE FIRE RATED ASSEMBLIES IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODES (IBC), INTERNATIONAL MECHANICAL CODES (IMC) & 12E FIRE DAMPERS SHALL BE TYPE B IN ALL SUPPLY/RETURN/EXHAUST/OUTSIDE AIR DUCTS THAT PENETRATE RATED ASSEMBLIES IN ADDITION TO ALL SECONDARY FIRE DAMPERS FOR CEILING/WALL AND FLOOR MOUNTED AIR DEVICES. COORDINATE SPECIFIC FIRE RESISTIVE CONSTRUCTION REQUIREMENTS WITH THE FIRE RATED ASSEMBLIES INDICATED ON ARCHITECTURAL DRAWINGS. THROUGH PENETRATIONS FIRESTOP SYSTEMS SHALL CONFORM TO UL LISTED FIRE RESISTANCE DIRECTORY OR OTHER METHODS ACCEPTABLE TO LOCAL GOVERNING CODE AUTHORITIES
4.6 PROVIDE ACCESS DOORS IN DUCTWORK TO PROVIDE ACCESS FOR ALL SMOKE DETECTORS, FIRE DAMPERS, SMOKE DAMPERS, VOLUME DAMPERS, MOTORIZED DAMPER, DUCT HEATERS, COILS, AND OTHER ITEMS LOCATED IN THE DUCTWORK WHICH REQUIRE SERVICE AND/ OR
INSPECTION.LABEL ACCESS WITH 1/2" LETTERING.
4.7 EXTERIOR LOUVERS ARE INDICATED FOR INFORMATION ONLY. LOUVER SIZES, LOCATIONS, AND DETAILS SHALL BE PER ARCHITECTURAL DWGS AND SPECIFICATIONS AND SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR AND OTHER TRADES INVOLVED PRIOR TO
INSTALLATION.
4.8 DUCT SMOKE DETECTORS SHALL BE INSTALLED IN ALL RETURN AIR DISTRIBUTION SYSTEMS WITH A DESIGN CAPACITY OF 2000 CFM OR GREATER IN ACCORDANCE TO THE INTERNATIONAL MECHANICAL CODE SECTION 606 AND NATIONAL FIRE PREVENTION CODE NFPA 72.
4.9 INSULATION: INSULATE ENTIRE SUPPLY AND RETURN AIR DUCTS AND PLENUMS WITH A MINIMUM 'R' INSULATION VALUE AS PER ASHRAE 90.1-2010/IECC-2012 ALONG WITH VAPOUR BARRIER IN ACCORDANCE WITH DC MECHANICAL CODE-604.
This is the start of the file's text. The full file is on GovTribe.