School Administration Building Roof Replacement
Closed State & local contract opportunity Posted
- Solicitation number
- IFB 2026-056
- State
- North Carolina
- Responses due
Opportunity facts
- Jurisdiction
- Point of contact
-
- Corey Brooks corey.brooks@unioncountync.gov (704) 283-3683
Opportunity details come from constructionbidsource.com. Updated .
About this opportunity
Union County, North Carolina, Department of Public Works is soliciting bids for a School Administration Building roof replacement project, with sealed bids due July 9, 2026 at 2:00 p.m. at Union County Procurement and Contract Management, 610 Patton Avenue, Monroe, North Carolina. A non-mandatory pre-bid conference and site visit is scheduled for June 23, 2026 at 10:00 a.m. at the project location, 400 North Church Street, Monroe, North Carolina 28112.
The scope includes removal of the existing roof system down to the structural deck and installation of a new complete, watertight roof assembly with sheet metal flashing and accessories warranted for 20 years. HVAC modifications require raising two HVAC units at roof section C to a minimum eight-inch flashing height, rerouting and raising gas lines to accommodate the new roof, and providing new insulated ductwork and supports from the units to wall penetration. Alternate No. 1 provides new elevation wall sealant joints around the building perimeter. Alternate No. 2 provides approximately 40 linear feet of new fall protection handrails on roof area C along the gutter edge at HVAC units. Bidders must submit separate pricing for the base scope and each alternate. The contractor must coordinate with Union County Facilities and Fleet Management for access, security, and facility shutdowns throughout the project.
The construction documents were prepared by Gensler Architecture, Design & Planning, P.C. and REI Engineers Inc., dated May 29, 2026. The procurement representative is Corey Brooks, Director of Procurement and Contract Management, at (704) 283-3683 or Corey.brooks@unioncountync.gov. The primary design contact is Zachary Marlowe, EIT, RRO, REWO, Senior Project Manager at REI Engineers.
Opportunity text
2 versions
Update #2 · Latest ·
Remove existing roof system down to the existing structural deck and provide new roof system along with sheet metal flashing and accessories to provide a complete, watertight, 20-year warrantable roof assembly. HVAC Modification: Raise 2 HVAC units at roof C providing minimum 8 flashing height, reroute/raise gas lines to provide adequate space for roof installation, and provide new insulated ductwork and supports from units to wall penetration. Alternate NO. 1: Provide new elevation wall sealant joints around perimeter of the building. Alternate NO. 2: Provide approximately 40 LF of new fall protection handrails on roof area C along gutter edge at HVAC units.
Update #1 ·
Remove existing roof system down to the existing structural deck and provide new roof system along with sheet metal flashing and accessories to provide a complete, watertight, 20-year warrantable roof assembly. HVAC Modification: Raise 2 HVAC units at roof C providing minimum 8 flashing height, reroute/raise gas lines to provide adequate space for roof installation, and provide new insulated ductwork and supports from units to wall penetration. Alternate NO. 1: Provide new elevation wall sealant joints around perimeter of the building. Alternate NO. 2: Provide approximately 40 LF of new fall protection handrails on roof area C along gutter edge at HVAC units. The Work includes coordinating with Union County Facilities and Fleet Management for access, security, and shutdowns.
Files
| File | Type | Posted |
|---|---|---|
| Union County School Administration Roof Replacement Project.pdf | ||
| Advertisement for Bid (1).pdf |