FFY26 Mansfield PBXP262019 Bldg 600 HVAC
Closed State & local contract opportunity Posted
- Solicitation number
- SRC0000041927
- State
- Ohio
- Responses due
Opportunity facts
Opportunity details come from ohiobuys.ohio.gov. Updated .
About this opportunity
The Ohio state entity is soliciting bids for HVAC replacement at Building 600 in Mansfield under FFY26 PBXP262019, with proposals due September 24, 2026.
The scope encompasses disconnection and offsite disposal of an existing 6-ton Trane condenser (model TWA073D30RAA, single compressor, R-410A); furnishing and installation of one new like-in-kind outdoor heat pump unit compatible with existing electrical service and controls; all necessary materials, fittings, line sets, and accessories for system integration; completion of refrigerant, electrical, auxiliary heat staging, and control connections; furnishing and installation of a new non-programmable digital thermostat with independent low-voltage control wiring run from thermostat to indoor and outdoor equipment, separate from any existing DDC system network; system startup with verification of proper operation in both heating and cooling modes and correction of deficiencies; and provision of applicable warranty documentation for installed equipment.
No contract value, contract term, set-aside or preference program, evaluation criteria, incumbent contractor, or additional procurement timeline detail is specified in the source.
Opportunity text
A. Disconnect, remove, and dispose offsite the existing outdoor 6-ton condenser; Trane model TWA073D30RAA, Single Compressor, R-410A. B. Furnish and install one new like-in-kind outdoor heat pump unit compatible with the existing system, existing electrical service, and existing controls C. Furnish and install all necessary materials, fittings, line sets, and accessories required to connect the new heat pump unit to the existing system D. Complete all required refrigerant, electrical, auxiliary heat staging, and control connections for a complete and operational installation E. Furnish and install one new non-programmable digital thermostat to control the system locally. The contractor shall run new low-voltage control wiring as required from the thermostat to the indoor and outdoor equipment, completely independent of the existing DDC system network. F. Start up the new heat pump system, verify proper operation in both heating and cooling modes, and correct any deficiencies identified during startup. G. Provide applicable warranty documentation for the installed equipment.
On GovTribe
Work this opportunity
- Track it in your pipeline
- Similar opportunities