SDC Pistol Range Armory Structure Building
Past New Requirement Updated
- Agency
-
Customs and Border Protection
Department of Homeland Security
- Solicitation expected
- Estimated value
- $1,000,000 to $2,000,000
- Set-aside
- Competitive 8(a)
Forecast facts
- Anticipated award
- Through
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- San Diego, DC
- Forecast number
- F2025070713
- Points of contact
-
- Rolando Gonzales rolando.gonzales@cbp.dhs.gov (619) 247-8425
- Daniel Cardenas daniel.cardenas@cbp.dhs.gov (830) 778-7081
Forecast details come from DHS's Acquisition Planning Forecast System. Agencies' dates and values are estimates.
About this forecast
The U.S. Customs and Border Protection is seeking a contractor to design and construct a ballistic concrete armory storage building at the San Diego Border Patrol Pistol Range located at 2301 McCain Road in San Diego, California. The facility will measure 70 feet wide by 25 feet long by 15 feet high (approximately 1,100 square feet) and will replace non-compliant Connex buildings currently used for ammunition storage. The structure must be constructed with concrete slab, walls, and ceiling with explosive-rated exterior and interior doors, load-rated shelving for palletized ammunition, dedicated HVAC with separate thermostat and humidity control, security and communication conduit infrastructure, lighting and electrical outlets, and a forklift-accessible concrete ramp. The contractor must hire a certified engineer to design the facility in accordance with U.S. Border Patrol Facility Design Standards and current federal regulations. The solicitation is estimated to release on January 26, 2026, with an anticipated award date of April 1, 2026.
The estimated award value ranges from $1,000,000 to $2,000,000 under a Firm Fixed Price contract vehicle, with the period of performance estimated from April 1, 2026, through September 30, 2026. This opportunity is set aside as a Competitive 8(a) contract with an anticipated 8(a) direct award to Lunoor Construction, Inc. The contract falls under NAICS code 236220 (Commercial and Institutional Building Construction). Points of contact include Daniel Cardenas at daniel.cardenas@cbp.dhs.gov or (830) 778-7081 for federal inquiries, and Rolando Gonzales at rolando.gonzales@cbp.dhs.gov or (619) 690-7797 for requirements-related questions.
Forecast text
The San Diego Border Patrol Pistol Range requires a CBP certified armory storage building to be built outside the existing shooting range building located at 2301 McCain Road San Diego, California. Range is currently using Connex buildings for storage which is out of compliance for ammo storage. The Ballistic Concrete Structure Building dimension is 70’-0 W X 25’-0 L X 15’-0 H. Square footage roughly 1,100. The entire structure will consist of Concrete Slab, Concrete Walls and Concrete Ceiling with explosive rated exterior and interior doors. The building structure will contain load rated shelving for palletized ammunition with additional secure storage. The load rated shelving will be accessed through 1 double sided doors entrance 48” W X 72” H X 2”. Height of double-sided doors will depend on height bottom ceiling of structure. Doors are to be placed west end of structure with a concrete ramp for forklift access or other equipment. In addition, the new structure will need 2 single-door entrances with concrete ramp that will accommodate a pallet forklift equipment to enter. One located north of a new structure and one entering existing wall that will need to be cut out to the current ammo room. Dimensions door 48” W X 72”H X 2”. All armory doors are to be fire rated & explosively rated. Storage facility will need to have security and communication ridged conduit in placed for future installation. Exterior and interior light fixtures with light switches will need to be installed, including receptacle outlets and outlets for forklift. Ammo facility is required to have it own separate HVAC unit package with thermostat to keep ammo free of heat and humidity and exhaust units. HVAC unit is to be placed on roof Last; Contractor shall hire certified engineer to design Weapons and Ammunition Storage from U.S. Border Patrol Facility Design Standard and Current Federal Regulation.
Acquisition Strategy: 8a direct award to Lunoor Construction, Inc.V
On GovTribe
Work this forecast
- Track it in your pipeline
- Find teaming partners
- Similar forecasts
- Ask GovTribe AI about this forecast