Forecast details come from the Navy's Long Range Acquisition Estimates. Agencies' dates and values are estimates.
About this forecast
Naval Facilities Engineering Command (NAVFAC) is issuing a delivery order under contract N3943023D4051 to conduct comprehensive power flow analysis and develop a 15% conceptual design for a secure, resilient microgrid at Naval Submarine Base Kings Bay, Georgia, with an estimated solicitation release date of April 1, 2026 and estimated award date of July 1, 2026. The work encompasses evaluation of transmission line loads, cross-connect capabilities, load-shedding options, black start, islanding, and infrastructure constraints; incorporation of existing generation, renewables, and Battery Energy Storage Systems; reinforcement of SCADA communication and Risk Management Framework cybersecurity; and development of project documentation (DD Form 1391) for future projects. Personnel must hold Secret clearances.
The estimated award value is up to $2 million for a 14-month period of performance. Work is performed in Norfolk, Virginia under fixed-price delivery order terms (not under a Federal Supply Schedule Contract). The procurement is unclassified and proceeds through NAVFAC Atlantic (N62470) as a sole-source fixed-price order under the General Architect and Engineering classification (PSC C219).
Forecast text
The primary objective is to conduct a comprehensive power flow analysis and develop a 15% conceptual design for a secure, resilient microgrid at Naval Submarine Base Kings Bay (NSBKB). Evaluate transmission line loads, cross-connect capabilities, load-shedding options, black start, islanding, and infrastructure constraints. Incorporate existing generation, renewables, and Battery Energy Storage Systems (BESS). Reinforce SCADA communication and Risk Management Framework (RMF) cybersecurity for future expansion. Recommend resilience improvements. The findings will also be used to develop a project documentation (DD Form 1391) for future project(s).