31971772: FY27 Waterfront Inspections DNW & DSW

Forecast New Requirement Updated

Agency
Solicitation expected
Estimated value
$1,000,000 to $2,000,000
Set-aside
No set-aside

Forecast facts

Anticipated award
Through
NAICS code
237990 Other Heavy and Civil Engineering Construction
Place of performance
Oakland, CA
Forecast number
F2026074913
Points of contact

Forecast details come from DHS's Acquisition Planning Forecast System. Agencies' dates and values are estimates.

About this forecast

The U.S. Coast Guard is procuring comprehensive waterfront facility inspection and assessment services for waterfronts in the Pacific Northwest and Northern California, with solicitation release estimated for December 1, 2026, and award anticipated for January 1, 2027. The contract requires above-water and underwater structural inspections of qualifying waterfront structures, detailed assessment reports for each facility, structural analysis to verify or update operational load limits, and Condition Index ratings for floating docks and gangways. The inspection team must include Professional Structural Engineers (PE/SE) registered and licensed in Washington, Oregon, and California, along with certified commercial diving personnel.

The estimated award value ranges from $1,000,000 to $2,000,000 under a Firm Fixed Price contract using the Architecture and Engineering Services II contract vehicle. Performance runs from January 1, 2027, through March 31, 2027, with place of performance in Oakland, California. Tony Flores, Contracting Specialist/Officer at CEU Oakland, serves as the primary point of contact at tony.l.flores@uscg.mil or (571) 607-1071.

Forecast text

-Facility Assessments: Conduct comprehensive above-water and underwater structural inspections on all qualifying waterfront structures and generate a detailed Assessment Report for each facility.

-Condition Index (CI) & Structural Analysis: Perform structural analyses to verify or update posted operational load limits following each inspection. Floating docks and associated gangways shall be inspected and assigned Condition Index (CI) ratings (load limit calculations excluded).

-Professional Qualifications: The inspection team must include Professional Structural Engineers (PE/SE) registered and licensed in the applicable jurisdiction(s) being inspected (Washington, Oregon, and California), along with certified commercial diving personnel.

On GovTribe

Work this forecast

  • Track it in your pipeline
  • Find teaming partners
  • Similar forecasts
  • Ask GovTribe AI about this forecast