Yearly Fire Inspections

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912ES24Q0045
Agency
ENDIST St Paul US Army Corps of Engineers, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
541990 All Other Professional, Scientific, and Technical Services
PSC
H342 Inspection- Fire Fighting/Rescue/Safety Equipment; Environ Protect Equipment/Matls
Place of performance
Fountain City, Wisconsin 54629, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The US Army Corps of Engineers is seeking to procure annual fire inspections and related services for portable fire extinguishers, fixed fire suppression systems, and fire control panels at various locations. The key requirements include performing periodic inspections and maintenance in accordance with NFPA, OSHA, and US Army Corps of Engineers guidelines, as well as providing detailed reports of any deficiencies found. Repairs up to $5,000 may be authorized with prior approval. The contract will have a base year and four option years, with inspections due by May 1st for the Fountain City Service Base and Maintenance and Repair Fleet, and by July 1st for the Dredge Goetz Fleet.

This opportunity is set aside for small businesses. The NAICS code is 561621 (Security Systems Services (except Locksmiths)) and the PSC code is S206 (Guard Services). No potential incumbents are named. The estimated value of the contract is not provided, but the quantities of fire protection equipment and systems to be inspected at each location are detailed in the solicitation. The place of performance is Fountain City, Wisconsin.

Notice text

Scope of Work – Yearly Fire Inspection

Fire Extinguishers, Fire Suppression Systems, and Fire Control Panels

                                        

 Project Description:

The US Army Corps of Engineers, Physical Support Branch, requests annual and periodic inspections of all portable fire extinguishers, fixed fire suppression systems, 1 Amrex galley hook fire suppression system and 4 fire control panels. All inspections will be conducted in accordance with NFPA chapters 10 and 17A, OSHA and US Army Corps of Engineers Health and Safety Manual 385‐1‐1 requirements.

Scope of Work:

Line 1-Fountain City Service Base & 5A Warehouse-Table 1

Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers. This inspection shall be completed by 01 May of each calendar year of the contract, including all options.  See attached list for quantities and locations of all extinguishers associated with the Fountain City Service Base. Building 3 (office building) (SIEMENS Cerberus) has a fire control panel that requires inspection, testing, and servicing. The Fountain City Service Base systems list of all extinguishers/systems is below (Table 1).

Line 2-Dredge Goetz-Table 2

Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Dredge Goetz Fleet, this inspection shall be completed by 01 July of each calendar year of the contract, including all options. The quarter’s barge Taggatz has one Amrex galley hood fire suppression system that requires servicing and inspection also. The Warioto (Notifier SFP-2404), General Warren (SIEMENS System 3), Goetz (Notifier AFP-200), and Taggatz (ANSUL AutoPluse IQ-301) all have Fire control panels that require inspection, testing, and servicing. See attached list for quantities and locations of all extinguishers associated with the Goetz Fleet (Table 2).

Line-3:Maintenance & Repair-Table 3

Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Maintenance and Repair Fleet. This inspection shall be completed by 01 May of each calendar year of the contract, including all options. See attached list for quantities and locations of all extinguishers associated with the Maintenance and Repair Fleet (Table 3)

The contractor shall create a report that lists any deficiencies that are found that require repairs. This report shall be sent to the Technical Points of Contract. The contractor shall create a report that lists any deficiencies that are found that require repairs. This report shall be sent to the Technical Points of Contact. Repairs shall not be completed without prior written approval from the Contracting Officer’s Representative (COR) and if the aggerated amount of the repairs exceeds $ 5,000.00 the contractor must have written approval from the Contracting Officer. All repairs must be completed within 10 working days of Contracting Officer’s approval.

Attachments

Files attached to this notice, newest first
File Type Posted
W912ES24Q0045P00001.pdf PDF
W912ES24Q0045-final.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Yearly Fire Inspections Award Award Notice
Yearly Fire Inspections This notice · Latest solicitation Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity