This document is an amendment to a solicitation from the U.S. Army Corps of Engineers for yearly fire inspections of portable fire extinguishers, fire suppression systems, and fire control panels at the Fountain City Service Base, the Dredge Goetz Fleet, and the Maintenance and Repair Fleet. The scope of work includes performing annual and periodic inspections, as well as addressing any required repairs, with a not-to-exceed amount of $5,000 for repairs. The solicitation response date has been extended from March 20, 2024 to March 28, 2024. The contract will require inspections to be completed by May 1 for the Fountain City Service Base and Maintenance and Repair Fleet, and by July 1 for the Dredge Goetz Fleet. The document also provides detailed lists of the specific fire protection equipment and systems to be inspected at each location.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912ES24Q0045-final.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W912ES24Q0045
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
To answ er industry questions, updated the locations of the fire supression equipment, and to extend the date of the solicitation to 3/28/2024 3:00 pm.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 20
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 21-Mar-2024
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912ES24Q0045
X 9B. DATED (SEE ITEM 11)
06-Mar-2024
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
22-Mar-2024
CODE
CONTRACTING DIVISION
USACE, ST PAUL
332 MINNESOTA STREET
SUITE E1500
ST PAUL MN 55101-1323
W912ES 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
ANSWERS TO INDUSTRY QUESTIONS
1. Is everything listed a fire extinguisher and/or pull-down boxes, or both? The items in the table are either fire extinguishers or CO2 tanks. There are also fire control panels on some of the vessels which are noted in the line descriptions that need to be inspected.
2. Is this solicitation for two different locations on the same bases? The inspections are for the Fountain City Service Base at 431 North Shore Drive, Fountain City, WI 54629 and two floating plant fleets: Goetz Fleet and M&R Fleet. Each of the floating plant fleets have multiple vessels that need inspections. The M&R floating plant has a home base at the Fountain City Base. We will coordinate that the inspections are completed at the service base. For the first year of the contract the Crane Barge Leonard will be located at Lock and Dam 2,1350 Lock and Dam Road, Hastings, MN 55033 until the end of May so the inspection will need to be completed at that location. It will be at the Fountain City base in subsequent years. For the first year of the Dredge Goetz Fleet portion of the contract the inspections will need to be completed when it is dredging between the Fountain City, WI and Reeds Landing, MN. We will coordinate with the contractor the date and times as well as provide transportation to the Fleet via boat from a designated landing closest to the Fleet. We will also provide transportation from the Dredge Fleet to shore for the hydrostatic testing. This testing must be completed within two days.
The Dredge Goetz will be located at the Fountian City Base in subsequent years.
3. Are these fire systems and/or sprinkler systems? There are CO2 fire suppression systems in most of the vessel engine rooms.
4. Table #3 lists maintenance and repair fleet. These in need of maintenance in addition to the inspections, correct? All items listed in the solicitation may require maintenance or repairs.
5. In addition to Point #4, The items listed in table #3 may need repairs (if applicable)? All items listed in the solicitation may require maintenance or repairs.
6. In order for us to perform the hydrostatic testing, we will need to take perform that service off site for a few days. Will the boats be docked long enough, or would we receive a schedule of their docking? See the answer to question #2.
7. Are the 4 control panels are internal alarm systems? Yes
8. On page 8 of the solicitation, near the top of the table where it says "Stationary CO2 room", are those Suppression systems? Yes these are the CO2 tanks for the suppression system.
9. Also on page 8, near the bottom of the table where it says, "Shop Fixed System", are those Suppression systems? Yes these are the CO2 tanks for the suppression system.
10. On page 12 near the top/middle, there is a gas listed in the TYPE column that says "chlorotetrafluorethane". Does this line represent a portable fire extinguisher? Yes a portable fire extinguisher.
11. I noticed in CLINs 0001-0003 the use of the word periodic along with the required annual inspections. I'm trying to figure out how often periodic is and the extent of what is expected from a periodic inspection (10% of the inventory, 20% etc.) Yes, these date reflect the last time the six year maintenance and a hydrostatic tests, every 12 years, were performed on the item.
12. On CLIN 0004 for repairs it has an NTE of $5,000 for the repairs. Without knowing what the repair is for
I'm not sure how to help them fill out the unit price in the quote for CLIN 0004. Should this just be input at the NTE Unit Price? Yes, the contract will have these CLINs (0004, 1004, 2004, 3004, & 4004) priced at $5,000 and will be adjusted to match actuals each year based on the approved repairs performed.
13. In looking at the tables for the extinguishers inspection list I noticed various dates listed under the Hydro Date. Can you explain what these dates reflect? Are these the base dates that should be used to price the "periodic" inspection/hydrostatic testing dates? Yes, these dates are the last dates the hydrostatic testing was completed. The hydrostatic testing and inspections are to be included in the inspection CLINS and not considered a repair.
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 20-Mar-2024 03:00 PM to 28-Mar-2024 03:00 PM.
The following have been modified:
SCOPE OF WORK
Scope of Work – Yearly Fire Inspection Fire Extinguishers, Fire Suppression Systems, and Fire Control Panels
Project Description:
The US Army Corps of Engineers, Physical Support Branch, requests annual and periodic inspections of all portable fire extinguishers, fixed fire suppression systems, 1 Amrex galley hook fire suppression system and 4 fire control panels. All inspections will be conducted in accordance with NFPA chapters 10 and 17A, OSHA and US Army Corps of Engineers Health and Safety Manual 385‐1‐1 requirements.
Scope of Work:
Line 1-Fountain City Service Base & 5A Warehouse-Table 1 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers. This inspection shall be completed by 01 May of each calendar year of the contract, including all options. See attached list for quantities and locations of all extinguishers associated with the Fountain City Service Base. Building 3 (office building) (SIEMENS Cerberus) has a fire control panel that requires inspection, testing, and servicing. The Fountain City Service Base systems list of all extinguishers/systems is below (Table 1).
Line 2-Dredge Goetz Fleet-Table 2 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Dredge Goetz Fleet, this inspection shall be completed by 01 July of each calendar year of the contract, including all options. The quarter’s barge Taggatz has one Amrex galley hood fire suppression system that requires servicing and inspection also. The Warioto (Notifier SFP-2404), General Warren (SIEMENS System 3), Goetz (Notifier AFP-200), and Taggatz (ANSUL AutoPluse IQ-
301) all have Fire control panels that require inspection, testing, and servicing. See attached list for quantities and locations of all extinguishers associated with the Goetz Fleet (Table 2).
Line-3:Maintenance & Repair Fleet-Table 3 Perform periodic inspection, to include annual inspection and an internal maintenance inspection (hydrostatic test and/or internal examination) shall be inspected at the maintenance interval as determined by OSHA 29 CFR 1910.157, on all portable fire extinguishers and installed systems on the Maintenance and Repair Fleet. This inspection shall be completed by 01 May of each calendar year of the contract, including all options. See attached list for quantities and locations of all extinguishers associated with the Maintenance and Repair Fleet (Table 3)
Line-4: Repair of Items-
The contractor shall create a report that lists any deficiencies that are found that require repairs. This report shall be sent to the Contracting Officer’s Representative (COR). Repairs shall not be completed without prior written approval from the (COR) and if the aggerated amount of the repairs exceeds $ 5,000.00 the contractor must have written approval from the Contracting Officer. All repairs must be completed within 10 working days of written approval.
Recurring maintenance work required annually and the additional work required every six (6) years is part of the base line items 1-3 and must be priced into those lines. These costs will not be reimbursed under the repair line (4).
Technical point of contact: (to be given upon contract award)
Location Information:
U.S. Army Corps of Engineers Mississippi River Project Office 431 North Shore Drive Fountain City, WI 54629
Hours of Operation:
0700 – 1530: Monday – Friday Closed: Weekends & Federal Holidays
LINE 1 SERVICE BASE
Fire Control Panel
Office Building
Make and Model: Siemens FC2005 FC901
Initiating Devices Quantity Smoke Detectors 19
Pull Boxes 3
Notification Devices Quantity Strobe Light/Buzzer 10
EXTINGUISHER INSPECTION LIST
# STATION & LOCATION TYPE SERIAL # WEIGHT HYDRO DATE
1 B1 Garage - Outside South Door ABC SJ-382226 20# 7/1/2021 2 B1 Garage - Inside South Door ABC XK-200536 5# 5/1/2023 3 B1 Garage - Garage Bay ABC SJ-382235 20# 7/1/2021 4 B1 Garage - Outside North ABC SN-507680 20# 7/1/2021 5 B2 Paint - Outside West Door ABC ZR-559061 20# 7/1/2020 6 B2 Paint - Inside West Door ABC VR-490792 20# 4/1/2022 7 B2 Paint - Inside East Door ABC AZ-654879 20# 3/1/2019 8 B3 Office - Lower Conference Room ABC C-94497981 10# N/A - NEW 9 B3 Office - Entry Foyer ABC SJ-382236 20# 7/1/2021 10 B3 Office - Mechanical Room ABC AZ-654858 20# 7/1/2020 11 B3 Office - Garage Door Opener ABC SJ-382246 20# 7/1/2021 12 B3 Office - Outside West Door ABC SJ-382222 20# 3/1/2022 13 B3 Office - Server room C Z-579175 5# 3/1/2022 14 B3 Office - Top Stairwell ABC SJ-382189 20# 7/1/2021 15 B3 Office - Kitchenette ABC SJ-380581 20# 7/1/2021 16 B4 Mill - NW Outside ABC SN-507695 20# 7/1/2021 17 B4 Mill - West Bay ABC SJ-382198 20# 7/1/2021 18 B4 Mill - NE Door ABC SJ-382251 20# 7/1/2021 19 B4 Mill - Outside East Door ABC SJ-382234 20# 7/1/2021 20 B4 Mill - S Bay ABC CC-951920 20# 7/1/2020 21 B4 Mill - Electrical Main Wall ABC E-83207197 20# 3/1/2020 22 B10 Upper - Inside West Door ABC SN-507690 20# 3/1/2021 23 B10 Upper - Inside North Door ABC SJ-382233 20# 7/1/2021 24 B10 Upper - Lean-to Bay 3 (North) ABC WR-719076 20# 5/1/2023 25 B10 Upper - Lean-to Bay 4 ABC SJ-382221 20# 7/1/2021 26 B10 Upper - Lean-to Bay 5 (South) ABC SJ-382225 20# 7/1/2021 27 B12 Welding - NE Window ABC ZR-490134 10# 7/1/2020 28 B12 Welding - North Garage Door ABC WE-612045 10# 7/1/2021 29 B12 Welding - West Middle Wall ABC SJ-382197 20# 3/1/2022 30 B12 Welding - South Door ABC SJ-382248 20# 2/1/2018 31 B12 Welding - Weld Cart ABC VR-707113 2.5# 2/1/2018 32 Bobcat S630 Skidsteer ABC ZT-863273 2.5# 6/1/2023 34 Doosan D35C-7 Forklift ABC A-31467902 2.5# 7/1/2021 35 Manitowoc 14000 Crane ABC A-330018 2.5# 7/1/2020 36 Oil/Water Separator ABC SN-507689 20# 7/1/2021 39 4000Gal Diesel Tank ABC G-99516335 20# N/A - NEW 40 Lower/South Lean-to ABC WR-719085 20# 5/1/2023 41 Ram 3500 Service Truck ABC YG-868763 20# 7/1/2020 42 Doosan D70S-9 Forklift ABC AU-226362 2.5# 7/1/2020 5A Warehouse
EXTINGUISHER INSPECTION LI ST
33 South Door ABC SJ-382185 20# 5/1/2023 37 Komatsu FG15 Forklift ABC A-31467900 2.5# 5/1/2023 38 Clark CMP 75SD Forklift ABC SL-256113 2.5# 7/1/2021
LINE 2 DREDGE GOETZ FLEET
Fire Control Panels Goetz
Make and Model: Notifier AFP-200
Smoke Detectors 3
Pull Boxes 6 Heat Detectors 8
Notification Devices Quantity Strobe Lights 1
Strobe Light/Buzzer 3 CO2 Siren 1
Taggatz
Make and Model: Amrex Galley Hood Fire Suppression System
Taggatz Make and Model: ANSUL AutoPluse IQ-301
Smoke Detectors 47
Pull Boxes 12 Heat/Thernal Detectors 5
Relays 1 Notification Devices Quantity
Horns/Strobe 13
M/v General Warren Make and Model: Siemens System 3
Smoke Detectors 18
Pull Boxes 10 Heat/Thernal Detectors 17
Relays 2 Notification Devices Quantity
Strobe Lights 1 Horns Strobe 6
M/v Warioto
Make and Model: Notifier SFP-2404
Smoke Detectors 15
Pull Boxes 8 Heat/Thernal Detectors 15
Notification Devices Quantity Strobe Lights 1 Horns/Bells 10
Fire Extinguisher and CO2 tanks
TAGGATZ EXTINGUISHER INSPECTION LIST
1 Emrg.Fire Pump Rm. Dry Chem 10# ZR-490127 16.4 Jun-12 2 EXP. Metal BHO. Dry Chem 10# 51052 16.4 May-11 3 FWD Winch Room Dry Chem 10# ZR-490120 16.4 Dec-11 4 Exercise Room Dry Chem 10# ZR-490148 16.4 Jun-12 5 Diesel Oil Tank Void Dry Chem 10# ZR-490128 16.4 Jun-12 6 Generator Rm Port Fwd Dry Chem 10# ZR-490118 16.4 Jun-12 7 Generator Rm Fwd Center Dry Chem 10# ZR-490138 16.4 Jun-12 8 Generator Room Stbd Dry Chem 10# ZR-490124 16.4 Jun-12 9 Diesel Oil Tank Void Stbd Dry Chem 10# ZR-490116 16.4 Jun-12
10 Generator Rm Stbd Aft Dry Chem 10# ZR-490112 16.4 Jun-12 11 Aux Mach Rm Port Aft Dry Chem 10# ZR-490129 16.4 Jun-12 12 Aft Spud Winch Room Dry Chem 10# ZR-490125 16.4 Jun-12 13 Main Deck Stbd Fwd Dry Chem 10# ZR-490117 16.4 Jun-12 14 Port Fwd Dry Chem 10# ZR-490115 16.4 Jun-12 15 Stbd Midship Dry Chem 10# ZR-490126 16.4 Jun-12 16 Port Midship Dry Chem 10# ZR-490133 16.4 Jun-12 17 Aft Main Deck Dry Chem 10# ZR-490135 16.4 Jun-12 18 Port Aft Dry Chem 10# ZR-490140 16.4 Jun-12 19 Upper Deck Stbd Fwd Dry Chem 10# ZR-490113 16.4 Jun-12 20 Upper Deck Fwd Dry Chem 10# ZR-490136 16.4 Jun-12 21 Upper Deck Stbd Midship Dry Chem 10# ZR-490422 16.4 Jun-12 22 Upper Deck Port Midship Dry Chem 10# ZR-490119 16.4 Jun-12 23 Upper Deck Stbd Aft Dry Chem 10# ZR-490122 16.4 Jun-12 24 Upper Deck Port Aft Dry Chem 10# ZR-490121 16.4 Jun-12 25 Ships Office Stbd Dry Chem 10# ZR-490132 16.4 Jun-12 26 Ships Office Port Dry Chem 10# ZR-490131 16.4 Jun-12 27 Galley Aft Dry Chem 10# ZR-490123 16.4 Jun-12 28 Galley Port Aft Dry Chem 10# ZR-490147 16.4 Jun-12 29 Galley Port Fwd Dry Chem 10# ZR-490141 16.4 Jun-12 30 Galley Stbd Fwd Wet Chem AB-766541 24.12 Jun-12 31 Ships Mess Port Dry Chem 10# ZR-490134 16.4 Jun-12 33 Ships Mess Stbd Dry Chem 10# ZR-490139 16.4 Jun-12 34 Upper Deck Elect Eq Rm Dry Chem 10# 69473 17.25 Jun-12 35 Main Deck Galley DryStores FOAM AB-130115 2.5 gal. Jun-12 36 Emergency Fire PumpRoom Dry Chem 20# ZR-559063 32.75 Jun-12 37 Stbd Generator Room Dry Chem 20# ZR-559061 32.75 Jun-12 38 Port Generator Room Dry Chem 50# ZJ-54102 163 Jun-12 39 Stationary CO2 Room CO-2 NK-38206 286.5 Jul-07
40 Stationary CO2 Room CO-2 NK-38195 282.9 Jul-07 41 Stationary CO2 Room CO-2 NK-38203 288.2 Jul-07 42 Stationary CO2 Room CO-2 NK-38196 288.9 Jul-07 43 Stationary CO2 Room CO-2 NK-38183 286.1 Jul-07 44 Stationary CO2 Room CO-2 NK-38171 288.1 Jul-07 45 Stationary CO2 Room CO-2 NK-38204 283.4 Jul-07 46 Stationary CO2 Room CO-2 NK-38205 284.4 Jul-07
9511 EXTINGUISHER INSPECTION LIST
STATION & LOCATION TYPE SERIAL # WEIGHT HYDRO DATE
1 FUEL BARGE 9511-A CO-2 15# 694892 44.9 July-12
2 FUEL BARGE 9511-A DRY CHEM 10# 417419 Gauge 2014
GOETZ EXTINGUISHER INSPECTION LIST
1 VFD ROOM CO-2 15# 287669 35.7 Mar-18 2 PORT WINCH ROOM DRY CHEM 10# 290222 Gauge 2020 3 PUMP MOTOR ROOM DRY CHEM XA-109132 Gauge 2018-Mar 4 PUMP ROOM DRY CHEM XA-109120 Gauge 2018-Mar 5 LEVER HOUSE DRY CHEM XA-109126 Gauge 2018-Mar 6 ENGINE ROOM DRY CHEM 507693 Gauge Nov-09 7 PORT ENGINE ROOM CO-2 15# 36887 35.8 Mar-18 8 STBD ENGINE ROOM CO-2 15# 732040 35.25 2018-Mar 9 SHOP-FIXED SYSTEM CO-2 KF93522 283.9 Mar-16
10 SHOP-FIXED SYSTEM CO-2 KF95165 284 Mar-16 11 SHOP-FIXED SYSTEM CO-2 KF93437 286.3 Mar-16 12 SHOP-FIXED SYSTEM CO-2 KF93532 289.1 Mar-16 13 SHOP-FIXED SYSTEM CO-2 KF93117 283.2 Mar-16 14 SHOP-FIXED SYSTEM CO-2 KF93531 284.2 Mar-16 15 SHOP-FIXED SYSTEM CO-2 KF93110 283.4 Mar-16 16 SHOP-FIXED SYSTEM CO-2 KF95201 283 Mar-16 17 WINCH RM. Flammable Locker CO2 25# 67276 80.4 Mar-18 18 Hobby RM. Flammable Locker CO2 25# 67276 80.4 Mar-18
GENERAL WARREN EXTINGUISHER INSPECTION LIST
1 PILOT HOUSE DRY CHEM 10# 614101 Gauge 2018-Apr 2 PLENUM AREA DRY CHEM 10# 612002 Gauge 2018-Apr 3 3 RD DECK HALL DRY CHEM 10# 612040 Gauge 2018-Apr
4 2 ND DECK HALL DRY CHEM 10# 612007 Gauge 2018-Apr 5 LOUNGE DRY CHEM 10# 612041 Gauge 2018-Apr 6 MESS AREA DRY CHEM 10# 607020 Gauge 2018-Apr 7 DECK STORAGE DRY CHEM 10# 612038 Gauge 2018-Apr 8 GALLEY DRY CHEM 10# 607018 Gauge 2018-Apr 9 1 ST DECK HALL DRY CHEM 10# 612045 Gauge 2020-Jun
10 FWD ENGINE ROOM CO-2 15# 694890 44 2018-Apr 11 AFT ENGINE ROOM DRY CHEM 10# 607004 Gauge 2018-Apr 12 ENG. CONTROL RM. DRY CHEM 10# 607007 Gauge 2014-May 13 ENG. CONTROL RM PORT DRY CHEM 10# 612014 Gauge 2018-Apr 14 GENERATOR ROOM CO-2 15# Y-0694892 44 2018-Apr 15 STEERING ROOM CO-2 15# Y-0694882 44 2018-Apr 16 FWD STORES CO-2 15# Y-0694889 44 July-12 17 STBD FUEL / BALLAST RM. CO-2 15# 45602 44 2018-Apr 18 ENG. LOWER CENTER CO-2 15# X601461 44 2018-Apr 19 ENG. LOWER AFT CO-2 15# 979313 44 2018-Apr 20 SHAFT ALLEY DRY CHEM 10# 612060 Gauge 2014-May 21 FIXED SYSTEM CO-2 100# KF-87847 283.3 Mar-16 22 FIXED SYSTEM CO-2 100# KF87877 284.7 Mar-16 23 FIXED SYSTEM CO-2 100# KF-87908 282.1 Mar-16 24 FIXED SYSTEM CO-2 100# KF-87868 283.2 Mar-16 25 FIXED SYSTEM CO-2 100# KF-87852 286.6 Mar-16 26 FIXED SYSTEM CO-2 100# KF-87873 288 Mar-16 27 FIXED SYSTEM CO-2 100# KF-89081 280.3 Mar-16 28 FIXED SYSTEM CO-2 100# KF-88594 283.8 Mar-16
29 RESCUE BOAT DRY CHEM 5# 271377 9 2013
WARIOTO EXTINGUISHER INSPECTION LIST
1 PILOT HOUSE DRY CHEM 10# GB-00514119
Feb-13
2 2 ND DECK HALL DRY CHEM 10# GA-00180440
3 DECK LOCKER DRY CHEM 10# GB-00514167
4 UPPER ENGINE ROOM CO-2 10# RT-183490
5 LOWER ENGINE ROOM CO-2 10# SC-178151
6 FIXED SYSTEM FM-200 628# 570346 1224 Nov-15
7 FIXED SYSTEM FM-200
Dec-14
852 BOOSTER EXTINGUISHER INSPECTION LI ST
1 FWD CONTROL ROOM CO2 #15 36888 41 Apr-11 2 AFT CONTROL ROOM CO2 #15 287670 35 Apr-11 3 WORK BENCH / OFFICE DRY CHEM #10 841042 Gauge May-11
PIPELINE EQUIPMENT EXTINGUISHER INSPECTION LIST
1 GENERATOR PONTOON 9038 CO-2 15# 131745 41 May-12 2 END PONTOON 20" 9033 DRY CHEM 10# 265173 Gauge 2011 3 WINCH ELBOW 20" 9037 CO-2 15# 52817 44.625 May-12 4 WINCH 9035 DRY CHEM 10# YR265215 Gauge 2007 5 WINCH M-17 DRY CHEM 10# 818800 Gauge Jul-12 6 WINCH M-26 DRY CHEM 5# ZD-816117 Gauge 2007 7 WINCH 195 CO2 15# 148919 44 May-11 8 WINCH 204 CO-2 15# 580957 43 May-11 9 WINCH MULLEN ELBOW 9044 DRY CHEM 10# 490130 Gauge May-14
10 ANCHOR BARGE 766 CO-2 15# 519953 41 May-13 11 ANCHOR WINCH 96 CO-2 15# 964896 38 Jul-12 12 ANCHOR WINCH 9036 DRY CHEM 10# 288427 Gauge 2007 13 BARGE 774 CO-2 / 15# D941302 38 May-11 14 CAT BARGE 779 DRY CHEM 5# 573418 Gauge 2013 15 Air Compressor DRY CHEM 5# 942833 Gauge 2014
HEAVY EQUIPMENT EXTINGUISHER INSPECTION LIST
1 TRACTOR J.D. 555G DRY CHEM 5# 458098 Gauge Jan-13 2 TRACTOR D-7R DRY CHEM 5# 864407 Gauge 2014 3 EXCAVATOR 330C DRY CHEM 5# ZD826978 Gauge 2007 4 Lorain Crane DRY CHEM 5# 566639 Gauge 2011 5 950J JD TRACTOR DRY CHEM 5# 872473 Gauge 2012 6 Magnum Light Plant DRY CHEM 5# 621480 Gauge 2012 7 D6H Caterpillar DRY CHEM 5# 942131 Gauge 2012
DUNNAGE BARGE EXTINGUISHER INSPECTION LIST
1 DUNNAGE BARGE FWD CO-2 15# F9144 44 May-12 2 DUNNAGE BARGE AFT CO-2 15# E468A 40 May-12 3 HOME PONT LOCKER CO-2 25# KF67496 80.5 Apr-12
9041 & 9034 BARGE EXTINGUISHER INSPECTION LIST
1 FUEL BARGE 9041 AFT DRY CHEM 2.5# 226851 Gauge 2012
2 FUEL BARGE 9041 CO-2 15# 242043 44 2011
3 FUEL BARGE 9041 BOW DRY CHEM 2.5# 226630 Gauge 2012 4 GAS BARGE 9034 CO-2 15# 718195 41 May-11 5 GAS BARGE 9034 DRY CHEM 20# SJ-382188 Gauge Mar-13
FLUEKIGER EXTINGUISHER INSPECTION LIS T
1 FLUEKIGER PILOT HSE CO-2 15# 732039 35.25 Mar-16 2 FLUEKIGER FWD ENG RM CO-2 15# 903431 35.7 May-11 3 FLUEKIGER AFT ENG RM CO-2 15# 511128 45.7 Mar-18 4 FLUEKIGER STATION CO-2 75# KFU15651 221 Dec-15 5 FLUEKIGER STATION CO-2 75# KFU15813 222 Dec-15
FIEDLER EXTINGUISHER INSPECTION LIST
1 FIEDLER Pilot House Dry Chem # 10 ZR490142 16.4 May-14 2 FIEDLER ENG RM CO-2 15# 272298 32.8 May-12 3 FIEDLER ENG RM C0-2 15# 36886 44.7 Mar-11 4 FIEDLER STATIONARY CO-2 75# KFO15833AA 224.6# Jan-03 5 FIEDLER STATIONARY CO-2 75# KFU15786AA 218.6# Jan-03
HOOPER EXTINGUISHER INSPECTION LIST
1 HOOPER ENG RM DRY CHEM 10# 490130 Gauge Apr-08 2 HOOPER PILOT HSE DRY CHEM 5# ZT168310 Gauge Jan-08
PECK EXTINGUISHER INSPECTION LIST
1 M/L PECK Cabin Dry Chem 10# 868763 Gauge MAY, 2012 2 M/L PECK Cabin CO-2 15# 524108 45.5 May-11 3 M/L PECK Chlorotetrafluoroeth ane 48360 Gauge
HOME PONTOON EXTINGUISHER INSPECTION LIST
1 HOME PAINT LOCKER CO-2 25# KF67530 80.3
OUTBOARD EXTINGUISHER INSPECTION LIS T
1 Skiff No. 1 DRY CHEM 2-1/2# G-539335 Gauge 2009 2 Skiff No. 2 DRY CHEM 5# 621441 Gauge May-12 3 Skiff No. 3 DRY CHEM 5# 573424 Gauge
4 Engineers DRY CHEM 5# 923265 Gauge 2012 5 Deckcrew DRY CHEM 5# 226362 Gauge 2012
Table 3: Maintenance and Repair Fleet
Fire Control Panels Crane Barge 3129
Make and Model: SIEMENS FH-2071-UM
Smoke Detectors 16
Pull Boxes 11 Heat Detectors 3
Relays 35
Strobe Lights/Horn 6
Crane Barge Leonard Make and Model: Notifier NFS-320
Pull Boxes 2 Heat/Thernal Detectors 6
Notification Devices Quantity Strobe Lights 3 Horns/Bells 4
M/v Fountain City
Pull Boxes 2 Heat/Thernal Detectors 3
Strobe Lights 2 Horns/Bells 2
M/v Butler
Smoke Detectors 2
Pull Boxes 1 Heat/Thernal Detectors 1
Strobe Light/Buzzer 1
M/v Lyon
Smoke Detectors 1
Pull Boxes 1 Heat/Thernal Detectors 1
M/v MacNamara Make and Model: Potter PFC 4064
Smoke Detectors 1
Pull Boxes 1 Heat/Thernal Detectors 1
M/v Wells
Smoke Detectors 2
Pull Boxes 1 Heat/Thernal Detectors 1
Fire Extinguisher and CO2 tanks Crane Barge 3129
Unit Number Station and Location Type Serial # Weight Inspection HYDRO Deck
Generator Room 1 Double entry door Co2 H-41049095 20# 23-Jul
2 Single entry door Dry Chem ABC H-11835947 20# 23-Jul
Outside Generator Room 3 Port-Suppression system Co2 System 23-Jul
4 Starboard-Suppression system Co2 System 23-Jul
Office 5 Window Dry Chem ABC H-15732615 2.5# 23-Jul
Locker Room 6 Inside right of Door Dry Chem ABC H-20352777 10# 23-Jul
7 Top of stairs Co2 H-09431975 10# 23-Jul
Below Deck
Stairwell 8 Behind stairs Dry Chem ABC H-20344590 10# 23-Jul
Co2 H-09431982 10# 23-Jul
Galley 9 Starboard door Dry Chem ABC H-15731607 2.5# 23-Jul
10 Port door Co2 H-14143457 5# 23-Jul
Stern by Spud controls 11 Starboard spud control pannel Dry Chem ABC H-20344019 10# 23-Jul
12 Port spud contril pannel Co2 H-09431974 10# 23-Jul
Fuel Oil Tank-Port 13 Rear wall Dry Chem ABC H-20354375 10# 23-Jul
Waste Oil Tank-Port 14 Forward wall Co2 H-09431981 10# 23-Jul
Port Storage/Shop 15 Port wall Dry Chem ABC H-20354370 10# 23-Jul
16 Port wall Co2 H-09431980 10# 23-Jul
Starboard Head Storage 17 Inner wall Dry Chem ABC H-20354373 10# 23-Jul
18 Inner wall Co2 H-09431984 10# 23-Jul
Starboard Spud/Shop 19 Spud control Dry Chem ABC H-20344017 10# 23-Jul
20 Rear wall Co2 H-09431973 10# 23-Jul
CO2 Storage Room 21 CO2 Storage Room Dry Chem ABC 23-Jul
22 CO2 Storage Room CO2 100# 22NKE19355 23-Jul 2022 23 CO2 Storage Room CO2 100# 22NKE19381 23-Jul 2022 24 CO2 Storage Room CO2 100# 22NKE19384 23-Jul 2022
Office Barge Unit Number Location Type Serial # Weight Inspection HYDRO
Office 1 Breakroom Starboard door Dry Chem ABC SV-062626 10# 23-May 20-Jul
Garage 2 Garage by roll up door Dry Chem ABC B-08246186 10# 23-May 23-May
Electrical Office Barge
1 Storage by door Dry Chem ABC FC-00346700 10# 23-May 21-Jul 2 Breakroom Dry Chem ABC CC-944703 10# 23-May 20-Jul 3 Office by door Dry Chem ABC ZR-490131 10# 23-May 20-Jul
Hauser Crane Barge
1 Stern Spud house outside Dry Chem ABC SJ-82245 20# 23-May 21-Jul 2 Bow Spud house outside Dry Chem ABC N/A 20# 23-May 19-Mar 3 Port entry door Dry Chem ABC N/A 20# 23-May 21-Jul 4 Starboard tery door Dry Chem ABC VR-485324 20# 23-May 21-Jul
Link Belt LS-218-H 1 Behind seat Dry Chem ABC TF-350787 5# 23-May 19-Mar
Leonard Crane Barge Unit Number Loction Type Serial # Weight Inspection HYDRO
Deck 1 Deck locker Dry Chem ABC A-38767205 20# 23-Jun 21-Aug 2 Auxiliary generator room Dry Chem ABC H-395399 20# 23-Jun 21-Aug
Below Deck 1 Bottom of stairs Dry Chem ABC PR-180094 10# 23-Jun 22-Mar 2 Electrical by Machinery door Dry Chem ABC NL-945226 10# 23-Jun 21-Aug 3 Electrical by Pump room door Dry Chem ABC NL-945214 10# 23-Jun 21-Aug 4 Machinery rom (3S) Dry Chem ABC PR-180101 10# 23-Jun 21-Aug
CO2 Storage Room 5 CO2 Storage Room CO2 100# 2023 6 CO2 Storage Room CO2 100# 2023 7 CO2 Storage Room CO2 100# 2023 8 CO2 Storage Room CO2 100# 2023 9 CO2 Storage Room CO2 100# 2023
10 CO2 Storage Room CO2 100# 2023 11 CO2 Storage Room CO2 100# 2023
MV Fountain City
First Deck 1 Bow Deck Dry Chem ABC YB-758503 20# 23-May 19-Mar 2 Galley Dry Chem ABC VU-827152 10# 23-May 19-Jan 3 Engine Suppression system CO2 100# 23-May
4 Engine room Starboard door Dry Chem ABC SC-178151 10# 23-May 20-Jul 5 Engine room Starboard door Dry Chem ABC RT-183490 10# 23-May 20-Jul 6 Engine room Port door Dry Chem ABC JD-670063 10# 23-May 19-Mar 7 Engine room Port door Dry Chem ABC XG-12415 20# 23-May 19-Mar 8 Stern work room Dry Chem ABC SJ-32310 5# 23-May 19-Mar 9 Stern work room Dry Chem ABC YB-758509 20# 23-May 19-Mar
10 Stern work room Loaded Steam G-39493251 30# 23-May
11 Stern Deck Dry Chem ABC YB-758533 20# 23-May 19-Mar Second Deck
12 Front Room Dry Chem ABC C-91440506 5# 23-May 23-May 13 Back Room Dry Chem ABC H-13564644 5# 23-May N/A
Pilot House 15 Pilot House Dry Chem ABC A-955360 10# 23-May 22-Apr
MV Butler
1 Deck Room entry door Dry Chem ABC ZX-500076 20# 23-Jun 21-Aug 2 Engine room entry door Dry Chem ABC PR-180060 10# 23-Jun 19-May 3 Stern stairs engine room Dry Chem ABC ZX-500069 20# 23-Jun 22-Apr 4 2nd deck starboard storage Dry Chem ABC PR-180083 10# 23-Jun 19-May 5 Pilot house Dry Chem ABC CC-942848 5# 23-Jun 21-Aug 6 Engine Suppression system CO2 75#
7 Engine Suppression system CO2 75#
8 Engine Suppression system CO2 75#
9 Engine Suppression system CO2 75#
Paint Connex
1 Inside on floor/Needs replaced Dry Chem ABC VR-485337 20# 2022
2 Suppression system Dry Chem ABC IND-45 45# 2023
Seatrax Crane
1 Generator room Dry Chem ABC AD-63849 20# 23-Sep 22-Mar 2 Engine room Dry Chem ABC AD-63846 20# 23-Sep 22-Mar 3 Cab Dry Chem ABC AD-64930 20# 23-Sep 22-Mar
Tenders
Unit Number Location Type Serial # Weight Insection HYDRO MacNamara Engine Room
1 Front entry door port Dry Chem ABC F-63777907 10# 23-Sep
2 Front entry door starboard Dry Chem ABC SH-827136 10# 23-Sep
3 Lower engine bottom of stairs Dry Chem ABC C-97522561 10# 23-Sep
4 Rear entry door top of stairs Dry Chem ABC YA-517863 10# 23-Sep
5 Front starboard CO2 100# 100# 23-Sep
Pilot House 6 Backside of pilot house Dry Chem ABC SJ-380589 20# 23-Dec 15-Apr
Wells Engine Room 1 Bow entry door Dry Chem ABC G-39493264 30# 23-May
2 Stern entry door Dry Chem ABC A-31331537 10# 23-May
3 Co2 Suppression system CO2 100# 23-Sep
Pilot House 4 Backside of pilot house Dry Chem ABC VR-490801 20# 23-May 22-Apr
Lyon Engine Room
1 Suppression system-ABC Dry Chem ABC 23-Aug
2 Bow Top of stairs Co2 962352C 15# 23-Aug
3 Stern entry door Co2 W-36899 15# 23-Aug
4 Co2 Suppression system CO2 100# 23-Sep
Pilot House 4 Inside Pilot house Dry Chem ABC YR-265147 10# 23-Aug 18-Mar
Equipment
946 Liebherr Excavator 1 Behind seat Dry Chem ABC C-98408762 5# May 23-May
Case Loaders 1 Case 721F - Behind seat Dry Chem ABC AU-170936 5# 23-May 23-May 2 Case 821B - Beind seat Dry Chem ABC N/A
Grove RF-400 1 Dry Chem ABC
CAT Dozers 1 D-6 Dry Chem ABC
2 D-7 - Behind seat Dry Chem ABC SW-0.7 3# NA
3 D-8 - Behind seat Dry Chem ABC AU-226391 5# 23-May 18-Feb Lorain LTR 300D
1 Cab behind seat Dry Chem ABC AG-566639 3# 19-May
CAT 330 - 1
1 Cab behind seat Dry Chem ABC B-74188006 10# 23-May 2022-Mar
CAT 330C - 40455-2
1 Battery compartment Dry Chem ABC ZT-905397 5# 20-Jan 2015-Jan
CAT 395
Connex
Welding Connex 1 Red-By door Dry Chem ABC CC-951945 10# 21-Aug 21-Aug 2 Red-By door Dry Chem ABC CC-951953 10# 21-Aug 21-Aug 3 Green- Floor by door Dry Chem ABC CC-951967 10# 23-May 20-Jul
Paint Connex 1 Inside on floor/Needs replaced Dry Chem ABC VR-485337 20# 2022
2 Suppression system Dry Chem ABC IND-45 45# 2023
Wade
1 Entry door outside Dry Chem ABC ZR-49012 10# 23-May 20-Jul
Notes:
The U.S. Army Corps of Engineers as an agency of the Federal Government is tax exempt. Tax ID# 62-1642142.
(End of Summary of Changes)