Water Valve Leak Mitigation
Closed Pre-Solicitation Posted
- Solicitation number
- FMP-NNL-0047
- Agency
-
Department of Energy
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- Place of performance
- United States
- Points of contact
-
- Atip atip@unnpp.gov
Notice details come from SAM.gov. Updated .
About this opportunity
The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion, is conducting market research through a request for information due September 3, 2026, to identify organizations capable of mitigating water valve leakage in pure water fluid systems during maintenance operations. This is a request for information only and does not constitute a solicitation; no costs will be reimbursed.
The requirement seeks methods to prevent valve leak-by during maintenance windows or welding operations lasting hours to days. Solutions must not compromise pure water chemistry or affect stainless-steel corrosion or cracking performance. The method must be external to the system, completely dissolve into known constituents at room temperature, or otherwise remain non-intrusive; devices or materials requiring removal after repair are not acceptable. Current mitigation relies on freeze seals, which consume substantial labor and resources.
Respondents should limit submissions to five pages. The work falls under NAICS 54171 (Research and Development in the Physical, Engineering, and Life Sciences) and PSC AG12 (Energy R&D Services; Energy Supply; Applied Research). No set-aside is anticipated. Interested parties should respond to NNL by the September 3 deadline for consideration in future procurement planning.
Notice text
THIS IS A REQUEST FOR INFORMATION ONLY. THIS IS NOT A SOLICITATION.
This notice is issued solely for informational and planning purposes. This notice does not constitute a solicitation. The Naval Nuclear Laboratory (NNL), operated by Fluor Marine Propulsion (FMP), is utilizing this request for information for market research to determine what organizations have the capability to fulfill this requirement. NNL will not be responsible for any costs incurred by interested parties in responding to this request for information.
Responses shall not exceed five (5) pages in length.
Scope:
When performing maintenance on a pure water fluid system, valves are commonly used for work area isolation. Valves that have been in-service can leak past their seats. In this case, the worker may still be protected from hazardous energy on the other side of the valve but work such as welding might not be possible if water is being continually introduced to the work area. In this case, more valves can be used if available in the system design, but if not, freeze seals are commonly used to eliminate leakage. Freeze seals can consume significant work and resources to set, so alternate means to mitigate water leakage past valves is desired.
A method to mitigate valve leak-by for the hours or days a system is open for maintenance or the time to perform a weld is desired which will not affect pure water chemistry or stainless-steel corrosion or cracking performance. The method must not introduce devices or materials that require removal from the system after repair is completed. Solutions must either be external to the system, completely dissolve into known and consistent constituents at room temperature, or otherwise non-intrusive.
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Stem, fluid valve | Naval Supply Systems Command | No set-aside | |
| Stem, fluid valve | Naval Supply Systems Command | No set-aside | |
| Stem, fluid valve | Naval Supply Systems Command | No set-aside | |
| Valve assy flood LE | Naval Supply Systems Command | No set-aside | |
| Stem, fluid valve | Naval Supply Systems Command | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity