Tissue Processor
Award Notice Posted
- Solicitation number
- VA25817N0125
- Agency
-
Veterans Integrated Service Network 22
Veterans Health Administration, Department of Veterans Affairs
- Awarded
- to Catamount Research And Development Inc.
- Set-aside
- Total Small Business
Opportunity facts
- Contract number
- VA25817P0708 Federal contract award
- NAICS code
- 541712 Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
- PSC
- Not on record
- Place of performance
- Phoenix VA Medical Center 650 E. Indian School Rd. Phoenix, AZ 85012 USA
Notice details come from SAM.gov. Updated .
Notice text
Added: Dec 13, 2016 6:10 pm
Statement of Work
Linear Alignment Single Vessel Chamber
Phoenix Veterans Administration Health Care Services
650 E. Indian School Road
Phoenix, AZ 85012
1.0 Background
The purpose of this Statement of Work (SOW) is to procure an expansion to previously purchased equipment. This includes a specialized a tissue perfusion chamber.
The perfusion bath attaches via various connectors, tubing, and wiring to an (already owned) arteriography system that allows for the fine and precise measurement of small vascular tissues while keeping the tissue alive and active in conditions similar to what it would have within the body.
This service is in support of Laboratory research projects. This service is required to extend the capabilities of current workflow restrictions due to a lack of enough Vascular Perfusion chambers and attached Thermistor Controllers for regulating their temperature.
The Purchase needs to include:
3.000 EA CH-1-LIN Linear Alignment Single Vessel Chamber from Living Systems (Catamount Research and Development)
2.0 Tasks: The contractor shall provide all personnel, materials, and equipment required for tasks outlined in this SOW.
In accordance with Appendix A, Handbook 6500.6 Checklist blocks 6, the C&A requirements do not apply to this requirement, and a Security Accreditation Package is not required. Due to the non-technical nature of this requirement, in reference to no. 7 there is no information to be protected.
This product does not capture or produce PII or PHI. There is no storage mechanism in the equipment or software per the Research Privacy Officer.
The period of performance is 30 days after receipt of award.
3.0 Shipping and Delivery: All materials required for this training shall be shipped to the following location: Listed in 1449
Files
| File | Type | Posted |
|---|---|---|
| VA258-17-N-0125-004.docx | DOCX document | |
| VA258-17-N-0125-003.docx | DOCX document |