Standby Generator
Closed Solicitation Posted
- Solicitation number
- W911S225U1698
- Agency
-
MICC Fort Drum
Mission and Installation Contracting Command, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 335312 Motor and Generator Manufacturing
- Place of performance
- 6650 Meloy Dr, Fort Benning, GA 31905 31905
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army Materiel Command Mission and Installation Contracting Command Fort Drum is seeking to procure one 100 kW dual fuel standby generator through this solicitation. The procurement requires a complete engine-driven generator set that is factory built, production-tested, and site-tested, including the engine generator set, enclosure, and all related accessories necessary for complete installation. The equipment must be new, of current production, and supplied by a power system manufacturer that can provide single-source responsibility for warranty, parts, and service through factory-authorized representatives with factory-trained technicians. All equipment must comply with the National Electrical Code, applicable local codes, and numerous industry standards including CSA C22.2, EN50082-2, EN55011, IEC8528, IEEE446, and NFPA 70 and 110. The solicitation notice indicates this is an amendment to increase information for more accurate requirements, with proposals due by September 2, 2025.
This opportunity is designated as a Total Small Business set-aside, restricting participation to qualified small business entities. The contract falls under NAICS code 335312 for Motor and Generator Manufacturing and PSC category 6115 for Generators and Generator Sets, Electrical. The place of performance is specified as Meloy Drive, Columbus, Georgia 31903, indicating where the generator installation will take place. The solicitation emphasizes the requirement for a complete generator set system of commercial design with all necessary accessories for full installation. No incumbent contractors, award values, or specific budget ranges are mentioned in the available solicitation details.
Notice text
2 versions
Update #2 · Latest ·
Reason for Amendment is to increase information for more accurate requirements.This section includes the following items from a single supplier: 1.Engine Generator Set. 2. Enclosure 3. Related Accessories as specified1. It is the intent of this specification to secure an engine-driven generator set that has been factory built, production-tested, and site-tested together with all accessories necessary for a complete installation as shown on the drawings and specified herein.2. Any exceptions to the published specifications shall be subject to the approval of the Governing agency.3. It is the intent of this specification to secure a generator set system. The generator set will be a commercial design and will be complete with all the necessary accessories for complete installation.4. The equipment supplied shall meet the requirements of the National Electrical Code and applicable local codes and regulations.5. All equipment shall be new and of current production by a power system manufacturer of generators, transfer switches, and switchgear. There will be single-source responsibility for warranty, parts, and service through a factory-authorized representative with factory-trained technicians.The generator set shall conform to the requirements of the following codes and standards: CSA C22.2, No. 14-M91 Industrial Control Equipment.; EN50082-2, Electromagnetic Compatibility-Generic Immunity Requirements, Part 2: Industrial.; EN55011, Limits and Methods of Measurement of Radio Interference Characteristics of Industrial, Scientific and Medical Equipment.; IEC8528 part 4, Control Systems for Generator Sets.; IEC Std 61000-2 and 61000-3 for susceptibility, 61000-6 radiated and conducted electromagnetic emissions.; IEEE446 Recommended Practice for Emergency and Standby Power Systems for Commercial and Industrial Applications.; NFPA 70, National Electrical Code, Equipment shall be suitable for use in systems in compliance to Article 700, 701, and 702.; NFPA 110, Emergency and Standby Power Systems. The generator set shall meet all requirements for Level 1 systems. Level 1 prototype tests required by this standard shall have been performed on a complete and functional unit.; Component level type tests will not substitute for this requirement.100 kW Generator Dual Fuel Standby Generator [120/208 3 phase (1200 amp main)]; Standby Startup needed; load banking is needed; Type of Enclosure is NEMA 3R Rated; No tank required, natural gas is available at the site; EPA Tier 5 certification is required; Receiving facility and forklift available, so no offloading required. Battery and Battery Charger required. Automatic Transfer Switch: NEMA 3R Rated; service entrance desired; What will be the mechanism? service entrance; What will be the transition? It will be standard, programmed, and closed.
Update #1 ·
1 x 100 kW Generator Dual Fuel Standby Generator
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Generator, alternating | Land and Maritime | Total Small Business | |
| Generator, alternating | Land and Maritime | Total Small Business | |
| Generator, alternating | Land and Maritime | Total Small Business | |
| Generator, alternating | Land and Maritime | Total Small Business | |
| Diesel Engine, Starter Motor, Magnetic Contactors, Powerpack & Alternators Supporting 800kW, 60 Hz DPGDS - Non-Commercial NSN's | Land and Maritime | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity