Spray Foam Insulation of Lock & Dam 5 Control Booth

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W912ES23Q0081
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Minnesota City, Minnesota 55959, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers - St. Paul District is seeking a contractor to install spray foam insulation in the Lower Control Stand at Lock & Dam 5. The contractor will be responsible for supplying all necessary equipment, labor, and materials to install the insulation in accordance with local building codes, and must possess a current industry-recognized accreditation or certification for high-pressure spray polyurethane foam insulation. The contractor will also be required to warranty the work for one year.

Products and Services to be provided:

  1. Installation of spray foam insulation in the ceiling and all four walls of the Lower Control Stand at Lock & Dam 5.
  2. Supply of all equipment necessary for the installation.
  3. Supply of all labor necessary for the installation.
  4. Supply of all materials necessary for the installation.
  5. Warranty for the work for one year.

Notice text

The U.S. Army Corps of Engineers - St. Paul District seeks a contractor to iInstall spray foam insulation in the ceiling and all four walls with closed cell Sprayed Polyurethane Foam (SPF) insulation in the Lower Control Stand at Lock & Dam 5. The Contractor shall supply all equipment, labor, and materials necessary to install new closed cell (SPF) insulation in accordance with local building codes. Apply 4” foam thickness to the underside of the roof panels and 3” foam thickness at the walls. The buildings inside dimensions are 11’-8” x 8’-8” x 7’3” tall. The existing walls are pre-cast concrete with 3” metal framing. The underside of the roof will be accessed through the rough opening at the existing light fixture.

Contractor shall posses a current industry recognized professional accreditation or certification for high pressure spray polyurethane foam insulation. Documentation must be provided to the Contracting Officer’s Representative (COR) at the pre-work conference. Contractor shall warranty work for one year.

The Government recommends a site visit prior to quoting the work.

This solicitation is a Request for Quotes (RFQ). Bid Bonds are NOT required. The preferred method for submitting quotes is electronically by emailing a PDF attachment of the signed SF1442 to John.P.Riederer@usace.army.mil

This solicitation is 100% Set-Aside for Small Business.

Amendments (if any) may be acknowledged by completing Block 19 on the SF1442, or submitting a signed copy of the SF30 Amendment form.

Offerors must be fully registered in the System for Award Management (SAM), to include applicable FAR and DFARS Representations and Certifications. Offers will not be considered from entities without a current SAM registration.
 

Files

File Type Posted
W912ES23Q0081 RFQ for LD5 Control Booth Insulation.pdf PDF

Notice history

Notice Type Posted
Spray Foam Insulation of Lock & Dam 5 Control Booth Award Award Notice
This notice Latest solicitation Solicitation

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity