Recovery/Recycle system for NOVEC 1230 Fire Extinguisher

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
FA5270-24-Q-A056
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Kadena AB Okinawa Japan

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks capability information for a recovery/recycle system for NOVEC 1230 fire extinguishers. The 18th Contracting Squadron at Kadena Air Base, on behalf of the 18th Civil Engineer Group, requires a maintenance system to service NOVEC 1230 flightline extinguishers every six years per NFPA 408 standards. The system must transfer liquid and vapor NOVEC 1230 at specified rates, filter particulate matter, indicate moisture, and operate on compressed air between 100-120 PSI at minimum 13 CFM. Respondents must submit company information and if offering an equivalent item, detailed product information by March 20, 2024.

There is no set-aside designated for this requirement. The incumbent contractor is GETZ Equipment Innovators, model 4G59754. Respondents must have the capability to provide one recovery/recycle system. Key details include the need to service extinguishers containing 16 pounds of NOVEC 1230 liquid per minute and 2 pounds of vapor per minute, with 4 adapters.

Notice text

The 18 Contracting Squadron (18 CONS) is issuing this source sought synopsis as a means of conducting market research to identify parties are capable of providing the required item as described below. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for quotations; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred.

The 18th Civil Engineer Group (18 CES/CEF), Kadena Air Base, had identified a need for a maintenance system for NOVEC 1230 flightline extinguishers. The NOVEC 1230 flightline fire extinguishers are required to be serviced every six years to be compliant with NFPA 408, standards for aircraft hand portable fire extinguishers. 

SPECIFIC INFORMATION OF INTEREST/SALIENT CHARACTERISTICS

Item: Recovery/Recycle System for NOVEC 1230 Fire Extinguisher

Mfg:  GETZ Equipment Innovators

Item #: 4G59754

Qty: 1

Unit of Issue: Each

-Transfer liquid, vapor, and nitrogen

-NOVEC 1230 Liquid transfer rate of 16lbs per minute maximum

-NOVEC 1230 vapor transfer rate of 2lbs per minute maximum

-Filters particulate matter

-Indicates moisture

-Operates on compressed air pressure between 100-120 PSI at a minimum of 13 CFM

-Includes 4 adapters

**OR EQUAL ITEM**

If your company is capable of providing this requirement, please submit the following information:

1) Company name, address, point of contact, email address, website address, telephone number, and cage code, UEI, and product information. 

2) If your company is capable of proving an equal item, please attach the item information in detail. 

Notice history

Notice Type Posted
Recovery/Recycle system for NOVEC 1230 Fire Extinguisher Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
NRP, bottle FE-36 HI, in repair/modification of Naval Supply Systems Command No set-aside
Nitrogen Generator NAICS 334516 Air Force Sustainment Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity