Recovery-replacement of HVAC equipment
Award Notice Posted
- Solicitation number
- I1760090003
- Agency
-
National Park Service
Department of the Interior
- Awarded
- to Kgci Inc.
- Set-aside
- Competitive 8(a)
Opportunity facts
- Contract number
- INPC1760090003 Federal contract award
- NAICS code
- Not on record
- PSC
- Not on record
- Place of performance
- Fort Stanwix National Monument-Rome-New York 13440 USA
Notice details come from SAM.gov. Updated .
Notice text
3 versions
Update #3 · Latest ·
This Amendment 2 under I1760090003 is to sysnopsis a Replacement of HVAC Equipment project for Fort Stanwix National Monument-Rome-New York under National Park Service-US Department of the Interior.
This project is RECOVERY and NAICS is 238220.
The work of this contract consists of the replacement and modifications to the existing HVAC equipment and systems at Fort and Maintenance Shop located at Fort Stanwix National Monument.
Contractor will be required to provide all labor, supplies, equipment, tools, materials, all supplementary or miscellaneous items, appurtenances and devices incidental to or necessary to perform work.
GENERAL REQUIREMENT
A. FORT
1. Disconnect and remove existing Split System, Cooling only 3 (three) Air Handling Units and 2 (two) associated Condensers, refrigerant piping, and all appurtenances. Furnish and install 3 (three) new high efficiency Split System (Cooling only) Air Handling units and 2 (two) associated condensers, refrigerant piping, and all appurtenances, disconnects, controls, wiring, and miscellaneous items necessary for complete and operational HVAC Systems in place of the removed ones.
2. Reclaim and dispose of used refrigerant as required by applicable laws and regulations.
B. MAINTENANCE SHOP
1. Furnish and install new ductless Split Type, Tri-Zone (3 Indoor Units/1 Outdoor Unit) 27,000 BTUH total capacity Heat Pump System complete with refrigerant piping and all components and accessories. Outdoor Unit shall be located in wooden shed on the Office side of Maintenance Shop. Furnish and install three (3) new ceiling-mounted high efficiency gas-fired unit heaters including all appurtenances.
2. Disconnect and remove three (3) existing ceiling-mounted gas-fired unit heaters including all related accessories.
3. Restore heating system to fully functional working order.
C. PERIOD OF PERFORMANCE
Contractor will be required to complete all work within ninety (90) calendar days after receipt of notice to proceed.
D. DEMOLITION
1. Disposal of removed equipment and materials shall be the Contractor's responsibility.
E. Magnitude of this project is between $25,000 to $100,000.00.
F. This procurement is 8(a) set aside competition.
Should you have any questions concerning about this project, feel free to submit your questions to Diemhong_Walters@nps.gov.
Update #2 ·
Purpose of this announcement is to cancel previous annoucement number I1760090003 until further notice.
Update #1 ·
DESCRIPTION:
RECOVERY
NAICS: 238220
The work of this contract consists of the replacement and modifications to the existing HVAC equipment and systems at Fort and Maintenance Shop located at Fort Stanwix National Monument.
Contractor will be required to provide all labor, supplies, equipment, tools, materials, all supplementary or miscellaneous items, appurtenances and devices incidental to or necessary to perform work.
GENERAL REQUIREMENT
A. FORT
1. Disconnect and remove existing Split System, Cooling only 3 (three) Air Handling Units and 2 (two) associated Condensers, refrigerant piping, and all appurtenances. Furnish and install 3 (three) new high efficiency Split System (Cooling only) Air Handling units and 2 (two) associated condensers, refrigerant piping, and all appurtenances, disconnects, controls, wiring, and miscellaneous items necessary for complete and operational HVAC Systems in place of the removed ones.
2. Reclaim and dispose of used refrigerant as required by applicable laws and regulations.
B. MAINTENANCE SHOP
1. Furnish and install new ductless Split Type, Tri-Zone (3 Indoor Units/1 Outdoor Unit) 27,000 BTUH total capacity Heat Pump System complete with refrigerant piping and all components and accessories. Outdoor Unit shall be located in wooden shed on the Office side of Maintenance Shop. Furnish and install three (3) new ceiling-mounted high efficiency gas-fired unit heaters including all appurtenances.
2. Disconnect and remove three (3) existing ceiling-mounted gas-fired unit heaters including all related accessories.
3. Restore heating system to fully functional working order.
C. PERIOD OF PERFORMANCE
Contractor will be required to complete all work within ninety (90) calendar days after receipt of notice to proceed.
D. DEMOLITION
1. Disposal of removed equipment and materials shall be the Contractor's responsibility.
E. Magnitude of this project is between $25,000 to $100,000.00.
F. This procurement is 8(a) set aside competition.