Piston Ring Replacement, Hydraulic Gates, Blackwater Dam, Webster, NH

Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
W912WJ23Q0005
Agency
Responses due
Not on record
Set-aside
Total Small Business

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice is for piston ring replacement services for the hydraulic gates at Blackwater Dam in Webster, New Hampshire. The U.S. Army Corps of Engineers - New England District seeks to minimize ongoing fluid slip and gate drift issues by removing and replacing the middle piston rings on each of the six service gates and three emergency gates with new hydrolysis-resistant polyurethane seals. The solicitation and full contract documents will be available on March 7, 2023 on SAM.gov, with responses due by an unspecified future date. The evaluation criteria will focus on experience performing similar hydraulic gate maintenance and safety compliance.

This procurement is set aside for total small business vendors. The NAICS code is 237990 for other heavy and civil engineering construction with a small business size standard of $45 million. The magnitude of construction is estimated between $100,000 to $250,000. Vendors must have an active SAM.gov registration by the response deadline to be considered for award.

Notice text

The U.S. Army Corps of Engineers – New England District is issuing a Pre-Solicitation Notice for Piston Ring Replacement, Hydraulic Gates, Blackwater Dam, Webster, NH

THE WORK CONSISTS OF:

The goal of this project is to minimize the ongoing hydraulic fluid slip, which is consequently allowing the operating gates to drift from their specified height. The project includes, but is not limited to, the removal and replacement of the middle piston ring for each gate (three service, three emergency) and replacement with a new hydrolysis-resistant polyurethane piston seal manufactured to operate within the specified hydraulic fluid type, pressure, & temperatures. The Contractor shall note that only one gate at a time may be worked on until the repair work is complete.

The outlet works are incorporated within the spillway and consist of three conduits located through the deep section of the spillway adjacent to the non-overflow section. Access to the gates is by a stairway from the equipment operating room and then through a gallery. Flow through each conduit is controlled by a hydraulically operated gate; additionally each gate is also equipped with a hydraulically operated emergency gate. All gates are operated by hydraulic pumps located in the equipment room. Flow through the conduit passes back into the natural river channel. During normal operation all gates are maintained at a 3-foot opening. Air vents are provided for both the service and emergency gates.  

There is an onsite 2-ton monorail hoist located in the operating room that will be available for use; however, the Contractor shall be required to provide an annual inspection certificate and conduct operational testing prior to use.  Existing anchor points are located above the gate cylinders in the gallery. Similar to the monorail hoist, the Contractor shall be required to conduct operational testing prior to use. 

The gate chamber (gallery) is considered a Non-Permit Required Confined Space. If work execution in the gate chamber creates an atmospheric hazard, the gate chamber will be reclassified as a Permit-Required Confined Space.

The magnitude of construction is between $100,000 and $250,000

This is not a request for quotes at this time.  The solicitation requirements and contract documents, to include instructions for submission, and the response date will be available on or about March 7, 2023.  Neither telephonic, mailed nor faxed requests for hard copies of this solicitation will be accepted.  The solicitation will only be available online; in order to download the solicitation offerors must access the Contract Opportunities website (www.SAM.gov). 

This procurement is set-aside for small business vendors. The applicable NAICS code is 237990 with a Small Business Size Standard of $45 Million.

ALL VENDORS MUST HAVE AN ACTIVE REGISTRATION IN SAM.GOV AT THE TIME OF SUBMISSION IN ORDER TO BE CONSIDERED. ANY VENDOR THAT DOES NOT HAVE AN ACTIVE SAM.GOV REGISTRATION WILL BE REJECTED AS NON RESPONSIVE.

Notice history

Notice Type Posted
Piston Ring Replacement, Hydraulic Gates, Blackwater Dam, Webster, NH Award Award Notice
Piston Ring Replacement, Hydraulic Gates, Blackwater Dam, Webster, NH Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Float Well Pipe Repairs, Surry Mountain Dam, Surry, NH Surry, New Hampshire, United States · NAICS 237990 ENDIST New England No set-aside
W9127N27BA005 Foster Spillway Gate Nut Replacements and Re-Tensioning Foster Dam, Linn County, Oregon 93745 · NAICS 237990 ENDIST Portland Total Small Business
Dike B Generator Installation, Mansfield Hollow Dam, Mansfield Center, CT Mansfield Center, Connecticut, United States · NAICS 238290 ENDIST New England Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity