Install 800MHZ Repeater for Security 515-21-202

Closed Solicitation Posted

Solicitation number
36C25022B0043
Agency
Veterans Integrated Service Network 10 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z1DA Maintenance Of Hospitals And Infirmaries
Place of performance
Battle Creek, Michigan 49037, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is soliciting proposals to furnish all labor, materials, equipment, supervision, documentation and related services to complete Project 515-21-202. This project involves removing existing emergency responder distributed antenna system components from multiple buildings and installing new 800MHz cabling and repeaters campus-wide at the VA Medical Center in Battle Creek, Michigan. The objective is to increase the facility's 800MHz radio frequency coverage for security services. Proposals are due by July 21, 2022 at 2:00pm EST. Evaluation will be based on technical qualifications, past performance and price.

This set-aside opportunity is designated for Service-Disabled Veteran-Owned Small Businesses. The primary NAICS code is 237130 and PSC code R499. The contractor shall have 540 days to complete the installation once awarded. The place of performance is the VA Medical Center campus located in Battle Creek, Michigan. The magnitude of construction is valued between $500,000 and $1,000,000.

Notice text

The Contractor shall furnish all labor, material, equipment, supervision, As-Built Documentation, and all other related information for Project 515-21-202, Install 800MHZ Repeater for Security Service, at the VA Medical Center in Battle Creek, Michigan. This project includes removal and installation of cabling and repeaters campus wide to increase Battle Creek VA Medical Center’s 800MHZ service. The contractor will receive a total of 540 days to complete the work.

Attachments

Files attached to this notice, newest first
File Type Posted
36C25022B0043 Amendment 0004.pdf PDF
36C25022B0043 Amendment 0003.pdf PDF
36C25022B0043 Amendment 0002.pdf PDF
02-EP.101 - BUILDING 02 - FIRST FLOOR POWER PLAN.pdf PDF
02-EP.100 - BUILDING 02 - BASEMENT POWER PLAN.pdf PDF
36C25022B0043 Amendment 0001.pdf PDF
Project 515-21-202 Drawings.pdf PDF
RFI Form Solicitation.doc DOC document
Project 515-21-202 Specifications.pdf PDF
Project 515-21-202 SOW.pdf PDF
36C25022B0043.pdf PDF
Wage Determination MI20220100.pdf PDF
Show all 12

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Install 800MHZ Repeater for Security 515-21-202 This notice · Latest solicitation Solicitation
Install 800MHZ Repeater for Security 515-21-202 Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity