Hangar 2 Annex B Project
Awarded Award Notice Posted
- Solicitation number
- N6247320R0032
- Agency
- Naval Facilities Engineering Command Department of the Navy, Department of Defense
- Awarded
- to Adamo Construction Inc.
- Set-aside
- No set-aside
Opportunity facts
- Contract number
- N6247320C0615 Federal contract award
- NAICS code
- 236210 Industrial Building Construction
- Place of performance
- Fallon NV 89496 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This Award Notice from the Department of the Navy Naval Facilities Engineering Command selects Adamo Construction Inc. for a $1,996,697 design-build contract to renovate approximately 1,591 square feet of office space at Hangar 2 into four secure rooms complying with ICD/ICS 705 security specifications and UFC 4-010-05. The contractor will replace flooring and ceilings, renovate finishes, relocate lighting and HVAC, and provide a two-year security accreditation for the completed secure facility, with all work to be completed by September 2020.
Notice text
This is a Design Build project. The section of Hangar 2 office area that requires renovation is approximately 15’-2” x 104’10.5” or 1,591 square feet. The renovation and upgrade is to comply with the latest editions of IC Tech Spec requirements for ICD/ICS 705 security specifications and the Unified Facilities Criteria (UFC) 4-010-05 – Sensitive Compartmented Information Facilities Planning, Design, and Construction.
This is a Design/Build project. The contractor will provide all services and materials (including all ancillary work) to produce a complete and usable area/project as specified below.
In general, the Contractor shall:
- Design a room layout in accordance with the schematic layout presented in the RFP. Remodel/Renovate/Reconstruct/Construct the rooms in accordance with the requirements of the Unified Facilities Criteria, the latest editions of IC Tech Spec requirements for ICD/ICS 705 security specifications and specifically, the Unified Facilities Criteria (UFC) 4-010-05 – Sensitive Compartmented Information Facilities Planning, Design, and Construction.
- Replace flooring with luxury vinyl tile.
- Replace ceiling grid and panels
- In general, renovate spaces with new paint/ texture and finishes. Relocate/add lighting, fire sprinklers, HVAC ducting, as needed, to comply with applicable governing codes.
- There will be a Construction Security Plan (CSP) in place approved by an Accrediting Official. The contractor will be provided a copy and must adhere to the security provisions in the CSP.
- None of the rooms associated with this project are security certified by an Approving Official.
- The Contractor will be required to perform as/subcontract an Electronic Security System certified company for installation of the security system. Specifications will be provided by the customer.
- In addition to the above requirement, the Contractor will provide an additional two (2) years of certified security accreditation for the completed project secure facility.
- The Contractor will contract directly with the Base Operations Support Contractor (BOSC) for any required “contractor assist” tasks. Contact information will be provided after award.
- If no existing conduits are available for the installation of the 48-strand optical fiber backbone, and trench excavation is the only option, the Contractor will develop a route and excavation plan for government approval before digging. The Contractor will be allowed to “jack and bore” under the roadways and trench through the parking lots.
- If excavating, all applicable Environmental regulations apply, include, but not limited to, dig permits, and the SWPP plan permit.
- A Contractor layout yard, if needed, field compound will be provided during the design phase.
Specific Project Requirements:
- All rooms are to be considered “auditorium type” with amplified voice. Therefore, the perimeter wall is to be designed as Sound Group 4 – STC 50 rating or better.
- The perimeter doors are to be STC 50 or better.
- The entrance door is to include a CDX-10 lock with an included keypad.
- Remove existing flooring and install Luxury Vinyl Tile throughout the space.
- Electrical design considerations – in addition to the required electrical outlets, provide electrical and structural support for video screen mounting for all four walls in each rooms. Provide monitors (amount and size) as described in RFP Part 6 attachments
- The electrical supply panel is located across the hallway from the project. Include in the design, as needed, a new ICD 705 service panel and associated electrical appurtenances in accordance with the ICD 705 specifications.
- HVAC – provide HVAC modifications as needed with respect to ICD 705 requirements.
- Provide a complete network infrastructure (4 rooms) in accordance with the information provided in Part 6.
Awarded contract N6247320C0615 to Adamo Construction Inc. for 1996697.00 on 2020-04-22.
Attachments
| File | Type | Posted |
|---|---|---|
| N6247320C0615 released.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Hangar 2 Annex B Project | Award Notice | |
| SAPF Space in Hangar 2 | Limited / Sole Source Justification |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity