Fort Randall Motor Control Center
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W9128F20Q0002
- Agency
- ENDIST Omaha US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 335313 Switchgear and Switchboard Apparatus Manufacturing
- PSC
- 6110 Electrical Control Equipment
- Place of performance
- Pickstown SD 57367 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks proposals to fabricate, assemble, deliver, install and test approximately twenty-two motor control centers and five panel boards at the Fort Randall Powerhouse in Pickstown, South Dakota. The U.S. Army Corps of Engineers Omaha District is procuring these goods and services with a period of performance of 547 calendar days from award. Offerors must meet technical specifications for voltage ratings from 120V to 480V and interrupt ratings from 14,000 to 42,000 amps. The primary NAICS code is 335313 and proposals are due through the Beta SAM portal by various amended deadlines.
The requirement has a total small business set-aside designation. The primary NAICS code is 335313 for switchgear and switchboard apparatus manufacturing with a small business size standard of 1,250 employees. The place of performance is the Fort Randall Powerhouse in Pickstown, South Dakota. Key details include supplying and installing approximately twenty-two motor control centers and five panel boards over 547 days. Questions are due by amended deadlines to the contracting specialist at the U.S. Army Corps of Engineers Omaha District, which is the contracting office.
Notice text
3 versions
Update #3 · Latest ·
***Amendment 0002 - Please review amendment to review the Summary of Changes. The Due Date for Quotes has been moved to 28 May 2020 by 2:00 PM CT.
***Amendment 0001 - Please review amendment for the update to the Virtual Site Visit and acknowledge AM0001 when submitting the quotes.
Project Description:
This is a supply/install hybrid project to fabricate, assemble, deliver, install and test approximately twenty-two (22) Motor Control Centers (MCCs) and five (5) Panel Boards (PBs). These are both AC and DC motor controls centers with voltage ranging from 120V to 480V and interrupt ratings ranging from 14,000 Amps to 42,000 Amps. Motor Control Centers are defined as distribution center with associated controls, switches, indicating lights...etc. Many of the MCCs to be replaced under this contract do not contain any or have minimal controls. In these cases, the Contractor may choose to provide a free-standing switchboard in lieu of a MCC as long as all the requirements for voltage, ampacity, interrupt ratings, arc flash reduction requirements, size restrictions, main circuit breakers, branch circuit breakers, reconnection of existing circuits....etc. are met by the substitution of a switchboard for a MCC.
The Period of Performance for this effort is for 547 days from date of award.
NAICS Code:
The Primary North American Industry Classification System (NAICS) code for this solicitation is 335313- Switchgear and Switchboard Apparatus Manufacturing, with a size standard for Small Business of 1,250 employees.
Obtaining Solicitation Documents:
Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov).
Find solicitation announcement in Beta SAM.gov (beta.sam.gov).
Use the ‘All Award Data' to locate the project (by entering the solicitation number.
By using the ‘login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted.
Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the left side reading ‘Attachments/Links’.
Contracting Office Address:
USACE Omaha District
1616 Capital Ave, Omaha, NE 68102-4901
Point Of Contact:
All questions regarding this pre-solicitation should be made to the Contract Specialist, who can be reached by email: lynne.d.reed@usace.army.mil .
Location of Installation of Motor Control Centers and Panel Boards:
Fort Randall Powerhouse, Pickstown, SD
Note: Offerors please be advised that an online registration requirement in System for Award Management (SAM) database http://www.sam.gov/ exists and directed solicitation provisions concerning electronic annual Representations and Certifications on SAM. Representations and certifications are required to be up-dated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective for one year from date of submission or update to SAM. Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov). Registration is required to access solicitation documents. Beta SAM.gov provides secure access to acquisition-related information, synopsis or pre-solicitation notices and amendments.
Update #2 ·
***Amendment 0001 - Please review amendment for the update to the Virtual Site Visit and acknowledge AM0001 when submitting the quotes.
Project Description:
This is a supply/install hybrid project to fabricate, assemble, deliver, install and test approximately twenty-two (22) Motor Control Centers (MCCs) and five (5) Panel Boards (PBs). These are both AC and DC motor controls centers with voltage ranging from 120V to 480V and interrupt ratings ranging from 14,000 Amps to 42,000 Amps. Motor Control Centers are defined as distribution center with associated controls, switches, indicating lights...etc. Many of the MCCs to be replaced under this contract do not contain any or have minimal controls. In these cases, the Contractor may choose to provide a free-standing switchboard in lieu of a MCC as long as all the requirements for voltage, ampacity, interrupt ratings, arc flash reduction requirements, size restrictions, main circuit breakers, branch circuit breakers, reconnection of existing circuits....etc. are met by the substitution of a switchboard for a MCC.
The Period of Performance for this effort is for 547 days from date of award.
NAICS Code:
The Primary North American Industry Classification System (NAICS) code for this solicitation is 335313- Switchgear and Switchboard Apparatus Manufacturing, with a size standard for Small Business of 1,250 employees.
Obtaining Solicitation Documents:
Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov).
Find solicitation announcement in Beta SAM.gov (beta.sam.gov).
Use the ‘All Award Data' to locate the project (by entering the solicitation number.
By using the ‘login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted.
Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the left side reading ‘Attachments/Links’.
Contracting Office Address:
USACE Omaha District
1616 Capital Ave, Omaha, NE 68102-4901
Point Of Contact:
All questions regarding this pre-solicitation should be made to the Contract Specialist, who can be reached by email: lynne.d.reed@usace.army.mil .
Location of Installation of Motor Control Centers and Panel Boards:
Fort Randall Powerhouse, Pickstown, SD
Note: Offerors please be advised that an online registration requirement in System for Award Management (SAM) database http://www.sam.gov/ exists and directed solicitation provisions concerning electronic annual Representations and Certifications on SAM. Representations and certifications are required to be up-dated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective for one year from date of submission or update to SAM. Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov). Registration is required to access solicitation documents. Beta SAM.gov provides secure access to acquisition-related information, synopsis or pre-solicitation notices and amendments.
Update #1 ·
Project Description:
This is a supply/install hybrid project to fabricate, assemble, deliver, install and test approximately twenty-two (22) Motor Control Centers (MCCs) and five (5) Panel Boards (PBs). These are both AC and DC motor controls centers with voltage ranging from 120V to 480V and interrupt ratings ranging from 14,000 Amps to 42,000 Amps. Motor Control Centers are defined as distribution center with associated controls, switches, indicating lights...etc. Many of the MCCs to be replaced under this contract do not contain any or have minimal controls. In these cases, the Contractor may choose to provide a free-standing switchboard in lieu of a MCC as long as all the requirements for voltage, ampacity, interrupt ratings, arc flash reduction requirements, size restrictions, main circuit breakers, branch circuit breakers, reconnection of existing circuits....etc. are met by the substitution of a switchboard for a MCC.
The Period of Performance for this effort is for 547 days from date of award.
NAICS Code:
The Primary North American Industry Classification System (NAICS) code for this solicitation is 335313- Switchgear and Switchboard Apparatus Manufacturing, with a size standard for Small Business of 1,250 employees.
Obtaining Solicitation Documents:
Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov).
Find solicitation announcement in Beta SAM.gov (beta.sam.gov).
Use the ‘All Award Data' to locate the project (by entering the solicitation number.
By using the ‘login' feature, it allows additional search features and allows you to keep your searches. Login might be required on some solicitations that are considered restricted.
Once you have located your project, click on link to solicitation to view the project. Files may be downloaded from the column on the left side reading ‘Attachments/Links’.
Contracting Office Address:
USACE Omaha District
1616 Capital Ave, Omaha, NE 68102-4901
Point Of Contact:
All questions regarding this pre-solicitation should be made to the Contract Specialist, who can be reached by email: lynne.d.reed@usace.army.mil .
Location of Installation of Motor Control Centers and Panel Boards:
Fort Randall Powerhouse, Pickstown, SD
Note: Offerors please be advised that an online registration requirement in System for Award Management (SAM) database http://www.sam.gov/ exists and directed solicitation provisions concerning electronic annual Representations and Certifications on SAM. Representations and certifications are required to be up-dated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective for one year from date of submission or update to SAM. Solicitation documents will be posted to the web via Beta SAM.gov (beta.sam.gov). Registration is required to access solicitation documents. Beta SAM.gov provides secure access to acquisition-related information, synopsis or pre-solicitation notices and amendments.
Attachments
Notice history
| Notice | Type | Posted |
|---|---|---|
| Fort Randall Motor Control Center | Award Notice | |
| Fort Randall Motor Control Center | Solicitation | |
| Fort Randall Motor Control Center | Pre-Solicitation | |
| Fort Randall Motor Control Centers and Panel Replacement | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity