Equipment for Generating Radiated Electrical Signals
Closed Pre-Solicitation Posted
- Solicitation number
- FMP-NNL-0038
- Agency
-
Department of Energy
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541715 Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology)
- Place of performance
- United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Energy is seeking equipment and solutions to address electronic noise interference in nuclear power plant instrumentation, specifically targeting the generation of radiated electrical signals to test coaxial cable susceptibility. The primary objective is to develop a portable device capable of generating electrical noise that can help identify vulnerable coaxial cables during production and maintenance processes. The desired device must fit through a 30" diameter opening, have an extendable antenna reaching up to 20 feet, and generate variable signal strengths and frequencies between 15 Hz to 60 kHz. The agency is specifically interested in solutions that can replicate current-inducing characteristics of production operations and provide faster alternatives to current cable mitigation methods. Key deadlines include a posted date of November 8, 2024, with proposals due by February 28, 2025, and the solicitation is categorized under NAICS 541715 for Research and Development in Physical, Engineering, and Life Sciences.
The pre-solicitation notice indicates no specific set-aside designations and does not reference current contractors or incumbent providers. The target cables are Mil Standard M17/233-00001 or M17/126-RG391 (98), contained within conduit with minimal connectors, and typically 50-150 feet in length. While no specific award value is mentioned, the technical requirements suggest a high-precision, specialized research and development contract focused on generating extremely low-amplitude electrical signals (10-10 to 10-11 amps) for testing nuclear instrumentation. The long-term goals include developing technologies that can make cables immune to radiated signals and create quick assessment methods for cable vulnerability. The solicitation is part of the Department of Energy's ongoing efforts to improve electronic noise mitigation in sensitive nuclear plant environments, with an emphasis on portable, adaptable testing technologies.
Notice text
3 versions
Update #3 · Latest ·
Equipment for Generating Radiated Electrical Signals
Suppliers are being sought for equipment and approaches to deal with electronic noise, as described herein.
Symptom: Electronic noise in a production environment, such as radiated electrical signals from nearby welding, grinding or equipment start-up, can effect coaxial cables supplying sensitive measurement equipment, causing erroneous signals. Although the spurious signals are on the order of 10-11 amps and might be considered insignificantly small for many applications, their appearance in sensitive nuclear plant instruments is problematic. This happens most commonly during production, maintenance or plant start/stop operations.
Cause & Context: Radiated electric and magnetic fields from production operations or from equipment transients (starts and stops) are to be expected. These fields can induce currents in cables connected to nearby sensitive measurement instruments. However, the operation causing offending electronic noise in a particular instrument is not always evident. In addition, the reason spurious signals are seen in one instrument but not others of similar design, construction and location is not always evident. Troubleshooting is time consuming and expensive and can impact critical path schedules.
Repair and mitigation steps are also time consuming and expensive, as the affected cables are often in hard-to-access locations. Technology to help eliminate the susceptibility of co-axial cables to radiated electrical noise, and/or to speed up the troubleshooting process, is being sought.
Desired End State: A near-term end state in which new tools are available to replicate the current-inducing characteristics of the operations cited above is the primary objective. This will allow testing to determine the vulnerability of a particular cable/instrument, without impacting critical path schedules.
A near-term end state in which faster alternatives to current mitigation methods are available is a second objective. Current methods usually involve shielding with metal sheets or foils, replacing cables or re-cleaning cable connections.
A long-term end state in which cables can be made immune to radiated signals is desirable. A long-term end state in which the vulnerability of cables to radiated signals can be quickly assessed using readily available or easy-to-obtain information is also desirable.
Candidates: The solution of most immediate interest would be a portable device capable of generating electrical noise to help identify susceptible coaxial cables early in the production or maintenance process. Such a device would have the following characteristics:
- Can fit through a 30” diameter opening
- Have an antenna (loop) capable of reaching in areas with minimal clearance, able to extend up to 20 feet
- Variable signal strength and frequency from 15 Hz to 60 kHz
- Target co-axial cable signal strength is typically between 10-10 to 10-11 amps or discrete counts (pulses).
- The target co-axial cable is Mil Standard M17/233-00001 or M17/126-RG391 (98) contained within conduit with a minimal number of connectors.
Update #2 ·
Equipment for Generating Radiated Electrical Signals
Suppliers are being sought for equipment and approaches to deal with electronic noise, as described herein.
Symptom: Electronic noise in a production environment, such as radiated electrical signals from nearby welding, grinding or equipment start-up, can effect coaxial cables supplying sensitive measurement equipment, causing erroneous signals. Although the spurious signals are on the order of 10-11 amps and might be considered insignificantly small for many applications, their appearance in sensitive nuclear plant instruments is problematic. This happens most commonly during production, maintenance or plant start/stop operations.
Cause & Context: Radiated electric and magnetic fields from production operations or from equipment transients (starts and stops) are to be expected. These fields can induce currents in cables connected to nearby sensitive measurement instruments. However, the operation causing offending electronic noise in a particular instrument is not always evident. In addition, the reason spurious signals are seen in one instrument but not others of similar design, construction and location is not always evident. Troubleshooting is time consuming and expensive and can impact critical path schedules.
Repair and mitigation steps are also time consuming and expensive, as the effected cables are often in hard-to-access locations. Technology to help eliminate the susceptibility of co-axial cables to radiated electrical noise, and/or to speed up the troubleshooting process, is being sought.
Desired End State: A near-term end state in which new tools are available to replicate the current-inducing characteristics of the operations cited above is the primary objective. This will allow testing to determine the vulnerability of a particular cable/instrument, without impacting critical path schedules.
A near-term end state in which faster alternatives to current mitigation methods are available is a second objective. Current methods usually involve shielding with metal sheets or foils, replacing cables or re-cleaning cable connections.
A long-term end state in which cables can be made immune to radiated signals is desirable. A long-term end state in which the vulnerability of cables to radiated signals can be quickly assessed using readily available or easy-to-obtain information is also desirable.
Candidates: The solution of most immediate interest would be a portable device capable of generating electrical noise to help identify susceptible coaxial cables early in the production or maintenance process. Such a device would have the following characteristics:
- Can fit through a 30” diameter opening
- Have an antenna (loop) capable of reaching in areas with minimal clearance, able to extend up to 20 feet
- Variable signal strength and frequency from 15 Hz to 60 kHz
- Target co-axial cable signal strength is typically between 10-10 to 10-11 amps or discrete counts (pulses).
- The target co-axial cable is Mil Standard M17/233-00001 or M17/126-RG391 (98) contained within conduit with a minimal number of connectors.
Update #1 ·
Equipment for Generating Radiated Electrical Signals
Suppliers are being sought for equipment and approaches to deal with electronic noise, as described herein.
Symptom: Electronic noise in a production environment, such as radiated electrical signals from nearby welding, grinding or equipment start-up, can effect coaxial cables supplying sensitive measurement equipment in a nuclear power plant, causing erroneous signals. Although the spurious signals are on the order of 10-11 amps and might be considered insignificantly small for many applications, their appearance in sensitive nuclear plant instruments is problematic. This happens most commonly during production, maintenance or plant start/stop operations.
Cause & Context: Radiated electric and magnetic fields from production operations or from equipment transients (starts and stops) are to be expected. These fields can induce currents in cables connected to nearby sensitive measurement instruments. However, the operation causing offending electronic noise in a particular instrument is not always evident. In addition, the reason spurious signals are seen in one instrument but not others of similar design, construction and location is not always evident. Troubleshooting is time consuming and expensive and can impact critical path schedules.
Repair and mitigation steps are also time consuming and expensive, as the effected cables are often in hard-to-access locations. Technology to help eliminate the susceptibility of co-axial cables to radiated electrical noise, and/or to speed up the troubleshooting process, is being sought.
Desired End State: A near-term end state in which new tools are available to replicate the current-inducing characteristics of the operations cited above is the primary objective. This will allow testing to determine the vulnerability of a particular cable/instrument, without impacting critical path schedules.
A near-term end state in which faster alternatives to current mitigation methods are available is a second objective. Current methods usually involve shielding with metal sheets or foils, replacing cables or re-cleaning cable connections.
A long-term end state in which cables can be made immune to radiated signals is desirable. A long-term end state in which the vulnerability of cables to radiated signals can be quickly assessed using readily available or easy-to-obtain information is also desirable.
Candidates: The solution of most immediate interest would be a portable device capable of generating electrical noise to help identify susceptible coaxial cables early in the production or maintenance process. Such a device would have the following characteristics:
- Can fit through a 30” diameter opening
- Have an antenna (loop) capable of reaching in areas with minimal clearance, able to extend up to 20 feet
- Variable signal strength and frequency from 15 Hz to 60 kHz
- Target co-axial cable signal strength is typically between 10-10 to 10-11 amps or discrete counts (pulses).
- The target co-axial cable is Mil Standard M17/233-00001 or M17/126-RG391 (98) contained within conduit with a minimal number of connectors.