Cougar spillway gate two repair
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- W9127N-22-R-0027
- Agency
-
ENDIST Portland
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 237990 Other Heavy and Civil Engineering Construction
- PSC
- Z2KA Repair Or Alteration Of Dams
- Place of performance
- Blue River, Oregon 97413, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice is seeking capability statements from interested parties for the Cougar Spillway Gate Two Repair project for the U.S. Army Corps of Engineers Portland District. The project scope includes fully rehabilitating one spillway gate to current design standards, replacing hoist and electrical control equipment, installing secondary containment and fall protection, and other repairs. Respondents must demonstrate experience with relevant construction projects and qualifications including plant and fabricator certifications. Capability statements are due by April 7, 2022.
There is no set-aside designation for this opportunity. The NAICS code is 237990 for other heavy and civil engineering construction, with a size standard of $39.5M. The project value is estimated between $1M-$5M. Specific requirements include certifications for precast concrete production, steel fabrication, and experience with metal building design standards. No incumbent or current contractor is identified.
Notice text
COUGAR SPILLWAY GATE TWO REPAIR
U.S. ARMY CORPS OF ENGINEERS, PORTLAND DISTRICT
ISSUED: 03/25/2022
RESPONSES DUE: 04/07/2022 at 2:00 pm
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary, and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
The proposed NAICS code for this procurement is 237990 - Other Heavy and Civil Engineering Construction.
The size standard: $39.5M
Federal Service Code: Z2KA, Repair or Alteration of Dams
The purpose of this project is to fully rehabilitate one gate at Cougar Dam to current design standards and improve the reliability of the system, repair/replace hoist equipment, install staff gauges, replace electrical gate control equipment, replace distribution switchgear, re-conductoring from the switchgear to the spillway gates, decrease the environmental hazards by installing secondary containment around all oil and grease sources greater than 50 gallons, and decrease fall hazards by replacing damaged/missing hand rails and installing fall protection equipment.
The Cougar Spillway Gate Two Repair will include to the following items:
Strengthening hydraulic steel structures by adding stiffeners on selected ribs , replacing strut arm assemblies, trunnion hub and base, girder and diaphragm bracing, lifting anchor assembly, guide shoes, and wearing plates of the Tainter gate
- Add machinery platforms and cover structures. Design thru-fence access doors to allow maintenance greasing of line shaft couplings from roadway.
• Replace trunnion bearings, wire ropes and their gate connection assemblies, thrust washers, seals and components as necessary
• Replace hoist equipment, install load limiting devices and brake system
• Repair/replace all damaged or missing hand rails, guard rails and fall protection equipment to bring up to current EM385-1-1 standards
• Install new Gate 2 line shaft assembly
• Replace line shaft bearing inserts on Gate 1
• Install secondary oil containment systems around all oil or grease containing equipment that is near water or can drain into the dam sump. (Including trunnion bearings, intermediate shaft bearings, parallel gearboxes, worm drives, etc.)
• Replace/upgrade local indication at the gates and install staff gauges on all gates as backup to the local indication per EM 1110-2-6071
• Replace limit switches to improve reliability
• Replace electrical gate control and 120V/480V receptacle stations equipment and install with Government Furnished Equipment (GFE)
• Install new conduit system for control and power cables/conductors to GFE electrical gate controls and 120V/480V receptacle stations equipment
• Replace existing single overhead 480V feeder with two new buried concrete in-cased 480V feeders from Motor Control Center from Intake Tower to Spillway Distribution Panel through existing manholes and new handholes
• Replace and add new independent 480V feeder from Intake Tower to Dam Safety’s Seismograph equipment structures
• Reestablish connection to existing Dam Safety’s piezo meter equipment control and power system with new conduit and cables/conductors in new underground trench system and handholes
• Install new fiber optic patch panel system at Spillway and auxiliary equipment in existing panel in Intake Tower
• Install new fiber optic cable from Intake Tower to Spillway
The anticipated magnitude for this project will be between $1,000,000 and $5,000,000.
NO AWARD WILL MADE FROM THIS INITIAL NOTICE. THIS IS NOT AN INVITATION FOR BIDS OR REQUEST FOR PROPOSALS.
Submission Instructions: Please send responses with the subject heading Cougar Spillway Gate Two Repair to Cory Pfenning, email address: cory.r.pfenning@usace.army.mil and Kristina Morrow, email address: kristins.k.morow@usace.army.mil
CAPABILITY STATEMENT TO SHOW INTEREST AND INTENT:
Respondents interested in performing the proposed project as a prime contractor should submit a capability statement for consideration that include the following: (In A through F).
A. Offerors' name, address, points of contact with telephone numbers and e-mail addresses.
B. DUNS number and CAGE code.
C. Firm's small business category and Business Size: Small Business (SB), Small Disadvantaged (SDB), including 8(a) firms, Historically Underutilized Business Zones (HUBZone), Women-Owned Small Business (WOSB), including Economically Disadvantaged Women-Owned Small Business (EDWOSB), and Service-Disabled Veteran-Owned Small business (SDVOSB).
D. A Statement of Capability (SOC) stating your skills, experience, and knowledge required to perform the specified type of work as described above. This SOC should be a brief description of your company's capabilities. The potential bidders should provide the magnitude and brief references of relevant work they have performed. Include a statement detailing any special qualifications and certifications, applicable to the scope of this project, held by your firm, in-house personnel, or business partners including the following;
• The precast concrete producer must be certified by the National Precast Concrete Association's and/or the American Concrete Pipe Association's Plant Certification Program prior to and during production of the products for this project.
• The fabricating plant and fabricator must be certified under the AISC (American Institute of Steel Construction) Quality Management System, Advanced Bridges (ABR) or Intermediate Bridges (IBR) category with Fracture Critical endorsement (FC).
• Metal building system manufacturer must be a member of the Metal Building Manufacturers Association (MBMA) Building System and certified under AC472.
• Licensed engineer in Oregon knowledgeable in building design analysis, protocols and procedures for the "Metal Building Systems Manual" (MBMA MBSM); ASCE 7, and ASTM E1592.
E. Indicate whether your company will perform the work directly or intends to subcontract the work. If subcontracting, identify the percentage of work to be subcontracted. Identify the percentage of work your firm may be capable of directly performing.
F. Any other information that would assist in determining your company's capability in performing the described construction work.
Responses to the Sources Sought will not be returned. Responders are solely responsible for all expenses associated with responding to this Sources Sought. USACE Portland District will not pay for information received in response to this Sources Sought.
Do not submit pricing information in response to this Sources Sought.
All responses must be submitted in either Microsoft Word or Adobe Portable Document Format by no later than 2:00 pm Pacific Daylight Time on 07 April 2022. Do not include proprietary information in your response.
The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate.
Point of Contact for small business questions or assistance is the Portland District Deputy for Small Business, Carol McIntyre at 503-808-4602 or Carol.A.Mcintyre@usace.army.mil.
Notice history
| Notice | Type | Posted |
|---|---|---|
| Cougar spillway gate two rehabilitation | Award Notice | |
| Cougar spillway gate two rehabilitation | Solicitation | |
| Cougar spillway gate two rehabilitation | Special Notice | |
| Cougar spillway gate two repair | Pre-Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| W9127N27BA005 Foster Spillway Gate Nut Replacements and Re-Tensioning | ENDIST Portland | Total Small Business | |
| Camp wooten/starbuck levee rehab | ENDIST Walla Walla | No set-aside | |
| John day DAM navigation lock tainter valve (TV) repairs TV3 and TV4 | ENDIST Portland | No set-aside | |
| USCG Station at Cape Disappointment | ENDIST Portland | No set-aside | |
| John day DAM unit 10 packing box replacement | ENDIST Portland | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity