Animal cages with HEPA filtering system

Award Notice Posted

Solicitation number
W81XWH15T0314
Agency
Awarded
to Tecniplast Usa, Inc.
Set-aside
Total Small Business

Opportunity facts

Contract number
W81XWH16P0093 Federal contract award
NAICS code
339999 All Other Miscellaneous Manufacturing
PSC
Not on record
Place of performance
US Army Medical Research Acquisition Activity - Jeff Sprecher 820 Chandler Street Frederick MD 21702 US
More information

Notice details come from SAM.gov. Updated .

Notice text

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI will be treated as business confidential information. Nonetheless, submitters should properly mark their responses if the information is confidential. Response to the RFI will not be returned. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expense associated with responding to this RFI.

RFI Response and due date: 4 August 2015, by 12:00 P.M. EST.

Instructions to Responders:

Responses from all capable and qualified sources are encourgaged to respond to this request.

White papers should adhere to the following formatting and outline instructions:

1. All submissions shall be made electronically and be in one of the following formats: Microsoft Word or Adobe PDF.

2. Cover Page (1page)
* Title
* Organization
* Responders technical and administrative points of contact (names, addresses, phone, fax number and email addresses)
* Topic area(s) addressed


3. Completed Attachment 1, and Attachment 2. Please note that the response shall provide sufficient technical data to determine how you fully meet the requriements as specified in Attachment 2.

Please note that responses are due no later than 4 August 2015, 12:00 PM EST. The preferred method of submission is via email. The point of contact for this action is Jeffrey Sprecher, Contract Specialist, Email: jeffrey.b.sprecher.civ@mail.mil. Only electronic responses are requested. No evaluation letters and/or results will be issued to the respondents. At this time no solicitation exists; therefore, please do not request a copy of the solicitation. NO PHONE CALLS PLEASE. It is the responsibility of any potential offeror to monitor this site for the release of any solicitation or synopsis.

Background/Overview: The Walter Reed Army Institute of Research (WRAIR) in Silver Spring, MD is looking for replacement caging for cages that are broken or disfigured through normal wear and use.The required supplies are HEPA filtered individually ventilated caging used to house rodents on a Tecniplast rack system. The system includes; mouse cages, rat cages, and auto-watering lixits. The Veterinary Services Program currently has 25 similar rack systems and several rodent cages in the facility from Tecniplast.
(End)


Attachment 1.

Question
Answer
RFI Number



Company Name

Company Address

Point of Contact

Phone Number

E-mail Address

Tax Identification Number (TIN)

DUNS

Company Web Page

Company Location(s)



Company is / is not a Small Business

Company is / is not SAM Registered

Company is / is not ORCA Registered

Other Classifications (e.g. 8(a), HubZone, Woman-Owned, Veteran-Owned, Service-Disabled Veteran-Owned)

Product is/is not manufactured by a small business



The proposed product is/is not available on Army Computer Hardware Enterprise Software Solutions (CHESS), at www.chess.army.mil

The proposed product is/is not available on General Service Administration (GSA), at www.gsaadvantage.gov

The proposed product is/is not available on NASA Solutions Enterprise-Wide Procurement (SEWP), at www.sewp.nasa.gov.

Proposed product is/is not TAA Compliant

Place of manufacture

Description of Products or Services that are Already Delivered to Customers Today, and Could be Comparable to what is Requested in this RFI

List of Customers using Comparable Products or Services (including contact information)

List of Customers using your Products or Services today, Although they are not Comparable with what is Requested in this RFI (including contact information)

Numbers of Years Product or Services on the Market and in use by Customers

Conditions that's Listed in the RFI and can't be met








Other Solution Information Pertinent to this RFI for Government Consideration







(End)


Attachment 2.

The requirements listed in the table below shall be accommodated by the responder offering a complete Cage system. Please indicate Y (yes) or N (No) if your system meets each requirement in the requirements list below, and use the comments column to further justify how your product meets the requirement.




REQUIREMENTS/ SPECIFICATIONS

MEETS REQUIREMENT?
(Y/N)
COMMENTS
SOFTWARE CAPABILITIES:


DATABASE:


1
Four (4) 35 cage, single-sided, Individually Ventilated Cage (IVC) rat rack with auto watering and cage setups



2
Three (3) 70 cage, single-sided, IVC mouse rack with auto watering and cage setups



3
Cage setups will consist of: high-temperature polysulfone cage body, stainless steel wire lid w/ food hopper, high-temperature polysulfone cage top w/bottle depression and microbiological filter, and universal card holder.



4
Four air handling units with HEPA filtration specifically designed to operate with mouse and rat rack.



Rat Rack and Cages


5
Rat IVC rack must hold 35 cages on a single-sided rack



6
Rat IVC rack must have automatic watering



7
Rat IVC rack must be compatible with the Tecniplast cage: GR900SUED - Polysulfone Cage Bodies with Autowatering Grommets and BOX110SF blower unit.



8
210 Additional High-Temp cage setups



Mouse Rack and Cages


9
Mouse IVC rack must hold 70 cages on a single-sided rack



10
Mouse IVC rack must have automatic watering



11
Mouse IVC rack must be compatible with the Tecniplast cage: 1285L00SUEDV - Polysulfone Cage Bodies with Autowatering Grommets and BOX110SF blower unit.


12
315 Additional High-Temp cage setups



AIR HANDLING UNITS (AHU)


13
AHU must be compatible with Tecniplast rodent racks and caging.



14
AHU must have a digital touch panel for visualization of air change rates and positive or negative air flow.



15
AHU must have HEPA filters for supply and exhaust