Working Drawings_236007 RBC Gym Bathrooms_2023-08-04-COMPILED SET.pdf
PDF 21 MB Posted
- Attached to
- Statesman Bathroom Renovation Project
- Solicitation number
- 64159
- Issued by
- Prince George County, Virginia
About this file
The document titled "Working Drawings_236007 RBC Gym Bathrooms_2023-08-04-COMPILED SET.pdf" appears to be a set of architectural drawings and specifications related to the Statesman Bathroom Renovation Project in Prince George County, Virginia. This project involves the renovation of the restrooms, staff breakroom, and adjacent corridors within Statesman Hall. The drawings provide detailed technical information about the construction, materials, and design of the planned renovations.
The document does not contain any information about response dates, due dates, site visits, bidder's meetings, award dates, pricing terms, set asides, incumbents, funding requirements, or other salient contract details. It is focused solely on the technical specifications of the planned construction work.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 4.9.24.pdf | ||
| Bid Package Statesman Bathroom Renovation.pdf | ||
| SKM_C250i24032604130.pdf | ||
| Addendum 3.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
ALL WORK AND MATERIALS SHALL COMPLY WITH ALL LOCAL AND GOVERNING CODES.
ALL WORK AND MATERIALS SHALL BE PROVIDED AND INSTALLED BY QUALIFIED PERSONNEL IN A WORKMANLIKE MANNER.
ALL PRODUCTS SHALL BE NEW, BEST OF THEIR KIND, AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
CONTRACTOR SHALL VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BEGINNING CONSTRUCTION OR ORDERING MATERIALS. SHOULD THE CONTRACTOR FIND ANY DISCREPANCIES, OMISSIONS, AMBIGUITIES, OR CONFLICTS WITHIN THE CONSTRUCTION DOCUMENTS, OR SHOULD THEY BE IN DOUBT AS TO THEIR MEANING OR INTENTION, THEY SHOULD NOTIFY THE ARCHITECT FOR CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK. DURING CONSTRUCTION, THE CONTRACTOR MAY EXPOSE CONDITIONS THAT ARE UNSTABLE OR UNSAFE. IF THE CONTRACTOR FINDS SUCH CONDITIONS,THEY SHALL TAKE EMERGENCY ACTION TO STABILIZE THE CONDITIONS AND NOTIFY THE OWNER AND
ARCHITECT IMMEDIATELY.
CONTRACTOR SHALL COORDINATE THE WORK OF ALL SUBCONTRACTORS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO BID ALL PARTS OF THE CONSTRUCTION DOCUMENTS TO ALL SUBCONTRACTORS. THE ENTIRE SET OF CONSTRUCTION DOCUMENTS IS COHESIVE AND HOLISTIC FOR ALL TRADES. NOTES INDICATED ON ONE SHEET APPLY
TO ALL SHEETS OF THE DRAWINGS FOR ALL TRADES.
CONTRACTOR SHALL COORDINATE ALL REQUIRED UTILITY WORK.
CONTRACTOR SHALL MAINTAIN A CLEAN AND SECURE WORK SITE AT ALL TIMES.
CONTRACTOR SHALL PROVIDE ALL REQUIRED EROSION CONTROL DEVICES, CONSTRUCTION BARRICADES, AND PROTECTIVE DEVICES DURING CONSTRUCTION.
CONTRACTOR SHALL MAINTAIN FIRE EXTINGUISHING EQUIPMENT AT THE WORK AREA AT ALL TIMES.
DIMENSIONS ARE TO FINISH SURFACE UNLESS OTHERWISE NOTED
ALL DIMENSIONS SHALL BE CHECKED AND VERIFIED PRIOR TO PROCEEDING WITH THE WORK OR ORDERING MATERIALS. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR
CONFLICTS.
ALL FRAMING WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED TO PREVENT ROT AND DECAY.
PROVIDE SEALANT AND BACKER ROD AT ALL WOOD, METAL, AND CONCRETE JOINTS. CAULK BETWEEN MASONRY AND OTHER MATERIALS.
ISOLATE DISSIMILAR METALS TO PREVENT GALVANIC ACTION OR CORROSION.
ALL PIPES, DUCTS, VENTS, WIRES, ETC. ARE TO BE CONCEALED UNLESS OTHERWISE NOTED.
PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT NECESSARY TO COMPLETE THE WORK.
DO NOT USE OPEN FLAMES, HEATING EQUIPMENT, CUTTING EQUIPMENT OR OTHER TOOLS IN A WAY THAT WOULD IGNITE COMBUSTIBLE CONSTRUCTION OR MATERIALS.
MAINTAIN ALL STATUTORY REQUIRED INSURANCE FOR THE PROJECT. SUBMIT A CERTIFICATE OF INSURANCE TO THE OWNER FOR REVIEW BY THE OWNER'S INSURANCE AGENT.
UPDATE THE ARCHITECT AND THE OWNER ON THE PROGRESS OF THE WORK ON A REGULAR BASIS. PROVIDE A SCHEDULE FOR THE PROJECT. PROVIDE ACCESS AND ALLOW THE
ARCHITECT TO REVIEW THE CONSTRUCTION THROUGHOUT THE PROJECT.
PROVIDE DAMP PROOFING ON ALL WALLS BELOW GRADE, AND ALL MASONRY WALL SURFACES INSIDE WALL CAVITIES.
PROVIDE PREFABRICATED END DAMS, CORNERS, AND TRANSITIONS AT ALL FLASHING AREAS.
PROVIDE CONTROL JOINTS AND EXPANSION JOINTS AS RECOMMENDED BY MANUFACTURERS AND AS REQUIRED BY INDUSTRY STANDARDS. MASONRY EXPANSION JOINTS SHALL BE LOCATED NEAR BUILDING CORNERS AND MAJOR WINDOWS. JOINTS SHALL NOT EXCEED 20'-0" O.C. UNLESS APPROVED BY ARCHITECT. REVIEW EXPANSION JOINT LOCATIONS
WITH ARCHITECT PRIOR TO INSTALLATION.
IN CASES OF CONFLICTS BETWEEN DRAWINGS AND/ OR SPECIFICATIONS, THE CONTRACTOR IS TO NOTIFY THE ARCHITECT FOR CLARIFICATIONS BEFORE PROCEEDING WITH THE WORK. FOR BID AND PRICING PURPOSES, THE MORE EXPENSIVE OR RESTRICTIVE OPTION SHOULD BE INCLUDED IN THE PROJECT.
DO NOT SCALE DRAWINGS. CONTRACTOR TO RELY ON WRITTEN DIMENSIONS. ALL DIMENSIONS SHOULD BE VERIFIED. NOTIFY ARCHITECT FOR CLARIFICATION.
THE CONTRACTOR SHALL COORDINATE AND VERIFY THE INSTALLATION OF BUILDING SYSTEMS AND COMPONENTS PRIOR TO INSTALLATION. PREPARE COORDINATION DRAWINGS AND SHOP DRAWINGS TO SHOW INTEGRATION OF BUILDING SYSTEMS. ASSEMBLE AND INSTALL PIPES, DUCTS, ELECTRICAL AND OTHER BUILDING CONSTRUCTION TO AVOID CONFLICTS WITH THE DESIGN INTENT. SHIFT BUILDING SYSTEMS AS REQUIRED TO ACHIEVE THE FINISHED DIMENSIONS OF WALLS, CEILINGS AND OTHER ARCHITECTURAL FEATURES.
MAINTAIN STRUCTURAL INTEGRITY AT ALL TIMES.
THESE DRAWINGS ARE BASED ON HISTORICAL DRAWINGS OF THE EXISTING BUILDING AND LIMITED FIELD INVESTIGATION. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO PERFORMING THE WORK. CONTRACTOR MAY REQUEST ACCESS TO PREVIOUS CONSTRUCTION DOCUMENTS TO THE OWNER FOR ADDITIONAL INFORMATION IF
REQUESTED.NORTHNORTH
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
VICINITY MAP LOCATION MAP
A0.01
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
COVER
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
RICHARD BLAND COLLEGE GYM BATHROOM
WORKING DRAWINGS
PROJECT # 236007
7/21/23
OWNER ARCHITECT
ENTEROS DESIGN
7 NORTH 25TH STREET,
SUITE 100
RICHMOND, VA 23223
804.861.1200
WWW.ENTEROSDESIGN.COM
RICHARD BALND COLLEGE
11301 JOHNSON ROAD
SOUTH PRINCE GEORGE, VA 23805
MEP CONSULTANT
INVERSITY CONSULTING
250 WYLDEROSE CMNS SUITE 102,
MIDLOTHIAN, VA 23113
804.977.0403
INVERSITYCONSULTING.COM
REVISIONS
# DATE DESCRIPTION
A101
A101
1 VIEW NAME
1/8" = 1'-0"A101
A101
A202
Name Elevation
ROOM NAME
ROOM NAME
150 SF
A3.3
BUILDING OR WALL
SECTION TAG
(WHERE CUT)
WALL SECTION NUMBRER
SHEET WHERE SECTION IS INDICATED
DRAWING NUMBER
DRAWING NAME (PLAN)
SHEET WHERE PLAN IS DRAWN
DETAIL OR ENLARGED PLAN
WHERE CUT
CENTERLINE
DOOR TAG
EXTERIOR ELEVATION
WHERE CUT
INTERIOR ELEVATION
WHERE CUT
STRUCTURAL GRID LINE
WITH DESIGNATIONS
##KEYNOTE
DRAWING SCALE
PLAN VIEW TITLE
ENLARGED PLAN, ELEVATION,
BUILDING SECTION, WALL
SECTION, DETAIL VIEW TITLE
A101
DETAIL OR ENLARGED PLAN NUMBER
SHEET NUMBER WHERE DETAIL OR ENLARGED PLAN IS
DRAWN
ELEVATION NUMBER
SHEET WHERE ELEVATION IS DRAWN
ELEVATION NUMBER
MULTIPLE ELEVATIONS
SHEET WHERE ELEVATION IS DRAWN
PARTITION TAG
WORKPOINT
ROOM NAME WITH AREA
ROOM NAME
REVISION TAG
ELEVATION LEVEL
SPOT/CEILING ELEVATION
SYMBOLS (SEE ALSO SHEET A0.10 FOR LIFE SAFETY & CODE PLAN SYMBOLS)
DIMENSION XX' - XX"
@ AT
A-PT ACCENT PAINT
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABS AIR BARRIER SYSTEM
ABV ABOVE
ACP ACOUSTICAL CEILING PANEL
ACT ACOUSTICAL CEILING TILE
ACW ALUMINUM CLAD WINDOW
ACWP ALUMINUM COMPOSITE WALL PANEL
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
AL ALUMINUM
AP ACCESS PANEL
APC ARCHITECTURAL PRECAST CONCRETE
AS ALUMINIUM STOREFRONT
ATTN ATTENUATION
AUTO AUTOMATIC
AVG AVERAGE
AW ALUMINIUM WINDOW
AWC ACOUSTICAL WALL COVERING
AWP ACOUSTICAL WALL PANEL
BEJ BUILDING EXPANSION JOINT
BD BOARD
BF BARRIER FREE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BENCH MARK
BOT BOTTOM
BOS BOTTOM OF STRUCTURE
BOW BOTTOM OF WALL
BRG BEARING
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOF
C CARPET
CAB CABINET
CB CHALKBOARD
CCTV CLOSED CIRCUIT TELEVISION
CFSF COLD FORMED STEEL FRAMING
CFSF-S COLD FORMED STEEL FRAMING, STRUCTURAL
CG CORNER GUARD
CIPC CAST IN PLACE CONCRETE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CM CENTIMETER
CMBD CEMENT BOARD
CMU CONCRETE MASONRY UNIT
CMU-A CONCRETE MASONRY UNIT-ACOUSTICAL
CMU-GF CONCRETE MASONRY UNIT - GROUND FACE
CMU-GLZ CONCRETE MASONRY UNIT - GLAZED
CMU-SPLF CONCRETE MASONRY UNIT - SPLIT FACE
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRIDOR
CPT CARPET TILE
CR CLASSROOM
CRS COURSE
CSMU CAST STONE MASONRY UNIT
CT CERAMIC TILE
CTSK COUNTERSINK
CUFT CUBIC FOOT
CUYD CUBIC YARD
CW CURTAIN WALL
CWFD CEMENTITIOUS WOOD FIBER DECK
D DEPTH/DEEP
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DG DOOR GRILLE
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIV DIVISION
DL DOOR LOUVER
DN DOWN
DP DAMPPROOFING
DR DISPLAY RAIL
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
DWR DRAWER
EA EACH
EF EXHAUST FAN
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION & FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAS ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EPS EXPANDED POLYSTYRENE
EPX EPOXY
EPX PT EPOXY PAINT
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EX EXISTING
EXH EXHAUST
EXP EXPANSION
EXPC EXPOSED CONSTRUCTION
EXPC PT EXPOSED CONSTRUCTION-PAINTED
EXT EXTERIOR
FAAF FLUID APPLIED ATHLETIC FLOORING
FB FACE BRICK
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISHED FLOOR
FFE FINISHED FLOOR ELEVATION
FGL FIBERGLASS
FGRC FIBERGLASS REINFORCED CONCRETE
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHVC FIRE HOSE VALVE CABINET
FIN FINISHED
FLR FLOOR
FLRG FLOORING
FND FOUNDATION
FO FACE OF
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOW FACE OF WALL
FR FIRE RATED
FRA FIRE RATED ASSEMBLY
FRM FRAME
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FT FOOT
FTG FOOTING
FURN FURNITURE
FVC FIRE VALVE CABINET
FWC FABRIC WALL COVERING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GPDW GYPSUM DRYWALL
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GL-BLK GLASS BLOCK
GPL GYPSUM PLASTER
GPM GALLONS PER MINUTE
GRAN GRANITE
GSF GROSS SQAURE FOOT
GSU GLAZED STRUCTURAL UNIT
GT GLASS TILE
GWT GLAZED WALL TILE
GYP GYPSUM
HB HOSE BIBB
HBD HARDBOARD
HDNR HARDENER
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSEPOWER
HPFP HIGH PERFORMANCE FLOOR PAINT
HR HOUR
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING, AIR CONDITIONING
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE
INFO INFORMATION
INST INSTALLATION
INSUL INSULATION
INT INTERIOR
IRWC IMPACT RESISTANT WALL COVERING
IWB INTERACTIVE WHITE BOARD
JAN JANITOR
JC JANITOR CLOSET
JCT JUNCTION
JT JOINT
KO KNOCKOUT
L LENGTH/LONG
LAB LABORATORY
LAHJ LOCAL AUTHORITY HAVING JURISDICTION
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LGMF LIGHT GAUGE METAL FRAMING
LH LEFT HAND
LIN LINOLEUM
LKR LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMC LINEAR METAL CEILING
LPS LAMINATE PANEL SYSTEM
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M METER
MACH MACHINE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKERBOARD
MBL MARBLE
MCP METAL CEILING PANEL
MECH MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MFR MANUFACTURER
MIF MULTICOLOR INTERIOR FINISHING
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING
MM MILLIMETER
MO MASONRY OPENING
MPS MANUAL PROJECTION SCREEN
MR MAP RAIL
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTL METAL
MTLB METAL BASE
MWP MEMBRANE WATERPROOFING
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO. NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP HD OPPOSITE HAND
OVHD OVERHEAD
PC PRECAST
PCP PORTLAND CEMENT PLASTER
PERF PERFORATED
PERM PERIMETER
PIP POURED IN PLACE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLASTIC LAMINATE WOOD
PLYWD PLYWOOD
PNT PAINT
PNTD PAINTED
POLY POLYETHYLENE
POLYISO POLYISOCYANURATE
PS PROJECTION SCREEN
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PREP PREPARE/PREPARATION
PS PROJECTOR SCREEN
PSB PENCIL SHARPENER BLOCK
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE/PRESERVATIVE TREATED
PTL PORCELAIN TILE
PTLB PORCELAIN TILE BASE
PTN PARTITION
PTS PNEUMATIC TUBE SYSTEM
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PVWC PERFORATED VINYL WALL COVERING
QT QUARRY TILE
QTY QUANTITY
R RISER
R/W RIGHT OF WAY
RA RETURN AIR
RAD RADIUS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RECP RECEPTACLE
REFG REFRIGERATOR
REINF REINFORCING
REM RECESSED ENTRY MAT
RENO RENOVATION
RES RESINOUS FLOORING
RFG ROOFING
RFT RUBBER FLOOR TILE
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RSF RESILIENT SPORTS FLOORING
RSF-RFT RESILIENT SPORTS FLOORING - RUBBER FLOOR TILE
RSR RESILIENT STAIR RISER
RST RESILIENT STAIR TREAD
RT RIGHT
RTU ROOFTOP UNIT
SAB SOUND ATTENUATION BLANKET
SC-PLK SECURITY CEILING PLANK
SC-PNL SECURITY CEILING PANEL
SCH SCHEDULE
SF SQUARE FOOT
SFRM SPRAYED FIRE RESISTANT MATERIAL
SGB SECURITY GYPSUM BOARD
SHM SECURITY HOLLOW METAL
SHTG SHEATHING
SIM SIMILAR
SPEC SPECIFICATION
SPF SPRAYED POLYURETHANE FOAM
SPFCC SPRAYED POLYURETHANE FOAM CLOSED CELL
SPR SPRINKLER
SQ SQUARE
SRD SECONDARY ROOF DRAIN
STND STAINED
SS STAINLESS STEEL
SSURF SOLID SURFACE
ST STREET
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
SV SHEET VINYL
SWM SECURITY WOVEN MESH
SY SQUARE YARD
SYM SYMMETRICAL
T TREAD
T&G TONGUE & GROOVE
T.O. TOP OF
TB TACKBOARD
TEL TELEPHONE
THHD THRESHOLD
THK THICKNESS
TOS TOP OF STRUCTURE
TOW TOP OF WALL
TRT TREATED
TS TACK STRIP
TV TELEVISION
TYP TYPICAL
UC UNDERCUT
UG UNDERGROUND
UH UNIT HEATER
UON UNLESS OTHERWIDE NOTED (INDICATED)
VAT VINYL ASBESTOS TILE
VCT VINYL COMPOSITION TILE
VDB VISUAL DISPLAY BOARD
VERT VERTICAL
VEST VESTIBULE
VFCT VINYL FREE COMPOSITION TILE
VR VAPOR RETARDER
VRB VINYL/RUBBER BASE
VT VINYL TILE
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WIDE
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WATER CLOSET
WCP WOOD CEILING PANEL
WD WOOD
WD-PNL WOOD PANELING
WDW WINDOW
WG WALL GUARD
WH WATER HEATER
WP WATERPROOFING
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSF WOOD SPORTS FLOORING
WT WALL TILE
WGT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
YD YARD
ARCHITECTURAL ABBREVIATIONS
SCALE: 1/4" = 1'-0"
0' 2' 4' 8' 12'
ARCHITECTURAL GRAPHIC SCALES
SCALE: 1/16" = 1'-0"
0' 8' 16' 32' 48'
SCALE: 1-1/2" = 1'-0"
0' 6" 1' 2'3"
SCALE: 3" = 1'-0"
0' 3" 6" 1'1"
SCALE: 1/2" = 1'-0"
0' 1' 2' 4' 6'
SCALE: 6" = 1'-0"
0' 2" 3" 6"1"
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A0.02
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
DRAWING INDEX &
PROJECT
INFORMATION
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
DRAWING INDEX - COVER SHEET
Sheet Number Sheet Name
PROJECT INFORMATION
A0.01 COVER
A0.02 DRAWING INDEX & PROJECT INFORMATION
ARCHITECTURAL
A0.10 LIFE SAFETY & CODE PLAN
A0.30 EXISTING PHOTOS
A2.01 FLOOR PLANS
A8.01 BATHROOM PLANS, ELEVATIONS & DETAILS
A8.02 INTERIOR ELEVATIONS & DETAILS
A8.03 MILLWORK ELNARGED PLANS, SECTIONS & DETAILS
A9.03 FINISH SCHEDULE & DETAILS
PLUMBING
P0.01 PLUMBING - LEGEND & SCHEDULES
P1.01 PLUMBING - PARTIAL PLANS, DETAILS, & SPECIFICATIONS
ELECTRICAL
E0.01 ELECTRICAL - LEGEND, SCHEDULES & DETAILS
E1.01 ELECTRICAL - PARTIAL FIRST FLOOR PLANS
SPECIFICATION NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
6.
1.
2.
3.
4.
5.
A.
B.
6.
A.
B.
7.
8.
9.
10.
11.
12.
1.
2.
3.
4.
5.
CONCRETE
CONCRETE SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITIUTE (ACI) 301, AND 318.
CONCRETE SHALL BE NORMAL WEIGHT AND HAVE MINIMUM COMPRESSIVE STRENGTH OF 3,500 PSI AT 28 DAYS UNLESS OTHERWISE NOTED ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED AND VIBRATED DURING PLACEMENT AND WORKED AROUND EMBEDDED ITEMS AND INTO
CORNERS OF FORMS
PLACE CONCRETE ON SOLID UNDISTURBED SOIL OR ENGINEERED FILL WITH MINIMUM BEARING CAPACITY OF 2,000 PSF COORDINATE PLACEMENT OF ALL EMBEDDED ITEMS INCLUDING REINFORCING ANCHOR BOLTS DOWELS AND SPECIALTY ITEMS ACCURATELY LACE
SECURE ITEMS PRIOR TO PACEMENT OF CONCRETE
ALL CONCRETE SHALL BE PLACED WITH A SLUMP OF BETWEEN 3-5 INCHES
FINISH CONCRETE TO BE FLUSH AND SMOOTH WITH ADJACENT SURFACE.
PATCH AND REPAIR VAPOR BARRIER BELOW DEMOLISHD CONCRETE. PROVIDE NEW 15 MIL STEGO WRAP VAPOR BARRIER BELOW NEW CONCRETE.
CUT AND PATCH EXISTING CONCRETE AS REQUIRED FOR THE INSTALLATION OF PLUMBING ANDR EQUIPMENT.
CONCRETE MASONRY
CONCRETE MASORNRY MATERIALS AND CONSTRUCTION SHALL CONFIRM TO THE AMERICAN CONCRETE INSTITUTE (ACI) 530.
ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW UNITS ASTM C90 MADE WITH LIGHTWEIGHT AGGREGATE WITH MINIMUM NET STRENGTH OF 1,900
PSI AT 28 DAYS.
COMPRESSIVE STRENGTH OF MASONRY SHALL BE DETERMIND BY THE UNIT STRENGTH METHOD AS SET FORTH IN ACI 530.1. THE NET AREA
COMPRESSIVE STRENGTH OF MASONRY F'M SHALL BE 1,500 PSI AT 28 DAYS.
MORTAR SHALL BE TYPE M OR S AND SHALL COMPLY WITH ASTM C270
GROUT SHALL COMPLY WITH ASTM C 476 PROPERTIES SPECIFICATION AND SHALL BE PROPORTIONED TO OBTAIN A 28 DAY COPMPRESSIVE STRENGTH
OF 2,000 PSI.
REINFORING STEEL SHALL COMPLY WITH ASTM A 615, GRADE 60. SHOP FABRICATED REINFORCING BARS WHICH ARE SHOWN TO BE BENT OR
HOOKED.
ALL JOINTS ARE TO BE FILLED SOLID WITH MORTAR.
ALL MASONRY CONTAINING REINFORCING DOWELS ANCHOR BOLTS EMBEDS OR OTHER STRUCTUREAL ELEMENTS SHALL BE SOLIDLY GROUTED. ALL MASONRY CELLS SUPPORTING BEAMS OR COLUMNS SHALL BE GROUTED SOLID FOR A MINIMUM OF 3 COURSES BELOW BEARING POINT.
CONSTRUCTION SHALL BE INSPECTED PER THE REQUIREMENTS OF THE LOCAL CODE OFFICAL.
INTERORIOR ARCHITECTURAL MILLWORK
WORK INCLUDES CUSTOM BUILT IN CABINETS AND SHELVING AS INDICATED ON THE DRAWINGS
COUNTERTOPS
PROVIDE CUSTOM LAMINATE COUTER TOPS WITH BACK SPLASHES AT ALL COUNTER AND VANITIES
COORDINATE COLOR WITH FINISH KEY
CUSTOM CABINETS SHALL INCLUDE LAMINATED WOOD PLYWOOD FRONTS WITH FLUSH DOORS INCLUDING CONCEALED EURO-HINGES.
PULLS TO BE SELECTED BY OWNER
PROVIDE BLOCKING AS REQUIRED IN WALLS TO INSTALL ALL MILWORK AND HANDRAILS
INTERIOR CONSTRUCTION TO BE 3/4" PLYWOOD COVERED IN WHITE MELAMINE
SEALANTS
PROVIDE JOINT SEALANTS AS REQUIRED BY EXTERIOR OR INTERIOR CONSTRUCTION CONDITION
ALL INTERIOR SEALANTS SHALL BE LOW-VOC
SEALANTS SHALL BE BT PECORA, TEMCO, OR DOW.
INTERIOR LATEX SEALANT: PECORA AC-20+. COMPLY WITH ASTM C 834, TYPE OP, GRADE NF.
INTERIOR SINGLE-COMPONENT MILDEW-RESISTANT SILICONE SEALANT: PECORA 898. TYPE, S GRADE NS, CLASS 25, USE, NT, M, G, A, AND O. USE O
JOINT SUBSTRATES: GALVANIZED STEEL AND CERAMIC TILE.
FLOORING
PROVIDE NEW RESINOUS FLOORING IN BOTH BATHROOMS, HALLWAY, AND TRAINING ROOM
BASIS OF DESIGN PRODUCT: DUR-A-FLEX DUR-A-QUARTZ SEE FINISH SCHEDULE FOR MORE DETAILS.
WRAP RESINOUS FLOORING UP THE WALL AROUND PERIMETER OF THE TRAINING ROOM, 6".
INSTALL FLOORING FOLLOWING MANUFACTURER'S INSTALLATION GUIDE.
USE INSTALLATION PRODUCTS RECOMMENDED BY FLOORING MANUFACTURER. TEST CONCRETE SUBSTRATES TO VERIFY AND RECEIVE FLOOR
MANUFACTURER'S ACCEPTANCE OF COMPLIANCE PRIOR TO PROCEEDING WITH INSTALLATION.
PROVIDE NEW TRANSITIONS STRIPS GOING INTO THE TWO BATHROOMS, USE PEMKO COMMERCIAL THRESHOLDS: SADDLE THRESHOLDS 151 _ 3".
CHOOSE FINISH TO MATCH.
TILE
COMPLY WITH TCA'S HANDBOOK FOR CERAMIC TILE INSTALLATION FOR TCA INSTALLATION METHODS SPECIDFIED IN TILE INSTALLATION SCHEDULES
COMPLY WITH ANSI A 108 SERIES SPECIFCATIONS FOR INSTALLION OF CERAMIC TILE
EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPEMENT AND FIXTURES TO FORM COMPLETE COVERING WITHOUT INTERRUPTIONS UNLESS OTHERWISE INDICATED TERMINATE WORK NEATLY AT OBSTRUCTIONS EDGES AND CORNERS WITHOUT DISRUPTING PATTERN OR JOINT
ALIGNMENTS.
ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM CUTTING AND DRILLING OF TILE WITHOUT MARRING VISIBLE SURFACES. CAREFULLY GRIND CUT EDGES OF TILE ABUTTING TRIM FINISH OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED JOINTS. FIT TILE CLOSELY TO ELECTRICAL OUTLETS PIPING
AND OTHER PENETRATIONS SO PLATES COLLARS OR COVER OVERLAP TILE
PROVIDE ALL TRIM PIECES AND ACCESSORIES REQUIRE TO COMPLTE THE WORK
UNLESS OTHER WISE NOTED INSTALL ALL TILE WITH 1/16" GROUT JOINTS
GROUT SHALL BE LATICRETE SPECTRALOCK PRO COLOR SELECTED FROM MANUFACTURERS FULL RANGE
PAINTING
DO NOT PROCEED WITH PAINTING UNLESS SUBSTRATES ARE CURED, DRY AND PROPERLY PREPARED.
PAINT WHEN THE TEMPERATURES ARE BETWEEN 50 AND 95 DEGREES FAHRENHEIT, OR AS RECOMMENDED BY THE PAINT MANUFACTURER. STORE PAINT
PRODUCTS IN CONDITIONED AREAS.
PROTECT PAINTED FINISHES FROM MOISTURE AND ADVERSE WEATHER CONDITIONS
USE LOW-VOC PAINTS AND COATINGS AT ALL INTERIOR LOCATIONS, VENTILATE ENCLOSED AREAS WHEN PAINTING
CMU BLOCK -
1 COAT OF SHERWIN-WILLIAMS LOXON PRIMER (SW- LX02W0050)
2 COATS SHERWIN-WILLIAMS PRO-INDUSTRIAL PRE-CATALYZED WATERBASED EPOXY SEMI-GLOSS (SW - K46-1150 SERIES)
HALLOW METAL DOORS -
1 COAT SHERWIN-WILLIAMS PRO INDUSTRIAL PRO-CRYL UNIVERSAL PRIMER (SW-B66-1300 SERIES) 2 COATS SHERWIN-WILLIAMS PRO-INDUSTRIAL PRE-CATALYZED WATERBASED EPOXY SEMI-GLOSS (SW - K46-1150 SERIES)
MATCH EXISTING SURROUNDING PAINT COLORS. PAINT SAMPLE MOCKUP OF WALL COLORS FOR REVIEW BY THE OWNER AND ARCHITECT PRIOR TO PROCEEDING WITH FINAL COATS. PAINT TO THE OUTSIDE CORNERS OR OTHER LINE IN THE EXISTING CONSTRUCTION SO THAT CHANGE FROM NEW
TO OLD FINISH IS NOT VISIBLE.
VERIFY TYPE OF EXISTING PAINT FINISH AND USE PAINT FINISHES WHICH ARE COMPATIBLE AND RECOMMENDED FOR COVERING EXISTING PAINT
MATERIAL
APPLY PAINT FINISHES FOLLOWING MANUFACTURERS SPECIFICATIONS RECOMMENDATIONS AND AND INSTRUCTIONS PRIME SURFACES AND APPLY TWO FINISH COATS MINIMUM. FINAL PAINTED SURFACES SHALL BE SMOOTH AND PROVIDE AN EVEN OPAQUE FINISH REMOVE HARDWARE FIXTURES FURNISHINGS AND OTHER REMOVABLE ELEMENTS FROM WORK AREA PRIOR TO PAINTING REINSTALL REMOVED ELEMENTS TO ORIGINAL POSITION CONDITIONS AND OPERATION AFTER PAINTING IS COMPLETE
PROVIDE OWNER WITH LARGE SCALE PAINT SAMPLE FOR REVIEW
PROTECT SURROUNDING AREAS FROM PAINT SPILLS, DRIPS, AND SPRAYS. REMOVE ANY DRIPS OR SPILLS OR REPLACE AFFECTED FINISHES AFTER PAINT
WORK IS COMPLETE.
PARTITIONS
PROVIDE NEW BATHROOM PARTITIONS
BASIS OF DESIGN: ASI GLOBAL PARTITIONS - SOLID PLASTIC (HDPE) - CHARCOAL #9237
INSTALL PARTITIONS FOLLING MANUFACTURER'S INSTALLATION GUIDE
INSTALL PARTITION IN OVERHEAD BRACED STYLE
INSTALL PARTITIONS SECURE TO WALL, PROVIDE BLOCKING AS REQUIRED. INSTALL PARTITIONS PLUMB AND SQUARE. USE HARDWARE BY PARTITION
MANUFACTURER.
REVISIONS
HOLLOW METAL FRAMES
BUILDING DATA
ALL WORK SHALL CONFORM TO ALL APPLICABLE CODE STANDARDS AND GOVERNING
AUTHORITIES INCLUDING BUT NOT LIMITED TO:
BUILDING: 2018 VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC)
2018 VIRGINIA CONSTRUCTION CODE (VCC)
2018 VIRGINIA EXISTING BUILDING CODE
(CHAPTER 6 SECTIONS602 & 603 - LEVEL 2 ALTERATIONS)
MECHANICAL: 2018 VIRGINIA MECHANICAL CODE (VMC)
PLUMBING: 2018 VIRGINIA PLUMBING CODE
ELECTRICAL: 2017 NATIONAL ELECTRICAL CODE (NFPA 70)
ENERGY: 2018 VIRGINIA ENERGY CONSERVATION CODE (VECC)
ACCESSIBILITY 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (ASAD), 09/15/2010
STATE: 2022 CONSTRUCTION & PROFESSIONAL SERVICES MANUAL (CPSM)
-REV 2/14/2023
HIGH PERFORMANCE BUILDING ACT WILL NOT APPLY TO THIS PROJECT
BUILDING OCCUPANT LOAD (IBC TABLE 1004.1.2)
BUILDING TOTAL OCCUPANTS: 1,153 , NO CHANGE
PLUMBING FIXTURES (IBC 2902) (IPC 403) (IPC 419.2)
TOTAL OCCUPANTS: EXISTING NO CHANGE
TOTAL FIXTURES: EXISTING, NO CHANGE
EGRESS REQUIREMENTS (IBC CHAPTER 10)
EXITS REQ'D PROVIDED
1ST FLOOR 4 8
MAX EXIT ACCESS TRAVEL DISTANCE: 200 FT
MAX COMMON PATH: 75 FT
MAX DEAD END: 20 FT
EGRESS WIDTH : 0.2"/OCC. (DOORS, RAMPS, CORRIDORS)
(IBC 1005.3)
FIRE-RESISTANCE RATING
INTERIOR FINISHES (IBC TABLE 803.11)
(IBC TABLE 601)
CONSTRUCTION TYPE: IIB
BUILDING ELEMENT: REQ. RATING:
STRUCTURAL FRAME: 0
BEARING WALLS:
INTERIOR: 0
EXTERIOR: 0
FLOOR CONSTRUCTION: 0
ROOF CONSTRUCTION: 0
VERTICAL EXIT ENCLOSURES: NA
SHAFT ENCLOSURES: NA
FIREWALL: 2 HR
NOTES:
OCCUPANCY: A3 FINISH CLASS:
EXITS & PASSAGEWAY: A
EXIT ACCESS CORRIDOR: A
ROOMS AND ENCLOSED SPACES: C
CLASS A: FLAME SPREAD 0-25: SMOKE DEVELOPED 0-450
CLASS B: FLAME SPREAD 26-75: SMOKE DEVELOPED 0-450
CLASS C: FLAME SPREAD 76-200: SMOKE DEVELOPED 0-450
CODE INFORMATION
USE GROUP: A4 NON-SEPARATED MIXED USE
CONSTRUCTION TYPE: IIB (unprotected non-combustible)
AUTOMATIC SPRINKLER SYSTEM: NO
FIRE ALARM: YES
EXISTING HEIGHT: EXISTING HEIGHT 33'-0" +/-, NO CHANGE
EXISTING AREA: 33,620 SF +/-, NO CHANGE
(EGRESS PATH)
(EGRESS PATH)
(EGRESS PATH)
(EGRESS PATH)
(EGRESS PATH)
WORK AREA: BATHROOM FIXTURE
AND FINISH UPGRADES,
WATERFOUNTAIN REPLACEMENT,
CORRIDOR FINISHES, TRAINING
ROOM MILLWORK REPLACEMENT,
RELOCATION OF EQUIPMENT, AND
FINISH UPGRADES
NORTH
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A0.10
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
LIFE SAFETY & CODE
PLAN
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
1/16" = 1'-0"A0.10
3 LIFE SAFETY - FIRST FLOOR
SCALE: 1/16" = 1'-0"
0' 8' 16' 32' 48'
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A0.30
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
EXISTING PHOTOS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
1/2" = 1'-0"A0.30
17 EXISTING HALLWAY
1/2" = 1'-0"A0.30
13 WATER FOUNTAIN
1/2" = 1'-0"A0.30
14 DOUBLE WATER FOUNTAIN
1/2" = 1'-0"A0.30
16 WOMEN'S STALL
1/2" = 1'-0"A0.30
5 URINAL'S
1/2" = 1'-0"A0.30
2 WOMEN'S SINKS
1/2" = 1'-0"A0.30
1 MEN'S SINKS
1/2" = 1'-0"A0.30
3 WOMEN'S STALL
1/2" = 1'-0"A0.30
7 WORKROOM FRIDGES
1/2" = 1'-0"A0.30
4 TOILET
1/2" = 1'-0"A0.30
8 WHITE FRIFDGE AND SINK AREA
1/2" = 1'-0"A0.30
9 WORK AREA
1/2" = 1'-0"A0.30
12 BATHROOM FLOOR DRAINS
1/2" = 1'-0"A0.30
10 WORK ROOM FLOOR DRAINS
1/2" = 1'-0"A0.30
6 WOMEN'S PAPER TOWEL DISPENSER
1/2" = 1'-0"A0.30
11 VENT
OS
NEW CONSTRUCTION
EXISTING CONSTRUCTION
TO REMAIN
KEY NOTEXX
PLAN LEGEND
1'
1/
2" 1'
9/
1'
4"
1'
7"
DEMOLITION GENERAL NOTES
DEMOLITION KEY NOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
DEMOLISH EXISTING WALL TILE AND SETTING MATERIALS, PATCH AND REPAIR EXISTING CMU WALL TO
RECEIVE NEW FINISH.
DEMOLISH EXISTING FLOOR TILE INSTALLATION DOWN TO CONCRETE. REMOVING EXISTING THICKSET SETTING MORTAR. PROVIDE NEW CONCRETE TOPPING TO SLOPE INSTALLATION TO DRAINS. PROVIDE TOPPING COMPATIBLE WITH FLOOR FINISH AND PREPARE SUBSTRATE AS REQUIRED BY FLOOR FINISH
MANUFACTURER.
PATCH OR REPAIR CEILINGS AS REQUIRED FOR INSTALLATION OF NEW LIGHT FIXTURES AND CEILING
DEVICES AS SHOWN ON THE ELECTRICAL DRAWINGS.
DEMOLISH EXISTING TOILET PARTITIONS AND ACCESSORIES.
DEMOLISH EXISTING PLUMBING FIXTURES AND PREPARE ROUGH-IN FOR THE INSTALLATION OF NEW FIXTURES
PER THE PLUMBING DRAWINGS.
DEMOLISH EXISTING VCT TILE INSTALLATION DOWN TO CONCRETE. REMOVING EXISTING SETTING MATERAL
AND SHOT BLAST EXISTING CONCRETE PER FLOORING FINISH MANUFACTURER'S GUIDELINES.
SALVAGE AND RELOCATE EXISTING ICE MAKER.
SALVAGE AND RELOCATE ONE EXISTING REFRIGERATOR. DEMOLISH OTHER REFRIGERATOR AS DIRECTED BY
OWNER. CONFIRM WITH OWNER WHICH REFRIGERATORS WILL BE RETAINED OR DEMOLISHED.
DEMOLISH EXISTING MILLWORK. PATCH HOLES IN WALLS TO PRODUCE SMOOTH SURFACE FOR NEW WALL
FINISH
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
THESE DRAWINGS ARE BASED ON HISTORICAL DRAWINGS AND LIMITED FIELD INVESTIGATIONS OF THE EXISTING BUILDING. CONTRACTOR SHALL VERITY ALL CONDITIONS PRIOR TO CONSTRUCTION OR
FABRICATION. MODIFICATIONS SHALL BE MADE ONLY AFTER APPROVAL BY ARCHITECT.
ALL DIMENSIONS ARE NOMINAL. FIELD VERIFY ALL DIMENSIONS. NOTIFY THE ARCHITECT IF EXISTING CONDITIONS DEVIATE FROM THOSE SHOWN ON THE DRAWINGS, PRIOR TO EXECUTING THE WORK.
PROTECT ALL EXISTING CONSTRUCTION TO REMAIN. IF EXISTING CONSTRUCTION TO REMAIN IS DAMAGED DURING DEMOLITION THEN THE CONTRACTOR SHALL REPAIR OR REPLACE TO MATCH THE ORIGINAL
CONDITIONS.
MAINTAIN EXISTING BUILDING IN A SECURE AND WEATHERTIGHT CONDITION AT ALL TIMES. BOARD UP AND
PROVIDE TEMPORARY OPENING PROTECTION AS REQUIRED.
PRIOR TO REMOVAL OR MODIFICATION OF WALLS OR OTHER POTENTIALLY LOAD BEARING ELEMENTS, THE ACTUAL SIZE AND LOCATION OF STRUCTURAL COMPONENTS AND LOAD BEARING CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR BY MEANS OF SELECTIVE DEMOLITION. THE CONTRACTOR SHALL NOTIFY THE
A/E OF ANY UNUSUAL OR HAZARDOUS CONCEALED CONDITIONS.
PROVIDE ALL TEMPORARY BRACING AND SHORING NECESSARY TO SAFELY SUPPORT ALL LOADS WHILE
MAKING MODIFICATIONS REQUIRED BY THE WORK.
REMOVE EXISTING CONSTRUCTION WHERE SHOWN AS DASHED LINES.
MAINTAIN FIRE EXTINGUISHING EQUIPMENT AT ALL TIMES.
DO NOT USE TOOLS OR EQUIPMENT WHICH COULD IGNITE COMBUSTIBLE CONSTRUCTION.
REFER TO ALL DRAWING AND SPECIFICATIONS AS THEY REGARD TO DEMOLITION, INCLUDING BUT NOT
LIMITED TO, STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL, & ARCHITECTURAL.
REMOVE AND TERMINATE ABANDONED ELECTRICAL, PLUMBING, MECHANICAL, OR UTILITY SYSTEMS.
TERMINATE CONCEALED INACCESIBLE SYSTEMS AS REQUIRED BY CODE.
REMOVE ALL FINISHES AND SUBSTRATES AS REQUIRED FOR THE INSTALLATION OF NEW FINISHES. PREPARE SUBSTRATES FOR NEW FINISHES AS RECOMMENDED BY THE FINISH MANUFACTURER. WHERE NEW MATERIAL OR FINISHES TIE INTO EXISTING, OR WHERE PATCHING IS REQUIRED, PATCH SURFACES AND REPAIR TO CREATE SEAMLESS, SMOOTH, AND UNNOTICIABLE TRANSITIONS BETWEEN EXSTING AND NEW MATERIALS.
REMOVE CONCRETE AS REQUIRED FOR INSTALLATION OF NEW PLUMBING AND TO PROVIDE DRAINAGE TO NEW FLOOR DRAINS WHERE INDICATED. PATCH AND REPAIR CONCRETE AFTER INSTALLATION AS REQUIRED.
WHERE CEILINGS ARE TO BE DEMOLISHED REMOVE ALL LIGHT FIXTURES & DEVICES. REF. ELCTRICAL, PLUMBING, SPRINKLER, AND MECHANICAL FOR ADDITIONAL INFORMATION REGARDING MODIFICATIONS
FOR NEW WORK.
MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE.
IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; NOTIFY THE OWNER &
ARCHITECT IMMEDIATELY FOR REVIEW & ADDITIONAL DIRECTION.
COMPLY WITH DISPOSAL REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. THE OWNER HAS FIRST
RIGHT OF REFUSAL FOR ALL DEMOLISHED MATERIALS.
IN AREAS OF WORK, REMOVE AND SALVAGE ALL INTERIOR AND EXTERIOR PLAQUES AND SIGNAGE, WALL MOUNTED TV'S, SECURITY CAMERAS, EXTERIOR LIGHTS, AND SPEAKERS. PROVIDE TO OWNER FOR STORAGE
AND/OR REUSE. REINSTALL WHERE NOTED.
IN ALL AREAS THAT SHOW NEW WORK, AND NEW FLOOR FINISHES, DEMO EXISTING FLOOR TO CONCRETE SLAB AND PREP SLAB AS REQUIRED BY THE NEW FINISH MANUFACTURERS INSTALLATION INSTRUCTIONS AND
WARRANTY REQUIREMENT.
DEMOLITION LEGEND
EXISTING WALLS TO REMAIN
BUILDING ELEMENTS TO BE DEMOLISHED
KEY NOTEXX
11 1/2"
A8.01
A8.01
A8.02
9'
1/
2" 3'
5/ 8"
5'
5/
8" 3'
5/ 8"
9'
7/
8"
6'
6"
2' - 3 3/4" 10' - 3 7/8" 1' - 5 1/8" 13' - 2 1/2" 0"
13' - 1 3/4" 1' - 5 1/8"
5' - 0 9/16"
ICE MACHINE
REFRIGERATOR
A8.01
A8.01 10 Sim
WOMEN'S RR
TRAINING ROOM
103MEN'S RR
CORRIDOR
HALLWAY
A8.02
A8.02
A8.02 6 Sim
A8.01
A8.01
AMBULATORY ACCESSIBLE
TOILET STALL
EXTEND CONCRETE PAD TO MEET
EXISTING WALKWAY
A8.01
A8.028
NORTH
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A2.01
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
FLOOR PLANS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
A4.01A2.01 1/4" = 1'-0"
FIRST FLOOR PLAN -
DEMOLITION PLAN
A4.01A2.01 1/4" = 1'-0"
REFLECTED CEILING
PLAN
1/8" = 1'-0"A2.01
4 DEMO GEN AND KEY NOTES
SCALE: 1/4" = 1'-0"
0' 2' 4' 8' 12'
A4.01A2.01 1/4" = 1'-0"
1 FIRST FLOOR PLAN
A2.01
TOILET ACCESSORY LEGEND
INSTALL ALL FIXTURES, GRAB BARS,
AND ACCESSORIES TO MEET ADA
REQUIREMENTS
7 - 9" MAX
24" MIN
12" MIN
16 - 18" MAX
" M
A X
42" MIN12" MAX
54" MIN
" M
A X
" M
IN
39 - 41" MAX
" M
IN
" M
A X
36" MIN
8 2
" M
A X
" M
A X
" M
A X
MAX REACH RANGE FOR
DISPENSERS AND WORK SURFACES
" M
A X
" M
IN
ADA COMPLIANT
PIPE INSULATION
BOBRICK SURFACE-MOUNTED TWIN JUMBO-
ROLL TOLIET TISSUE DISPENSER B-2892
BOBRICK HORIZONTAL SS GRAB BAR (3'-6") B-6806 42
BOBRICK SS SURFACE MOUNTED SEAT-
COVER DISPENSER B-221
BOBRICK VERTICAL SS GRAB BAR (1'-6") B-6806 18
BOBRICK SS TILT FRAMED MIRROR B-293 1830
BOBRICK SS SURFACE-MOUNTED
SOAP DISPENSER B-4112
WALL MOUNTED URINAL, REF. MEP
BOBRICK SS SANITARY DISPOSAL B-254
DYSON AIRBLADE V HAND DRYER SPRAYED NICKEL HU02
9 WATER FOUNTAIN, REF. MEP
EXISTING CMU
WALL TO REMAIN
CUT TILE: SO PATTERN IS GOING VERTICAL
BULLNOSE TILE
NEW TILE. SEE FINISH SCHEDULE
1/ 2"
5/
8"
THIN SET MORTAR
WT-1 HORIZONTALWT-4 WT-2WT-1 VERTICAL
TOILET PARTITION
WT-1 HORIZONTAL
WT-2
TOILET PARTITION
EXISTING DOOR
TO REMAIN
WT-1 VERTICALWT-1 HORIZONTAL
WT-1 VERTICAL
WT-4WT-2
ADA COMPLIANT
SINK INSULATION
WT-1 HORIZONTALWT-4
TOILET PARTITION
1 1 1
WT-1 HORIZONTALWT-3
2'
4'
3/
4"
WT-1 HORIZONTAL
WT-2
TOILET PARTITION
WT-1 VERTICAL
EXISTING DOOR
TO REMAIN
WT-1 HORIZONTAL
WT-1 HORIZONTAL WT-1 VERTICAL
WT-4
WT-1 HORIZONTALWT-3
1 1
URNIAL PARTITION
EXISTING DOOR
TO REMAIN
WT-1 VERTICAL
WT-4 WT-2
URINAL PARTITION
ADA COMPLIANT
SINK INSULATION
WT-1 VERTICAL
WT-2WT-1 HORIZONTAL
TOILET PARTITION
3 4
ADA COMPLIANT
SINK INSULATION
WT-1WT-4
4'
3/
4"
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A8.01
PROJ. NO.: 236007
DATE: 7/5/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
BATHROOM PLANS,
ELEVATIONS &
DETAILS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
3" = 1'-0"A8.01
10 TILE CORNER DETAIL
SCALE: 3" = 1'-0"
0' 3" 6" 1'1"
3/8" = 1'-0"A8.01
11 MEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
12 MEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
14 BATHROOM STALL ELEVATION
3/8" = 1'-0"A8.01
1 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
3 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
2 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
6 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
4 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
5 WOMEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
7 MEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
8 MEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
9 MEN'S BATHROOM ELEVATION
3/8" = 1'-0"A8.01
13 MEN'S BATHROOM ELEVATION
SCALE: 3/8" = 1'-0"
0' 1' 2' 4' 6' 8'6"
REVISIONS
7/21/23
PLAM-2
PLAM-1
EXISTING DOOR
TO REMAIN
PLAM-1
PLAM-2
PLAM-1
PNT-1
A8.03
Sim
EXISITNG ICE MACHINE
RESB
PLAM-1
PLAM-2
PNT-1
2' - 6" 3' - 0"
RESB
PNT-1
PLAM-2
PLAM 1
PLAM-2
PLAM 1
PLAM 1
RICHARD BLAND STATESMEN
8"
2' - 0"
VINYL GRAPHICS
TO BE APPLIED TO
LAMINATE AFTER
INSTALLATION
PLAM-3
4' - 0 1/8"18' - 3"4' - 0 1/8"2' - 0"
8"
PNT-2 PNT-1 EXTEND PAINT TO NEAREST
INSIDE CORNER OF ADJACENT
COLUMN
PNT-1 RETURN ONTO
ADJACENT WALL AND END
ON INSIDE CORNER
5'
/4
3' - 5 5/8"
NEW PLAM COVER AT EACH
WATER FOUNTAIN LOCATION
1'
8"
A8.03
Sim
A8.03
Sim
EXISITING
REFRIGERATOR
PLAM-1
PLAM-1
PLAM-2
PNT-1
1' - 3" 3' - 0" 3' - 0" 1' - 3"
1' - 3" 3' - 0" 3' - 0" 1' - 3"
A8.02
2X4 FURRING STRIPS
3/4" PLYWOOD
SUBSTRATE & 1/16"
LAMINATE
WATER COOLER &
BOTTLE FILLER
EXISTING CMU
WALL TO REMAIN
TILE BASE
3'
1"
4"
3/4" PLWOOD SUBSTRATE
LAMINATE MATERIAL
FORMICA HARDSTOP ALUMINUM TRIM:
AT20 OUTSIDE CORNER - 101 CHAMPAGNE
FORMICA HARDSTOP ALUMINUM TRIM
AT40 END CAP - 101 CHAMPAGNE
BUTT JOINT W/ SEALANT AS
REQUIRED BY MANUFACTURER
LAMINATE MATERIAL
1' - 4" +/-
2' - 5 5/8" +/-
PNT-2PNT-1
RB-1
ALIGN CORNER OF ANGLE TO
START OF NEW FLOOR FINISH
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A8.02
PROJ. NO.: 236007
DATE: 7/5/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
INTERIOR ELEVATIONS
& DETAILS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
A2.01A8.02 1/2" = 1'-0"
TREATMENT ROOM
ELEVATION
SCALE: 3" = 1'-0"
0' 3" 6" 1'1"
1/2" = 1'-0"A8.02
1 TREATMENT ROOM ELEVATION
1/2" = 1'-0"A8.02
2 TREATMENT ROOM ELEVATION
3/8" = 1'-0"A8.02
3 PROPOSED HALLWAY DESIGN
1/2" = 1'-0"A8.02
4 TREATMENT ROOM ELEVATION
1 1/2" = 1'-0"A8.02
6 WATER FOUNTAIN DETAIL
6" = 1'-0"A8.02
7 LAMINATE TRIM DETAIL
SCALE: 6" = 1'-0"
0' 2" 3" 6"1"
1/2" = 1'-0"A8.02
8 NORTH & SOUTH CORRIDOR ELEVATION
SCALE: 1/2" = 1'-0"
0' 1' 2' 4' 6'
REVISIONS
# DATE DESCRIPTION
. NO.: 236
7/21/23
WN BY: STT
4" 2'
6"
1'
8" 2'
6"
WALL CLEATS
PEG SHELF RESTS
ADJUSTABLE SHELVING: 3/4" CORE
DOOR FRONT: 3/4" CORE
FACED W/ PLAM-1
PULL
1'
1/ 4"
6"
1/ 4"
1/
2"
3" 1' - 9"
LAMINATE BASE
CONTINUOUS CLEATS
CABINET CONSTRUCTION: 3/4"
CORE W/ WHITE MELAMINE
4" PLAM-2
BACKSPLASH
PLAM-2 COUNTER TOP OVER
3/4" MOISTER RESISTANT BASE.
PLAM-1 DRAWERS 3/4"CORE
WITH WHITE MELAMINE
1' - 0"
4"
PEG SHELF RESTS
ADJUSTABLE SHELVING: 3/4"
CORE W/WHITE MELAMINE
3/4"
TOE KICK TYP
CABINET CONSTRUCTION: 3/4" CORE
3" 1' - 9"
4" 2'
6"
1'
8" 2'
6"
4"
1/
2"
1/ 4"
6"
1/ 4"
6"
1/ 4"
6"
1/ 4"
1/
2"
PLAM-2
PLASTIC LAMINATE
COUNTER TOP W/ PLAM-2
CONTINUOUS CLEATS
PLASTIC LAMINATE
DRAWERS W/ PLAM-1
LAMINATE BASE
WALL CLEATS
PEG SHELF RESTS
PLASTIC LAMINATE
ADJUSTABLE SHELVES
PLASTIC LAMINATE
CABINET FRONT W/ PLAM-1
PULL
1' - 0"
3/4"
LAMINATE BASE
CONTINUOUS CLEATS
PLASTIC LAMINATE
CABINET FRONTS
W/ PLAM-1
PLAM-2 COUNTER TOP
OVER 3/4" MOISTER
RESISTANT BASE
1X TREATED WOOD
BLOCKING AROUND SINK
SINK AND
FAUCET BY
PLUMBING
PLAM-2 BACKSPLASH SET IN
MASTIC, SCRIBE TO WALL
3"
4" 2'
6"
1'
8" 2'
6"
4"
1' - 9"
1/
2"
1/ 4"
6"
1/ 4"
1'
WALL CLEATS
PEG SHELF RESTS
PLASTIC LAMINATE
ADJUSTABLE SHELVES
PLASTIC LAMINATE
CABINET FRONT W/ PLAM-1
PULL
1' - 0"
1 1/8"
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A8.03
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
MILLWORK
ELNARGED PLANS,
SECTIONS & DETAILS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
1 1/2" = 1'-0"A8.03
1 SECTION THROUGH CABINET W/ DRAWERS
1 1/2" = 1'-0"A8.03
2 SECTION THROUGH DRAWERS
1 1/2" = 1'-0"A8.03
3 SECTION THROUGH SINK
SCALE: 1-1/2" = 1'-0"
0' 6" 1' 2'3"
ADA COMPLIANT METAL TRANSITION STRIP,
USE PEMKO COMMERCIAL THRESHOLDS:
SADDLE THRESHOLDS 151 _ 3"
EXISITNG TERRAZZO FLOOR
DOOR, SEE SPEC & FINISH PLAN FOR
LOCATIONS
RESINOUS FLOORING, SEE FINISH
SCHED.
CONCRETE SLAB, TYP.
PROVIDE TOPPING SLAB AND LEVELING
COMPOUND AS REQUIRED TO ACHIEVE
FLOOR LEVEL AND SMOOTH SURFACE.
PROVIDE PRODUCTS COMPATIBLE WITH
FLOOR FINISH MANUFACTURER
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
CONSULTANT
LOGO
A9.03
PROJ. NO.: 236007
DATE: 7/21/23
DRAWN BY: STT
RI
C
HA
RD
B
LA
ND
C
O
LL
EG
E
G
YM
B
AT
HR
O
O M
FINISH SCHEDULE &
DETAILS
WORKING
DRAWINGS
JO
HN
SO
N
RD
SO
UT
H
PR
IN
C E
G
EO
RG
E, V A
FINISH SCHEDULE
NUMBER NAME
WALL FINISH
FLOOR FINISH BASE FINISH CEILING FINISHNORTH EAST SOUTH WEST
101 WOMEN'S RR WT-1/WT-2/WT-4 WT-1/WT-3 WT-1/WT-4 WT-1/WT-3 RESF - PNT-3
102 MEN'S RR WT-1/WT-4 WT-1/WT-2 WT-1/WT-2/WT-4 WT-1/WT-3 RESF - PNT-3
103 TRAINING ROOM PNT-1 PNT-1 PNT-1 PNT-1 RESF RESB EXISTING - REPLACE DAMAGED
104 CORRIDOR PNT-1/PNT-2 - PNT-1/PNT-2 - RESF RB-1/EXISTING EXISTING - REPLACE DAMAGED
105 HALLWAY - PNT-1/PNT-2/PLAM-3 - - EXISTING EXISITNG -
6" = 1'-0"A9.03
1 TRANSITIONS-VCT TO LIN
PLAM-3 PLASTIC LAMINATE FORMICA HARD STOP STORM
PLAM-2 PLASTIC LAMINATE WILSON ART GRAPHITE
PLAM-1 PLASTIC LAMINATE WILSON ART - ASTRO STRANDZ
MILLWORK
RESF RESINOUS FLOORING DUR-A-FLEX DUR-A-QUARTZ Q11-23 (2) GROUT COATS (20 MILS TOTAL) ARMOUR TOP GLOSS
FLOOR FINISHES
RB-1 RUBBER BASE 1 JOHNSONITE TRADITIONAL VINYL 40 BLACK 4"
RESB RESINOUS INTERGRATED BASE DUR-A-FLEX DUR-A-QUARTZ Q11-23 (2) GROUT COATS (20 MILS TOTAL) ARMOUR TOP GLOSS
BASE FINISHES
WT-4 WALL TILE -4 BEST TILE BAMBUSA CREMA 2.5" x 24" INSTALL WALL TILE PER INTERIOR ELEVATIONS WT-3 WALL TILE-3 BEST TILE TAPESTRY VISION 0010 4" x 16" INSTALL WALL TILE PER INTERIOR ELEVATIONS WT-2 WALL TILE-2 BEST TILE TAPESTRY VISION 005G 12" x 36" INSTALL WALL TILE PER INTERIOR ELEVATIONS WT-1 WALL TILE-1 BEST TILE BAMBUSA CREMA 12" x 24" INSTALL WALL TILE PER INTERIOR ELEVATIONS
PNT-3 PAINT-3 CEILING PAINT MATCH EXISITNG
PNT-2 PAINT-2 ACCENT PAINT CUSTOM COLOR TO MATCH: PANTONE 343 CUSTOM COLOR MATCH PANTONE 343 GREEN
PNT-1 PAINT-1 TYPICAL WALL PAINT MATCH EXISTING TYPICAL CMU COLOR
WALL FINISHES
FINISH KEY DESCRIPTION MANUFACTURER PRODUCT LINE/NO. COLOR NAME/NO. SIZE (NOMINAL) COMMENTS
FINISH KEY
PLUMBING GENERAL NOTES
1. WORK INCLUDES PROVIDING A FIRST CLASS WORKING SYSTEM, TESTED AND READY FOR OPERATION, COMPLETE WITH LABOR, MATERIALS, APPARATUS, TRANSPORTATION, AND TOOLS REQUIRED FOR THE INSTALLATION, AS INDICATED.
2. ALL WORK SHALL COMPLY WITH 2018 VIRGINIA CONSTRUCTION CODE AND LOCAL BUILDING CODES, THE VIRGINIA PLUMBING AND MECHANICAL CODES (VMC 2018, VPC 2018, VFGC 2018, VECC 2018) , NFPA CODES AND ALL OTHER APPLICABLE CODES. OBTAIN PERMITS, INSPECTIONS, LICENSES AND TESTS REQUIRED FOR THIS WORK AND PAY ALL FEES IN CONNECTION THEREWITH.
3. COORDINATE WORK CLOSELY WITH OTHER TRADES. ALL DIMENSIONS SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR, AND SHALL BE VERIFIED AND COORDINATED IN THE FIELD PRIOR TO INSTALLATION. FAILURE TO COORDINATE WORK WILL NOT BE CONSIDERED AS A BASIS FOR
EXTRA PAYMENTS.
4. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT SHOW EXACT LOCATIONS OF FIXTURES, PIPING AND EQUIPMENT. DO NOT SCALE DRAWINGS. ALL OFFSETS AND FITTINGS FOR COMPLETE INSTALLATION MAY NOT BE INDICATED ON THE DRAWINGS. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AT THE BUILDING AND ANY CHANGES NECESSARY FOR COORDINATION WITH EXISTING CONDITIONS. PLUMBING SYSTEMS AND EQUIPMENT SHALL BE INSTALLED AND COORDINATED WITH OTHER WORK. IF CONFLICTS CANNOT BE RESOLVED THEY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT / ENGINEER.
5. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES OF CONSTRUCTION SELECTED BY THE CONTRACTOR OR OF THE SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL TO THE WORK OF THE CONTRACTOR. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR TO PERFORM THE WORK IN ACCORDANCE WITH THE DRAWINGS
AND SPECIFICATIONS.
6. ALL MATERIALS SHALL BEAR THE MANUFACTURER'S NAME, TRADE NAME AND BE U.L. LABELED IF REQUIRED. UNLESS NOTED OTHERWISE, ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE MANUFACTURER. ALL EQUIPMENT OF
A SIMILAR TYPE SHALL BE OF THE SAME MANUFACTURER.
7. GUARANTEE / WARRANTY: ALL PLUMBING EQUIPMENT, MATERIALS AND LABOR REQUIRED BY THESE SPECIFICATIONS AND ACCOMPANYING DRAWINGS SHALL BE GUARANTEED TO BE FREE FROM DEFECTIVE MATERIALS OR WORKMANSHIP FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE OF THE PROJECT EXCEPT EXTENDED WARRANTIES, AS SPECIFIED ELSEWHERE IN THESE DOCUMENTS ON SPECIFIC ITEMS OF
EQUIPMENT, WILL BE FURNISHED BY THE TRADE PROVIDING THE EQUIPMENT.
8. CONTRACTOR SHALL FURNISH LOCATION AND SIZE OF OPENINGS REQUIRED FOR PLUMBING FIXTURES, EQUIPMENT AND PIPING TO THE GENERAL
CONTRACTOR IN TIME NOT TO DELAY BUILDING CONSTRUCTION.
9. PIPE SIZES SHOWN ARE NPS INSIDE DIMENSIONS. COPPER TUBE SIZES ARE FOR NOMINAL TYPE L.
PLUMBING LEGEND
WHA
1. MAKE PROPER SUPPLY AND DRAINAGE PIPING CONNECTIONS TO ALL FIXTURES
AND EQUIPMENT EVEN THOUGH EVERY BRANCH PIPE AND FITTING MAY NOT BE
GRAPHICALLY INDICATED.
2. VERIFY FIXTURE LOCATIONS WITH ARCHITECTURAL WORKING DRAWINGS
BEFORE ROUGHING-IN PLUMBING FIXTURES.
3. PIPING SLOPES AND INVERT ELEVATIONS OF SEWERS, MANHOLES, SEPTIC
TANKS, ETC. SHALL BE ESTABLISHED AND VERIFIED BY THE PLUMBING
CONTRACTOR PRIOR TO PIPING INSTALLATION IN ORDER THAT PROPER SLOPES
ARE MAINTAINED AND NECESSARY INVERT ELEVATIONS MET.
4. COORDINATE THE LOCATIONS OF ALL PIPING WITH ELECTRICAL WORK AND
LIGHTING FIXTURES, HVAC PIPING AND DUCTWORK, FIRE PROTECTION PIPING,
STRUCTURAL ELEMENTS AND CEILING CONSTRUCTION, ETC.
5. PROVIDE ALL FLOOR DRAINS WITH STANDARD SEAL P-TRAP, UNLESS
OTHERWISE NOTED. FLOOR DRAIN TRAP SEALS SUBJECT TO LOSS BY
EVAPORATION SHALL BE EQUIPED WITH WATERLESS INLINE DRAIN TRAP SEAL
MODEL SURESEAL AS MANUFACTURED BY RECTORSEAL.
6. ALL SHUTOFF / SERVICE VALVES, WATER HAMMER ARRESTORS, ETC. IN
CONCEALED LOCATIONS SHALL BE ACCESSIBLE. PROVIDE ACCESS DOOR OR
PANEL AS REQUIRED.
7. CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF ALL POINTS OF CONNECTION
FOR NEW-TO-EXISTING WORK PRIOR TO NEW WORK BEING INSTALLED.
8. PROVIDE CLEANOUT AT THE BASE OF ALL NEW SOIL OR WASTE STACKS.
ABBREVIATIONS
WATER HAMMER ARRESTOR
SHUTOFF / SERVICE VALVE (IN PLAN)
DIRECTION OF SLOPE DOWN
SANITARY VENT (RISER VIEW)
SANITARY SOIL & WASTE
HOT WATER
COLD WATER
RISER IN PLAN
SIDE OF MAIN
BOTTOM OF MAIN
TOP OF MAIN
TEE OR ELBOW FROM TOP OF MAIN
GENERAL PLUMBING INSTALLATION NOTES
CHECK VALVE
HOT WATER RETURN
FIXTURE & EQUIPMENT MARKS
PLUMBING PIPING SYSTEMS
S - SANITARY
V - VENT
VTR - VENT-THRU-ROOF
W - WASTE
ABV - ABOVE EX - EXISTING
AD - ACCESS DOOR EL - ELEVATION
BEL - BELOW FL - FLOOR
DN - DOWN INV - INVERT
DFU - DRAINAGE FIXTURE UNIT SFU - SUPPLY FIXTURE UNIT
EXISTING TO REMAIN
EXISTING TO BE REMOVED
EXTENT OF DEMOLITION
POINT OF CONNECTION - NEW TO EXISTING
BFP - BACKFLOW PREVENTER
CO - CLEANOUT
EFD - EMERGENCY FLOOR DRAIN
EWC - ELECTRIC WATER COOLER
FCO - FLOOR CLEANOUT
FD - FLOOR DRAIN
HB - HOSE BIBB
LAV - LAVATORY
OSD - OPEN SITE DRAIN
TMV - THERMOSTATIC MIXING VALVE
UR - URINAL
WH - WALL HYDRANT
WC - WATER CLOSET
WCO - WALL CLEANOUT
C - COLD WATER
H - HOT WATER
HR - HOT WATER RECIRCULATING
DEMOLITION PLAN REFERENCE NOTE
PLAN REFERENCE NOTE
C
AO
M M O N
W
EA
LTH OF
V
I R G I N I
P
O
R O F
E
SS I
N
N
AL EN
G I
R E E07-21-2023
Written dimensions on these drawings shall have precedence over scaled dimensions. Contractors shall verify and be responsible for all dimensions and conditions on the job. The Architect must be notified of any variations from the dimensions and conditions shown on these drawings.
7 NORTH 25TH STREET
RICHMOND, VA 23223
804.861.1200 P
250 WYLDEROSE CMNS, STE 102
MIDLOTHIAN, VA 23113
804.977.0403
INVERSITYCONSULTING.COM
PC: 23041
RICHARD A. POLO
Lic. No. 047236
P0.01
PROJ. NO.: 236007
DATE: 07/21/23 DRAWN BY: JAF
R B
C G
Y M
B A
TH
R
O O
M
PLUMBING - LEGEND
& SCHEDULES
WORKING
DRAWINGS
J O
H N
SO
N
R D
P
E
TE
R
SB
U R
G V
A
7. LAVATORY MOUNTING HEIGHT SHALL BE 34" AFF.
6. PROVIDE WITH RECESSED MOUNTED BOX, OPTIONAL ANODIZED ALUMNIMUM BOX.
5. MOUNT FIXTURE RIM HEIGHT 17" AFF. UR-1 TO BE ARRANGED AND INSTALLED ADA COMPLIANT.
4. PROVIDE FLOOR DRAIN WITH WATERLESS INLINE DRAIN TRAP SEAL, MODEL SURESEAL AS MANUFACTURED BY RECTORSEAL.
3. MOUNT FIXTURE BOWL RIM HEIGHT 16.5", SEAT HEIGHT 17" AFF. PROVIDE WITH OPEN FRONT SEAT SIMILAR TO TOTO SC534. WC-1 TO BE ARRANGED AND INSTALLED ADA COMPLIANT.
2. INSULATE EXPOSED TRAP AND SUPPLIES IN ACCORDANCE WITH ICC A117.1 "ACCESSIBLE AND USABLE BUILDING AND FACILITIES".
1. MOUNTING HEIGHTS OF ALL ACCESIBLE FIXTURES SHALL BE IN ACCORDANCE WITH ICC A117.1 "ACCESSIBLE AND USABLE BUILDING AND FACILITIES".
NOTES:
FLUSH VALVE SLOAN WES 111-1.6/1.1
WC-2
WATER CLOSET
FLOOR MOUNT
FLUSH VALVE
WATER CLOSET, FLOOR MOUNTED, BOTTOM OUTLET, ELONGATED BOWL, VITREOUS CHINA, SIPHON JET, 1 1/2" TOP SPUD, ASME A112.19.2. PROVIDE DIAPHRAGM OPERATED MANUAL FLUSH VALVE, DUAL FLUSH 1.6 / 1.1 GPF, WITH INLET ANGLE STOP AND
OUTLET VACUUM BREAKER, ASSE 1037, 11 1/2" FOR EXISTING ROUGH-IN.
4" 2" 1" -
WATER CLOSET TOTO CT725CUFG
FLUSH VALVE SLOAN WES 111-1.6/1.1
WC-1
WATER CLOSET
FLOOR MOUNT
FLUSH VALVE
WATER CLOSET, FLOOR MOUNTED, BOTTOM OUTLET, ELONGATED BOWL, VITREOUS CHINA, SIPHON JET, 1 1/2" TOP SPUD, ASME A112.19.2. PROVIDE DIAPHRAGM OPERATED MANUAL FLUSH VALVE, DUAL FLUSH 1.6 / 1.1 GPF, WITH INLET ANGLE STOP AND OUTLET VACUUM BREAKER, ASSE 1037, WITH 24" TUBE FOR EXISTING ROUGH-IN, ADA COMPLIANT.
4" 2" 1" -
WATER CLOSET TOTO CT725CUFG
1, 3
FLUSH VALVE TOTO TMU1LN22#CP
UR-2
URINAL WALL
MOUNT
WALL MOUNTED, WASHOUT ACTION, FLUSHING RIM, VITREOUS CHINA, 3/4" TOP SPUD. PROVIDE PISTON OPERATED MANUAL FLUSH VALVE 0.5 GPF, WITH INLET ANGLE STOP AND 1 1/4" OUTLET VACUUM BREAKER, ASSE 1037, 11 1/2" ROUGH-IN, ASME A112.18.2.
2" 1 1/2" 3/4" -
URINAL TOTO UT447E
FLUSH VALVE TOTO TMU1LN22#CP
UR-1
URINAL WALL
MOUNT
WALL MOUNTED, WASHOUT ACTION, FLUSHING RIM, VITREOUS CHINA, 3/4" TOP SPUD. PROVIDE PISTON OPERATED MANUAL FLUSH VALVE 0.5 GPF, WITH INLET ANGLE STOP AND 1 1/4" OUTLET VACUUM BREAKER, ASSE 1037, 11 1/2" ROUGH-IN, ASME
A112.18.2 AND ADA COMPLIANT.
2" 1 1/2" 3/4" -
URINAL TOTO UT447E
1, 5
POT FILLER HANSGROHE 04060000
FAUCET ELKAY LKD2439BHCS-1
SINK COUNTER
MOUNT
31"x22"x6" DEEP, SINGLE BOWL DROP-IN, 18 GAUGE TYPE 304 STAINLESS STEEL, LUSTROUS SATIN FINISH, 4-HOLE, REAR CENTER 3 1/2" DRAIN, 1 1/2" TAILPIECE AND P-TRAP, 1/2" STOPS AND SUPPLIES, ASME A112.19.3. PROVIDE DECK MOUNTED 8" CENTERSET CONCEALED FAUCET, 1.5 GPM, MANUAL LEVER HANDLES, SWING ARC SPOUT, CHROME FINISH, ASME A112.18.1. PROVIDE DECK
MOUNTED POT-FILLER FAUCET, DOUBLE SWING ARM, 2.5 GPM, CHROME FINISH.
1 1/2" 1 1/2" 1/2" 1/2"
SINK ELKAY LRAD312260
1, 2
FAUCET SLOAN
EBF-650-8-BAT-BDT-CP-0.5
GPM-MLM-IR-FCT
LAV-2
LAVATORY WALL
MOUNT
21"x18"x5" DEEP, RECTANGULAR WITH D-BASIN, VITREOUS CHINA, WALL MOUNT WITH HANGER BRACKET, GRID DRAIN, 1 1/4" TAILPIECE AND P-TRAP, 1/2" STOPS AND SUPPLIES, ASME A112.19.2. PROVIDE DECK MOUNTED 4" CENTERSET FAUCET, 0.5 GPM, BELOW DECK MIXING VALVE, INFRARED SENSOR, BATTERY POWERED, MULTI-LAMINAR SPRAY, CHROME FINISH WITH GRID
STRAINER DRAIN. PROVIDE WITH TMV-1. ASME A112.18.1.
1 1/4" 1 1/2" 1/2" 1/2"
LAVATORY TOTO LT307.4
1, 2, 7
FAUCET SLOAN
EBF-650-8-BAT-BDT-CP-0.5
GPM-MLM-IR-FCT
LAV-1
LAVATORY WALL
MOUNT
21"x18"x5" DEEP, RECTANGULAR WITH D-BASIN, VITREOUS CHINA, WALL MOUNT WITH HANGER BRACKET, GRID DRAIN, 1 1/4" TAILPIECE AND P-TRAP, 1/2" STOPS AND SUPPLIES, ASME A112.19.2. PROVIDE DECK MOUNTED 4" CENTERSET FAUCET, 0.5 GPM, BELOW DECK MIXING VALVE, INFRARED SENSOR, BATTERY POWERED, MULTI-LAMINAR SPRAY, CHROME FINISH WITH GRID
STRAINER DRAIN. PROVIDE WITH TMV-1. ASME A112.18.1.
1 1/4" 1 1/2" 1/2" 1/2"
LAVATORY TOTO LT307.4
1, 2, 7
BOTTLE FILLER ELKAY LZWSR
EWC-1
ELECTRIC
WATER COOLER -
SINGLE LEVEL
STATION
REFRIGERATED COOLER, WALL MOUNTED, HEAVY DUTY VANDAL RESISTANT, FILTERED, SINGLE STATION W/ FRONT BUTTON ACTIVATION, AND BOTTLE FILLING STATION, TAILPIECE AND P-TRAP, 1/2" STOP, 3/8" SUPPLY, ASME A112.19.3, ADA COMPLIANT, 8 GPH OF 50 °F WATER AT 90 °F AMBIENT AND 80 °F INLET WATER TEMPERATURE. BOTTLE FILLER SHALL HAVE A MINIMUM 1.0 GPM FLOW ACTIVATED BY ELECTRONIC SENSOR, 20 SECOND SHUT-OFF TIMER AND BOTTLE COUNTER.
1 1/4" 1 1/2" 1/2" -
ELECTRIC WATER
COOLER
ELKAY LVRCHD8S
HB-1 HOSE BIBB
NON-FREEZE USE, BRASS WITH CHROME FINISH, BACKFLOW PREVENTED, ASSE 1052 APPROVED, MALE HOSE THREAD, WHEEL
HANDLE, WITH RECESSED WALL BOX
- - 3/4" - HOSE BIBB WOODFORD MODEL B26 6
FD-1
FLOOR DRAIN
ROUND
CI BODY, ADJUSTABLE STRAINER HEAD, 7" DIAMETER POLISHED NICKEL BRONZE TYPE 'F37' STRAINER, EXTENDED RIM, ASME A112.6.3
2" OR 3" 1 1/2" - - FLOOR DRAIN JAY R. SMITH 2005Y-B-NB -
MARK DESCRIPTION WASTE VENT C.W. H.W.