This statement of work describes requirements for fabricating a watertight hatch for the U.S. Coast Guard. The contractor shall fabricate one 36" x 72" flush watertight hatch meeting Coast Guard Drawing 130-CGB-085-002, Rev , which shall be located in Hold 2-60-A according to Drawing 130-CGB-085-001, Rev 2. The hatch shall be constructed of steel, rated for 15 PSI, include 14 individual dogs, and be hinged on the long side with a trough drain. The related solicitation from the Department of Homeland Security's U.S. Coast Guard, number 70Z08524P709, seeks bids for fabricating this watertight hatch.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Watertight Hatch, FABRICATE
1. SCOPE
1.1 Intent. This work item describes the requirements for the Contractor to FABRICATE water tight hatches identified in Table 1.
Table 1 – Water tight Hatch location
| Description |
| Location |
| Drawing |
| FWT Hatch 1-83-2; 36” x 72” Flush Watertight Hatch |
| E Hold |
2-60-A Coast Guard Drawing 130-CGB-085-002
1.2 Government-furnished property.
| MTI |
| ITEM DESCRIPTION |
| NSN/PN |
| QTY |
| ESTIMATED COST |
($/UNIT)
| N |
| { FWT Hatch 1-83-2; 36” x 72” Flush Watertight Hatch |
| NSN: |
PN:
1 ea.
2. REFERENCES
Coast Guard Drawing 130-CGB-085-001, Rev 2, CGB-13070, General Arrangement - Main Deck Plan Coast Guard Drawing 130-CGB-085-002, Rev , CGB-13070, Compartment & Access – Plan @ Hold, Mn Dk, & Dk Hse
3. REQUIREMENTS
3.1 Fabricate Marine Hatch, NAVSEA Drawing 803-1624113, Steel Constructed, Flush Water-tight, FWTH, 36"x72" , 15 PSI, 14 Individual Dogs, Hinged on Long Side, and Trough Drain