Plans_-_Repair_NDI_Bldg_P-1.pdf
PDF 17 MB Posted
- Attached to
- CES Repair NDI Building P-1 Federal contract opportunity
- Solicitation number
- W91SMC-18-B-7002
About this file
Plans without controlled access due to issues.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_1_Repair_NDI_Building_P-1.pdf | ||
| WD___IL180004_revised_16_Feb_18.docx.pdf | ||
| Plumb_-_FP.PDF | ||
| Site_Visit_06_Mar_18_Sign-In.pdf | ||
| Site_Visit_Minutes_06_Mar_18.pdf | ||
| SBSA_Pre-Bid_Slides_-_Repair_NDI_P-1.pdf | ||
| Project_Manual_-_Repair_NDI.pdf | ||
| W91SMC-18-B-7002_-_Solicitation.pdf | ||
| SOW_-_Repair_NDI_DCFT162012.pdf | ||
| SF_1705.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STORAGE
DN
07091011121314
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADAAG ADA ACCESSIBILITY GUIDELINES
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
BO BOTTOM OF
BOT BOTTOM
BRG BEARING
BS BOTH SIDES
BTWN BETWEEN
CAB CABINET
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CPT CARPET
CTB CERAMIC TILE BASE
CWT CERAMIC WALL TILE
CTR CENTER
DBL DOUBLE
DEG DEGREE
DEMO DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DOOR
DS DOWNSPOUT
DET DETAIL
DWG DRAWING
EA EACH
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (OR) ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FF EL FINISH FLOOR ELEVATION
FG FINISHED GRADE
FLR FLOOR
FLUOR FLUORESCENT
FR FIRE RESISTIVE
FT FOOT (OR) FEET
FURG FURRING
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GDR GUARD RAIL
GEN GENERAL
GL GLASS
GRD GRADE
GYP BD GYPSUM BOARD
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATING, &
AIR CONDITIONING
ID INSIDE DIAMETER
INSUL INSULATE (OR) INSULATION
INT INTERIOR
JAN JANITOR
K NOT USED
LAM LAMINATE
LAV LAVATORY
LIN LINEAR
LOC LOCATION
LTG LIGHTING
LVR LOUVER
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
OFOI OWNER FURNISHED
OWNER INSTALLED
OH OPPOSITE HAND
ORD OVERFLOW ROOF DRAIN
OVHD OVERHEAD
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATED
PT PAINT (INTERIOR)
PVC POLYVINYL CHLORIDE
QTF QUARRY TILE FLOOR
QTB QUARRY TILE BASE
QTY QUANTITY
R RADIUS (OR) RISER
RB RESILIENT BASE
RD ROOF DRAIN
REC RECESSED
REF REFERENCE (OR) REFRIGERATOR
REQD REQUIRED
REV REVISION
RF RESILIENT FLOORING
RM ROOM
RO ROUGH OPENING
SECT SECTION
SF SQUARE FOOT
SHTHG SHEATHING
SIM SIMILAR
SPEC SPECIFICATION(S)
SST STAINLESS STEEL
STC SOUND TRANSMISSION CLASSIFICATION
STD STANDARD
STL STEEL
STRUCT STRUCTURAL (OR) STRUCTURE
T TREAD
T&B TOP AND BOTTOM
TBD TO BE DETERMINED
TD TOWEL DISPENSER
TO TOP OF
TOC TOP OF CONCRETE
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOS TOP OF STEEL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WALL HYDRANT (OR) WATER HEATER
XFMR TRANSFORMER
ARCHITECTURAL ABBREVIATIONS
11.9
11.9
A A
B B
C C
F F
G G
H H
I I
J J
K K
L L
M M
P P
Q Q
R R
AE-401
SHORT TERM
PARTS
STORAGE
JOAP/ADMIN
PENETRANT
INSPECTION
LINE
GROUND FLOOR PLAN
SCALE:1/8"=1'-0"
A401
AE - 101
DRAWING TYPES LEGEND
0- GENERAL INFORMATION
1 - PLANS (HORIZONTAL VIEWS)
2 - ELEVATIONS (VERTICAL VIEWS)
3 - SECTIONS (SECTIONAL VIEWS)
4 - ENLARGED VIEWS (PLANS, ELEVATIONS OR SECTIONS)
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
DISCIPLINE TYPE (ARCHITECTURE SHOWN)
DRAWING TYPE (PLAN, ELEVATION, ETC.)
SERIES/ FLOOR DESIGNATION
DETAIL CALLOUT
ENLARGED PLAN OR DETAIL
ON SHEET INDICATED
A201
INTERIOR ELEVATION CALLOUT
ARROWS INDICATE INTERIOR
ELEVATION ON SHEET
INDICATED
STRUCTURAL GRIDS
AS INDICATED ON DRAWINGS
A
BUILDING SECTION CALLOUT
ARROWS INDICATE BUILDING
SECTION ON SHEET INDICATED
A301
SECTION CALLOUT
ARROW INDICATE WALL SECTION ON
SHEET INDICATED
A302
ROOM NAME
ROOM NAME & NUMBER SYMBOL
REFER TO ROOM FINISH SCHEDULE
101A
DOOR NUMBER SYMBOL
REFER TO DOOR SCHEDULE
DOOR NUMBER WITH *
INDICATES ACCESS CONTROL
HARDWARE
PARTITION TYPE SYMBOL
REFER TO PARTITION TYPES
GLAZING TYPE SYMBOL
REFER TO GLAZING TYPES
A
AL1
REVISION SYMBOL
REFER TO SHEET BORDER FOR
REVISION HISTORY
ELEVATION DATUM SYMBOL
INDICATES DATUM ELEVATION AS INDICATED
Bottom Text Top Text
DISCIPLINE MODIFIER (ELEMENTS SHOWN)
ARCHITECTURAL SYMBOLS LEGEND
DRAWING TITLE
0 4' 8' 16'
1/8" = 1'-0"
NORTH ARROW AND SCALE
A301
N
FLOOR LEVEL
KEYNOTE SYMBOL
INDICATES INFORMATION FOUND IN
KEYNOTES ON PLAN
3 DIGIT ROOM NUMERAL
LOCATED IN THE
BOTTOM RIGHT
SHEET CORNER
0 2' 4' 8'
1/4" = 1'-0"
ROOM NUMBER
GRAPHIC SCALES
EQ5 3/4"EQ
8" CMU BOND BEAM
HOLLOW METAL FRAME -
SEE SCHEDULE
SEALANT BOTH SIDES
HOLLOW METAL
DOOR - SEE
SCHEDULE
4"
REINFORCING
GROUT FILL
DOOR - SEE SCHEDULE
FOR TYPE AND SWING
3/
4"
HOLLOW METAL FRAME -
SEE SCHEDULE
SEALANT BOTH SIDES CMU
3/8" FLAT HEAD
COUNTERSUNK MACHINE
BOLTS AT 24" O.C. VERT
C M
U W
ID
TH
9'-4" A.F.F.
TOP OF CMU
URETHANE SEALANT
AT PERIMETER-RAKE
GROUT JOINT (1/4" DEEP)
FOR INSTALLATION
PT-2 ON ALL FACES
OF THE WASH RACK PT-2 ON ALL FACES
OF THE WASH RACK-
INSIDE AND OUT.
CONCRETE ROOF AT
WASH RACK-PT-2
PT-1
RESINOUS FLOORING -
INTEGRAL COVE BASE
FABRIC CURTAIN WALL
FABRICATED AS CLOSE
TO THE EDGES OF THE
OPENING AS POSSIBLE
A A
EXISTING CMU WALL
TO REMAIN
EXISTING THRESHOLD TO
REMAIN U.O.N.
EXISTING EXTERIOR ENCLOSURE
TO REMAIN UNDESTURBED
NEW 2"X2" LUMBER
TRIM AT PERIMETER
OF BLACKOUT PLYWOOD
- PAINT
.5/8" GYP BD.
PAINT GYP BD. AND TRIM
TO BLACKOUT EXISTING
OPENING.
COUNTERSINK EXPOSED
SCREWS AND FILL WITH
PUTTY - PAINT.
2"X2" HORIZ. LUMBER BATTEN
TRIM AT 2'-6" ABOVE THE EXIST.
THRESHOLD TO COVER HORIZ.
PLYWOOD JOINT.
1/
6"
EXISTING EXTERIOR ENCLOSURE
TO REMAIN UNDESTURBED.
AFF
9'-4"
A-001
FLOOR
SECOND
GYPSUM BOARD
PARTITION
ABOVE THE CMU
PARTITION
(RE: 10/AE-401)
CMU PARTITION
CMU BOND BEAMS
(RE:STRUCTURAL
NOTES)
HEAD CONDITION
(RE:WALL TYPES)
SEE
STRUCTURAL
FOR BRACING)
ALIGN GYPSUM BOARD
FINISH WITH
EXPOSED SIDE OF CMU
PARTITION.
IF BOTH SIDES ARE
EXPOSED
SEALANT
WITH BACKER ROD
BOTH SIDES
SUSPENDED
CEILING EDGE
TRIM ANGLE
CMU PARTITION
(REFER TO
PARTITION TYPES)
INSTALL CONTINUOUS
J-BEAD ON BOTH SIDES LA
YO
U T
DR
AW
N
RE
VI
EW
ED
D0
R
EV
IS
IO
N D
AT
E
H an so n No
Fi le na m e
Sc al e
Da te
3d
W in g Ill in oi s Ai rN at io na lG ua rd Sp rin gf ie ld
,I llin oi s
3-
H an so n
Pr of es si on al
Se rv ic es
In c.
So ut h Si xt h
St re et
Ph on e:
(2
)7
-2
O kl am ho m a
C ity
,O K
8-
N G
B
ID
IQ
C on tra ct
W
L-
-D
Br oa dw ay
Ex te ns io n, Su ite
Ph on e:
(4
)8
-2
C op yr ig ht
H an so n Pr of es si on al
Se rv ic es
In c.
R
EP
AI
R
N D
IB
U
IL
D
IN
G
P-
SP
R
IN
G
FI
EL
D ,I
L
RICHARD S.
JOHNSON
2300L IC E N S E D A R C H IT
E C T
S T
A T E
O F O K LA HO
M A
TYPE B3 (100%) SUBMITTAL - 8/18/2017C
:\U se rs
\jb c\
D oc um en ts \M y R ev it\
0_ Ar ch _j cr on eG C
R S
N .rv t 8/
/2
:0
5 :
A M
/1
8/
A R
CH
IT
EC
TU
RA
L
AB
BR
EV
IA
TI
O
NS
,T
YP
IC
A L
A C
CE
SS
IB
IL
IT
Y
M O
U
NT
IN
G
H
EI
G
HT
S
SY
M
B O
LS
LE
G
EN
D
A-001
JB
C
JB
C
0 1' 2' 4'
1/2" = 1'-0" 0 8' 16' 32'
1/16" = 1'-0"
SCALE: 1/16" = 1'-0"
OVERALL FLOOR PLAN1
SCALE: 1 1/2" = 1'-0"
ARCHITECTURAL SYMBOLS LEGEND
SCALE: 3" = 1'-0"
DETAIL - CMU HEAD3
SCALE: 3" = 1'-0"
DETAIL - CMU JAMB7
SCALE: 1/2" = 1'-0"
INTERIOR ELEVATION RM 1035
SCALE: 1" = 1'-0"
DETAIL-BLACKOUT WINDOW2
SCALE: 1/2" = 1'-0"
DETAIL4
SCALE: 3" = 1'-0"
DETAIL6
3" 9"6"0
3" = 1'-0"
0 6" 1' 2'
1" = 1'-0"
EXISTING MAINTENCE HANGAR AREA - THERE
IS NO WORK IN THIS AREA UNLESS SPECIFICALLY
MENTIONED OF DOCUMENTED IN THE CONSTRUCTION
DOCUMENTS.
N
07091011121314
D O
O R
H E
IG
H
T
DOOR WIDTH
WFI WOOD, INTERIOR
2" 2"DOOR WIDTH
D4 STEEL
D O
O R
H E
IG
H
T 4"
11.9 11 10 9 8 7 6 5 4 3 2 1 17
A A
B B
C C
8' -0
JOAP/ADMIN
1 2
F1
F1
F1
F1
F1
A-001
4 4
RE:4/A-001
9 9
7 7 7
4' -0
'-6
4'-0" 1'-6"
PENETRANT
INSPECTION
LINE
SHORT TERM
PARTS
STORAGE
8'-10"
FIELD
VERIFY
'-4
4'-4"
A-001
10" 4'-6" 6"
5' -6
8 8 8 8 8 8
4'-0" 2'-0"
13 13 13 13
2'-0"
4'-0" 8'-0" 4'-0"
8' -0
AE-401
RE:4/A-001
RE:4/A-001
182' -0
FINISH
FLOOR
DECK
8" CMU
NON-RATED PARTITION AS SHOWNF1
FINISHED FLOOR
BASE AS
SCHEDULED
SEALANT BOTH
SIDES
5/8" GYP BD
(BOTH SIDES)
SLOTTED
DEFL TRACK
SEALANT BOTH
SIDES
5 4 3
A
4"
4" 3'
-4
4" 3'
-8
4"
4" 4'-6" 4" 4'-6" 4" 1'-11 3/4"1'-11 3/4"
4"
4'-6" 4" 4'-6" 4"
AE-401
AE-401
AE-401
AE-401
A-001
AE-4014
31'-4 1/2"
8' -0
32'-0 1/2"
8' -0
EQ
EQ
6" 8"
7' -0
12'-0"4"
1/4" 1" 1/4" 4"
EXTRUDED ALUMINUM
LOUVERS TYP.
ALUM. FB 1/4" X 2 " RIBS TYP.
HINGES
STEEL 4" X 4" X 1/4"
GATE POSTS TYP.
CAPPED
ALUM. L3" X 3" X 1/4"
PANEL FRAME TYP.
FOUR SIDES
3/16" DIA. CABLE BRACING
TYP(AS NEEDED)
EQ. EQ.
ALUM. 2" X4" RECT TUBE
GATE LEAF FRAME TYP.
PAD LOCKABLE SLIDE BOLT
LOCKABLE DROP RODS
ALUM. 1" SQ. SOLID
GUSSTES TYP. (AS
NEEDED)
PLAN
ELEVATION
EQ
EQ
EQ
EQ
V
AR
IE
S
2"
EXTRUDED ALUMINUM
LOUVERS TYP.
ALUM. FB 1/4" X 2 " RIBS TYP.
ALUM. L3" X 3" X 1/4"
PANEL FRAME TYP.
FOUR SIDES
3/16" DIA. CABLE BRACING
TYP.(AS NEEDED)
ALUM. 2" X 4" RECT TUBE
GATE LEAF FRAME TYP.
ALUM. 1" SQ. SOLID GUSSTES
TYP. (AS NEEDED)
1/ 2"
O V
ER
LA
P
TY
P.
3/
8"
TY
P
V
AR
IE
S
10"
11/16" DIA
C L
C L
4"X4"X 1/4"
3/4" PL
7' -0
2"
EXTRUDED ALUMINUM
LOUVERS TYP.
ALUM. FB 1/4" X 2 " RIBS TYP.
ALUM. L3" X 3" X 1/4"
PANEL FRAME TYP.
FOUR SIDES
3/16" DIA. CABLE BRACING
TYP.(AS NEEDED)
ALUM. 2" X 4" RECT TUBE
GATE LEAF FRAME TYP.
ALUM. 1" SQ. SOLID GUSSTES
TYP. (AS NEEDED)
3/
8"
TY
P
1/ 2"
O V
ER
LA
P
TY
P.
ALUM. FB 1/4" X 2 " RIBS TYP.
ALUM. TS 4"X4"X 1/4" POST
TYP. CAP TOP AND GRIND
SMOOTH
2"
7' -0
4" 4"5'-0" MAX
PLAN
ELEVATION
LA
YO
U T
DR
AW
N
RE
VI
EW
ED
D0
R
EV
IS
IO
N D
AT
E
H an so n No
Fi le na m e
Sc al e
Da te
3d
W in g Ill in oi s Ai rN at io na lG ua rd Sp rin gf ie ld
,I llin oi s
3-
H an so n
Pr of es si on al
Se rv ic es
In c.
So ut h Si xt h
St re et
Ph on e:
(2
)7
-2
O kl am ho m a
C ity
,O K
8-
N G
B
ID
IQ
C on tra ct
W
L-
-D
Br oa dw ay
Ex te ns io n, Su ite
Ph on e:
(4
)8
-2
C op yr ig ht
H an so n Pr of es si on al
Se rv ic es
In c.
R
EP
AI
R
N D
IB
U
IL
D
IN
G
P-
SP
R
IN
G
FI
EL
D ,I
L
RICHARD S.
JOHNSON
2300L IC E N S E D A R C H IT
E C T
S T
A T E
O F O K LA HO
M A
TYPE B3 (100%) SUBMITTAL - 8/18/2017C
:\U se rs
\jb c\
D oc um en ts \M y R ev it\
0_ Ar ch _j cr on eG C
R S
N .rv t 8/
/2
:0
5 :
A M
/1
8/
E N
LA
RG
ED
FL
O
O R
PL
A N
AE-401
JB
C
JB
C
DOOR SCHEDULE
MARK
DOOR FRAME
SHEET KEYNOTES HARDWARE SET
SIZE
TYPE
DETAIL
WIDTH HEIGHT THK HEAD JAMB SILL
1 6'-0" 7'-0" 1 3/4" D4 3/A-001 7/A-001 - 2, 3 2 6'-0" 7'-0" 1 3/4" D4 3/A-001 7/A-001 - 2, 3
ROOM FINISH SCHEDULE
ROOM
NUMBER. ROOM NAME FLOOR FINISH
BASE
FINISH
WALL FINISHES
CEILING
FINISH
CEILING
HEIGHT
SHEET
KEYNOT
ES
NOTESNORTH SOUTH EAST WEST
100 JOAP/ADMIN EXIST. TO REMAIN NONE PT-1 PT-1 PT-1 PT-1 EXP.
STRUCTURE
EXP.
STRUCTURE
101 SHORT TERM PARTS
STORAGE
EXIST. TO REMAIN NONE PT-1 PT-1 PT-1 PT-1 EXP.
STRUCTURE
EXP.
STRUCTURE
102 PENETRANT
INSPECTION LINE
EPOXY FLOORING ICB-1 PT-1 PT-1 PT-1 PT-1 EXP.
STRUCTURE
EXP.
STRUCTURE
GENERAL NOTES
SHEET KEYNOTES
SCALE: 1/4" = 1'-0"
DOOR TYPE
SCALE: 1/4" = 1'-0"
FRAME TYPE
SCALE: 1/8" = 1'-0"
ENLARGED FLOOR PLAN1
0 4' 8' 16'
1/8" = 1'-0" N
0 2' 4' 8'
1/4" = 1'-0"
1 PAINT EXISTING WALL TO REMAIN
2 PAINT DOOR FRAME TO MATCH EXISTING
ADJACENT FRAMES
3 PAINT DOOR TO MATCH EXISTING ADJACENT
FRAMES
4 EXISTING DOOR TO REMAIN
5 EXISTING ELEVATOR SHAFT, ELEVATOR AND
EQUIPMENT TO REMAIN UNDESTURBED
6 NEW CMU WASH RACK-PAINT INSIDE, OUTSIDE AND
TOP WITH PT-2 (SECTION 09060-COLOR SCHEDULE)
7 EXISTING WALL TO REMAIN
SCALE: 1 1/2" = 1'-0"
PARTITION TYPES10
8 EXISTING GOVERNMENT FURNISHED EQUIPMENT
TO BE DELIVERED TO THE SPACE BY THE
GOVERNMENT. THE GENERAL CONTRACTOR WILL
BE RESPONSIBLE FOR THE FINAL CONNECTIONS
AND INSTALLATION OF THE EQUIPMENT.
9 OFFICE DESKS - FF&E (GFCI)
10 EYEWASH SUMP PIT WITH FRAME AND GRATE
1. REFER TO SECTION 090690 - COLOR SCHEDULE
FOR MATERIAL COLORS.
11 ALIGN FACE OF GYPSUM BOARD WITH OUTSIDE
FACE OF CHAMFERED COLUMN.
SPECIALTY EQUIPMENT SCHEDULE
NUMBER Description LENGTH DEPTH HEIGHT ITEM # PROVIDED BY
01 ASPEX JEMM MICROSCOPE 6'-0" 3'-0" 6'-0" 01 G.F.C.I.
02 SPECTROIL M/N & SPECTROIL M SPECTROMETERS 9'-0" 3'-0" 6'-0" 01 G.F.C.I.
03 JET SCAN MICROSCOPE 4'-0" 3'-0" 4'-0" 01 G.F.C.I.
04 MAGNE-TECH MAGNETIC PARTICLE MACHINE 10'-6" 4'-6" 7'-0" 04 G.F.C.I.
05 ANTI-STATIC MAT 2 14'-6" 3'-0" 1" 04 G.F.C.I.
06 ANTI-STATIC MAT 1 40'-0" 3'-0" 1" 04 G.F.C.I.
07 U.V. INSPECTION STATION 6'-0" 3'-0" 7'-0" 07 G.F.C.I.
09 POWER DRYER 6'-0" 3'-0" 7'-0" 09 G.F.C.I.
10 ROLLER / CABINET 4'-0" 3'-0" 7'-0" 10 G.F.C.I.
11 U.V. WASH STATION 4'-0" 3'-0" 7'-0" 11 G.F.C.I.
12 E-58D EMULSIFIER 4'-0" 3'-0" 7'-0" 12 G.F.C.I.
13 WASH STATION 4'-0" 3'-0" 3'-0" 13 G.F.C.I.
14 PENETRANT FP-97A 4'-0" 3'-0" 3'-0" 14 G.F.C.I.
15 EMERGENCY EYE WASH / SHOWER UNIT 4'-0" 4'-0" 1'-0 1/4" 15 C.F.C.I.
12 EXISTING CMU WALL INFILL TO REMAIN.
13 BLACKED OUT EXTERIOR OPENING. RE: 2 /A-001
14 CUT EXISTING THRESHOLD BACK FLUSH WITH
THE FACE OF WALL.
15 FABRIC CURTAIN SEE SPEC. 11.13.23
SCALE: 1/4" = 1'-0"
ENLARGED FLOOR PLAN2 SCALE: 3/4" = 1'-0"
GATE3
SCALE: 3/4" = 1'-0"
PANEL SECTION6
SCALE: 1 1/2" = 1'-0"
BASE PLATE DETAIL5
SCALE: 3/4" = 1'-0"
GATE SECTION7
SCALE: 3/4" = 1'-0"
PANEL4
1' 3'2'0
3/4" = 1'-0"
6" 1'-6"1'0
1 1/2" = 1'-0"
16 BLACKEDOUT DOOR WINDOW. RE: 2 /A-001
17 CHANGE DOOR LOCKSET TO BE LOCKABLE FROM
ROOM 102. INSTALL BLANK ROSES ON EXTERIOR
SIDE OF DOOR
18 UTILITY SINK
GENERAL:
G-1 GOVERNING CODE:
2015 INTERNATIONAL BUILDING CODE
G-2 SNOW LOADS: NOT APPLICABLE
G-3 WIND LOADS:
- INTERNAL WIND PRESSURE - 16 PSF
G-4 SEISMIC LOADS:
- RISK CATEGORY = III
- SITE CLASS C
- Ss = 0.203
- S1 = 0.104
- SEISMIC DESIGN CATEGORY - B
- Sds = 0.162
- Sd1 = 0.118
G-5 LIVE LOADS:
- HOIST = 1000 LBS
G-6 DEAD LOADS:
- SELF WEIGHTS OF COMPONENTS
G-7 THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS,
COORDINATES AND EXISTING CONDITIONS PRIOR TO
CONSTRUCTION. NOTIFY THE OWNER'S REPRESENTATIVE OF ANY
DISCREPANCY IMMEDIATELY.
G-8 COORDINATE STRUCTURAL SHEETS WITH ALL OTHER SHEETS
FOR PIPE SIZES AND LOCATIONS, BEAM POCKETS, GRATING
LEDGES, BLOCK OUTS, ELECTRICAL REQUIREMENTS AND ANCHOR
BOLTED ATTACHMENTS.
G-9 STRUCTURAL SYSTEM IS DESIGNED TO WORK AS A
COMPLETED SYSTEM, ANY TEMPORARY SHORING, OR BRACING
NEEDED DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY
OF THE GENERAL CONTRACTOR; CONTRACTOR IS RESPONSIBLE
FOR ADEQUACY OF TEMPORARY SHORING.
G-10 SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND
PLUMBING PLANS FOR ADDITIONAL SLEEVES, INSERTS, ETC.
G-11 ALL SUBTERRANEAN STRUCTURES, UTILITIES, PIPING, ETC.
IN THE AREA OF ALL EXCAVATIONS TO BE LOCATED AND MARKED
BY CONTRACTOR PRIOR TO EARTH REMOVAL WORK. FLAGS OR
PAINT ARE ACCEPTABLE METHODS. CONTRACTOR TO MAINTAIN
MARKERS UNTIL ALL EXCAVATION ACTIVITIES HAVE CEASED.
COORDINATE WITH OWNER.
G-12 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL SITE
SAFETY AND ALL ACCIDENTS WHICH RESULT IN DEATH, PERSONAL
INJURY OR DAMAGE TO PROPERTY ARISING OUT OF OR IN
CONNECTION WITH PERFORMANCE OF THE WORK, WHETHER
ADJACENT TO OR AT THE SITE.
G-13 NO PIPES OR SLEEVES FOR MECHANICAL TRADES SHALL
PASS THROUGH STRUCTURAL MEMBERS WITHOUT APPROVAL OF
THE STRUCTURAL ENGINEER.
G-14 ALL SECTIONS, DETAILS AND NOTES SHOWN ON THE
DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO
SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE SHOWN.
G-15 SHOP DRAWINGS PREPARED BY SUPPLIERS AND
SUBCONTRACTORS SHALL BE REVIEWED BY THE GENERAL
CONTRACTOR PRIOR TO SUBMITTING TO ARCHITECT. STRUCTURAL
ENGINEER'S REVIEW SHALL BE FOR SIZES AND GENERAL
CONFORMANCE WITH INFORMATION GIVEN IN CONSTRUCTION
DOCUMENTS ONLY. NO WORK SHALL BE STARTED WITHOUT SUCH
REVIEW. BASED ON SUCH REVIEWS, ACTIONS WILL BE NOTED FOR
EACH SHOP DRAWING SUBMITTAL AS LISTED BELOW:
- NO EXCEPTIONS TAKEN: FABRICATION, MANUFACTURING OR
CONSTRUCTION MAY PROCEED ON THE BASIS THAT THE SUBMITTAL
IS IN CONFORMANCE WITH THE DESIGN CONCEPT AND THE
CONTRACT DOCUMENTS.
- FURNISH AS CORRECTED: FABRICATION, MANUFACTURING OR
CONSTRUCTION MAY PROCEED AFTER MAKING THE NOTED
CORRECTIONS TO SATISFY COMPLIANCE WITH THE DESIGN
CONCEPT AND/OR THE CONTRACT DOCUMENTS.
- REVISE AND SUBMIT: NO FABRICATION, MANUFACTURING OR
CONSTRUCTION MAY PROCEED. RESUBMIT FOR REVIEW AFTER
REQUESTED REVISIONS ARE MADE.
- SUBMIT SPECIFIED ITEM: NO FABRICATION, MANUFACTURING
OR CONSTRUCTION MAY PROCEED. SUBMIT SPECIFIED ITEM TO
HANSON FOR REVIEW.
- REJECTED: SEE REMARKS NO FABRICATION, MANUFACTURING
OR CONSTRUCTION MAY OCCUR FOR REASONS STATED IN
"REMARKS".
G-16 ALL ASTM DESIGNATIONS SHALL BE THE LATEST UNLESS
NOTED OTHERWISE.
CONCRETE:
C-1 MATERIAL PROPERTIES (U.N.O.)
- COMPRESSIVE STRENGTH - f'c = 4,500 PSI
- CONCRETE REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
C-2 PROTECTIVE COVERING FOR REINFORCEMENT BARS SHALL BE
AS FOLLOWS UNLESS OTHERWISE NOTED ON THE PLANS:
- FOOTINGS:
BOTTOM & SIDES = 3"
TOP = 2"
- WALLS:
EXTERIOR EXPOSURE = 2"
INTERIOR EXPOSURE = 3/4"
- BEAMS / COLUMNS:
OVER TIES OR STIRRUPS = 11/2"
ELEVATED SLABS: = 1"
C-3 ALL REINFORCEMENT BARS SHALL BE FABRICATED IN
ACCORDANCE WITH THE LATEST CRSI MANUAL OF STANDARD
PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES
AND SHALL BE CLEAN AND FREE OF GREASE AND SCALING RUST.
C-4 CONTINUOUS TOP AND BOTTOM BARS, WHEN SHOWN IN
SECTION ONLY, SHALL BE LAPPED AS FOLLOWS: TOP BARS NEAR
MIDSPANS, BOTTOM BARS DIRECTLY OVER SUPPORTS.
C-5 A 3/4" x 3/4" CHAMFER SHALL BE PROVIDED AT THE EDGE OF
ALL FINISHED WALLS, BEAMS AND COLUMNS.
C-6 FOR SLABS ON GRADE, PROVIDE 1/2" THICK PREMOLDED JOINT
FILLER AND SEALANT TO ISOLATE THE SLAB FROM CONTACT WITH
THE STRUCTURES ALONG ITS PERIMETER. AT DEEP FOUNDATIONS,
CAST SLABS TIGHT TO WALLS AND PROVIDE 1/2" x 1/2" FORMED
NOTCH FILLED WITH SEALANT. SEE FOUNDATION DETAILS.
C-7 TWO #5 BARS EACH FACE SHALL BE PROVIDED DIAGONALLY
AT ALL CORNERS OF WALL AND SLAB OPENINGS AND AT ALL
REENTRANT CORNERS OF SLABS. BARS SHALL BE EXTENDED 24"
MINIMUM BEYOND CORNERS OF THE OPENINGS.
C-8 PROVIDE CONTROL OR CONSTRUCTION JOINTS IN SLAB-ON-
GRADE AT 15 FEET MAXIMUM SPACES EACH DIRECTION.
CONTRACTOR SHALL SUBMIT PLANS OF JOINT LOCATIONS FOR
APPROVAL.
C-9 ALL CONTROL JOINTS SHALL BE TOOLED OR SAWN.
C-10 LAP ALL BARS AS FOLLOWS U.N.O. (CLASS B):
#3=1'-7" #4=2'-1" #5=2'-7" #6=3'-1" #7=4'-6" #8=5'-2" #9=5'-10" #10=6'-7" #11=7'-4"
- FOR EPOXY COATED BARS, PROVIDE 1.3 TIMES THE INDICATED
LAP LENGTH.
- FOR TOP BARS, PROVIDE AN ADDITIONAL 1.3 TIMES THE
INDICATED LAP LENGTH.
C-11 HOOK REINFORCEMENT BARS AT DISCONTINUOUS ENDS,
TYPICAL UNLESS OTHERWISE NOTED. EXTEND REINFORCEMENT TO
FAR FACE OF PEDESTALS AND / OR COLUMNS UNLESS NOTED
OTHERWISE.
C-12 PITCH CONCRETE AS REQUIRED TO FLOOR DRAINS 1/4" PER
FOOT UNLESS OTHERWISE NOTED. SEE PLUMBING DRAWINGS.
C-13 ALL INTERIOR SLABS-ON-GRADE TO BE EXPOSED TO VIEW IN
THE FINISHED WORK SHALL RECEIVE A SMOOTH TROWEL FINISH
UNLESS OTHERWISE NOTED. ALL EXTERIOR CONCRETE SURFACES
(E.G. SLABS, STAIRS, RAMPS) SHALL BE ROUGHENED BY
BROOMING IN THE DIRECTION PERPENDICULAR TO THE MAIN
TRAFFIC ROUTE IMMEDIATELY AFTER TROWEL FINISHING IS
COMPLETED.
C-14 COUPLER AND STRUCTURAL CONNECTORS: WHERE
SPECIFIED, PROVIDE COUPLER / CONNECTOR CAPABLE OF
DEVELOPING 125% OF THE YIELD STRENGTH OF THE SPLICED /
CONNECTED BAR. PROVIDE THREADED DOWELS WHERE
REQUIRED.
STRUCTURAL STEEL:
S-1 MATERIAL PROPERTIES (U.N.0.)
- W-SHAPES - Fy = 50 KSI (A992 OR A572 Gr 50)
- HSS - Fy = 46 KSI (A500, Gr. B)
- ANGLES - Fy = 36 KS I(A36)
- PLATES & BAR - Fy = 36 KSI (A36)
- ANCHOR BOLTS - Fy = 36 KSI (ASTM F1554 Gr 36)
S-2 ALL DETAILING, FABRICATION, AND ERECTION OF STRUCTURAL
STEEL MEMBERS SHALL BE IN ACCORDANCE WITH THE AISC - "STEEL
CONSTRUCTION MANUAL", FOURTEENTH EDITION.
S-3 ALL WELDING SHALL BE DONE IN ACCORDANCE WITH THE LATEST
"AWS" SPECIFICATIONS BY CERTIFIED WELDERS. ALL WELDS SHALL
BE MADE WITH E70XX ELECTRODES UNLESS NOTED OTHERWISE.
S-4 CONNECTIONS NOT DETAILED ON THE PLANS SHALL BE
SELECTED IN ACCORDANCE WITH AISC SPECIFICATIONS, TYPE 2
FRAMING CONNECTIONS USING 3/4" DIA. ASTM A325 N-BOLTS (SNUG
TIGHT). UNLESS OTHERWISE NOTED, FOR A GIVEN SIZE AND GRADE
OF BEAMS, CONNECTIONS SHALL BE SELECTED BY THE FABRICATOR
TO SUPPORT THE FOLLOWING BEAM REACTIONS:
R = W/2 > 6 KIPS
W = MAX. TOTAL UNIFORM LOAD (ASD), KIPS, FOR BEAM SPAN IN
FEET PER AISC STEEL CONSTRUCTION MANUAL, THIRTEENTH EDITION,
PART 3, MAXIMUM TOTAL UNIFORM LOAD TABLES (ASD). IN NO CASE
SHALL THE NUMBER OF BOLTS, n, BE LESS THAN THE FOLLOWING FOR
THE INDICATED BEAM CLASS:
n = 2 3 4 5 6 8
W8 W12 W16 W21 W27 W33 W10 W14 W18 W24 W30 W36 C9 C15
S-5 OPENINGS REQUIRED IN STRUCTURAL STEEL MEMBERS SHALL BE
SHOWN ON THE DRAWINGS. FIELD CUTTING OF HOLES IN
STRUCTURAL STEEL MEMBERS SHALL NOT BE ALLOWED WITHOUT
WRITTEN PERMISSION OF THE ENGINEER.
S-6 CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND
DIMENSIONS PRIOR TO STRUCTURAL STEEL FABRICATION.
S-7 THE CONTRACTOR SHALL FURNISH AND INSTALL MISCELLANEOUS
STEEL (CURBS, HANGERS, BRACING, ETC.) AS CALLED FOR OR AS
NECESSARY PER ARCHITECTURAL AND MECHANICAL / ELECTRICAL
DRAWINGS.
S-8 BEAM AND LINTEL BEARING PLATES TO BE FULLY GROUTED WITH
1/2" MINIMUM THICKNESS NON-SHRINK GROUT.
S-9 ANCHOR BOLTS TO BE PROVIDED AT ALL LINTEL AND BEAM
BEARINGS ON MASONRY OR CONCRETE.
S-10 WHENEVER CONSTRUCTION SCHEDULING REQUIRES THE
ERECTION OF STRUCTURAL MEMBERS WHICH BY THEMSELVES
WOULD BE CONSIDERED LATERALLY UNSTABLE, ADEQUATE
TEMPORARY BRACING SHALL BE PROVIDED.
S-11 ALL INTERIOR STEEL TO RECEIVE SHOP PRIMER AND WHITE
TOP COAT TO MATCH EXISTING WHITE CEILINGS. SEE DIVISION 9
SPECIFICATIONS FOR COATING REQUIREMENTS OF INTERIOR STEEL
FRAMING.
S-12: ALL EXTERIOR STEEL FRAMING TO BE HOT DIPPED GALVANIZED
PER ASTM A123.
MASONRY:
M-1 MATERIAL PROPERTIES (U.N.O.)
- COMPRESSIVE STRENGTH - f'm = 1500 PSI
- MASONRY REINFORCEMENT - Fy = 60 KSI (A615 GR 60)
- MORTAR - TYPE S
- GROUT @ 28-DAYS - 2500 PSI (ASTM C476)
M-2 ALL CELLS WITH VERTICAL REINFORCEMENT SHALL BE
GROUTED SOLID.
M-3 ALL LINTEL BEARINGS SHALL BE GROUTED TO THE
FOUNDATION.
M-4 MASONRY UNITS TO BE PLACED IN ONE-HALF RUNNING BOND,
UNLESS OTHERWISE NOTED.
M-5 MASONRY DESIGN BASED ON INSPECTED WORKMANSHIP.
M-6 ALL INTERIOR NON-LOAD BEARING MASONRY PARTITION WALLS
SHALL BE REINFORCED WITH #4 BARS @ 32" O.C. VERTICAL. ALL
CELLS CONTAINING REINFORCEMENT SHALL BE GROUTED SOLID.
LAP BARS 50 BAR DIAMETERS UNLESS NOTED OTHERWISE.
PROVIDE BOND BEAM EVERY 5'-4" OF VERTICAL WALL WITH
REINFORCED WITH 1-#5 BAR. SEE ARCHITECTURAL DRAWINGS FOR
MASONRY SIZES AND LOCATIONS.
M-7 ALL MASONRY WALLS ARE TO HAVE HORIZONTAL, 9 GAUGE
JOINT REINFORCEMENT WHICH DOES NOT EXCEED 16 INCHES ON
CENTER VERTICALLY.
M-8 ALL LAPS SHALL BE 50 BAR DIAMETERS U.N.O.
M-9 HOLLOW MASONRY UNITS SHALL BE LAID WITH FULL HEAD
JOINTS AND FULL BED JOINTS OF THE FACE SHELLS AND UNDER
WEBS WHERE THE ADJACENT CELLS ARE TO BE FILLED WITH
GROUT AND AT THE BOTTOM COURSE.
GENERAL STRUCTURAL NOTES
MISC. STEEL LINTEL SCHEDULE FOR
NON-STRUCTURAL WALLS
WALL
THICKNESS
OPENING WIDTH
SHAPE
4" 1 ANGLE 3 1/2x3 1/2x5/16
0'-0" TO 6'-0"
1 ANGLE 6x3 1/2x5/16
6'-1" TO 8'-0"
6" 2 ANGLE 3 1/2x2 1/2x5/16 1 ANGLE 5x3x5/16
1 ANGLE 3 1/2x3 1/2x5/16
8" 2 ANGLES 3 1/2x3 1/2x5/16 2 ANGLES 6x3 1/2x5/16
10" 2 ANGLES 4x4x5/16 2 ANGLES 6x4x5/16
12" 3 ANGLES 3 1/2x3 1/2x5/16 3 ANGLES 6x3 1/2x5/16
NEW DUCTWORK, SEE MECHANICAL
EXISTING CMU WALL
INSTALL L3 1/2x3 1/2x5/16 WITHIN JOINT ON
EITHER SIDE OF WALL WITH 8" OF BEARING
ON EACH SIDE OF DUCT PENETRATION
PRIOR TO REMOVING CMU BELOW
REMOVED CMU FOR NEW
DUCT PENETRATION
LA
Y O U T
D R
AW
N
R E V
IE
W E D
D sheetsof XX
R E
V
IS
IO
N
D A
T E
H a n so n
N o
F ile n a m e
S c a le
D a te rd
W in g
Il lin o is
A ir N a ti o n a l G u a rd
S p ri n g fi e ld
Il lin o is
-2
H a n s o n P ro fe s s io n a l S e rv ic e s I n c
S o u th
S ix th S tr e e t
P h o n e
(2
-2
O k la m h o m a C it y O
K
-7
N G
B I D
IQ
C o n tr a c t
W
L
-1 -D
B ro a d w a y E x te n s io n S u it e
P h o n e
(4
-2
C o p yr ig h t H a n so n
P ro fe ss io n a l S e rv ic e s In c
R E
P A
IR
N
D I B
U
IL
D
IN
G P
-1
S P
R
IN
G F
IE
L D
IL
I:
\1 jo b s \1
D
\C
A D
\S tr u c t\ M o d e l\ R
S P
S tr u c tu re v . r v t
/1
/2
: 3 :2
P
M
/1
/2
S T
R U
C T
U R
A L
G E
N E
R A
L N
O T
E S
S-001
R M
F
T R
G
TYPE B-3 (100%) SUBMITTAL - 08/18/2017
R M
F
1 1/2" = 1'-0"1
TYPICAL EXISTING WALL LINTEL
0 1' 2'
/1
/2
/1
/2
/1
/2
A
B
C
F
123456789101111.9 17 16 15
EXISTING 4"
SANITARY SEWER
S-101
S-101
SIM
S-101
SIM
S-101
NEW UTILITIES, SEE
PLUMBING
S-101
S-101
S-101
S-101
SIM
SLAB CUTS
FOR UTILITIES
S-102
1 ________ S-102
9'-4"
S-103
SEE ARCH FOR
SUMP LOCATION
FULLY GROUT 4'-8"
WIDE SECTION OF
CMU AT WALL
MOUNTED SINK
#4@32" VERT. MASONRY
REINFORCEMENT, DRILLED AND
EPOXY GROUTED INTO SLAB
WITH 3" MINIMUM EMBEDMENT
8" CMU PARTITION WALL
EXISTING 5" +/- SLAB ON GRADE
FIRST FLOOR
EL. 100'-0" +/-
TOP OF CMU PARTITION
9'-4" AFF
SECOND FLOOR
EL. 112'-6" +/-
L3x3x1/4 KICKER AT 5'-0" MAX SPACING
ALONG LENGTH OF WALL, KICKERS TO
BE WITHIN ROOMS #100 AND #102,
COORDINATE LOCATION OF KICKERS
WITH NEW AND EXISTING DUCTWORK WT8x33.5 WITH (2)-5/8" DIA.
F1554 ANCHOR BOLTS, 1 ON
EITHER SIDE OF WEB,
CENTERED IN THE BOND BEAM,
WITH 4" MINIMUM EMBEDMENT
BOND BEAM WITH 1-#5 BAR
1/4
TYP.
L3x3x1/4x7" LONG WITH (2)-5/8" DIA.
CONCRETE SCREW ANCHORS (POWERS
WEDGE BOLT OR EQUIVALENT) WITH 3
1/4" MINIMUM EMBEDMENT
STUD WALL, SEE ARCH
NEW UTILITY, SEE
PLUMBING DRAWINGS
PIPE BEDDING
COMPACTED DRAINAGE
COURSE MATERIAL (IDOT CA-7)
MATCH EXISTING, 4" MIN.
NEATLY CUT EXISTING 5"+/- SLAB
FOR NEW UTILITIES AND PATCH
SLAB TO BE FLUSH WITH
EXISTING
FIRST FLOOR
EL. 100'-0"+/-
#4@12" CONT.
#4@12" DRILLED AND EPOXY
GROUTED INTO EXISTING
SLAB WITH 4" MINIMUM
EMBEDMENT, BAR TO EXTEND
TO WITHIN 4" OF FAR END OF
SLAB CUT, STAGGER DOWELS
EA. SIDE OF TRENCH
EXISTING 5" +/- SLAB
REPLACEMENT REMOVAL
LIMITS OF SLAB REMOVAL AND
EXCAVATION FOR NEW
UNDERSLAB PLUMBING WORK
COMPACTED ENGINEERED
FILL AS REQUIRED
10 MIL POLYETHYLENE
VAPOR BARRIER
1/4" FORMED JOINT
AND SEALANT
NEATLY SAW CUT EXISTING
5"+/- SLAB FOR NEW WASH BAY
#4@32" MASONRY DOWELS WITH
90 DEG. HOOK INTO NEW SLAB
#4@12", EW
NEW 5" SLAB, SEE
ARCH FOR SLAB PITCH
#4@12" DOWELS DRILLED AND EPOXY
GROUTED INTO CENTER OF EXISTING
SLAB WITH 6" MINIMUM EMBEDMENT,
LAPPED TO NEW SLAB REINFORCEMENT
FLOOR DRAIN PIPING,
SEE PLUMBING6" GRANULAR BACKFILL
8" CMU WALL
BOND BEAM AT TOP OF
WALL WITH 1-#5 BAR
TOP OF WALL
9'-4" AFF
FLAT SLAB
9"
CONTINUOUS SEALANT AT
BASE OF CMU
#4@12" EW
#5 DOWEL @ 32"
CORRESPONDING TO
REINFORCED CELLS WITH
90 DEG HOOK INTO SLAB
6" CONC. SLAB
EXISTING FLOOR BEAMS
C L R
SLEEVE AND SEALANT FOR
LIGHT FIXTURE, SEE ELEC.
3-3" SLEEVES AND SEALANT FOR
PLUMBING VENTS, REFER TO P-102
NEATLY SAW CUT AND
REMOVE EXISTING 5" +/- SLAB
FOR NEW SHOWER SUMP
1 1/2" PULTRUDED
FIBERGLASS GRATING
L1 1/2x1 1/2x1/4 EMBED
FOR GRATING SILL
#4@12" DOWELS DRILLED AND EPOXY
GROUTED INTO CENTER OF EXISTING SLAB
WITH 4" MINIMUM EMBEDMENT, HOOKED TO
LAP NEW REINFORCEMENT
#4@12", EW
6"
FLOOR DRAIN, SEE
PLUMBING, PITCH
SLAB TO DRAIN
6" COMPACTED DRAINAGE
COURSE (IDOT CA-7)
EMERGENCY EYE
WASH, SEE PLUMB
EMERGENCY
SHOWER, SEE
PLUMBING
S-101
4'-0" SQUARE
(2) L3 1/2x3 1/2x5/16
LINTEL ANGLES
DOOR FRAME, SEE ARCH
1/4 1@6
1-#5 BAR
CENTERED IN
SLAB (TYP.)
(T
YP.)
2' -0
" M
IN
O R
L
AR
G
ER
O
PEN
IN
G
(T
YP.)
3" C
L.
EL. SEE ARCH.
2-#4 BARS FULL HEIGHT
24" MIN.
2-#4 BARS IN BOND
BEAM AT SILL (TYPICAL
ALL OPENINGS)
8" BRG.
LINTEL ANGLES
1/4" FORMED JOINT
AND SEALANT
2"4"
L2x2x3/16 CONT.
AROUND SUMP WITH
3/8" DIA.x3" SHEAR
CONNECTOR SPACED
AT 12" O.C. (GALV.)
6"
SHIM GRATING AS
REQUIRED TO MATCH
EXISTING SLAB SURFACE
EXISTING 5"+/- SLAB
#4@12" DOWELS DRILLED
AND EPOXY GROUTED INTO
CENTER OF EXISTING SLAB
WITH 4" MINIMUM
EMBEDMENT, HOOKED TO
LAP NEW REINFORCEMENT
LA
Y O U T
D R
AW
N
R E V
IE
W E D
D sheetsof XX
R E
V
IS
IO
N
D A
T E
H a n so n
N o
F ile n a m e
S c a le
D a te rd
W in g
Il lin o is
A ir N a ti o n a l G u a rd
S p ri n g fi e ld
Il lin o is
-2
H a n s o n P ro fe s s io n a l S e rv ic e s I n c
S o u th
S ix th S tr e e t
P h o n e
(2
-2
O k la m h o m a C it y O
K
-7
N G
B I D
IQ
C o n tr a c t
W
L
-1 -D
B ro a d w a y E x te n s io n S u it e
P h o n e
(4
-2
C o p yr ig h t H a n so n
P ro fe ss io n a l S e rv ic e s In c
R E
P A
IR
N
D I B
U
IL
D
IN
G P
-1
S P
R
IN
G F
IE
L D
IL
I:
\1 jo b s \1
D
\C
A D
\S tr u c t\ M o d e l\ R
S P
S tr u c tu re v . r v t
/1
/2
: 3 :2
P
M
/1
/2
F
IR
S T
F L
O O
R P
L A
N
S-101
R M
F
T R
G
TYPE B-3 (100%) SUBMITTAL - 08/18/2017
R M
F
1/8" = 1'-0"1
FIRST FLOOR PLAN
1" = 1'-0"2
TYPICAL PARTITION WALL SECTION
1 1/2" = 1'-0"3
TYPICAL SLAB CUT SECTION
3/4" = 1'-0"5
WASH BAY SLAB
3/4" = 1'-0"4
EMERGENCY SHOWER SUMP
N 4'0 8' 16'
0 6" 1' 2' 0 1' 2' 3'
0 1' 2' 3'
0 1' 2' 3'
1" = 1'-0"7
TYPICAL DOOR LINTEL
1" = 1'-0"8
TYPICAL FLOOR SLAB OPENING
1" = 1'-0"6
TYPICAL INTERIOR MASONRY LINTEL BEARING
0 6" 1' 2' 0 6" 1' 2'
0 6" 1' 2'
1 1/2" = 1'-0"9
DETAIL
0 1' 2'
SEE ARCH DRAWINGS FOR
NEW WALL LOCATIONS
/1
/2
/1
/2
/1
/2
C
S-102
1'-0" 1'-0"
CENTERLINE OF MONORAIL (1000 LBS. CAPACITY)
CENTERLINE OF PENETRANT LINE
HOOK COVERAGE
AREA
39'-8 3/8" +/-
2'-8 3/8" +/-
1'-1 5/8" +/-
S-102
PART PICK-UP
AREA
C
S-102
W8X15 W8X15 W8X15 W8X15 W8X15 W8X15
S-102
C
R
IG
G
IN
G
P A
R T
/4
CENTERLINE OF
PENETRANT LINE
S-102
5'-6"
1'-3"
FIRST FLOOR
EL. 100'-0" +/-
S-102
SECOND FLOOR
EL. 112'-6" +/-
H O
IS
T
M O
N O
R A
IL
A
N D
C O
N N
/4
C A
B
IN
E T
GFGI
CFCI
S-102
EXISTING
CONCRETE FRAME
PENETRANT LINE
EQUIPMENT (GFGI)
EXISTING CONCRETE
FLOOR BEAM
1000 LBS. HOIST,
SEE SPEC 14510
1000 LBS.
MONORAIL, SEE
SPEC 14510
S-102
SECOND FLOOR
EL. 112-6' +/-
FIRST FLOOR
EL. 100'-0" +/-
C L E
A R
E Q
U
IP
M E
N T
L O
C A
T E
C A
B L E
T O
FLEXIBLE HOIST
FESTOON CABLE
SECOND FLOOR
112'-6" +/-
S-102
L6x4x5/16x13" LONG EA. SIDE OF WIDE FLANGE
WITH (2) 1/2" DIA. CONCRETE SCREW
ANCHORS, POWERS SCREW BOLT PLUS OR
EQUIVALENT, 3 1/2" LONG IN STD HOLES
WIDE FLANGE RAIL SUPPORT WITH (2)
5/8" DIA. A325 SC BOLTS IN OVERSIZED
HOLES, SEE PLAN FOR LOCATION
MONORAIL TRACK
PARALLEL FLUSH-MOUNTED
HANGER BY MONORAIL
MANUFACTURER
CONCRETE FRAME
CONCRETE BEAM (BEYOND)
HOIST
APPROX. LOCATION OF BEAM
REINFORCEMENT, DO NOT CUT
APPROX. LOCATION OF FRAME
REINFORCEMENT, DO NOT CUT
/2
/2
/2
/2
/2
/2
1" 3" 2"
PREFERRED ANCHOR LOCATION
ALTERNATE ANCHOR LOCATION
L6x4x5/16x13" LONG EA. SIDE OF WIDE FLANGE WITH (2)
1/2" DIA. CONCRETE SCREW ANCHORS, POWERS SCREW
BOLT PLUS OR EQUIVALENT, 3 1/2" LONG IN STD HOLES
PARALLEL FLUSH-MOUNTED
HANGER BY MONORAIL
MANUFACTURER
MONORAIL TRACK
WIDE FLANGE RAIL SUPPORT, SEE
PLAN, COPE BEAM END TO CLEAR
ANGLE HANGERS
SECOND FLOOR
EL. 112'-6" +/-
EXISTING
CONCRETE FRAME
1/2" CLR.
HOIST
/2
/2
/2
/2
/2
B
E A
M
F
R A
M E
(2) 5/8" DIA. A325 SC
BOLTS IN OVERSIZED
HOLES
SECOND FLOOR
EL. 112'-6" +/-
L4x4x5/16x4" LONG EA. SIDE OF
WIDE FLANGE WITH (1) 1/2" DIA.
MASONRY SCREW ANCHOR 3"
EMBEDMENT IN STD HOLES
EXISTING CMU WALL
EXISTING CONCRETE FRAME
TYPICAL CONNECTION,
SEE DETAILS
WIDE FLANGE RAIL SUPPORT,
SEE PLAN, COPE BEAM END
TO CLEAR ANGLE HANGERSEND STOP BY HOIST
MANUFACTURER
LA
Y O U T
D R
AW
N
R E V
IE
W E D
D sheetsof XX
R E
V
IS
IO
N
D A
T E
H a n so n
N o
F ile n a m e
S c a le
D a te rd
W in g
Il lin o is
A ir N a ti o n a l G u a rd
S p ri n g fi e ld
Il lin o is
-2
H a n s o n P ro fe s s io n a l S e rv ic e s I n c
S o u th
S ix th S tr e e t
P h o n e
(2
-2
O k la m h o m a C it y O
K
-7
N G
B I D
IQ
C o n tr a c t
W
L
-1 -D
B ro a d w a y E x te n s io n S u it e
P h o n e
(4
-2
C o p yr ig h t H a n so n
P ro fe ss io n a l S e rv ic e s In c
R E
P A
IR
N
D I B
U
IL
D
IN
G P
-1
S P
R
IN
G F
IE
L D
IL
I:
\1 jo b s \1
D
\C
A D
\S tr u c t\ M o d e l\ R
S P
S tr u c tu re v . r v t
/1
/2
: 3 :2
P
M
/1
/2
H O
IS
T
P L
A N
S A
N D
D E
T A
IL
S
S-102
R M
F
T R
G
TYPE B-3 (100%) SUBMITTAL - 08/18/2017
R M
F
1/4" = 1'-0"1
ENLARGED MONORAIL PLAN
1/4" = 1'-0"2
ENLARGED MONORAIL SUPPORT PLAN
1/2" = 1'-0"4
HOIST SECTION
1/4" = 1'-0"3
HOIST ELEVATION
1 1/2" = 1'-0"5
DETAIL
1 1/2" = 1'-0"6
DETAIL
N N 0 2' 4' 8' 0 2' 4' 8'
0 2' 4' 8'
0 1' 2' 4'
0 1' 2' 0 1' 2'
1 1/2" = 1'-0"7
EAST END MONORAIL ATTACHMENT
MAXIMUM HOIST LOAD = 1000 LBS.
0 1' 2'
/1
/2
/1
/2
/1
/2
A A
16'-6" 16'-6"
33'-0"
S-103
S-103
W6x12 (GALV.)
W6x12 (GALV.)
W6x12 (GALV.)
W6x12 (GALV.)
EXISTING SIDEWALK TO REMAIN
REMOVE AND SALVAGE DECORATIVE GRAVEL BETWEEN BUILDING AND
EXISTING SIDEWALK PRIOR TO INSTALLING MECHANICAL PAD. INSTALL
NEW LANDSCAPE FABRIC AND REPLACE SALVAGED DECORATIVE
GRAVEL ON EACH SIDE OF NEW PAD.
EXISTING STORM SEWER TO
REMAIN, TYP. DO NOT DISTURB
SEE NOTE 1
S E
E N
O T
E
NOTES:
1. SEE MECHANICAL DRAWINGS FOR LIMITS OF UNITS.
LOCATE STEEL FRAMING TO BE FLUSH TO OUTSIDE EDGE OF
MECHANICAL UNITS AS INDICATED.
EQ. EQ. EQ. EQ.
1' DEEP SAWN CONTROL
JOINT, TYP.
EXISTING SIDEWALK
TO REMAIN
1" COMPRESSIBLE JOINT
FILLER AND SEALANT
1'-0"
COARSE AGGREGATE
DRAINAGE MATERIAL,
IDOT CA 7
#4@12" EW
C L R
4 OZ NON-WOVEN
GEOTEXTILE FABRIC
PITCH TO DRAIN
LOUVERED SCREENWALL AND
GATE, REFTER TO ARCH
#4@12" L-BAR
1'-6"
6"
MECHANICAL UNIT
W6x12 (GALV.)
HSS5x3x1/4 (GALV.)
1/4
5"
BASE PL1/2"x10"x8" (GALV.) WITH (4) 5/8" DIA.
CONCRETE SCREW ANCHORS, POWERS
SCREW BOLT PLUS MECHANICALLY GALV.
OR EQUIVALENT, 4 3/8" LONG IN STD HOLES
LOCATE STEEL FRAMING TO BE
FLUSH WITH LIMIT OF MECH UNIT
1" NON-SHRINK GROUT BED
LA
Y O U T
D R
AW
N
R E V
IE
W E D
D sheetsof XX
R E
V
IS
IO
N
D A
T E
H a n so n
N o
F ile n a m e
S c a le
D a te rd
W in g
Il lin o is
A ir N a ti o n a l G u a rd
S p ri n g fi e ld
Il lin o is
-2
H a n s o n P ro fe s s io n a l S e rv ic e s I n c
S o u th
S ix th S tr e e t
P h o n e
(2
-2
O k la m h o m a C it y O
K
-7
N G
B I D
IQ
C o n tr a c t
W
L
-1 -D
B ro a d w a y E x te n s io n S u it e
P h o n e
(4
-2
C o p yr ig h t H a n so n
P ro fe ss io n a l S e rv ic e s In c
R E
P A
IR
N
D I B
U
IL
D
IN
G P
-1
S P
R
IN
G F
IE
L D
IL
I:
\1 jo b s \1
D
\C
A D
\S tr u c t\ M o d e l\ R
S P
S tr u c tu re v . r v t
/1
/2
: 3 :2
P
M
/1
/2
M E
C H
A N
IC
A
L P
A D
P L
A N
A N
D D
E T
A
IL
S
S-103
R M
F
T R
G
TYPE B-3 (100%) SUBMITTAL - 08/18/2017
R M
F
1/2" = 1'-0"1
MECHANICAL PAD FOUNDATION PLAN
3/4" = 1'-0"3
TYPICAL FOUNDATION SLAB EDGE
0 1' 2' 4'
0 1' 2' 3'
N
1 1/2" = 1'-0"2
TYPICAL MECHANICAL UNIT SUPPORT
0 1' 2'
/1
/2
/1
/2
/1
/2
R E
V I S
I O
N D
A T
E
S p r i n g f i e l d
I l l i n o i s
H a n s o n
P r o f e s s i o n a l
S e r v i c e s
I n c
S o u t h
S i x t h
S t r e e t
P h o n e d
W i n g
I l l i n o i s
A i r
N a t i o n a l
G u a r d
O k l a h o m a
C i t y
O
K
N G
B
I D
I Q o n t r a c t
W
L
D
B r o a d w a y
E x t e n s i o n
S u i t e
P h o n e
R E
P A
R
D I
B
U I L D
I N
G
P
S P
R I N
G F
I E
L D
I L
TYPE B3 (100%) SUBMITTAL - 8/18/2017
P-101
SCALE:1/8" = 1'-0"
FIRST FLOOR WASTE & VENT PIPING NEW WORK PLAN
SCALE:1/8" = 1'-0"
SECOND FLOOR WASTE & VENT PIPING NEW WORK PLAN
F I R
S T
E C
O N
D
F
L O
O
W
A S
V E
P
P
I N
G
N
R
K
P
L A
N
0 4' 8' 16'
0 4' 8' 16'
AutoCAD SHX Text
JOAP/ADMIN
AutoCAD SHX Text
AutoCAD SHX Text
PENETRANT INSPECTION LINE
AutoCAD SHX Text
AutoCAD SHX Text
SHORT TERM PARTS STORAGE
AutoCAD SHX Text 4"
AutoCAD SHX Text
ST
AutoCAD SHX Text
SAN
AutoCAD SHX Text
SAN
AutoCAD SHX Text 4"
AutoCAD SHX Text
ST
AutoCAD SHX Text
FCO-1
AutoCAD SHX Text
FD-1
AutoCAD SHX Text
TD-1(TYP. OF 3)
AutoCAD SHX Text
FD-1
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
2" VENT DOWN TO BELOW FLOOR
AutoCAD SHX Text
2" VENT DOWN TO BELOW FLOOR
AutoCAD SHX Text
2" VENT DOWN TO BELOW FLOOR
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text
NEW TO EXISTING CONNECTION (TYPICAL)
AutoCAD SHX Text
TD-1 (TYP. OF 4)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3" V
AutoCAD SHX Text 3" V
AutoCAD SHX Text 3" V
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-1
AutoCAD SHX Text 4"
AutoCAD SHX Text 3" V
AutoCAD SHX Text 3"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2" V
AutoCAD SHX Text
AutoCAD SHX Text
3" PLUMBING VENT UP FROM FIRST FLOOR. FLOOR PENETRATION SHALL BE FIRE SEALED.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S LATRINE
AutoCAD SHX Text
AutoCAD SHX Text
CIRF NCOIC/
AutoCAD SHX Text
FIRST SERGEANT
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING 3" PLUMBING VENT
AutoCAD SHX Text
EXISTING BLOCK WALL TO ROOF DECK
AutoCAD SHX Text
EXISTING 4" PLUMBING VENT THROUGH ROOF
AutoCAD SHX Text Hanson No.
AutoCAD SHX Text Filename
AutoCAD SHX Text Scale
AutoCAD SHX Text
LAYOUT
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text Date
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text 13D0027001
AutoCAD SHX Text
E-401.DWG
AutoCAD SHX Text
JPD
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text EXISTING SANITARY WASTE AND STORM PIPING ILLUSTRATED BY THE LIGHT COLORED LINES SHALL REMAIN FOR CONTINUED USE (TYPICAL). PLUMBING VENT SHALL BE INSTALLED UP TO THE SECOND FLOOR. REFER TO THE "SECOND FLOOR WASTE AND VENT NEW WORK PLAN" ON THIS SHEET FOR CONTINUATION OF THE PLUMBING VENT. COORDINATE ROUTING OF PLUMBING VENT (INSTALLED ON FIRST FLOOR) WITH VENTILATION CONTRACTOR AND NEW DUCTWORK SHOWN ON VENTILATION SHEET V-102. TYPE "L" COPPER PIPE (APPROX. 1 1/4" DIAMETER) SHALL CONNECT TO THE THREADED STEEL COUPLING DRAIN OUTLET LOCATED ON THE BOTTOM OF THE EXISTING FOUR FLOOR MOUNTED TANKS AND SHALL INDIRECTLY DISCHARGE INTO TRENCH DRAIN "TD-1" AS SHOWN (EXISTING TANKS WILL BE RELOCATED FROM BUILDING P17 TO BUILDING P1 BY OTHERS). HOLES (SLIGHTLY LARGER THAN THE DIAMETER OF EACH INDIRECT WASTE PIPE) SHALL BE CUT INTO THE TRENCH DRAIN GRATES TO ACCOMMODATE THE INDIRECT WASTE DISCHARGE FROM EACH TANK. A BALL VALVE SHALL BE INSTALLED IN THE INDIRECT WASTE PIPE OF TWO OF THE EXISTING TANKS AS SHOWN. FLOOR DRAIN "FD-1" SHALL BE INSTALLED IN THE LOCATION SHOWN TO SERVE THE NEW EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE. TOP ELEVATION OF FLOOR DRAIN SHALL BE INSTALLED FLUSH WITH THE ELEVATION OF THE DEPRESSED CONCRETE FLOOR SLAB THAT WILL BE POURED IN THE AREA DEPICTED BY THE LIGHT-COLORED BOX (REFER TO STRUCTURAL DRAWINGS FOR ELEVATION OF DEPRESSED FLOOR SLAB). DEPRESSED FLOOR SLAB (USED TO MINIMIZE RUNOFF OF WASTE WATER GENERATED BY THE EMERGENCY FIXTURE) WILL BE COVERED WITH GRATING. PROCUREMENT AND INSTALLATION OF GRATING IS EXCLUDED FROM THE PLUMBING CONTRACTOR'S SCOPE OF WORK. ACCORDING TO THE EXISTING BUILDING CONSTRUCTION DOCUMENTS, THE EXISTING SANITARY WASTE PIPING IN THIS LOCATION HAS AN INVERT ELEVATION THAT IS AT LEAST 3'-6" BELOW THE FINISHED FLOOR ELEVATION. COORDINATE INSTALLATION OF PLUMBING VENT PIPING WITH NEW HOIST BEAM. REFER TO THE STRUCTURAL NEW WORK DRAWINGS FOR COORDINATION PURPOSES. OR COORDINATION PURPOSES. REFER TO THE "SPECIALTY EQUIPMENT SCHEDULE" ON ARCHITECTURAL DRAWING AE-401 FOR A DESCRIPTION OF THE EQUIPMENT ASSOCIATED WITH THE EQUIPMENT TAG NUMBER (TYPICAL).
AutoCAD SHX Text
PLUMBING KEYED NOTES - SANITARY WASTE AND VENT PIPING NEW WORK:
AutoCAD SHX Text
AutoCAD SHX Text PLUMBING VENT SHALL BE INSTALLED ABOVE THE LAY-IN ACOUSTICAL TILE CEILING OF OFFICE 221 AND MEN'S SHOWER 223. PLUMBING VENT SHALL BE ROUTED UP INTO THE CEILING CAVITY ABOVE OFFICE 221 WITHOUT HAVING TO CUT THE WALL MOUNTED EDGE TRIM SUPPORTING THE ACOUSTICAL TILE CEILING. A HOLE SHALL BE CUT INTO THE ACOUSTICAL TILE CEILING TO ACCOMMODATE INSTALLATION OF THE PLUMBING VENT. PLUMBING VENT SHALL CONNECT TO EXISTING PLUMBING VENT SYSTEM LOCATED ABOVE MEN'S SHOWER 223. RELOCATION OF OFFICE FURNITURE IN OFFICE 221 TO ACCOMMODATE INSTALLATION OF THE PLUMBING VENT SHALL BE THE RESPONSIBILITY OF THE CONTRACTING OFFICER.
AutoCAD SHX Text
PLUMBING KEYED NOTES - SANITARY WASTE AND VENT PIPING NEW WORK:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW PLUMBING VENT PIPING SHALL BE PAINTED TO MATCH THE COLOR OF THE SHALL BE PAINTED TO MATCH THE COLOR OF THE ADJACENT WALL AND CEILING SURFACES. PAINTING OF THE PLUMBING VENT PIPING IS INCLUDED IN THE GENERAL CONTRACTOR'S SCOPE OF WORK. HANGERS/SUPPORTS AND ASSOCIATED ATTACHMENT HARDWARE SHALL NOT BE ANCHORED INTO THE BUILDING'S CONCRETE STRUCTURAL BEAMS AND COLUMNS. HANGERS/SUPPORTS AND ASSOCIATED ATTACHMENT HARDWARE MAY BE ANCHORED INTO THE CMU WALLS AND CONCRETE CEILING.
AutoCAD SHX Text
PLUMBING GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text
AutoCAD SHX Text 2.
AutoCAD SHX Text 1/8" = 1'-0"
R E
V I S
I O
N D
A T
E
S p r i n g f i e l d
I l l i n o i s
H a n s o n
P r o f e s s i o n a l
S e r v i c e s
I n c
S o u t h
S i x t h
S t r e e t
P h o n e d
W i n g
I l l i n o i s
A i r
N a t i o n a l
G u a r d
O k l a h o m a
C i t y
O
K
N G
B
I D n t r a c t
W
L
D
B r o a d w a y
E x t e n s i o n
S u i t e
P h o n e
R E
P A
I
B
U I L D
I N
G
P
S P
R I N
G F
I E
L D
I L
TYPE B3 (100%) SUBMITTAL - 8/18/2017
P-102
SCALE:1/8" = 1'-0"
FIRST FLOOR DOMESTIC WATER PIPING NEW WORK PLAN
F I R
F
L O
M
E S
T
A T
E R
P I P
I N
G
N
R
K
P
L A
N
0 4' 8' 16'
AutoCAD SHX Text
JOAP/ADMIN
AutoCAD SHX Text
AutoCAD SHX Text
PENETRANT INSPECTION LINE
AutoCAD SHX Text
AutoCAD SHX Text
SHORT TERM PARTS STORAGE
AutoCAD SHX Text EXISTING DOMESTIC WATER PIPING ILLUSTRATED BY THE LIGHT COLORED LINES SHALL REMAIN FOR CONTINUED USE (TYPICAL). EXISTING PIPING IS INSTALLED APPROXIMATELY 10'-0" ABOVE THE FINISHED FLOOR ELEVATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BACKFLOW PREVENTER "BFP-1"
AutoCAD SHX Text
BACKFLOW PREVENTER "BFP-2"
AutoCAD SHX Text 1 1/4"
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE "ESEFW-1"
AutoCAD SHX Text
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text 1-1/4"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 1 1/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INSTALL 1/2" ISOLATION VALVES IN SUPPLY PIPING DROPS TO SINK "S-1"
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text REMOVE AND DISPOSE OF ABANDONED 3/4" (ESTIMATED SIZE) DOMESTIC WATER PIPING. BRANCH PIPING SHALL BE CAPPED AT MAINS AS SHOWN.
AutoCAD SHX Text Hanson No.
AutoCAD SHX Text Filename
AutoCAD SHX Text Scale
AutoCAD SHX Text
LAYOUT
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text Date
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text 13D0027001
AutoCAD SHX Text
E-401.DWG
AutoCAD SHX Text
JPD
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text COORDINATE THE INSTALLATION LOCATION OF NEW BACKFLOW PREVENTERS "BFP-1" & "BFP-2" WITH EXISTING SANITARY AND STORM PIPING THAT ARE TO REMAIN. COORDINATE THE INSTALLATION LOCATION OF NEW BACKFLOW PREVENTERS "BFP-1" & "BFP-2" WITH NEW COMPRESSED AIR PIPING. REFER TO PLUMBING SHEET P-103 FOR ADDITIONAL INFORMATION PERTAINING TO THE INSTALLATION OF THE NEW COMPRESSED AIR PIPING. AIR GAP FITTINGS CONNECTED TO THE RELIEF VALVE ASSEMBLIES OF BACKFLOW PREVENTERS "BFP-1" & "BFP-2" SHALL DRAIN INDIRECTLY (AND INDEPENDENTLY FROM ONE ANOTHER) INTO TRENCH DRAIN "TD-1" INSTALLED ADJACENT TO THE BACKFLOW PREVENTERS. THE INDIRECT WASTE PIPING SHALL BE CONSTRUCTED OF TYPE "L" COPPER AND HOLES (SLIGHTLY LARGER THAN THE DIAMETER OF EACH HOLES (SLIGHTLY LARGER THAN THE DIAMETER OF EACH INDIRECT WASTE PIPE) SHALL BE CUT INTO THE TRENCH DRAIN GRATES TO ACCOMMODATE THE INDIRECT WASTE DISCHARGE. REFER TO PLUMBING SHEET REFER TO PLUMBING SHEET P-101 FOR THE INSTALLATION LOCATION OF TRENCH DRAIN "TD-1". DOMESTIC WATER PIPING SHALL CONNECT TO THE EXISTING 1/2" DOMESTIC WATER PIPING CONNECTIONS LOCATED ON THE BACKSIDE OF THE EXISTING TWO FLOOR MOUNTED TANKS (TYPICAL OF FOUR 1/2" PIPE CONNECTIONS). EXISTING TANKS WILL BE RELOCATED FROM BUILDING P17 TO BUILDING P1 BY OTHERS. DOMESTIC WATER PIPING SHALL BE INSTALLED IN A MANNER THAT WILL NOT OBSTRUCT THE SERVICE ACCESS TO TRENCH DRAIN "TD-1" THAT COLLECTS THE INDIRECT WASTE FROM THE RELOCATED FLOOR MOUNTED TANKS. THE SERVICE ACCESS PATH BEHIND ALL OF THE FLOOR MOUNTED TANKS SHALL ALSO BE UNOBSTRUCTED. REFER TO PLUMBING SHEET P-101 FOR THE INSTALLATION LOCATION OF TRENCH DRAIN "TD-1". DOMESTIC WATER PIPING IS TO BE INSTALLED OVERTOP OF THE NEW MONORAIL STYLE HOIST AND ASSOCIATED SUPPORT BEAMS. REFER TO THE STRUCTURAL NEW WORK DRAWINGS FOR COORDINATION PURPOSES. ALL NEW DOMESTIC WATER PIPING SHALL BE INSTALLED IN A MANNER THAT WILL NOT INTERFERE WITH THE SWING RADIUS OF THE CURTAIN SUPPORT ARMS ATTACHED TO THE BACKSIDE OF THIS FLOOR MOUNTED TANK. THE EXISTING TANK AND ASSOCIATED CURTAIN SUPPORT ARMS WILL BE RELOCATED FROM BUILDING P17 TO BUILDING P1 BY OTHERS. EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE "ESEFW-1" SHALL BE INSTALLED IN THE LOCATION SHOWN. A DEPRESSED CONCRETE FLOOR SLAB (USED TO MINIMIZE RUNOFF OF WASTE WATER GENERATED BY THE EMERGENCY FIXTURE) WILL BE POURED IN THE AREA DEPICTED BY THE LIGHT-COLORED BOX. THE DEPRESSED FLOOR SLAB WILL BE COVERED WITH GRATING THAT IS PROCURED AND INSTALLED BY OTHERS. THE EMERGENCY FIXTURE SHOWER HEAD SHALL BE INSTALLED CENTERED OVERTOP OF THE DEPRESSED CONCRETE FLOOR SLAB. SCH. 40 SOLID WALL PVC PIPE, SCH. 40 GALVANIZED STEEL PIPE OR TYPE "L" COPPER SHALL BE USED TO INDIRECTLY DRAIN THE EMERGENCY EYE/FACE WASH COMPONENT OF THE FIXTURE THROUGH THE GRATING INSTALLED OVERTOP OF THE DEPRESSED FLOOR SLAB. THE INDIRECT WASTE PIPE SHALL NOT INTERFERE WITH THE ADA CLEARANCE OF THE EMERGENCY FIXTURE. DOMESTIC WATER PIPING SHALL CONNECT TO THERMOSTATIC MIXING VALVE "TMV-1" THAT SERVES THE NEW EMERGENCY SHOWER AND EYE/FACE WASH FIXTURE "ESEFW-1". DOMESTIC WATER PIPING FROM THE THERMOSTATIC MIXING VALVE SHALL CONNECT FULL LINE SIZE TO THE EMERGENCY FIXTURE. THE SUPPLY TEMPERATURE SET POINT OF THE THERMOSTATIC MIXING VALVE SHALL BE ADJUSTED TO 85°F.DOMESTIC WATER PIPING SHALL BE INSTALLED OVERTOP OF AND DOWN THROUGH THE NEW PRECAST/CAST-IN-PLACE CONCRETE CEILING OF THE LARGE-PARTS WASH BAY. PIPING PENETRATIONS THROUGH THE CONCRETE CEILING SHALL BE SEALED TO PREVENT LIGHT PENETRATION INTO THE LARGE-PARTS WASH BAY. HOSE STATION "HS-1". TOP ELEVATION OF HOSE STATION SHALL BE APPROXIMATELY 4'-6" ABOVE THE FINISHED FLOOR ELEVATION. A WATER PRESSURE REDUCING VALVE SHALL BE INSTALLED DOWNSTREAM OF THE HOSE STATION'S WATER MIXING CHAMBER BUT, UPSTREAM OF THE HOSE STATION'S HOSE CONNECTION. REFER TO THE HOSE STATION "HS-1" LINE ITEM IN THE PLUMBING FIXTURE SCHEDULE ON PLUMBING SHEET P-601 FOR ADDITIONAL INFORMATION. SINK "S-1". THE FLOOD-LEVEL RIM OF THE SINK SHALL BE INSTALLED 3'-0" ABOVE THE FINISHED FLOOR ELEVATION. DOMESTIC WATER SUPPLY PIPING FOR SINK "S-1" SHALL BE INSTALLED IN THE LOCATION SHOWN IN LIEU OF BEING INSTALLED ON THE LEFT-HAND SIDE OF THE SINK. REFER TO THE "SPECIALTY EQUIPMENT SCHEDULE" ON ARCHITECTURAL DRAWING AE-401 FOR A DESCRIPTION OF THE EQUIPMENT ASSOCIATED WITH THE EQUIPMENT TAG NUMBER (TYPICAL).
AutoCAD SHX Text
PLUMBING KEYED NOTES - DOMESTIC WATER PIPING NEW WORK:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text
AutoCAD SHX Text HANGERS/SUPPORTS AND ASSOCIATED ATTACHMENT HARDWARE SHALL NOT BE ANCHORED INTO THE BUILDING'S CONCRETE STRUCTURAL BEAMS AND COLUMNS. HANGERS/SUPPORTS AND ASSOCIATED ATTACHMENT HARDWARE MAY BE ANCHORED INTO THE CMU WALLS AND CONCRETE CEILING.
AutoCAD SHX Text
PLUMBING GENERAL NOTES:
AutoCAD SHX Text 1.
AutoCAD SHX Text
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
0910111213
R E
V I S
I O
N D
A T
E
S p r i n g f i e l d
I l l i n o i s
H a n s o n
P r o f e s s i o n a l
S e r v i c e s
I n c
S o u t h
S i x t h
S t r e e t
P h o n e d
W i n g
I l l i n o i s
A i r
N a t i o n a l
G u a r d
O k l a h o m a
C i t y
O
K
N G
B
I D n t r a c t
W
L
D
B r o a d w a y
E x t e n s i o n
S u i t e
P h o n e
R E
P A
I
B
U I L D
I N
G
P
S P
R I N
G F
I E
L D
I L
TYPE B3 (100%) SUBMITTAL - 8/18/2017
P-103
SCALE:1/8" = 1'-0"
FIRST FLOOR COMPRESSED AIR PIPING DEMOLITION PLAN
F I R
O
M
P R
E S
S E
D
A
P
P
I N
G
D E
M O
L I T
I O
R
K
P
L A
N
SCALE:1/8" = 1'-0"
FIRST FLOOR COMPRESSED AIR PIPING NEW WORK PLAN
0 4' 8' 16'
0 4' 8' 16'
AutoCAD SHX Text EXISTING COMPRESSED AIR PIPING ILLUSTRATED BY THE LIGHT COLORED LINES SHALL REMAIN FOR CONTINUED USE (TYPICAL)
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
STRUCTURAL MAINTENANCE
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL MOUNTED COMPRESSED AIR OUTLET STATION SHALL REMAIN FOR CONTINUED USE
AutoCAD SHX Text
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
JOAP/ADMIN
AutoCAD SHX Text
AutoCAD SHX Text
PENETRANT INSPECTION LINE
AutoCAD SHX Text
AutoCAD SHX Text
SHORT TERM PARTS STORAGE
AutoCAD SHX Text 3/4"
AutoCAD SHX Text EXISTING COMPRESSED AIR PIPING ILLUSTRATED BY THE LIGHT COLORED LINES SHALL REMAIN FOR CONTINUED USE (TYPICAL)
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WALL MOUNTED COMPRESSED AIR OUTLET STATION SHALL REMAIN FOR CONTINUED USE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text
NEW TO EXISTING CONNECTION
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Hanson No.
AutoCAD SHX Text Filename
AutoCAD SHX Text Scale
AutoCAD SHX Text
LAYOUT
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text Date
AutoCAD SHX Text
REVIEWED
AutoCAD SHX Text 13D0027001
AutoCAD SHX Text
E-401.DWG
AutoCAD SHX Text
JPD
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text
JPD
AutoCAD SHX Text 06/03/17
AutoCAD SHX Text EXISTING QUICK CONNECT HOSE CONNECTION FITTING ILLUSTRATED BY THE DARK LINES SHALL BE DISCONNECTED FROM THE WALL MOUNTED COMPRESSED AIR OUTLET STATION AND SAVED FOR REINSTALLATION. EXISTING COMPRESSED AIR PIPING INSTALLED DIRECTLY UPSTREAM OF THE DISCONNECTED QUICK CONNECT HOSE CONNECTION FITTING IS TO BE EXTENDED AND THE DISCONNECTED QUICK CONNECTION FITTING WILL BE REINSTALLED. REFER TO THE "FIRST FLOOR COMPRESSED AIR PIPING NEW WORK PLAN" ON THIS SHEET FOR REINSTALLATION OF THE QUICK CONNECT HOSE CONNECTION FITTING. FOR REFERENCE PURPOSES, REFER TO THE "TYPICAL COMPRESSED AIR OUTLET STATION DETAIL" ON PLUMBING SHEET P-501 FOR A SCHEMATIC REPRESENTATION OF THE EXISTING WALL MOUNTED COMPRESSED AIR OUTLET STATION THAT IS CURRENTLY INSTALLED. EXISTING WALL MOUNTED COMPRESSED AIR OUTLET STATION ILLUSTRATED BY THE DARK LINES SHALL BE DISCONNECTED FROM THE COMPRESSED AIR PIPING SYSTEM AND SAVED FOR REINSTALLATION. REFER TO THE "FIRST FLOOR COMPRESSED AIR PIPING NEW WORK PLAN" ON THIS SHEET FOR REINSTALLATION OF THE WALL MOUNTED COMPRESSED AIR OUTLET STATION. EXISTING COMPRESSED AIR PIPING ILLUSTRATED BY THE DARK DASHED LINES SHALL BE REMOVED AND DISPOSED OF. EXISTING COMPRESSED AIR PIPING BRANCH CONNECTION SHALL REMAIN FOR CONTINUED USE. REFER TO THE "FIRST FLOOR COMPRESSED AIR PIPING NEW WORK PLAN" ON THIS SHEET FOR THE INSTALLATION OF NEW COMPRESSED AIR PIPING FROM THIS EXISTING BRANCH CONNECTION. EXISTING QUICK CONNECT HOSE CONNECTION FITTING SHALL BE DISCONNECTED FROM THE EXISTING COMPRESSED AIR PIPING AND SAVED FOR REINSTALLATION. REFER TO THE "FIRST FLOOR COMPRESSED AIR PIPING NEW WORK PLAN" ON THIS SHEET FOR REINSTALLATION OF THE QUICK CONNECT HOSE CONNECTION FITTING.
AutoCAD SHX Text
PLUMBING KEYED NOTES - COMPRESSED AIR PIPING DEMOLITION:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EXISTING QUICK CONNECT HOSE CONNECTION FITTING REMOVED DURING THE DEMOLITION PHASE AND SAVED FOR REINSTALLATION SHALL BE REINSTALLED IN THE LOCATION SHOWN. THE QUICK CONNECT HOSE CONNECTION FITTING SHALL BE REINSTALLED AT THE SAME ELEVATION ABOVE THE FINISHED FLOOR THAT IT WAS REMOVED FROM DURING THE DEMOLITION PHASE. CONTRACTOR SHALL CONNECT EXISTING FLOOR MOUNTED TESTING EQUIPMENT (EXISTING TESTING EQUIPMENT WILL BE RELOCATED FROM BUILDING P17 TO BUILDING P1 BY OTHERS) TO THE COMPRESSED AIR OUTLET STATION USING THE EXISTING FLEXIBLE AIR HOSE AND QUICK CONNECT HOSE CONNECTION FITTING ATTACHED TO THE EXISTING TESTING EQUIPMENT. COMPRESSED AIR PIPING IS TO BE INSTALLED OVERTOP OF THE NEW MONORAIL STYLE HOIST AND ASSOCIATED SUPPORT BEAMS. REFER TO THE STRUCTURAL NEW WORK DRAWINGS FOR COORDINATION PURPOSES. EXISTING COMPRESSED AIR OUTLET STATION REMOVED DURING THE DEMOLITION PHASE AND SAVED FOR REINSTALLATION SHALL BE REINSTALLED IN THE LOCATION SHOWN. THE COMPRESSED AIR OUTLET STATION SHALL BE INSTALLED APPROXIMATELY 4'-6" ABOVE THE FINISHED FLOOR ELEVATION TO MATCH THE ELEVATION OF OTHER COMPRESSED AIR OUTLET STATIONS INSTALLED NEARBY.