TWall_SOW_with_attachments.pdf
PDF 548 KB Posted
- Attached to
- Concrete Barriers
- Solicitation number
- W91SMC-14-T-0010
About this file
Attachment 0001 - SOW Attachment 0002 - Drawing Attachment 0003 - Photo
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work- 182d Airlift Wing, Illinois Air National Guard Concrete T-Wall
Barriers
Location of delivery:
182d Airlift Wing
2416 S. Falcon Blvd.
Peoria, IL 61607-5023
Quantity: 6 T-Wall barriers
Description of Commercial Item:
Dimensions: 4880 mm (16.00 ft) long, 2440 mm (8.0 ft) wide and 3960 mm (13.00 ft) high. Weight: 22.33tons
Concrete: The contractor shall supply barriers manufactured using grade K300 concrete. The standard precast concrete production procedure will be utilized.
Rebar: The contractor shall provide rebar with a tensile strength of 60,000 psi or better.
All rebar shall be tied together with 3 twists of wire. The contractor shall use deformed billet-steel to conform to ASTM A615 grade 60. Lifting hooks shall extend into the base of the barrier and terminate in a suitable manner.
Barrier Identification: Each barrier shall be marked with the manufacturers name and item number, as approved by the Contracting Officers Representative.
Delivery- Contractor will be required to deliver and position the concrete T-
Walls at the 182d Airlift Wing, Illinois Air National Guard located in Peoria, IL NLT 90 days after receiving award. T-walls will be positioned in accordance with the 182d Airlift Wing’s Base Civil Engineer guidelines.
Acceptability: The government reserves the right to reject any barriers supplied by the contractor for unacceptable materials or finish. Any surface cracking or voids is grounds for rejection. Any rejected barriers shall be destroyed by the contractor.
Warranty: The contractor shall provide a 1 year warranty for the barriers. Warranty shall provide that any barriers showing signs of cracking shall be replaced.
Base Access: The contractor is required to ensure their employees have the proper paperwork and documents to gain access to the Base (182d Airlift Wing). All Base
Access Requests will be routed through the Contracting Officer.
Point of Contact is the COR: LtCol Leach, Mindy at 309-633-5269.
melissa.grice Typewritten Text Attachment 0001, Statement of Work Concrete T-Wall Barriers dated 24 Sep 14 melissa.grice Typewritten Text melissa.grice
8’
16’
Lifting Hooks melissa.grice Typewritten Text Attachment 0002, Drawing, Concrete T-Wall Barriers melissa.grice Typewritten Text melissa.grice dated 24 Sep 14
T Wall Locatioin mindy.leach Text Box Row 5 mindy.leach Text Box Row 4 mindy.leach Text Box Row 1 mindy.leach Text Box Row 2 mindy.leach Text Box Row 3 mindy.leach Text Box Maintenance Access Lane mindy.leach Line mindy.leach Text Box Area to stockpile all demolished material mindy.leach Line melissa.grice
Attachment 0003, Photo, Concrete T-Wall Barriers dated 24 Sep 14
| SOW TWALLS |
| TWall drawing |
| Site Location for TWalls |
File details come from the government source that posted it. Updated .