Statement of Work

1.0 Scope. This Statement of Work (SOW) requires a Contractor to provide local exchange access services, analog and digital access transport services, and an inter/intra-Local Access Transport Area (LATA) interconnect functions. The Contractor shall provide all transmission facilities, equipment, materials, maintenance, test equipment, and design needed to perform and provide local access and transport services to designated demarcation point and destinations specified in Appendix 10. Access to the local exchange shall include operator assistance, directory assistance, and emergency E911 services. These services shall be limited to official Government services and shall not include any unofficial services such as residential or business services for non-Government entities or contractors.

2.0 Documents. The documents referenced in this SOW are intended to be commercial and industrial references for the purpose of developing a baseline of performance and some measure of quality for the local exchange access, data and transport services and functions. The contractor must obtain and follow all the latest revision(s) and/or addition(s) to the referenced documents and/or all other applicable regulations.

2.1 Competitive IntraLATA Technologies, Interface, and Services Reference Manuals. Copies of the documents listed under Paragraph 2.1 and supplemental paragraphs may be purchased from Telcordia Technologies, Inc. (formerly Bellcore Technical Information Center) at the following website: http://telecom-info.telcordia.com/site-cgi/ido/index.html.

2.1.1 Functional Requirements (Common Sections)

SR-3065

2000 LSSGR Guide

SR-504

SPCS Capabilities and Features

GR-505

Call Processing

GR-1364 Switch Processing Time GRs, Section 5.6

GR-506

Signaling for Analog Interfaces

GR-606

Common Channel Signaling

GR-317

Switching System GRs for Call Control Using ISDN User Part (ISDNUP)

GR-507

Transmission

GR-508

Automatic Message Accounting (AMA)

GR-2932 Database Functionalities

GR-478

Measurements and Data Generation

GR-2963 OTGR Sec 2.2 Network Element Configuration Mgmt - Software Mgmt

GR-510

System Interfaces

GR-782

SONET Digital Switch Trunk Interface Criteria

GR-518

Synchronization

GR-511

Service Standards

GR-512

Reliability

GR-513

Power

GR-63

NEBS Requirements: Physical Protection

GR-1089 Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment

GR-477

Network Traffic Management

GR-517

Traffic Capacity and Environment

GR-815

GRs for Network Element/Network System (NE/Ns) Security

GR-454

Generic Requirements for Supplier-Provided Documentation

GR-839

Generic Requirements for Supplier-Provided Training

GR-840

Supplier Support Generic Requirements

GR-540

Tandem Supplement

2.1.2 Residence and Business Customer Features (FSD 00 and 01 Series)

GR-520

Features Common to Residence and Business Customers I

GR-219

CLASS Feature: Distinctive Ringing/Call Waiting

GR-560

Individual Line

GR-561

Two-Party Line

GR-562

Manual Line Features

GR-563

Denied Termination

GR-564

Code Restriction and Diversion

GR-565

Voice/Data Protection

GR-218

CLASS Feature: Selective Call Rejection

GR-568

Series Completion

GR-569

Multiline Hunt Service

GR-31

CLASS Feature: Calling Number Delivery

GR-216

CLASS Feature: Customer Originated Trace

GR-391

CLASS Feature: Calling Identity Delivery Blocking Features

GR-567

CLASS Feature: Anonymous Call Rejection

GR-1188 CLASS Feature: Calling Name Delivery Generic Requirements

GR-575

CLASS Feature: Calling Identity Delivery on Call Waiting

GR-570

Speed Calling

GR-571

Call Waiting

GR-572

Cancel Call Waiting

GR-573

Business Group Call Waiting

GR-416

CLASS Feature: Call Waiting Deluxe

GR-1517 CLASS Feature: Outside Calling Area Alerting

GR-574

Business Group Automatic Callback

GR-215

CLASS Feature: Automatic Callback

GR-2948 Prompted Automatic Callback

GR-227

CLASS Feature: Automatic Recall

GR-577

Three-Way Calling

GR-578

Usage-Sensitive Three-Way Calling

GR-579

Add-On Transfer and Conference Calling Features

GR-580

Call Forwarding Variable

GR-581

Remote Call Forwarding

GR-217

CLASS Feature: Selective Call Forwarding

GR-586

Call Forwarding Subfeatures

GR-588

Customer Premises Message Registers

GR-1401 Visual Message Waiting Indicator Generic Requirements

GR-1512 Call Screening

GR-3006 Class Feature: Audible Voice Identity Delivery

GR-1520 Ring Control

GR-2913 Generic Requirements for Call Park

GR-590

Call Pickup Features

2.1.3 Private Facility Features (FSD 02 Series)

GR-600

Private Facility Access

GR-601

Outward Wide Area Telecommunications Service

GR-602

Customer Control

GR-603

Outgoing Facility Group Queuing

GR-604

Automatic Flexible Routing

GR-605

Auth. Codes for AFR & Account Codes for Basic Business Group & AFR

GR-610

Message Detail Recording (MDR)

GR-615

GRs for Message Detail Recording (MDR) Access Interfaces

GR-621

Traffic Data Provision Features

GR-32

CLASS Feature: Bulk Calling Line Identification

2.1.4 Customer Access Interfaces (FSD 04 and 05 Series)

GR-524

Attendant & Customer Switching System Features & Customer Interface

GR-30

Voiceband Data Transmission Interface

GR-1273 ADSI SPCS/Server Generic Requirements

GR-1193 GRs for a Dedicated Data Link Interface bet.an End Office SPCS and CPE

GR-283

Simplified Message Desk Interface (SMDI)

2.1.5 Public Telecommunications Features (FSD 10 Series)

GR-528

Public Telecommunications Service

2.1.6 Public Safety Features (FSD 15 Series)

GR-529

Public Safety

GR-2931 High Probability of Completion Network Capability

GR-2973 Lawful Access Feature: Switching Generic Requirements

2.1.7 Loop Capabilities (FSD 20-02 Series)

GR-666

Universal Pair Gain Systems

GR-672

Bridge Services on an IDLC System

2.1.8 Tone and Announcement Systems (FSD 20-06 Series)

GR-674

Special Information Tones

GR-675

Expanded Announcement System

2.1.9 Reverting Call Service (FSD 20-10 Series)

GR-677

Reverting Service

2.1.10 Nail-Up Circuits (FSD 20-16 Series)

GR-679

Nail-Up of Non-Switched Circuits on a Local Switch

2.1.11 Local Exchange Access Interfaces (FSD 20-24 Series)

GR-690

Exchange Access Interconnection

GR-691

Facility/Service Selective Dialing Switching and Signaling Requirements

GR-692

Exchange Access Operator Services System Signaling

GR-693

Presubscription Indication

GR-695

Integrated Multiple Access Switched Services

GR-697

Feature Group A

GR-698

Feature Group B

2.1.12 Interoffice Features (FSD 25 Series)

GR-1083 Generic Requirements for Exchange Access AMA

GR-1504 Generic Requirements for Wireless Service Provider AMA

GR-394

Switching System GRs for ICI Using The ISDN User Part (ISDNUP)

GR-531

Interoffice

2.1.13 Call Processing Features (FSD 30 Series)

GR-532

Call Processing Features

GR-220

CLASS Feature: Screening List Editing

GR-1436 CLASS Feature: Visual Screening List Editing

GR-1251 CLASS Feature: Numbering Plan Area Split Management

GR-2857 RTPFR: Generic Requirements for the Signaling System 7 (SS7) Release to Pivot (RTP) Phase I Network Capability

GR-2970 Service Provider Identification Capability Specification

2.1.14 Database Services (FSD 31 Series)

GR-533

Database Services - Service Switching Points

2.1.15 Data Services (FSD 32 Series)

GR-534

Public Switched Digital Service

2.1.16 Test Arrangements (FSD 40 Series)

GR-536

Trunk, Line, and Special Service Circuit Test

2.1.17 Administration Features (FSD 45 Series)

GR-730

Provisioning-Driven Memory Administration (PDMA)

GR-738

Local Point-to-Point Data Collection

TR-740

Stored Program Control System/Operations System (SPCS/OS) - Network Data Collection Operations System (NDC OS) Interface

GR-741

Network Administration Center (NAC) Input/Output (I/O) Channel

GR-745

Service Specific Call Gapping

TR-746

Stored Program Control System/Operations System (SPCS/OS) - Network Traffic Management Operations System (NTM OS) Interface via a Network Data Collection Operations System (NDC OS)

GR-747

An Alternative Implementation of an SPCS to NTM OS Interface via an NDC OS

2.1.18 Other LSSGR References.

TR-NWT-000682

Automatic Number Identification (ANI) and Operator Number

Identification (ONI) FSD 20-20-000

TR-TSY-000685

Flexible ANI Information Digit Assignment FSD 20-20-0100

GR-853

ISDN Call Forwarding

TR-TSY-000854

ISDN Call Pickup

TR-TSY-000855

ISDN Automatic Callback

TR-TSY-000859

ISDN Multiline Hunt Group

TR-TSY-00060

ISDN Calling Number Identification (CNI) Services

GR-1188

ISDN Call Name Delivery

TR-NWT-00119

ISDN Automatic Recall

GR-1242

ISDN Selective Call Rejection

GR-1326

ISDN Calling Name Identification

TR-NWT-001187

ISDN Calling Number Identification Services for PRI

GR-1367-CORE

ISDN Calling Name Identification for PRI

TR-NWT-000335

Voice Grade Special Access Service Transmission Parameter Limits and Interface Combinations offers by LEC to Customer

GR-303

Integrated Digital Loop Carrier Generic Requirements, Objectives, and Interface

GR-268

ISDN Access Call Control Switching And Signaling Requirements

TA-TSY-000041

Characterization of Subscriber Loop for Voice and ISDN Services

TR-NWT-000393

Generic Requirements for ISDN Basic Access Digital Subscriber

Lines

TR-NWT-000397

ISDN Basic Access Transport System Requirement

TR-TSY-000752

ISDN Primary Rate Access Transport System

GR-253

Synchronous Optical Network (SONET) Transport Systems:

Common Generic Criteria

GR-496

SONET Add-Drop Multiplex Equipment

GR-2842

ATM Service Access Multiplexer Generic Requirements

TR-TSY-000009

Asynchronous Digital Multiplexes, Requirements and Objectives

2.1.19 Other Reference Manuals.

ANSI T1X1.590-113, Synchronous Optical Network (SONET): Operations, Administration, Maintenance, and Provisioning.

ANSI T1.105-1991, Digital Hierarchy - Optical Interface Rates and Format

Specifications.

ANSI T1.P64-199x and T1P1.3/92-002R2, Digital Processing of Video Signals - Video Coder/Decoder for Audiovisual Services at 56 to 1536 Kbps, T1/LB-255, T1Y1/90-077.

BELLCORE TR-TSY-000020, General requirements for Optical Fiber and Optical Fiber Cable, Issue 9.

BELLCORE GR-2845-CORE, Issue 1, Generic Requirements for ATM Network and Element Management Layers.

BELLCORE GR-1111-CORE, Issue 1, B-ISDN Access Signaling Generic Requirements.

BELLCORE GR-1113-CORE, Issue 1, ATM and ATM Adapter Layer (AAL) Protocols.

BELLCORE GR-1118-CORE, Issue 1, Broadband Interswitching System Interface Generic Requirements.

BELLCORE TR-NWT-001112, Broadband ISDN User to Network Interface and Network Node Interface Physical Layer Generic Criteria.

2.1.20 Safety and Health Standards. The OSHA documents may be obtained from the Superintendent of Documents, US Government Printing Office, Washington DC, 20402. ANSI and NFPA documents may be obtained from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

OSHA CFR 29

Occupational Safety and Health Standards

Part 1910

OSHA CFR 29

Hazardous Waste Operation & Emergency Response

Part 1910.120

OSHA CFR 29

Confined Spaces

Part 1910.146

OSHA CFR 29

Telecommunication

Part 1910.268

OSHA CFR 29

Asbestos, Tremolite, Anthophyllite and Actinolite

Part 1910.1001

(Labor)

OSHA CFR 29

Hazard Communication

Part 1910.1200

OSHA CFR 29

Excavation

Part 1926, Subpart P

(650,651 & 652

OSHA CFR 29

Asbestos, Tremolite, Anthopyllite, & Actinolite

Part 1926.58

(Construction)

ANSI C2

National Electric Safety Code (NESC)

NFPA 70

National Electrical Code (NEC)

EPA CFR Parts 261, Hazardous Waste Generation &

262, & 263

Transportation

EPA Clean Air Act

National Environmental Code of Federal Regulations Parts

Protection Act, Title 40 1500 -1508

DODI 5000-2, Part 6 System Safety, Health Hazards &

Environment Impact

3.0 Requirements.

a. Appendix 10 identifies all services required, including characteristics, quantities and locations.

b. The Contracting Officer’s Representative (COR) is responsible for monitoring and accepting all services identified in Appendix 10. The Contractor shall coordinate with the COR before installing, removing or changing equipment.

c. The Government will provide rack space and electrical power for the installation of the Contractor’s transmission equipment. This rack space will be limited to two relay racks, 19 to 23 inches wide by 7 to 9 feet tall, if ceiling height permits at the designated demarcation. If additional rack space is required to support future Government requirements, the Contractor shall coordinate with the COR to determine if space is available.

d. The Contractor’s equipment shall be upgradeable or expandable to support changes in service requirements. To meet expansion requirements, the Contractor’s equipment shall be modularly expandable or reducible to permit growth or to migrate to higher or lower order services without requiring forklift upgrades.

3.1 Local Commercial Communications Services.

3.1.1 Installation and Cutover. The Contractor shall provide the Contracting Officer (KO) with an installation and cutover plan on the first day of the cut-over performance period (CLIN 0001). The Contractor shall not commence on-site installation and cutover until the Contractor receives notice that the Government has accepted the service installation and cutover plan. Installation and cutover shall be completed no later than 120 calendar days after Government acceptance of the cut-over plan. The Contractor will be responsible for issuing disconnect orders to the incumbent provider after successful activation and testing of each circuit.

3.1.2 Commercial Subscriber Lines & Exchange Access Trunks. Local exchange access, as applicable shall include commercial subscriber lines and off premise extensions, CENTREX, exchange access trunks and transport services.

3.1.2.1 Commercial Subscriber Lines. The Contractor shall provide subscriber lines as specified in Appendix 10. Local exchange access, as applicable, shall include commercial subscriber lines and foreign exchange lines.

3.1.2.2 Commercial Subscriber Line Basic Services. Basic services of a line, as a minimum, shall include the following:

· dial tone

· direct inward dialing

· direct outward dialing

· Dual Tone Multi-Frequency (DTMF) capability for local exchange and long distance access

· equal access

· call blocking for Numbering Area Plan (NPA) 900 and NPA 976

· Block Operator Assistance (0+ & 00+)

· E911/911 services in all cases and 311 services where available

· non-published directory number

· service disconnect with referral service of at least three (3) months after a customer’s number has been changed or disconnected

· block Directory Assistance Call Completion (DACC) and Directory Assistance.

· block third-party billing

· block 10-10 dialing

· block Collect Calls

· block Automatic Call Return Feature

3.1.2.3 Commercial Subscriber Line Additional Features. The Contractor shall make available to commercial subscribers additional line features as specified in Appendix 10. An additional feature may be an individual feature or a group of features.

3.1.2.4 CENTREX Features. CENTREX Basic Feature Package (CBFP) shall be as specified in Appendix 10. Minimum Centrex backups must be maintained for emergency E911 services to Defense Emergency Services (DES).

3.1.2.5 Subscriber Line Relocation. The Government will perform subscriber line relocation unless otherwise specified in the SOW. The Contractor shall perform database updates for address changes for emergency E911 service purposes when required by the SOW.

3.1.2.6 Exchange Access Trunks. The Contractor shall provide local exchange access service circuits for local trunks as specified in Appendix 10.

3.1.2.7 Exchange Access Trunks Basic Services. Basic services of an (local or foreign exchange) access trunk, as a minimum, shall include the following, as applicable:

· direct inward dialing

· direct outward dialing

· two-way dialing

· channelization of digital trunks (as specified by work order)

· trunk busy tones

· DTMF MF 2/6 and dial pulse address signaling

· access services

· block DACC

· trunk and/or trunk group establishment

· automatic trunk member selection (sequential, linear, most idle, etc.)

· automatic trunk group alternate route selection

· block third-party billing

· Access to 1-800 calling

· Access to Government Emergency Telephone System (GETS)

· Caller ID

3.1.3 Transport Services. The Contractor shall provide local exchange transport channel services as specified in Appendix 10. Local transport channel services include transport channel termination and transmission support, as applicable, for analog lines, ISDN lines, alarm circuits, data circuits up to 64 Kbps or aggregate N x 64 Kbps, Primary Rate ISDN, Broadband-ISDN, High Capacity Data Subscriber Line (HDSL), Digital Signal level 1 (DS-1), DS-3, Optical Carrier Signal level 1 (OC-1), OC-3, and may be expanded to OC-12, and OC-48.

3.1.4 Circuit Termination. Circuit termination at the Government installation includes the Main Distribution Frame (MDF) for analog signals and metallic cable pairs, DSX-1 patch and cross connect panel for T-1 circuits, DSX-3 for electrical T-3 circuits, fiber optic patch and cross connect panels for optical interface equipment such as the optical carrier or SONET systems, optical multiplexer equipment, and Cat 3/5 RJ-45 jack fields. Other wall-mounted, punch-down, terminal blocks are used for isolation and termination of Contractor metallic facilities. The Contractor shall ensure that all circuits are clearly tagged in a permanent manner with the circuit identification number or telephone number assigned to the circuit, and the work order number.

3.1.4.1 Analog and Low Data Rates. The Contractor shall terminate the analog and lower rate data circuits to the Contractor’s terminal blocks. The Government shall provide space for installation of Contractor’s blocks. All outside plant copper cables entering the demarcation location must be electrically protected (grounded, terminated on protector modules, etc.).

3.1.4.2 High Data Rates. The Contractor shall properly terminate digital circuits to the Contractor provided DSX-1, DSX-3, or fiber optic patch panel.

3.1.4.3 Circuit Testing. The Contractor shall test circuits after installation and provide test results to the COR in writing. The Contractor shall document the circuit characteristics in the Customer Service Records.

3.1.5 Local Exchange Access and Service Areas. The Contractor shall provide local services for both subscriber lines and trunks within the local calling areas. The local access service areas shall, as a minimum, include the areas/zones coverage as currently defined by the local service provider(s) and/or the applicable State Public Utilities Commission (PUC). The local and foreign exchange access service areas shall be, as a minimum, bounded by geographic city areas/zones and/or surrounding areas. The access areas shall not be limited by prefixes that may change. The local service areas/zones/boundaries shall not be reduced. If the contractor determines that the local/foreign exchange access service areas are different than defined, the Contractor shall coordinate with the COR and the KO for approval. When the Contractor provides services to a Government installation, the LATA boundary shall not be limited or restricted to a Contractor’s service area. Connection to intra-LATA exchange areas and with inter-LATA exchange carriers is an essential part of the local exchange access.

3.1.6 Number Portability. The Contractor shall provide number portability for commercial subscriber lines and local exchange direct-in-dial (DID) directory numbers. The consistent use of the same prefix exchange and directory numbers provides the Government installation with its commercial identity. The Contractor shall provide an additional block of DID directory numbers within the existing assigned NXX prefix exchanges to the installation until exhausted. The Government installation is also serviced by other Government switched networks, FTS 2001 and the Defense Switched Network (DSN). These networks provide DID trunks and are directly dependent on the mutually assigned DID numbers to terminate into stations on the installation. Local exchange number portability and DID number growth is a critical factor in the ability of a Government installation to support its personnel and its missions. The Contractor shall comply with the Federal Communications Commission (FCC) and the State Public Utility Commission (PUC) mandates for number portability.

3.1.7 Demarcation. The Government will designate the demarcation point (location) for Contractor equipment installation and termination of transport facilities. The typical location of the primary demarcation point is the Government Dial Central Office (DCO).

3.1.7.1 Circuit Extension. The Government may extend a service or circuit beyond the established demarcation to a Government termination point. When local exchange access requirements indicate the Contractor requires circuit extension, the Contractor shall provide circuit extension through circuit termination and/or Contractor owned/leased transport cable.

3.1.7.2 Government Cable. When Government cable is available, the Contractor shall provide circuit termination for a circuit extension. Circuit termination shall include transmission equipment, termination hardware, and circuit conditioning equipment required to extend a circuit to a user location.

3.1.7.3 Contractor Owned/Leased Transport Cable. When Government cable is not available, the Contractor shall provide the circuit transport.

3.1.8 Contractor Equipment and Cable Installation. The Contractor shall provide and install all transmission equipment and cables to provide services to the demarcations. The Contractor shall coordinate with the COR for equipment and cable installation. The Contractor shall install equipment and cables in accordance with all applicable safety codes. The Contractor shall be responsible for wiring and connecting to Government power connection points, ground master connection points, and termination frames for terminal blocks.

3.1.9 Restoration of Service and Maintenance. The Contractor shall provide a point of contact (POC) for the Government to report all service outages. The POC shall be available 24 hours a day, 7 days per week. The Government will classify outages as either “Catastrophic,” “Emergency,” “Serious,” or “Routine,” depending on the impact on Government services. The COR will notify the Contractor of the classification when reporting the outage. The Contractor shall respond to and correct service outages within the time limits specified. If the Contractor determines the restoration time frames cannot be met, the Contractor shall immediately notify the COR. The Contractor shall respond to the Government within one (1) hour of notification.

3.1.9.1 Catastrophic Outage. Restore service within four (4) hours from the time the Contractor responds to the Government’s notification.

3.1.9.2 Emergency Outage. Restore service within eight (8) hours from the time the Contractor responds to the Government’s notification.

3.1.9.3 Serious Outage. Restore service within twenty-four (24) hours from the time the Contractor responds to the Government’s notification.

3.1.9.4 Routine Outage. Restore service within two (2) calendar days from the time the Contractor responds to the Government’s notification.

3.1.10 Diversity/Diverse Routing. The Contractor shall provide diversity for local communications services as required in the Appendix 10. Diversity is primarily considered to be designed redundant paths, rings, etc., along with the electronic systems in the path that permit transport channels to reach their destination demarcation point in the local exchange without interruption in the event of the failure of one path.

3.1.11 Operator Assistance. The Contractor shall provide operator assistance for local exchange and access services, including, as a minimum but not limited to, subscriber line verification, barge-in, call extension, and assistance with other exchange access functions.

3.1.13 E911/311 Services. The Contractor shall provide access to enhanced 911 services, if available, through the local emergency services organization, to include transmission of all 911 and E911 ANI/ALI information to the applicable PSAP. The contractor shall update the Master Street Address Guide (MSAG) with updates provided periodically by the Government. All outgoing city trunks must provide Automatic Number Identification (ANI) of the caller to the local city enhanced 911 network in the proper format to enable Automatic Location Identification (ALI) to be properly retrieved by the primary and back-up enhanced 911 Public Safety Answering Points (PSAPs). Emergency service assistance shall be provided for the hearing impaired. The Contractor shall provide access to 911 or enhanced 911 services, where available, through the local city or county emergency services organization

3.2 Future Services. The Contractor shall provide future services as required by Appendix 10. After acceptance of a contract modification, the Contractor shall complete the installation or disconnection of services within the time frames defined below.

3.2.1 Emergency Services. The time frame is one calendar day.

3.2.2 Priority Services. The time frame is five calendar days.

3.2.3 Routine Services. The time frame is 10 calendar days.

3.2.4 Traffic Analysis. The Contractor shall perform traffic measurement and traffic analysis as required.

3.3 Customer and Communications Service Records. The Contractor shall be responsible for creating and updating the local service records. The local service records shall include customer service records and communications service records and shall be provided to the COR and/or the Contracting Officer upon request.

The Contractor shall update Customer and Communications service records not later than 10 working days after a service has been activated or deactivated.

3.4 Contract Management.

3.4.1 Meetings. The Contractor’s project manager shall be available Monday to Friday, between 7:00 a.m. to 5:00 p.m. local time, to meet the COR on-site for technical interchange discussions. The Contractor’s project manager shall have full authority to effect service changes requested by the Government.

3.4.2 Support. The Contractor shall assist the COR with testing and implementation of a new service circuit or expansion to existing circuits. The Contractor shall cooperate with the COR or other vendors that may be interconnecting with other related services. When expansion services entail Contractor support that requires additional equipment or testing to activate a circuit, the Contractor shall develop the installation and activation plans with the COR.

3.4.3 Point-of-Contact. The Contractor shall provide a 24-hour point-of-contact telephone number for the notification of telephone/circuit outages and services prior to service cutover.

3.5 Regulations and Policies. The Contractor shall follow all base regulations and policies regarding security, safety, and environmental, and federal, state and local regulations, as applicable.

3.5.1 Safety Training and Education. The Contractor must have a safety and health plan for the employees that complies with all applicable Federal, State, local and Army requirements.

3.5.2 Safety and Health. The Contractor shall meet with civil engineering, safety and bioenvironmental personnel before beginning work surveys in areas that may contain asbestos and/or other hazardous materials or may result in hazardous wastes. The Contractor shall follow Army procedures as outlined by personnel in these offices, including procedures for disposal of residue hazardous materials and empty hazardous materials containers.

3.5.3 Hazardous Material Reporting on Federal Installations. The Contractor is required to provide Material Safety Data Sheets (MSDS) on each hazardous material/compound that will be used in performing this contract. The Contractor will provide the MSDS to the federal facilities Environmental Management Office for approval before using any hazardous materials (paints, solvents, cleaners, encapsulating compounds, etc.). Hazardous materials are not permitted on any federal facility until the local Environmental Management Office has approved their use. There are no exceptions to this requirement, and the Contractor shall ensure compliance whether the Contractor or a subcontractor performs the work.

3.5.4 Ozone Depletion. No ozone-depleting chemicals or compounds shall be used during the performance of work.

3.5.5 Work Clearance Request. The Contractor shall obtain clearance from the Directorate of Engineering and Housing (DEH) or the Department of Public Works (DPW) before trenching, digging, or modifying a facility. The Contractor shall ensure that all the following requirements are met. All open trenches and open holes must be properly protected by use of barricades and warning signs. Trenches, pits, and holes that employees have to enter must be protected from excavated materials or equipment that could fall or roll into the excavated area. Therefore, all excavated materials and equipment must be a minimum of two feet from the edge of the trench, pit, or hole. Shoring will not be required for trenches, pits and holes less than 5 feet deep. Exceptions will depend on the type of soil and the amount of rain in the area (Ref OSHA 1926 Appendix A to Subpart P, Soil Classification). Employee protection for working in a trench, pit, or hole can also be accomplished by sloping and/or benching (Ref OSHA 1926.652 for configurations). Excavations that are next to sidewalks and roadways shall be guarded by barricades with flashing lights. Excavations that go under sidewalks shall be guarded with handrails on both sides and supported to keep from collapsing. Excavations under roadways shall have support structures installed to support the roadway. Support structures will be approved by DEH or DPW, as applicable. All excavated areas shall be back filled and/or restored to the original condition when the work has been completed. Confined spaces entry (i.e., entering manholes, tunnels, and unvented vaults) shall be coordinated with the local safety and health offices prior to entry. Confined spaces atmospheric testing shall be accomplished by testing oxygen levels, toxic levels, and combustible levels consistent with local base procedures for entering and working in confined spaces. If work is being performed in a confined space, then forced air ventilation is required. Under no circumstances shall the Contractor handle, transport, or dispose of hazardous waste materials. This is solely the facility owner’s responsibility.

3.5.6 Accident/Incident Reporting and Investigation. The Contractor shall record and report to the COR all available facts relating to each instance of accidental damage to Government property or injury to either Contractor or Government personnel. The Contractor shall secure the accident scene and/or wreckage until released by the COR or contracting officer. The Contractor shall cooperate fully with any investigation and assist the investigators in any way necessary.

3.5.7 Section 508 Compliance. Services within the Statement of Work are exempt under FAR 39.204(d).

APPENDIX 10

REQUIRED LOCAL COMMERCIAL COMMUNICATIONS SERVICES AT CUTOVER

10.0 Local services required from the Contractor, are initial installation and cutover service requirements for the Government under the scope of this contract. The Contractor shall provide the following baseline of local commercial communications services at cutover. The quantity of these requirements will be incorporated into the Pricing Schedule.

· Verizon is currently providing the local exchange access services at the Aberdeen Proving Ground (Aberdeen and Edgewood Areas), Aberdeen Proving Ground, Maryland.

· The Aberdeen Area of Aberdeen Proving Ground is serviced by an AVAYA S8720 and an AVAYA S8710 switching system with software release Communication Manager 4.02. The demarcation point in the Aberdeen Area for all commercial circuits (except where noted in the table below) is Building 311 at 6851 Civil Road, Aberdeen Proving Ground, Maryland 21005.

· The Edgewood Area of Aberdeen Proving Ground is serviced by an AVAYA S8720 switching system with software release Communication Manager 4.02. The demarcation point in the Edgewood Area for all commercial circuits (except where noted in the table below) is Building E5103 at 8276 Rouse Road, Aberdeen Proving Ground, Maryland 21010.

· The official primary inter-LATA and intra-LATA service provider for local and long distance service is NETWORX. The Primary Interchange Carrier (PIC) will be NETWORX for all services under this contract.

· Any items in the tables listed below, marked ‘NEW’ and highlighted in yellow shall be installed and working within 30 business days after contract award.

10.1 Direct-In-Dial Directory Numbers. Aberdeen Area:

NPA- NXX-XXXX
DID Directory Numbers
410-278-0000 to 0799
800
410-278-0820 to 8019
7200
410-278-8500 to 8859
360
410-278-8880 to 9999
1120
410-306-0000 to 4999
5000
410-306-8780 to 8799
20
410-306-8700 thru 8719 TLI 410-306-8845
20
443-395-0000 to 9999
10000
443-861-0000 to 9999
10000
TOTAL
34,520

10.1.1 Direct-In-Dial Directory Numbers. Edgewood Area:

NPA- NXX-XXXX
DID Directory Numbers
410-436-0000 to 9999
10,000
410-417-0000 to 4999
5,000
TOTAL
15,000

10.2 Commercial Subscriber Lines.

10.2.1 Commercial Subscriber Lines, Aberdeen Area.

#
NPA-NXX-XXXX
Type
Features
Demarcation
Description
1
410-272-0424
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
ATC – Bldg 358 Lanyard Road
2
410-272-1390
Analog, Loop, 2-wire
In hunt group behind 410-273-1335
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
ATC – Bldg 359 Recoil Road
3
410-272-1688
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
Dialup Modem, (Noise Monitoring Circuit), ATC - Tower at Mulberry Point, near Bldg 646 (GPS Coordinates: 39.26.44N / 76.06.10W)
4
410-272-3266
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
ATC – Trailer Park (#103)
5
410-272-6606
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
ATC - Bldg 400, Rm F-1 (SAD: 399 Mulberry Point)
6
410-272-8842
Analog, Loop, 2-wire
Basic
Service address 500 Edgewood Rd
DSHE – Bldg E5183 (Environmental Hotline – phone forwarded to E5183 on 410-417-2035)
7
410-273-0256
Analog, Loop, 2-wire
Basic
Bldg 3400 - 6444 Aberdeen Blvd, Aberdeen Proving Ground, MD 21005
DECA – Bldg 3400 (Commisary)
8
410-273-0482
Analog, Loop, 2-wire
Basic
Bldg 3400 - 6444 Aberdeen Blvd, Aberdeen Proving Ground, MD 21005
DECA – Bldg 3400 (Commisary)
9
410-273-6193
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES - Bldg 2200, Dispatch
10
410-273-6196
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DPW - Bldg 4304
11
410-273-6443
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
Dialup Modem RNEC – Bldg 311
12
410-273-7529
Analog, Loop, 2-wire
Basic
Pole located at Water Treatment Plant, 411 South Old Post Road, Aberdeen, MD
Dialup Modem, (Noise Monitoring Circuit), ATC – Noise Monitoring on Pole at Water Treatment Plant, 411 S. Old Post Road, Aberdeen, MD
13
410-273-7782
Analog, Loop, 2-wire
Basic
Pole located at Michaelsville Rd Perryman, MD; GPS Coordinates 39.28.03 North/76.12.15 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Perryman, MD
14
410-273-8975
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – Bldg 2478 ( E911 Center)
15
410-275-1287
Analog, Loop, 2-wire
Basic
Pole located at Grove Neck Rd/New, Hampshire Ave, Grove Point, MD; GPS coordinates 39.23.46 North/76.02.14 West
Dialup Modem (Noise Monitoring Circuit) ATC - Grove Point, MD
16
410-275-2384
Analog, Loop, 2-wire
Basic
Pole located at 4th St & Beachwood Ave., Crystal Beach, MD. GPS coordinates 39.26.41 North/75.58.19 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Crystal Beach, MD
17
410-278-5201
Analog, Loop, 2-wire
Caller ID
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
RNEC – Bldg 311, Main Installation Number (ADAS)
18
410-287-8283
Analog, Loop, 2-wire
Basic
150 Bayview Blvd, Red Point Rd., Charlestown, MD; GPS coordinates 39.31.32 North/75.58.49 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Charlestown, MD
19
410-287-8401
Analog, Loop, 2-wire
Basic
Pole located at Water St., Conestoga, Charlestown, MD; GPS coordinates 39.34.14 North/75.58.23 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Charlestown, MD
20
410-297-6401
Analog, Loop, 2-wire
Basic
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES - Bldg 3147, EOC
21
410-335-1960
Analog, Loop, 2-wire
Basic
Pole located at Bay Drive, Middle River MD; GPS coordinates 39.18.05 North/76.22.35 West
Dialup Modem, (Noise Monitoring Circuit) ATC – Middle River, MD
22
410-348-2211
Analog, Loop, 2-wire
Basic
Pole located at Idlewhile Ave., Betterton, MD; GPS coordinates 39.22.10 North/76.04.02 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Betterton, MD
23
410-457-4159
Analog, Loop, 2-wire
Basic
No address available Deer Creek Water Station, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long 76°11'30.7" per Google
DPW - Darlington, MD
24
410-457-4307
Analog, Loop, 2-wire
Basic
Deer Creek Pumping Station, No address available Darlington Rd, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long 76°11'30.7" per Google
ATC - Darlington, MD
25
410-457-4980
Analog, Loop, 2-wire
Basic
Deer Creek Pumping Station, No address available Darlington Rd, Darlington, MD 21034; GPS coordinates Lat 39°37'02.8", long 76°11'30.7" per Google
ATC - Darlington, MD *USGS Deer Creek Flow
26
410-676-1631
Analog, Loop, 2-wire
Basic
Pole located at Harford Sq Drive, Edgewood, MD 21040; GPS coordinates 39.25.11 North/76.19.16 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Edgewood, MD
27
410-676-6443
Analog, Loop, 2-wire
Basic
Pole located at Long Bar Harbor Rd, Abingdon, MD; GPS coordinates 39.27.22 North/76.15.00 West
ATC - Abingdon, MD
28
410-734-5950
Analog, Loop, 2-wire
Basic
775 Priestford Rd., Bldg 10301, Churchville, MD.
ATC – Bldg 10301
29
410-734-5951
Analog, Loop, 2-wire
Basic
775 Priestford Rd., Bldg 10301, Churchville, MD.
ATC – Bldg 10301
30
410-734-5952
Analog, Loop, 2-wire
Basic
775 Priestford Rd., Bldg 10301, Churchville, MD.
ATC – Bldg 10301
31
410-734-6125
Analog, Loop, 2-wire
Basic
775 Priestford Road , Bldg 10301, Churchville, Md 21028
DES – Churchville, MD
32
410-734-6239
Analog, Loop, 2-wire
Basic
775 Priestford Road , Bldg 10301, Churchville, Md 21028
DES – Churchville, MD
33
410-734-6511
Analog, Loop, 2-wire
Basic
ChurchvilleTest Area, 775 Priestford Rd, Bldg 10301, Churchville, MD
ATC – Bldg 10301
34
410-734-7040
Analog, Loop, 2-wire
Basic
Bldg 10301, 775 Priestford Rd, Churchville, MD
ATC – Bldg 10301
35
410-734-7042
Analog, Loop, 2-wire
Basic
775 Priestford Road , Bldg 10301, Churchville, Md 21028
ATC – Bldg 10301
36
410-734-7647
Analog, Loop, 2-wire
Basic
ChurchvilleTest Area, 775 Priestford Rd, Bldg 10301, Churchville, MD
ATC – Bldg 10301
37
410-778-9023
Analog, Loop, 2-wire
Basic
Pole 21 located at Elm St. Tolchester, MD; GPS coordinates 39.13.34 North/76.13.56 West
Dialup Modem, (Noise Monitoring Circuit) ATC Tolchester, MD
38
410-778-9024
Analog, Loop, 2-wire
Basic
Pole located at Handy Point Rd., Stoops Point, MD; GPS coordinates 39.16.47 North/76.11.59 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Stoops Point, MD
39
410-778-9025
Analog, Loop, 2-wire
Basic
Pole located at Smithfield Rd., Worton Point, MD; GPS coordinates 39.18.08 North/76.11.07 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Worton Point, MD
40
410-810-0350
Analog, Loop, 2-wire
Basic
Pole located at Howell Pt Rd., Howell Point, MD; GPS coordinates 39.21.38 North/76.06.59 West
Dialup Modem, (Noise Monitoring Circuit) ATC - Howell Point, MD
41
410-939-5258
Analog, Loop, 2-wire
Basic
Pole located Concord / Alliance St., Havre de Grace, MD; GPS coordinates 39.32.28 North/76.05.06 West
ATC - Havre de Grace, MD

10.2.2 Commercial Subscriber Lines, Edgewood Area.

#
NPA-NXX-XXXX
Type
Features
Demarcation
Description
1
410-676-1364
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
ECBC – Bldg E3401
2
410-676-1365
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
ECBC – Bldg E3401
3
410-612-5981
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
ECBC – Bldg E3401
4
410-612-5982
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
ECBC – Bldg E3401
5
410-612-5983
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
ECBC – Bldg E3401
6
410-612-0577
Analog, Loop, 2-wire
Basic
1 ARMY CHEMICAL CTR GUNPOWDER, Aberdeen Proving Ground, MD 21010 (Edgewood Area)
Aberdeen Proving Ground, MD (Edgewood Area)
7
410-612-0656
Analog, Loop, 2-wire
Basic
1 ARMY CHEMICAL CTR GUNPOWDER, Aberdeen Proving Ground, MD 21010 (Edgewood Area)
Aberdeen Proving Ground, MD (Edgewood)
8
410-612-0923
Analog, Loop, 2-wire
Basic
1 ARMY CHEMICAL CTR GUNPOWDER, Aberdeen Proving Ground, MD 21010 (Edgewood Area)
Aberdeen Proving Ground, MD (Edgewood Area)
9
410-612-0951
Analog, Loop, 2-wire
Basic
1 ARMY CHEMICAL CTR GUNPOWDER, Aberdeen Proving Ground, MD 21010 (Edgewood Area)
Aberdeen Proving Ground, MD (Edgewood Area)
10
410-676-0960
Analog, Loop, 2-wire
Basic
B ldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – Bldg E5180 (APGFD Commercial 911)
11
410-676-1246
Analog, Loop, 2-wire
Basic
1 ARMY CHEMICAL CTR GUNPOWDER, Aberdeen Proving Ground, MD 21010 (Edgewood Area)
Aberdeen Proving Ground, MD (Edgewood Area)
12
410-671-6147
Analog, Loop, 2-wire
Basic
Bldg E6110 – 1126 Edgewood Road, Edgewood, MD 21040
DPW – Bldg E6110 (Van Bibber)
13
410-676-0143
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
RNEC – Bldg E5103 (Remote Dial Up)
14
410-676-0876
Analog, Loop, 2-wire
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
RNEC – Bldg E5103

(Remote Dial Up)

15
410-671-7231
Analog, Loop, 2-wire
Basic
Bldg E6110 – 1126 Edgewood Road, Edgewood, MD 21040
DPW – Bldg E6110 (Van Bibber)
16
410-612-8088
2-wire
Basic
Bldg E6110 – 1126 Edgewood Road, Edgewood, MD 21040
DPW – Bldg E6110 (Van Bibber), Otter Point Creek US Geological Survey
17
410-616-6106
Analog
Basic
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center

10.2.3 Commercial Subscriber Lines, ISDN BRI Lines, Aberdeen Proving Grounds.

#
NPA-NXX-XXXX
Type
Features
Demarcation
Description
1
410-272-9487/9488 38.IBZD.385281 CM
ISDN- BRI single line business pipe
Switched Voice & B Channel
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
NEC - Aberdeen Proving Ground, MD

10.2.4 E911 CAMA /ALI AND 311 Trunk/Lines.

#
Circuit ID
Type
Rate
Demarcation
Description
1
CAMA - 1: 91.EMNT.410.911.2720
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

2
CAMA - 2: 91.EMNT.410.911.2721
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

3
CAMA - 3: 91.EMNT.410.911.2722
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

4
CAMA- 4: 91.EMNT.410.911.2723
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

5
ALI - 1: 91.DRYZ.200205.MD
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP

6
ALI - 2: 91.DRYZ.100.773.MD
Analog Circuits
Voice Grade data circuit
Bldg 311 – 6851 Civil Road, Aberdeen Proving Ground, MD 21005
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP

7
NEW CAMA-1
Analog Circuit
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

8
NEW CAMA-2
Analog Circuit
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

9
NEW CAMA-4
Analog Circuit
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

10
NEW CAMA-4
Analog Circuit
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN Pikesville / Ellicott City MD- MD PSAP

11
NEW ALI-1
Analog Circuits
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP

12
NEW ALI-2
Analog Circuits
Voice Grade data circuit
Bldg E5103 – 8276 Rouse Road, Aberdeen Proving Ground, MD 21010
DES – E4224, E911 Center. APG MD EMS

APG MD-VRZN ABDN C0-VRZN ALISA Fairland MD/ Freehold NJ- MD PSAP

10.3 Local Exchange Digital (ISDN PRI) Trunks. Estimated usage 40,100 minutes per PRI. All B-Channels are 2 Way. All PRIs must provide caller ID.

10.3.1 ISDN PRI Trunks, Aberdeen Area.

#
ISDN PRI Circuit ID
D-Channel
B-Channels & Signaling
Demarcation
1
38IPZD.103158.1 MD
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
2
38IPZD.103158.-02
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
3
38IPZD.103158.-03
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
4
38IPZD.103158.-04
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
5
38IPZD. 103158.-05
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
6
38IPZD. 103158.-06
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
7
38IPZD. 103158.-07
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
8
38IPZD. 103158.-08
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
9
38IPZD. 103158.09
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
10
38IPZD.103158.-10.
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
11
38IPZD. 103158.-11
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
12
38IPZD. 103158.-12
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
13
38IPZD. 103158.-13
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
14
38IPZD. 103158.-14
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
15
38IPZD. 103158.-15
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
16
38IPZD. 103158.-16
1
23, Caller ID, DTMF, Loop Start
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground, MD
17
38IPZD.103412.1.MD TLI 410-306-8845
1
23, Caller ID, DTMF, Loop Start
LAB LCMC CECOM 6010 APG MD

10.3.2. ISDN PRI Trunks, Edgewood Area.

#
ISDN PRI Circuit ID
D-Channel
B Channels & Signaling
Demarcation
1
38IPZD330506.001
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG
2
38IPZD330506.002
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG
3
38IPZD330506.003
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG
4
38IPZD330506.004
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG
5
38IPZD330506.005
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG
6
38IPZD330506.006
1
23, DTMF, Caller ID, Hunting, Loop Start
E5103, Bond Road APG

10.4 Foreign Exchange (FX) Trunks. Not applicable.

10.5 Transport Channels. Not Applicable.

10.6 Data Point-to-Point Circuits.

#
Circuit ID/Name
Rate (Kbps)
A_Location
Z_Location
Description
1
38.HCGA.898029..CD
1.544
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
775 Priestford Rd, Churchville, Md 21028
USAG APG CK/BN 410J100001201
2
38.RTNJ.306173..CM.
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
Bldg 10301, Rd, Churchville, MD
ATC
3
38.RTNJ.306174..CM
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
Bldg 10301, Rd, Churchville, MD
ATC
4
38.RTNJ.321359..CM
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
Bldg 10301, Rd, Churchville, MD
ATC
5
38.LADA.100290..MD
2-wire
1122 Edgewood Road, Edgewood, MD 21040
1601 Hanson Road, Edgewood, MD 21040
DPW, Van Bibber Water Treatment Plant and Hanson Reservoir.

10.7 OPX Lines, Aberdeen Area

#
Circuit ID/Name
Type
Rate (Kbps)
A_Location
Z_Location
Circuit Description
1
38.OSNJ.306157..CM
PBX station line extended signaling OPX Line 278-7013
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
7 Plumb Point Loop West, Aberdeen Proving Ground, MD
Connection of circuit to customer provided equipment
2
38.OSNJ.306479..CM
Extended line connection off premise
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
BLDG 10306 Churchville Road, Aberdeen, Md
Connection of circuit to customer provided equipment
3
38.OSNJ.306480..CM
Extended line connection off premise
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
BLDG 10306 Churchville Road, Aberdeen, Md
Connection of circuit to customer provided equipment
4
38.OSNJ.306481..CM
Extended line connection off premise
Voice Grade
Bldg 311, Longs Corner Rd, Aberdeen Proving Ground
BLDG 10306 Churchville Road, Aberdeen, Md
Connection of circuit to customer provided equipment
5
56OSNP143
Circuit connection OPX Line
Voice Grade
775 Priestford Road, Churchville, MD
Churchville Test Area, Bldg 10301, Churchville, MD
Line extended
6
38.OSNJ.259962..CM
Extended line connection-off premises OPX 278-4199
Voice Grade
775 Priestford Road, Churchville, MD
Bldg 10301, Rd, Churchville, MD
Extended line connection-off premises
7
38.OSNJ.259964..CM
Ext. line connection-off premises OPX 278-4399
Voice Grade
775 Priestford Road, Churchville, MD
Bldg 10301, Rd, Churchville, MD
Extended line connection-off premises
8
38.RTNJ.321359..CM
Extended line connection-off premises ADT(Alarm Circuit)
Voice Grade
775 Priestford Road, Churchville, MD
Bldg 10301, Rd, Churchville, MD
US Army Corps of Engineers
9
55MS58