Drawing_W91QVN18R0250.pdf

PDF 486 KB Posted

Attached to
Install Windows, Building 2409
Solicitation number
W91QVN18R0250
Issued by

About this file

DRAWING

View the file

Other files

File Type Posted
Dutch_Door_Drawing.PDF PDF
Amendment_W91QVN-18-R-0250-0001.pdf PDF
Submittal_Register_W91QVN18R0250.pdf PDF
W91QVN-18-R-0250.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-1

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

2.

3.

4.

5.

6.

7.

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER.

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT, THE GENERAL

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE.

APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION

DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.

CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW

GENERAL NOTES

FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.

A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,

SOLIDS) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR WILL PROVIDE

COATINGS WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE

THE CONTRACTOR IS REQUIRED TO USE "LEAD FREE" COATINGS (LIQUID PAINTS OR

DOCUMENTATION TO 8 CES/CEAN.

THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL

ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).

PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN

AREA WILL NEED TO BE RESURVEYED AND ASBESTOS MATERIALS SHOULD BE REMOVED

WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK

ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE

IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: HOWEVER, IF SUSPECTED

VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS

WILL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER

PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR

THE CONTRACTOR IS REQUIRED TO USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1

UP

CORRIDOR-2

ELEV

B/B

TOILET

WOMEN

TOILET

MEN

JAN

STAIR -1

CONFERENCE ROOM

212CABINET

FILE

A/V

BREAK ROOM

COMM

STAIR-2

STAIR -3

CORRIDOR-1

HALL

CORRIDOR-3

FEC

FEC

207a

CLOSET

ELEC

TOILET

WOMEN

TOILET

MEN

CLOSET

SLOPE

3/12

S L

O P

E

DS

DS

DS

DS

FED OFFICE

213-1 CHIEF

411 CSB

OFFICE

411 CSB

MEETING ROOM

411 CSB

SIPR ROOM

411 CSB

215-1

BREAK ROOM

411 CSB

214-1

FILE CABINET

FED

OFFICE

BO & I CHIEF

W3 W1 W2 W1

,9

,0

,5

61,000

15,3007,5857,6157,6007,6007,6007,700

SCALE: 1/100

9.

NCOIC OFFICE

ADMIN STAFF

OFFICE

DIRECTOR

OFFICE

S /S

CAMP CASEY

INSTALL WINDOWS FOR BLDG S-2409

YI, SC

196558

AND GENERAL NOTES

2ND FLOOR PLAN

2ND FLOOR PLAN @ BLDG S-2409

A-2

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

CAMP CASEY

INSTALL WINDOWS FOR BLDG S-2409

YI, SC

196558

DN

B/B

409a

CORRIDOR-1

ENGINEERING

CHIEF OFFICE

PM

& ADMIN

OFFICE

ELEV

CONTROL RM

WOMEN

TOILET

MEN

TOILET

JAN

COMM

ELEV

CIO OFFICE

CIO CHIEF

OFFICE

STAIR -3

STAIR -1

STAIR-2

DESIGN CHIEF

OFFICE

DESIGN OPEN

OFFICE

407 418

CIO

STORAGE

HALL

CORRIDOR-3

ELEC

CLOSET

ROOM

BREAK

ROOM

FEC

FEC

COFERENCE

ROOM

S /S

ENERGY

61,000

15,3007,5857,6157,6007,6007,6007,700

,9

,0

,5

W1W1

SCALE: 1/100

4TH FLOOR PLAN

4TH FLOOR PLAN @ BLDG S-2409

A-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCOPE OF WORKS (ARCHITECTURAL WORKS)

1.

2.

3.

REMARKS

WIDTH

MATERIAL

TYPENOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAME

2.

3.

5.

4.

HEAT GAIN AND FIRERATED.

WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE

BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE

WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL

1.

INSECT SCREEN SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.

HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.

& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD INSTALL

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

10001600ALGLASSA - -------W1

( SHGC : MAX 0.4 )

+ 6 THK TINTED LOW-E TEMPERED GLASS

+ 12 THK AIR SPACE

: 8.75 THK CLEAR LAMINATED GLASS

TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS

VERIFY BY BLAST WINDOW MFR

4.

WINDOW SCHEDULE

WINDOW ELEVATIONS

FIN FL

(ANODIZED DARK BRONZE)

AL BLAST WINDOW

(THERMAL BREAK TYPE)

W/ INSECT SCREEN

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

A

5.

FIN FL

(ANODIZED DARK BRONZE)

AL BLAST WINDOW

(THERMAL BREAK TYPE)

W/ INSECT SCREEN

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

B

WINDOW WINDOW

WINDOW

WINDOW DIMENSION

10001300ALGLASSA - -------W2 VERIFY BY BLAST WINDOW MFR

1000600ALGLASSB - -------W3 VERIFY BY BLAST WINDOW MFR

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

WINDOW NOTES

CAMP CASEY

INSTALL WINDOWS FOR BLDG S-2409

YI, SC

196558

INSTALL WINDOW HORIZONTAL MINI BLINDS WITH NEWS, FIREPROOF TYPE IN RM NO 215.

AS SHOWN ON FLOOR PLAN AND WINDOW SCHEDULE.

REPLACE GWB INCLUDING METAL STUDS AND CORNER BEAD AROUND WINDOWS IN RM NO 215

WINDOW SCHEDULE.

PAINT ON GWB WALL AROUND WINDOWS IN RM NO 215 AS SHOWN ON FLOOR PLAN AND

AND SCOPE OF WORKS

WINDOW SCHEDULE, ELEVATIONS, NOTES

FIXED AND TILTING FIXED AND TILTING

METAL FLASHING IN RM NO 215 AS SHOWN ON FLOOR PLAN AND WINDOW SCHEDULE.

REFINISH EIFS OF EXTERIOR WALL AROUND WINDOW OPENINGS INCLUDING INSTALL PROTECTED

SCHEDULE.

GLASS ( SHGC : MAX 0.4 ) IN RM NO. 215 AS SHOWN ON FLOOR PLAN AND WINDOW

CLEAR LAMINATED GLASS + 12 THK AIR SPACE + 6 THK TINTED LOW-E TEMPERED

INSTALL NEW ALUMINUM THERMAL BREAKER TYPE BLAST WINDOWS INCLUDING 8.75 THK

CONSTRUCTION (L) WORKS

196558-Install windows for bldg 2409, CP Casey-A-1
196558-Install windows for bldg 2409, CP Casey-A-2
196558-Install windows for bldg 2409, CP Casey-A-3

File details come from the government source that posted it.