CIVIL/OPS/ENVIRONMENTAL BR
ATTN: LOGAN BARRETT
600 DR M L KING JR PL, RM 821
LOUISVILLE KY 40202-2236
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Solicitation W912QR20Q0061 to provide Bolts, nuts and Washers to McAlpine Locks and Dam is hereby amended as follow s:
a. The Scope of w ork has been modified w ith additional language. Changes have been highlighted in yellow .
b. All other terms and conditions remain unchanged.
SEE SUMMARY OF CHANGES
1. CONTRACT ID CODE PAGE OF PAGES
1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912QR20Q0061
X 9B. DATED (SEE ITEM 11)
23-Apr-2020
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
U0001
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
28-Apr-2020
CODE
U. S. ARMY ENGINEER DISTRICT, LOUISVILLE
600 DR. MARTIN LUTHER KING, JR. PLACE
ROOM 821
LOUISVILLE KY 40202-2239
W912QR 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE 964860
FACILITY CODECODE
EMAIL:TEL:
W912QR20Q0061
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
The following have been modified:
SCOPE OF WORK
Ohio River McAlpine Locks and Dam Gate Replacement Project
Bolts, Nuts, Washers
1. GENERAL:
1.1 Scope of Work: The Contractor shall provide all labor, equipment, and materials to perform all operations necessary to provide the bolts, nuts, and washers per the specs and attached drawings.
All work is to be completed in accordance with these specifications, referenced drawings, Industry Standards and any and all applicable codes, regulations and ordinances. This includes but is not limited to the machining, Quality Control Testing and Acceptance, part identification and packaging. The Contractor shall package all items as indicated in these Specifications and deliver all the completed parts and assemblies to the Louisville Repair Station.
1.2 Start/Completion Dates: The Contractor shall begin work within 10 days of the Notice of Award.
All the bolts, nuts, and washers shall be delivered by 15 June 2020.
1.3 Technical Representative: All technical questions regarding this contract shall be directed to Logan Barrett: (502) 315-6872, email: Logan.D.Barrett@usace.army.mil.
1.4 Safety: The Contractor shall complete all work in accordance with the U.S. Army Corps of Engineers Safety and Health Requirements Manual, EM 385-1-1, and all applicable Federal, State and local laws, codes and regulations.
1.5 Delivery/Packaging: The contractor shall deliver all items to the Louisville Repair Station. The contractor shall contact Louisville Repair Station via phone number (502) 515-3079 prior to delivery to schedule unloading. The address to the Louisville Repair Station is 2605 Shippingport Drive, Louisville, KY 40212. The parts must be packaged in wood crates or wood boxes to ensure the safety of the parts during shipping. Further protection measures shall be taken to prevent damage to adjusting bolt threads
2. REFERENCES
1.1 All Bolts, nuts, washers must meet the following standards when relevant:
ASTM F436 - Standard Specification for Hardened Steel Washers Inch and Metric Dimesnions
ASTM A193 - Standard Specification for Alloy-Steel and Stainless Steel Bolting for High Temperature or High Pressure Service or Other Special Purposes Applications
SAE J429 - Mechanical and Material Requirements for Externally Threaded Fasteners
W912QR20Q0061
**Amendment 0001**
LINE ITEM 0001:
Miter/Quoin Adjustment Bolts – Machined screws fully threaded (rolled threads), hex socket heads Specification: 3/4” diameter x 10” length, 2A, 10 UNC Material: Grade 2
LINE ITEM 0002:
Miter/Quoin Holding Bolts – Machined screws threaded 8 inches (rolled threads), hex socket heads Specification: 3/4” diameter x 14” length, 2A, 10 UNC Material: Grade 8
LINE ITEM 0003:
Heavy Hex Head Nut – 3/4” diameter. 2B, 10 UNC Material: Grade 8
LINE ITEM 0004:
Hardened structural steel washer – 3/4” ID
LINE ITEM 0005:
Embedded Quoin Adjusting Bolts Specification: 1/2" diameter x 1 1/2" length - 20 UNF 2A threaded full length Material: ASTM A 193 Grade B8
LINE ITEM 0006:
Embedded Quoin Holding Bolts Specification: 1/2" diameter x 2" Length - 20 UNF 2A threaded full length Material: ASTM A 193 Grade B8
LINE ITEM 0007:
Washer – 1/2” ID, 1” OD Material: ASTM A 193 Grade B8