Conformed-AMDT0003-PN92793-SOF-OperationsBldg-Tech-Summary-Changes.pdf

PDF 2 MB Posted

Attached to
PN92793 - JSOC OPERATIONS FACILITY ANNEX Federal contract opportunity
Solicitation number
W912PM23R0003
Issued by
Department of the Army Corps of Engineers Engineering District Wilmington

About this file

This document provides details for a federal construction solicitation and the related project opportunity. The solicitation seeks construction services for a Special Operations Forces Operations Facility Annex at Fort Bragg, North Carolina. Services include construction of administrative areas, storage facilities, latrines, showers, laundry rooms, a sensitive compartmented information facility with offices and meeting spaces. The project also requires installation of security, communication, and utility systems. Sustainable design and low impact development features must be incorporated. The solicitation is issued by the Department of the Army Corps of Engineers Wilmington District for work to be completed at Fort Bragg. The amended solicitation documents provide revised drawings and remove classification markings.

View the file

Other files for this federal contract opportunity

Other files attached to PN92793 - JSOC OPERATIONS FACILITY ANNEX, newest first.
File Type Posted
W912PM23R0003-0005 Conformed PN92793.pdf PDF
W912PM23R0003-0005 SF30 PN92793.pdf PDF
Conformed-AMDT0005-PN92793-SOF-OperationsBldg-Tech-Summary-Changes.pdf PDF
W912PM23R0003-0004 SF30 PN92793.pdf PDF
W912PM23R0003-0004 Conformed PN92793.pdf PDF
PN 92793 Site Visit Sign-In Sheet.pdf PDF
W912PM23R0003-0003 SF30 PN92793.pdf PDF
W912PM23R0003-0003 Conformed PN92793.pdf PDF
W912PM23R0003-0002 PN92793 Conformed.pdf PDF
USACE-SAW_PN92793 - RTA - VOLUME II (UnLocked).pdf PDF
USACE-SAW_PN92793 - RTA - VOLUME I (UnLocked).pdf PDF
PN92793_-_READY_TO_ADVERTISE_-_geotechnical_report.pdf PDF
W912PM23R0003-0002 PN92793.pdf PDF
W912PM23R0003-0001 PN92793.pdf PDF
Attachment 2 - Corporate Relevant Specialized Experience Template.pdf PDF
PN92793 - READY TO ADVERTISE - SPECIFICATIONS-VOL II.pdf PDF
PN92793-RTA-FF and E Specifications-VOL III.pdf PDF
W912PM23R0003 PN92793 Construct JSOC Ops Fac Annex.pdf PDF
USACE-SAW_PN92793 - RTA - VOLUME I (Locked).pdf PDF
Attachment 4 - Small Business Participation Plan.pdf PDF
PN92793 - READY TO ADVERTISE - SPECIFICATIONS-VOL I.pdf PDF
USACE-SAW_PN92793 - RTA - VOLUME II (Locked).pdf PDF
Attachment 1 - Proposal Data Sheet.pdf PDF
Attachment 3 - NAVFAC-USACE PPQ (fillable).pdf PDF
Attachment 3 - NAVFAC-USACE PPQ instruction and RFP language.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation # W912PM23R0003 Date: 07-February-2023 Project Title – PN92793, Construct JSOC Operations Facility Annex, Ft. Bragg, NC Amendment No. 0003

SUMMARY OF CHANGES

1. CHANGES TO SPECIFICATIONS. None

2. CHANGES TO DRAWINGS. Attached hereto are revised drawing sheets.

A. REVISED DRAWINGS (ISSUED).

G-001, COVER SHEET, VOLUME I

o Revised by Amendment 0003. Removed CUI markings.

G-001, COVER SHEET, VOLUME II

o Revised by Amendment 0003. Removed CUI markings.

M-401, Enlarged Plan – Mechanical Room 106 o Revised by Amendment 0003. Sheet Keynote, 10.

…end of summary…

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

R E

A D

Y T

O A

D V

E R

T

IS

E

A E

C O

M S

E R

V

IC

E S

IN

C

S

J E

F F

E R

S O

N S

T S

T E

R O

A N

O K

E V

A

M J O

N E

S

W -P

M -D

/1

/2

-F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A

S O

F O

P E

R A

T

IO

N S

A N

N E

X B

U

IL

D

IN

G

P N

W

IL

M

IN

G T

O N

D

IS

T R

IC

T

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

S E A L

S

IG

N A

TU

R E

P

LA

C E H O

LD

E

RDELIVERY ORDER NO.: W912PM20F0013

G-001

C O

V E

R S

H E

E T

T M

C A

L L

IS

T E

R

T M

C A

L L

IS

T E

R

K G

U

IL

F O

Y L E

W912PM-19-D-0003

09/15/22

I

FORT BRAGG, NC

SOF OPERATIONS ANNEX BUILDING

60625564

PN 92793, FY 2022

R

E V

IS

E

D P

E R

A M

N D

F

E B

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

R E

A D

Y T

O A

D V

E R

T

IS

E

A E

C O

M S

E R

V

IC

E S

IN

C

S

J E

F F

E R

S O

N S

T S

T E

R O

A N

O K

E V

A

M J O

N E

S

W -P

M -D

/1

/2

-F

IL

E N

A M

E

C A

T E

G O

R Y

C O

D E

F O

R T

B R

A G

G N

O R

T H

C A

R O

L

IN

A

S O

F O

P E

R A

T

IO

N S

A N

N E

X B

U

IL

D

IN

G

P N

W

IL

M

IN

G T

O N

D

IS

T R

IC

T

W

IL

M

IN

G T

O N

N

O R

T H

C A

R O

L

IN

A

S E A L

S

IG

N A

TU

R E

P

LA

C E H O

LD

E

RDELIVERY ORDER NO.: W912PM20F0013

G-001

C O

V E

R S

H E

E T

T M

C A

L L

IS

T E

R

T M

C A

L L

IS

T E

R

K G

U

IL

F O

Y L E

W912PM-19-D-0003

09/15/22

II

FORT BRAGG, NC

SOF OPERATIONS ANNEX BUILDING

60625564

PN 92793, FY 2022

R

E V

IS

E

D P

E R

A M

N D

F

E B

C.6 D

2.4

2.2

C1 M-302

EF-02

UH-01

MECHANICAL

ROOM

EF-01

x2

R

A

22x16 EA

12x12 EA x1

EA

32x20Ɵ SA

20x14 EA x1

EA

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

R S/

R L

12x12 EA

20x20 EAC13 M-302

MD

MD

36x20 RA

SP

SP

SP

4' 2' 0 4' 8' 1/4"=1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

P S

O F

EN

G

IN

E

ER

S

D R

AW

N

B Y:

D

ES

IG

N

E D

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

A C

T N

O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

GRAPHIC SCALES

R

EA

D Y

TO

A

D

VE

R

TI

SE

AE

C

O M

S

ER

VI

C

ES

, I

N C

S . J

EF

FE

R

SO

N S

T

ST

E

R

O A

N O

KE

, V

A

M . J

O N

ES

W

2-

PM

-D

/1

5/

-FI

LE

N

AM

E:

C

AT

EG

O

R Y

C O

D E

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

O P

ER

AT

IO

N

S A

N N

E X

BU

IL

D

IN

G

PN

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

W

IL

M

IN

G

TO

N , N

O R

TH

C

A R

O

LI

N A

M-401

EN

LA

R G

ED

P

LA

N

M

EC

H

R O

O M

D .A

LL

EN

M . M

AR

KL

AN

D

C . W

IT

T

W

8-

XX

-X

-X

XX

X

1/4" = 1'-0"B1 ENLARGED PLAN - MECH ROOM 106 B9 ISOMETRIC - SOUTHEAST - MECH RM 106

SHEET KEYNOTES

1 COVER OPENING WITH WIRE MESH SCREEN.

2 30X20 RETURN DUCT UP TO FLOOR ABOVE. INSTALL FIRE

DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE. SEE

SHEET MH102A FOR CONTINUATION.

3 30x20 RETURN DUCT DOWN FROM FLOOR ABOVE. INSTALL FIRE

DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.

4 14x12 EXHAUST DUCT DOWN FROM FLOOR ABOVE. INSTALL

FIRE DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.

5 28x18 OVAL SUPPLY DUCT UP TO FLOOR ABOVE. INSTALL FIRE

DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.

6 PROVIDE 12" OF STRAIGHT DUCT EQUAL TO FULL SIZE OF

LOUVER. PROVIDE MOTORIZED DAMPER TO OPEN WHEN EF-2 IS

ACTIVATED.

7 ROUTE EXHAUST DUCT TO EXHAUST LOUVER. TRANSITION

DUCT TO MATCH FULL SIZE OF LOUVER

8 INSTALL BLANK-OFF PANEL FOR UNUSED PORTION OF LOUVER.

9 DIFFERENTIAL PRESSURE SENSOR.

10 DDC CONTROL PANEL

GENERAL NOTES THIS SHEET

A. REFER TO SHEET M-001 FOR MECHANICAL LEGEND AND GENERAL NOTES.

B. CONTRACTOR SHALL ENSURE THE BOTTOM OF THE VAV BOXES ARE A MINIMUM

OF 6" ABOVE CEILING GRID TO PROVIDE THE REQUIRED SERVICE CLEARANCE,

AND A MAXIMUM OF 24" ABOVE CEILING GRID TO MAINTAIN ACCESSIBILITY.

ADDITIONALLY, CONTRACTOR MUST MAINTAIN SERVICE CLEARANCE ON

CONTROL SIDE OF VAV BOX AS INDICATED.

R

E

VI

SE

D

P

ER

A M

N D

FE

B

COVER SHEET - VOLUME I.pdf
Sheets
G-001 - COVER SHEET
COVER SHEET - VOLUME II.pdf
Sheets
G-001 - COVER SHEET

File details come from the government source that posted it. Updated .