This document provides details for a federal construction solicitation and the related project opportunity. The solicitation seeks construction services for a Special Operations Forces Operations Facility Annex at Fort Bragg, North Carolina. Services include construction of administrative areas, storage facilities, latrines, showers, laundry rooms, a sensitive compartmented information facility with offices and meeting spaces. The project also requires installation of security, communication, and utility systems. Sustainable design and low impact development features must be incorporated. The solicitation is issued by the Department of the Army Corps of Engineers Wilmington District for work to be completed at Fort Bragg. The amended solicitation documents provide revised drawings and remove classification markings.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation # W912PM23R0003 Date: 07-February-2023 Project Title – PN92793, Construct JSOC Operations Facility Annex, Ft. Bragg, NC Amendment No. 0003
SUMMARY OF CHANGES
1. CHANGES TO SPECIFICATIONS. None
2. CHANGES TO DRAWINGS. Attached hereto are revised drawing sheets.
A. REVISED DRAWINGS (ISSUED).
G-001, COVER SHEET, VOLUME I
o Revised by Amendment 0003. Removed CUI markings.
G-001, COVER SHEET, VOLUME II
o Revised by Amendment 0003. Removed CUI markings.
M-401, Enlarged Plan – Mechanical Room 106 o Revised by Amendment 0003. Sheet Keynote, 10.
…end of summary…
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S E A L
S
IG
N A
TU
R E
P
LA
C E H O
LD
E
RDELIVERY ORDER NO.: W912PM20F0013
G-001
C O
V E
R S
H E
E T
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L E
W912PM-19-D-0003
09/15/22
I
FORT BRAGG, NC
SOF OPERATIONS ANNEX BUILDING
60625564
PN 92793, FY 2022
R
E V
IS
E
D P
E R
A M
N D
F
E B
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S E A L
S
IG
N A
TU
R E
P
LA
C E H O
LD
E
RDELIVERY ORDER NO.: W912PM20F0013
G-001
C O
V E
R S
H E
E T
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L E
W912PM-19-D-0003
09/15/22
II
FORT BRAGG, NC
SOF OPERATIONS ANNEX BUILDING
60625564
PN 92793, FY 2022
R
E V
IS
E
D P
E R
A M
N D
F
E B
C.6 D
2.4
2.2
C1 M-302
EF-02
UH-01
MECHANICAL
ROOM
EF-01
x2
R
A
22x16 EA
12x12 EA x1
EA
32x20Ɵ SA
20x14 EA x1
EA
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
R S/
R L
12x12 EA
20x20 EAC13 M-302
MD
MD
36x20 RA
SP
SP
SP
4' 2' 0 4' 8' 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
P S
O F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
GRAPHIC SCALES
R
EA
D Y
TO
A
D
VE
R
TI
SE
AE
C
O M
S
ER
VI
C
ES
, I
N C
S . J
EF
FE
R
SO
N S
T
ST
E
R
O A
N O
KE
, V
A
M . J
O N
ES
W
2-
PM
-D
/1
5/
-FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O P
ER
AT
IO
N
S A
N N
E X
BU
IL
D
IN
G
PN
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
A R
O
LI
N A
M-401
EN
LA
R G
ED
P
LA
N
M
EC
H
R O
O M
D .A
LL
EN
M . M
AR
KL
AN
D
C . W
IT
T
W
8-
XX
-X
-X
XX
X
1/4" = 1'-0"B1 ENLARGED PLAN - MECH ROOM 106 B9 ISOMETRIC - SOUTHEAST - MECH RM 106
SHEET KEYNOTES
1 COVER OPENING WITH WIRE MESH SCREEN.
2 30X20 RETURN DUCT UP TO FLOOR ABOVE. INSTALL FIRE
DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE. SEE
SHEET MH102A FOR CONTINUATION.
3 30x20 RETURN DUCT DOWN FROM FLOOR ABOVE. INSTALL FIRE
DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.
4 14x12 EXHAUST DUCT DOWN FROM FLOOR ABOVE. INSTALL
FIRE DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.
5 28x18 OVAL SUPPLY DUCT UP TO FLOOR ABOVE. INSTALL FIRE
DAMPER WHERE DUCT PENETRATES FLOOR SLAB ABOVE.
6 PROVIDE 12" OF STRAIGHT DUCT EQUAL TO FULL SIZE OF
LOUVER. PROVIDE MOTORIZED DAMPER TO OPEN WHEN EF-2 IS
ACTIVATED.
7 ROUTE EXHAUST DUCT TO EXHAUST LOUVER. TRANSITION
DUCT TO MATCH FULL SIZE OF LOUVER
8 INSTALL BLANK-OFF PANEL FOR UNUSED PORTION OF LOUVER.
9 DIFFERENTIAL PRESSURE SENSOR.
10 DDC CONTROL PANEL
GENERAL NOTES THIS SHEET
A. REFER TO SHEET M-001 FOR MECHANICAL LEGEND AND GENERAL NOTES.
B. CONTRACTOR SHALL ENSURE THE BOTTOM OF THE VAV BOXES ARE A MINIMUM
OF 6" ABOVE CEILING GRID TO PROVIDE THE REQUIRED SERVICE CLEARANCE,
AND A MAXIMUM OF 24" ABOVE CEILING GRID TO MAINTAIN ACCESSIBILITY.
ADDITIONALLY, CONTRACTOR MUST MAINTAIN SERVICE CLEARANCE ON
CONTROL SIDE OF VAV BOX AS INDICATED.
R
E
VI
SE
D
P
ER
A M
N D
FE
B
| COVER SHEET - VOLUME I.pdf |
| Sheets |
| G-001 - COVER SHEET |
| COVER SHEET - VOLUME II.pdf |