USACE-SAW_PN92793 - RTA - VOLUME I (Locked).pdf
PDF 48 MB Posted
- Attached to
- PN92793 - JSOC OPERATIONS FACILITY ANNEX Federal contract opportunity
- Solicitation number
- W912PM23R0003
About this file
This document provides details for a federal contract solicitation. The solicitation number is W912PM23R0003 and is for the construction of a Special Operations Forces Operations Facility Annex at Joint Special Operations Command. The project scope includes administrative areas, caged storage with roll up doors, latrines and showers with lockers, laundry facilities, a sensitive compartmented information facility with administrative and collaboration spaces, as well as utilities including a fire alarm and mass notification system, fire suppression, communications networks, an intercom system, surveillance, electronic access control, cable TV, and connection to an energy management control system. Low impact development features and compliance with federal laws and executive orders for high performance and sustainable building are also requirements. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Wilmington.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FI
LE
N
AM
E:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SU
BM
IT
TE
D B
Y:
D
AT
E
C H
EC
KE
D B
Y:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
US Army Corps of Engineers
SI
ZE
"x
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
G-000
C O
VE
R
S H
EE
T
US Army Corps of Engineers ®
Wilmington District
S.
SU
R R
AT
T
S.
SU
R R
AT
T
J.
M
AN
N
IN
G
Aw d_
C ov er .d w g
C O
N
TR
AC
T
N O
D R
AW
IN
G C
O D
E:
SO
LI
C
IT
AT
IO
N N
O
W
2P M
R
AW
AR
D D
AT
E:
TD
B
W
2P M
XX
XX
A.
FE
LI
C
IA
N
O -G
R
AN
D A
PN92793 CONSTRUCT JSOC OPERATIONS FACILITY ANNEX
FORT BRAGG, NORTH CAROLINA
RTA SET
CONTRACT NO.:
SOLICITATION NO:
AWARD DATE:
W912PM23XXXX
W912PM23R0003
TBD
PN
C O
N
ST
R U
C T
JS
O
C O
PE
R
AT
IO
N S
FA
C
IL
IT
Y
AN
N
EX
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
R
TA
S
ET
VOLUME I
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S
EA
L S
IG
N A
TU
R E
PLA
C
EH
O
LD
E R
CONTROLLED BY: JSOC
CONTROLLED BY: USACE SAW
CUI CATEGORY: CONTRACT
DISTRIBUTION STATEMENT D
POC: USACE FOIA (FOIA-SAW@USACE.ARMY.MIL)
DELIVERY ORDER NO.: W912PM20F0013
G-001
C O
V E
R S
H E
E T
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L E
W912PM-19-D-0003
09/15/22
I
FORT BRAGG, NC
SOF OPERATIONS ANNEX BUILDING
60625564
PN 92793, FY 2022
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S
EA
L S
IG
N A
TU
R E
PLA
C
EH
O
LD
E R
G-002.1
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
I
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L E
INDEX OF DRAWINGS - VOLUME I
SHEET ID SHEET TITLE
A-302 BUILDING SECTIONS
A-303 WALL SECTION
A-304 WALL SECTION
A-305 WALL SECTION
A-306 WALL SECTION
A-307 WALL SECTION
A-308 WALL SECTION
A-309 WALL SECTION
A-310 WALL SECTION
A-311 WALL SECTION
A-401 STAIR PLANS AND SECTIONS
A-402 STAIR PLANS AND SECTIONS
A-403 STAIR PLANS AND SECTIONS
A-404 ELEVATOR PLANS AND SECTIONS
A-405 ENLARGED RESTROOM PLANS & ELEVATIONS
A-406 ENLARGED LOCKER ROOM PLANS & ELEVATIONS
A-407 ENLARGED ROOM PLANS & DETAILS
A-410 FIRST FLOOR ACCESS FLOOR PLAN & DETAILS
A-411 SECOND FLOOR ACCESS FLOOR PLAN & DETAILS
A-501 EXTERIOR BASE DETAILS
A-502 EXTERIOR DETAILS
A-503 ROOF DETAILS
A-504 ROOF DETAILS
A-505 ROOF DETAILS
A-506 ENTRANCE CANOPY DETAILS
A-507 INTERIOR DETAILS
A-510 STAIR & RAILING DETAILS
A-511 STAIR & RAILING DETAILS
A-520 CEILING DETAILS
A-530 CASEWORK DETAILS
A-601 PARTITION TYPES
A-602 DOOR SCHEDULE
A-610 DOOR DETAILS
A-611 CURTAINWALL DETAILS
A-620 OPERABLE PARTITION DETAILS
A-621 EXTERIOR WINDOW AND LOUVER ELEVATIONS
A-622 WINDOW DETAILS
A-701 CAGE DETAILS
A-702 CAGE DETAILS
A-801 AIR BARRIER - FIRST FLOOR PLAN
A-802 AIR BARRIER - SECOND FLOOR PLAN
A-803 AIR BARRIER - BUILDING SECTIONS
A-804 AIR BARRIER - BUILDING SECTIONS
INTERIORS
IN101 FIRST FLOOR FINISH PLAN - COMPOSITE
IN101A FIRST FLOOR FINISH PLAN - AREA A
IN101B FIRST FLOOR FINISH PLAN - AREA B
IN102A SECOND FLOOR FINISH PLAN - AREA A
IN501 FLOORING TRANSITION DETAILS
IN601 FINISH LEGEND AND ROOM FINISH SCHEDULE
IF101 FIRST FLOOR FURNITURE PLAN - COMPOSITE
IF101A FIRST FLOOR FURNITURE PLAN - AREA A
IF101B FIRST FLOOR FURNITURE PLANS - AREA B
IF102A SECOND FLOOR FURNITURE PLAN - AREA A
IF601 FURNITURE SCHEDULES
IG101 FIRST FLOOR SIGNAGE PLAN - COMPOSITE
IG101A FIRST FLOOR SIGNAGE PLAN - AREA A
IG101B FIRST FLOOR SIGNAGE PLAN - AREA B
IG102A SECOND FLOOR SIGNAGE PLAN - AREA A
IG601 SIGNAGE SCHEDULE
IG602 SIGNAGE DETAILS
INDEX OF DRAWINGS - VOLUME I
SHEET ID SHEET TITLE
GENERAL
G-001 COVER SHEET
G-002.1 INDEX OF DRAWINGS - VOLUME I
G-002.2 INDEX OF DRAWINGS - VOLUME II
G-003 ABBREVIATIONS
G-004 HAUL ROUTES AND VICINITY MAP
G-005 FORT BRAGG CANTONMENT
GENERAL INFORMATION
GI001 BUILDING & LIFE SAFETY CODE ANALYSIS
GI002 LIFE SAFETY OCCUPANT LOAD SCHEDULES
GI101 FIRST FLOOR LIFE SAFETY PLAN
GI102 SECOND FLOOR LIFE SAFETY PLAN
CIVIL
C-001 CIVIL NOTES AND LEGENDS
CE101 EXISTING CONDITIONS PLAN
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CS503 SITE DETAILS
CU101 UTILITY PLAN
CU201 UTILITY PROFILES
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CU503 UTILITY DETAILS
CU504 UTILITY DETAILS
CU505 UTILITY DETAILS
CU506 UTILITY DETAILS
CU507 UTILITY DETAILS
CG101 GRADING AND DRAINAGE PLAN
CG501 STORM DRAINAGE DETAILS
CG502 STORM DRAINAGE DETAILS
CG503 STORM DRAINAGE DETAILS
CG504 STORM DRAINAGE DETAILS
CG505 STORM DRAIN DETAILS
CG506 STORM DRAIN DETAILS
CG701 EROSION AND SEDIMENT CONTROL PLAN (INITIAL)
CG702 EROSION AND SEDIMENT CONTROL PLAN (FINAL)
CG711 PRE-DEVELOP DRAINAGE MAP
CG712 POST-DEVELOP DRAINAGE MAP
CG801 ERIOSION AND SEDIMENT CONTROL PLAN NOTES
CG802 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG803 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG804 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG805 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG806 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG807 EROSION AND SEDIMENT CONTROL PLAN DETAILS
CG808 EROSION AND SEDIMENT CONTROL PLAN DETAILS
LANDSCAPE
LP101 LANDSCAPE PLAN
LP102 PLANTING DETAILS
LP103 PLANTING SCHEDULE
STRUCTURAL
S-001 GENERAL NOTES
S-002 COMPONENT AND CLADDING DIAGRAM
S-101 FOUNDATION PLAN - OVERALL
S-101A FOUNDATION PLAN - AREA A
S-101B FOUNDATION PLAN - AREA B
S-102 SECOND FLOOR AND LOW ROOF FRAMING PLAN - OVERALL
S-102A SECOND FLOOR FRAMNG PLAN - AREA A
S-102B LOW ROOF FRAMING PLAN - AREA B
S-103 ROOF FRAMING PLAN
S-205 STEEL ELEVATIONS
S-301 FOUNDATION SECTIONS & DETAILS
S-305 FRAMING SECTIONS & DETAILS
S-306 FRAMING SECTIONS & DETAILS
S-307 FRAMING SECTIONS & DETAILS
S-308 FRAMING SECTIONS & DETAILS
S-309 FRAMING SECTIONS & DETAILS
S-401 ENLARGED PLANS
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
S-503 TYPICAL DETAILS
S-504 TYPICAL DETAILS
S-505 TYPICAL DETAILS
S-601 SCHEDULES AND DETAILS
S-602 LOADING DIAGRAMS
S-603 TRUSS LOADING DIAGRAM
ARCHITECTURAL
A-001 GENERAL NOTES AND LEGENDS
A-100 SECURITY AND STC FLOOR PLANS
A-101 FIRST FLOOR PLAN - COMPOSITE
A-101A FIRST FLOOR PLAN - AREA A
A-101B FIRST FLOOR PLAN - AREA B
A-102 SECOND FLOOR PLAN - COMPOSITE
A-102A SECOND FLOOR PLAN - AREA A
A-103 ROOF PLAN - COMPOSITE
A-103A ROOF PLAN - AREA A
A-103B ROOF PLAN - AREA B
A-104A FIRST FLOOR DIMENSION PLAN - AREA A
A-104B FIRST FLOOR DIMENSION PLAN - AREA B
A-105A SECOND FLOOR DIMENSION PLAN - AREA A
A-111 FIRST FLOOR REFLECTED CEILING PLAN - COMPOSITE
A-111A FIRST FLOOR REFLECTED CEILING PLAN - AREA A
A-111B FIRST FLOOR REFLECTED CEILING PLAN - AREA B
A-112 SECOND FLOOR REFLECTED CEILING PLAN - AREA A
A-201 BUILDING ELEVATIONS
A-202 BUILDING ELEVATIONS
A-203 BUILDING ELEVATIONS
A-204 BUILDING ELEVATIONS
A-301 BUILDING SECTIONS
S
EA
L S
IG
N A
TU
R E
PLA
C
EH
O
LD
E R
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S E A L
S
IG
N A
TU
R E
P
LA
C E H O
LD
E R
G-002.2
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
I I
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L E
INDEX OF DRAWINGS - VOLUME II
SHEET ID SHEET TITLE
T-601 TELECOMMUNICATIONS GROUND RISER DIAGRAM
T-602 TELECOMMUNICATIONS PATHWAYS RISER DIAGRAM
T-603 TELECOMMUNICATIONS VOICE AND DATA RISER DIAGRAM
AUDIO VISUAL
TA001 AUDIO VISUAL GENERAL NOTES, SYMBOLS & ABBREVIATIONS
TA101A AUDIO VISUAL FIRST FLOOR PLAN - AREA A
TA101B AUDIO VISUAL FIRST FLOOR PLAN - AREA B
TA102A AUDIO VISUAL SECOND FLOOR PLAN - AREA A
TA111A AUDIO VISUAL FIRST FLOOR RCP - AREA A
TA111B AUDIO VISUAL FIRST FLOOR RCP - AREA B
TA112A AUDIO VISUAL SECOND FLOOR RCP - AREA A
TA401 AUDIO VISUAL ENLARGED PLANS
TA501 AUDIO VISUAL DETAILS
SECURITY
TY001 SECURITY GENERAL NOTES, SYMBOLS & ABBREVIATIONS
TY101A SECURITY FIRST FLOOR PLAN - AREA A
TY101B SECURITY FIRST FLOOR PLAN - AREA B
TY102A SECURITY SECOND FLOOR PLAN - AREA A
TY102B SECURITY SECOND FLOOR PLAN - AREA B
TY103A SECURITY ROOF PLAN - AREA A
TY501 SECURITY DETAILS
TY502 SECURITY DOOR DETAILS - 1 OF 2
TY503 SECURITY DOOR DETAILS - 2 OF 2
INDEX OF DRAWINGS - VOLUME II
SHEET ID SHEET TITLE
GENERAL
G-001 COVER SHEET
G-002.1 INDEX OF DRAWINGS - VOLUME I
G-002.2 INDEX OF DRAWINGS - VOLUME II
G-003 ABBREVIATIONS
G-004 HAUL ROUTES AND VICINITY MAP
G-005 FORT BRAGG CONTONMENT
FIRE PROTECTION
FA001 FIRE ALARM GENERAL NOTES & LEGEND
FA101 FIRST FLOOR FIRE ALARM / MNS PLAN
FA102 SECOND FLOOR FIRE ALARM / MNS PLAN
FA601 FIRE ALARM / MNS SEQUENCE OF OPERATIONS MATRIX
FA602 FIRE ALARM / MNS RISER DIAGRAM
FX001 FIRE SUPPRESSION GENERAL NOTES & LEGEND
FX101 FIRST FLOOR FIRE SUPPRESSION PLAN
FX102 SECOND FLOOR FIRE SUPPRESSION PLAN
FX501 FIRE SUPPRESSION DETAILS
PLUMBING
P-001 PLUMBING LEGEND & NOTES
PU100 UNDERGROUND PLAN - PLUMBING
PW101 FIRST FLOOR PLAN - DWV
PW102 SECOND FLOOR PLAN - DWV
PL101 FIRST FLOOR PLAN - SUPPLY
PL102 SECOND FLOOR PLAN - SUPPLY
P-401 ENLARGED PLANS
P-402 ENLARGED PLANS
P-501 PLUMBING DETAILS
P-601 PLUMBING SCHEDULES
P-701 PLUMBING RISER DIAGRAMS
MECHANICAL
M-001 MECHANICAL LEGEND AND GENERAL NOTES
MH101 MECHANICAL DUCTWORK PLAN - FIRST FLOOR - COMPREHENSIVE
MH101A MECHANICAL DUCTWORK PLAN - FIRST FLOOR - AREA A
MH101B MECHANICAL DUCTWORK PLAN - FIRST FLOOR - AREA B
MH102 MECHANICAL DUCTWORK PLAN - SECOND FLOOR - COMPREHENSIVE
MH102A MECHANICAL DUCTWORK PLAN - SECOND FLOOR - AREA A
MH102B MECHANICAL ROOF PLAN - AREA B
MP101A MECHANICAL PIPING PLAN - FIRST FLOOR - AREA A
MP101B MECHANICAL PIPING PLAN - FIRST FLOOR - AREA B
MP102A MECHANICAL PIPING PLAN - SECOND FLOOR - AREA A
M-301 MECHANICAL SECTIONS
M-302 MECHANICAL SECTIONS
M-401 ENLARGED PLAN - MECH ROOM 106
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-503 MECHANICAL DETAILS
M-601 MECHANICAL SCHEDULES
M-602 MECHANICAL SCHEDULES
M-701 TEMPERATURE CONTROLS NOTES & LEGENDS
M-702 HVAC TEMPERATURE CONTROLS
M-703 HVAC TEMPERATURE CONTROLS
M-704 HVAC TEMPERATURE CONTROLS
ELECTRICAL
E-001 LEGEND AND GENERAL NOTES
ES101 ELECTRICAL SITE POWER PLAN
EG101A GROUNDING PLAN - FIRST FLOOR - AREA A
EG101B GROUNDING PLAN - FIRST FLOOR - AREA B
EG102A GROUNDING PLAN - SECOND FLOOR - AREA A
EG103 LIGHTNING PROTECTION PLAN - ROOF
EG601 GROUNDING RISER DIAGRAM
EL101A LIGHTING PLAN - FIRST FLOOR - AREA A
EL101B LIGHTING PLAN - FIRST FLOOR - AREA B
EL102A LIGHTING PLAN - SECOND FLOOR - AREA A
EL501 LIGHTING PLATES
EL502 LIGHTING PLATES
EL701 LIGHTING FIXTURE SCHEDULE
EP101A POWER PLAN - FIRST FLOOR - AREA A
EP101B POWER PLAN - FIRST FLOOR - AREA B
EP102A POWER PLAN - SECOND FLOOR - AREA A
EP103 POWER PLAN - ROOF
EP401 ENLARGED PLANS
EP601 SINGLE LINE DIAGRAM
E-501 DETAILS
E-502 DETAILS
E-503 DETAILS
E-504 DETAILS
E-505 DETAILS
E-701 PANEL SCHEDULES
E-702 PANEL SCHEDULES
E-703 PANEL SCHEDULES
E-704 PANEL SCHEDULES
E-705 PANEL SCHEDULES
E-706 PANEL SCHEDULES
TELECOMMUNICATIONS
T-001 TELECOMMUNICATIONS GENERAL NOTES, SYMBOLS & ABBREVIATIONS
T-100 TELECOMMUNICATIONS SITE PLAN
T-101A TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA A
T-101B TELECOMMUNICATIONS FIRST FLOOR PLAN - AREA B
T-102A TELECOMMUNICATIONS SECOND FLOOR PLAN - AREA A
T-111A TELECOMMUNICATIONS FIRST FLOOR PATHWAYS - AREA A
T-111B TELECOMMUNICATIONS FIRST FLOOR PATHWAYS - AREA B
T-112A TELECOMMUNICATIONS SECOND FLOOR PATHWAYS - AREA A
T-401 TELECOMMUNICATIONS ENLARGED PLAN - COMM 102
T-402 TELECOMMUNICATIONS ENLARGED PLAN - COMM 202
T-403 TELECOMMUNICATIONS ENLARGED PLAN - COMM 236
T-501 TELECOMMUNICATIONS DETAILS
T-502 TELECOMMUNICATIONS DETAILS
T-503 TELECOMMUNICATIONS DETAILS
T-504 TELECOMMUNICATIONS CABINET ELEVATIONS ROOM 102
T-505 TELECOMMUNICATIONS CABINET ELEVATIONS ROOM 202
T-506 TELECOMMUNICATIONS CABINET ELEVATIONS ROOM 236
S
EA
L S
IG
N A
TU
R E
PLA
C
EH
O
LD
DRAWING ABBREVIATIONS
A ---------------------
AAP ALARM ANNUNCIATOR PANEL
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
ADJ ADJACENT, ADJUSTABLE
AESS ARCHITECTURAL EXPOSED
STRUCTURAL STEEL
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHR ANCHOR
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX. APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE, BOTTOM OF CURB
FACE FACE OF CURB
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BLW BELOW
BM BEAM
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BOTT. BOTTOM
BP BUILDING PAPER
BR BULLET-RESISTANT, BALLISTIC RATED
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY, COMBINATION AIR RELIEF VALVE
CB CATCH BASIN
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFH CUBIC FEET PER HOUR
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON, CURB INLET
CIP CAST-IN-PLACE
CJ CONTROL JOINT OR BRICK EXPN JOINT
CL CENTER LINE
CENTERLINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR, CLEAR
CLR. CLEAR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MOT MAINTENANCE OF TRAFFIC
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NAD NORTH AMERICAN DATUM
N.F. NEAR FACE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NGVD NATIONAL GEODETIC VERTICAL
DATUM
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OH OVERHEAD
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAF POWER ACTUATED FASTENER
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PC POINT OF CURVATURE
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCP PRECAST CONCRETE PANEL
PCT PERCENT
PEJ PREMOLDED EXPANSION JOINT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE, PLATE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
POT POINT OF TANGENT
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS PULL STATION
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED, POINT OF
TANGENCY
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PVC POINT OF VERTICAL CURVATURE,
POLYVINYL CHLORIDE
PVMT PAVEMENT
PVT POINT OF VERTICAL TANGENCY
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN,
REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REINF REINFORCEMENT
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RPZ REDUCED PRESSURE ZONE
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S --------------------
SAN SANITARY
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR / STORM DRAIN /
SOAP DISPENSER
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMHD SHELF, METAL, HEAVY DUTY
SMK SMOKE
SMLS SEAMLESS
SND SANITARY NAPKIN DISPOSER
SNT SEALANT
SNTD SANITARY NAPKIN AND TAMPON
DISPENSER
SOG SLAB ON GRADE
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SSD SUBSURFACE DRAIN
SST STAINLESS STEEL
ST STAIRS
STA. STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRL STRUCTURAL
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK / SWITCH
T --------------------
T TREAD
T&B TOP AND BOTTOM
T/S TUB/SHOWER
TC TERRA COTTA, TOP OF CURB
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
T.O. TOP OF
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB, TOP OF STEEL
T.O.W. TOP OF WALL
TRANS TRANSOM
TRTD TREATED
TSCD TOILET SEAT COVER DISPENSER
TSP TWISTED SHIELDED PAIR
TST TWISTED SHIELDED TRIPLE
T-STAT THERMOSTAT
TTD TOILET TISSUE DISPENSER
TU TERMINAL UNIT
TV TELEVISION, TELEVISION OUTLET
TVSS TRANSIENT VOLTAGE SURGE
SUPPRESSION
TYP TYPICAL
U --------------------
UC UNDERCUT
UFD UNDER FLOOR DUCT
UG UNDERGROUND
UH UNIT HEATER
UHF ULTRAHIGH FREQUENCY
UL UNDERWRITERS' LABORATORY
ULT ULTIMATE
UNIF UNIFORM
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
U.S. URINAL SCREEN
UTIL UTILITY
V --------------------
V SANITARY VENT
VA VOLT-AMPERE
VAC VACUUM, VOLTS AC
VAR VOLT-AMPERE REACTIVE
VAV VARIBLE AIR VOLUME
VB VAPOR BARRIER, VERTICAL BEND
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VD VOLUME DAMPER
VDC VOLTS DC
VDO VOICE/DATA OUTLET
VEL VELOCITY
VENT. VENTILATE
VERT VERTICAL
VEST. VESTIBULE
VFD VARIBLE FREQUENCY DRIVE
VHF VERY HIGH FREQUENCY
VIN VINYL COMPOSITION TILE
VLT VAULT
VM VOLTMETER
VOL VOLUME
VR VAPOR RETARDER
VS VERTICAL SLOT
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W --------------------
W WEST, WATT, WIDE, WIRE, WATER,
WATER MAIN OR SERVICE LINE
W/ WITH
W/O WITHOUT
WA WAINSCOT
WAS WASTE ACTIVATED SLUDGE
WB WET BULB, WIND BEAM
WC WATER CLOSET
WCO WALL CLEAN OUT
WD WOOD, WIDTH
WDO WINDOW
WFD WATER FLOW DETECTOR
WG WATER GAGE
WH WALL HYDRANT
WHA WATER HAMMER ARRESTER
WHS WELDED HEADED STUD
WI WROUGHT IRON
WL WIND LOAD, WATER LINE
WM WATER METER
WP WORKING POINT, WEATHERPROOF
WPF WATERPROOFING
WS WATER SURFACE, WATERSTOP
WST WASTE
WT WEIGHT
WTR WATER
WTS WELDED THREADED STUD
WWF WELDED WIRE FABRIC
WWR WELDED WIRE REINFORCEMENT
X --------------------
XARM CROSS ARM
XFMR TRANSFORMER
XFR TRANSFER
XMTR TRANSMITTER
Y --------------------
YD YARD
YHYD YARD HYDRANT
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONSTR. CONSTRUCTION BASELINE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM / CARD READER
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW / DOMESTIC COLD
WATER / CURTAIN WALL
CWB CAPILLARY WATER BARRIER
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DB DOORBELL
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DI DROP INLET, DUCTILE IRON
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DN DOWN
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
E.F. EACH FACE
EHD ELECTRIC HAND DRYER
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ELEV. ELEVATION
ENTR ENTRANCE
EP EDGE OF PAVEMENT
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQPT EQUIPMENT
EQUIP. EQUIPMENT
EO ELECTRICAL OUTLET
ES EACH SIDE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EX EXISTING
EXP EXPOSED
EXPN EXPANSION
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
F.F. FAR FACE
FFE FINISH FLOOR ELEVATION
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN. FINISH, FINISHED
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FROM / FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTC FIELD SOUND TRANSMISSION CLASS
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GEN GENERATOR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED, GROUND
FAULT CIRCUIT INTERRUPTOR
GFGI GOVERNMENT INSTALLED
FURNISHED INSTALLED BY
GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR GRADE
GR FL GROUND FLOOR
GUT GUTTER
GV GATE VALVE
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------
H-STAT HUMIDISTAT
HB HOSE BIBB, HORIZONTAL BEND
HD HIGH DENSITY
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HW DOMESTIC HOT WATER CIRCULATING
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
JT JOINT
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LLH LONG LEG HORIZ
LOC LOCATION / LOCAL OPERATING
CONSOLE
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL, PLUMBING
MF MILL FINISH
MFR MANUFACTURER
MG MIRROR GLASS
MH MOP HOLDER, MANHOLE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
CL
BL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
S
EA
L S
IG
N A
TU
R E
PLA
C
EH
O
LD
E R
G-003
A B
B R
E V
IA
T
IO
N
S
T M
C A
L L
IS
T E
R
T M
C A
L L
IS
T E
R
K G
U
IL
F O
Y L
FORT BRAGG
MILITARY RESERVATION
HOKE COUNTY
CUMBERLAND
COUNTY
CONNECTICUT AVENUE
M
AN
C H
ES
TE
R
RO
AD
RESERVATION ACCESS POINT
HOKE COUNTY
PROJECT SITE
CUMBERLAND COUNTY
FORT BRAGG
CONTRACTOR PARKING
PROJECT SITE
SEE G-005 FOR FORT BRAGG
CANTONMENT AND LAYMONT
RECYCLING LOCATION
MEMORYLANE
KIN
G
R O
AD
PLANK ROAD
RESERVATION ACCESS POINT
FROM ROUTE 2033
FROM ROUTE 1219
PLANK ROAD
PLANK ROAD PLA
NK R
OAD
SECURE ACCESS
CONTROL POINT
CHICKEN ROAD
MAC RIDGE ROAD
LONGSTREET ROAD
LAYM
O
N T R
O
AD
MANCHESTER ROAD
HIGHW
AY 24
MANCHESTER
ROAD
CONTRACTOR
HAUL ROUTE
US Army Corps of Engineers ®
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
SHEET OF
R
EA
D Y
TO
A
D
VE
R
TI
SE
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
AE
C
O M
S
ER
VI
C
ES
, I
N C
S . J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
, V A
M
. J O
N
ES
W
2-
PM
-D
/1
5/
-FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E:
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
AN
N
EX
B U
IL
D
IN
G
PN
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
NO R T H C A R O L I NA
B R I A N D O U G L A S F I S H E R
E N G I N E E R
P R O F E S S I O N A L
SEAL
046338
W
8-
XX
-X
C -X
XX
X
FORT BRAGG
30195
40401
301401
N
N.T.S.
VICINITY MAP
NORTH
CONTRACTOR PARKING
CONTRACTOR PARKING WILL BE LIMITED TO THE PROJECT SITE, AND
ASSIGNED STORAGE AREA AS DETERMINED BY THE CONTRACTING
OFFICER. ONLY PROPERLY IDENTIFIED COMPANY OWNED VEHICLES
WILL BE PERMITTED BEYOND THE SECURE ACCESS CONTROL POINT.
ALL PERSONAL AND PRIVATELY OWNED VEHICLES MUST PARK IN THE
DESIGNATED AREA LOCATED AT THE INTERSECTION OF MANCHESTER
ROAD AND CONNECTICUT ROAD. AT THE END OF THE CONSTRUCTION, THE
PARKING AREA FOR PRIVATELY OWNED VEHICLES MUST BE RESTORED TO
ORIGINAL CONDITION.
M . G
AR
LA
N D
A.
F
R
EE
LA
N
D
B.
F
IS
H
ER
H
AU
L
R O
U
TE
S
AN
D V
IC
IN
IT
Y
M
AP
G-004
DARLINGTON
S. CAROLINA
N. CAROLINA
WHITEVILLE
WILMINGTON
LUMBERTON
ELIZABETHTOWN
WALLACE
CLINTON
FAYETTEVILLE
ROCKINGHAM
LAURINBURG
BISCOE
ASHEBORO
SANFORD
RALEIGH
SMITHFIELD
WILSON
GOLDSBORO
MT. OLIVE
DUNN
ROAD CLOSED WITH
GATES OR BARRIERS
MAJOR ROADS
STREETS
RAILROADS
INSTALLATION BOUNDARIES
INTERSTATE ROUTE
U. S. ROUTE
STATE ROUTE
LAKES
ACCESS CONTROL POINT
LEGEND:
SIMMONS AIRFIELD
MAIN ENTRANCE
DEFENSE REUTILIZATION MARKETING
OFFICE (DRMO) BLDG. NO. J-1334
ACP#7 ACP#8A
ACP#13
ACP#9
ACP#3
ACP#1
ACCESS CONTROL POINT (ACP) #8
AND TRUCK INSPECTION PLAZA
ACP#12 AND SAT /SUN /HOLIDAYS 0900-1700
SOLDIER SUPPORT CENTER,
BUILDING 4-2843,
VEHICLE REGISTRATION
RECYCLING AREA
BUTNER RD
LONGSTREET RD
GRUBER RD
ALL AM
ER
IC
AN
FR
EEW
AYYADKIN RD
GRUBER RD
LONGSTREET RD
HONEYCUTT RD
HONEYCUTT RD
BR
AG
G
BLVD
BR
AG
G
BLVD
BR
AG
G
BLVD
GRUBER RD
M
URCHSON RD
RANDOLPH ST
KN
O
X ST
KNOX ST
R
EILLY ST
REILLY ST
R
EILLY ST
LAM
O
N T R
D
CHICKEN ROAD
CHICKEN ROAD
PLANK ROAD
MILITARY RESERVATION BOUNDARY
MILITARY RESERVATION BOUNDARY
MILITARY RESERVATION BOUNDARY
MILITARY RESERVATION BOUNDARY
M
IL
IT
AR
Y R
ES
ER
VA
TI
O N
M c R
ID
G
E R O
AD
NORMANDY DR
ARDENNES RD
SPO
O
N
ER
ST
OLD FORT BRAGG BOUNDARY
N
EW
F O
R T
BR
AG
G B
O U
N D
AR
Y
NORTHERN TRAINING AREA
AND THE OVERHILLS AREA.
AR
M
ISTEAD
ACP#10
ACP#11
ZABITO
SKIY R
O
AD
BASTOGNE DRIVE
ACP#2A
WOODRUFF ST
US ARMY CORPS OF ENGINEERS (USACE)
FORT BRAGG BARRACKS OFFICE
RANGE
DEMOLITION LANDFILL
CLOSED
LAMONT BORROW
PIT CLOSED
US ARMY CORPS OF ENGINEERS (USACE)
FORT BRAGG AREA OFFICE (BRA)
BLDG NO. 3-1933 BUTNER RD
MCKELLERS RD.
C O
O
LY
CONCH RD
DIRECTORATE OF PUBLIC WORKS
BUILDING NO. 3-1631
MCKELLERS RD.
LAM
O
N T R
D
ALL AMERICAN FREEWAY
FORT BRAGG CANTONMENT
SCALE 1" = 3000'
LAMONT RD SOLID
WASTER AND RECYCLING
LANDFILL FACILITY
JAC
KSO
N
USACE SOCOM RESIDENT OFFICE
BLDG. NO. 2-2414 WOODRUFF ST.
FT. BRAGG, NC 28310 (910)-432-8121
PLAN NORTH
WOMACK ARMY
MEDICAL CENTER
ACP#4
M
ILITAR
Y R
ESER
VATIO
N
BO
U
N D
AR
Y
BOUNDARY
MANCHESTER RD.
POPE ARMY AIRFIELD
MANCHESTER
RD.
NEW DAWN DR
AF
R
IC
AN
L
IO
N W
AY
TO
R
A
BO
R A
BL
VD
D ST
EAGLE TALON DR
SPARTAN WAY
AIR DEFENSE LOOP
TORA BORA BLVD
MOUNTAIN
VIPER DR
YORKTOWN VIC
TOR R
D.
RE
IL
LY
S
T
CA
NO
PY
L
N
AR
M
ISTEAD
HAUL ROAD (RECYCLING,
COMMERCIAL VEHICLE ACCESS)
POST ACCESS CONTROL POINT (ACP) PLAN & SECURITY NOTES
FORT BRAGG WILL BE USING THE AUTOMATED INSTALLATION ENTRY SYSTEM (AIE). THE PROCESS OF ACCESSING THE BASE IS
EXPLAINED IN SPECIFICATIONS SECTION 01 14 00, PARAGRAPH 1.4., PASSES.
INFO AND HOURS FOR ACP'S CAN BE FOUND AT WWW.BRAGG.ARMY.MIL/DIRECTORATES/DES/PAGES/DEFAULT.ASPX.
ALL VEHICLES ARE SUBJECT TO SEARCH, REGARDLESS OF MEANS OF ENTRY;AUTOMATED INSTALLATION ENTRY, TEMPORARY PASS, OR NEITHER. ALL CONTRACTOR'S COMMERCIAL OR PRIVATELY OWNED VEHICLES REQUIRE REGISTRATION.
ALL COMMERCIAL VEHICLES MUST ACCESS THE TRUCK PLAZA ON KNOX STREET. THE INSTALLATIONS DEFINITION FOR A
COMMERCIAL VEHICLE IS:
ANY VEHICLE AS LARGE AS OR LARGER THAN AN ENCLOSED 15-PASSENGER VAN (NOT USED FOR PASSENGER TRANSPORTATION) OR ANY COMPANY VEHICLE PULLING AN ENCLOSED TRAILER OF ANY SIZE, AND ALL CIVILIAN FUEL TRUCKS.
THIS INCLUDES U-HAUL TRUCKS, UPS/FEDEX DELIVERY VEHICLES, ETC. THE ONLY EXCEPTION TO THIS DEFINITION APPLIES TO ACTIVE DUTY MILITARY CAC CARD HOLDERS ONLY IF THE VEHICLE CAN SAFELY NEGOTIATE THE LANE AT FPCON NORMAL OR A.
IT IS A CRIME UNDER 18 USC 795 TO PHOTOGRAPH DEFENSE INSTALLATIONS WITHOUT FIRST OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY INSTALLATION. IT IS ALSO A CRIME UNDER 18 USC 797 TO REPRODUCE, PUBLISH, SELL OR GIVE AWAY ANY PHOTOGRAPH, PICTURE OR GRAPHIC REPRESENTATION OF A DEFENSE INSTALLATION WITHOUT FIRST
OBTAINING THE PERMISSION OF THE COMMANDING OFFICER OF THE MILITARY INSTALLATION.
FORT BRAGG IS DESIGNATED AS A RESTRICTED AREA. RESTRICTED AREA POSTING RESTRICTS PERSONS GAINING ACCESS TO MILITARY INSTALLATIONS FROM CONDUCTING IMAGERY SURVEILLANCE, PHOTOGRAPHY AND VIDEO RECORDING WITHOUT THE
INSTALLATION COMMANDERS CONSENT.
THE INTRODUCTION OF WEAPONS, AMMUNITION, EXPLOSIVES OR OTHER PROHIBITED ITEMS AND PHOTOGRAPHY ON FORT
BRAGG IS PROHIBITED WITHOUT SPECIFIC AUTHORIZATION FROM THE COMMANDER.
30195
301401
ASHEBORO
BISCOE
MT. OLIVE
SANFORD
N. CAROLINA
S. CAROLINA
FORT BRAGG
N
FAYETTEVILLE
RALEIGH
SMITHFIELD
LUMBERTON
DARLINGTON
LAURINBURG
ROCKINGHAM
WHITEVILLE
WILMINGTON
ELIZABETHTOWN
WALLACE
CLINTON
GOLDSBORO
WILSON
DUNN
VICINITY MAP
NOT TO SCALE
PROJECT LOCATION MAP
NOT TO SCALE
GENERAL NOTES:
1. THE FORT BRAGG LAMONT CONSTRUCTION AND DEMOLITION (C&D) LANDFILL IS CLOSED AND WILL NOT BE ACCEPTING ANY
C&D WASTE AND ASBESTOS WASTE.
2. THE MUNICIPAL SOLID WASTE (MSW) TRANSFER STATION AT THE LAMONT LANDFILL FACILITY IS CLOSED AND WILL NOT
EXCEPT MSW AT THE FACILITY.
3. ALL CONTRACTORS SHALL USE A STATE CERTIFIED C&D LANDFILL OR SUB TITLE “D”LANDFILL OFF FORT BRAGG FOR THE
DISPOSAL OF C&D WASTE, ASBESTOS WASTE AND MSW.
4. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN DATA OF ALL WASTE DISPOSED (C&D, ASBESTOS, AND MSW) AND ALL MATERIALS RECYCLED OFF FORT BRAGG. SEE SPECIFICATIONS FOR FORMS AND REPORTING REQUIREMENTS.
5. THE LAMONT LANDFILL FACILITY RECYCLING AREA WILL ACCEPT RECYCLABLES ITEMS.
CONCRETE, BRICK AND BLOCK
- SHALL BE TESTED AND FREE OF ASBESTOS AND LEAD BASED PAINT TO BE RECYCLED
- SHALL BE NO LARGER THAN 2’ BY 2’ PIECES OR EQUIVALENT
- SHALL BE MINIMAL AMOUNT OF DIRT IN LOAD
- SHALL HAVE NO REBAR PROTRUDING OUT OF THE CONCRETE
TREES, LIMBS AND STUMPS
- SHALL BE CUT TO 6 FEET OR LESS IN LENGTH
- IF THE TREE HAS A LARGE DIAMETER (EXAMPLE 3 FT. DIA.) IT SHALL BE CUT TO LENGTHS OF 3 FEET OR LESS
- SHALL BE MINIMAL AMOUNT OF DIRT IN LOAD OR IN STUMP ROOTS
- WILL EXCEPT GROUND WOOD CHIPS
- NO TRASH IN LOAD
PALLETS
- SERVICEABLE AND NON-SERVICEABLE PALLETS
SCRAP STEEL
- NO ITEMS REQUIRING DEMILITARIZED ACCEPTED
- NO ITEMS WITH LIQUIDS IN THEM
SCRAP ALUMINUM
- NO ITEMS REQUIRING DEMILITARIZED ACCEPTED
- NO ITEMS WITH LIQUIDS IN THEM
CARDBOARD TO BE RECYCLED
- A 40 YARD DUMPSTER IS AVAILABLE FOR CARDBOARD
- ALSO CARDBOARD CAN BE TAKEN TO THE FORT BRAGG RECYCLING CENTER AT BLDG 3-1240, BUTNER AND REILLY ROAD
- SHALL BE CLEAN OF TRASH, PLASTICS, STYROFOAM, WOOD, METAL, ETC.
6. CONTACT YOUR GOVERNMENT REPRESENTATIVE OR THE SOLID WASTE/RECYCLING PROGRAM AT 977-2502, 396-3372 OR
432-6412 FOR ADDITIONAL GUIDANCE.
7. STATE LAW AND FORT BRAGG REGULATIONS REQUIRES COVERING OF LOADS OF WASTE OR RECYCLABLES TO PREVENT
LITTER.
8. ALL WASTE OR RECYCLABLE MATERIAL LOADS ARE SUBJECT TO BE INSPECTED OF THEIR CONTENTS WHILE BEING PRESENT
ON FORT BRAGG.
9. ALL RECYCLABLE MATERIALS GENERATED FROM A CONSTRUCTION OR DEMOLITION JOB IS PROPERTY OF THE GOVERNMENT UNLESS THE CONTRACT SPECIFIES THAT THE CONTRACT CAN OBTAIN THE MATERIALS. ITEMS SUCH AS HVAC UNITS (FREON REMOVED), AIR HANDLERS, PIPING, METALS BEAMS, MOTORS, VALVES, COPPER WIRE, ETC. THESE TYPES OF ITEMS SHALL BE TRANSPORTED TO THE DPW RECYCLING CENTER (BUTNER AND REILLY ROAD) OR THE RECYCLING AREA AT THE LAMONT
LANDFILL FACILITY.
10. ALL ASPHALT PAVEMENT (INCLUDING MILLED) SHALL BE DISPOSED OF OFF INSTALLATION AT CONTRACTOR'S EXPENSE.
11. ALL SUITABLE AND NONSUITABLE MATERIALS SHALL BE DISPOSED OF OFF INSTALLATION AT CONTRACTOR'S EXPENSE.
12. REFERENCE HTTPS://HOME.ARMY.MIL/BRAGG/INDEX.PHP/MY-FORT-BRAGG/ALL-SERVICES/GATE-INFORMATION FOR
UP-TO-DATE GATE ACCESS INFORMATION.
US Army Corps of Engineers ®
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
SHEET OF
R
EA
D Y
TO
A
D
VE
R
TI
SE
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
AE
C
O M
S
ER
VI
C
ES
, I
N C
S . J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
, V A
M
. J O
N
ES
W
2-
PM
-D
/1
5/
-FI
LE
N
AM
E:
C
AT
EG
O
R Y
C O
D E:
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
SO
F
O
PE
R
AT
IO
N
S
AN
N
EX
B U
IL
D
IN
G
PN
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
W
IL
M
IN
G
TO
N , N
O R
TH
C
AR
O
LI
N
A
NOR T H C A R OL I NA
B R I A N D O U G L A S F I S H E R
E N G I N E E R
P R O F E S S I O N A L
SEAL
046338
W
8-
XX
-X
C -X
XX
X
SEE SHEET G-004
FOR PROJECT LOCATION
GRAPHIC SCALES
1"=3000'
6000'3000'01500'3000'
M . G
AR
LA
N D
A.
F
R
EE
LA
N
D
B.
F
IS
H
ER
FO
R T
BR
AG
G C
AN
TO
N M
EN
T
G-005
1. PRIMARY APPLICABLE CRITERIA
• INTERNATIONAL BUILDING CODE (IBC), 2018
• NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1, FIRE CODE, 2018
• NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2018
• NFPA 13, STANDARD FOR THE INSTALLATION OF AUTOMATIC SPRINKLER SYSTEMS,
• NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE SERVICE MAINS AND THEIR
APPURTENANCES, 2019
• NFPA 70, NATIONAL ELECTRICAL CODE, 2020
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2019
• NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2019
• NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND
VENTILATING SYSTEMS, 2018
• NFPA 101, LIFE SAFETY CODE, 2018
• SAVANNAH DISTRICT DESIGN MANUAL FOR MILITARY CONSTRUCTION, OCTOBER
• UFC 1-200-01, DOD BUILDING CODE, 8 OCTOBER 2019
• UFC 1-200-02, DESIGN: HIGH PERFORMANCE AND SUSTAINABLE BUILDING
REQUIREMENTS, 1 DECEMBER 2016 WITH CHANGE 4, 1 OCTOBER 2019
• UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, 8 AUGUST 2016 WITH
CHANGE 4, 7 FEBRUARY 2020
• UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, 12
DECEMBER 2018
• UFC 4-010-05, SENSITIVE COMPARTMENTED INFORMATION FACILITIES PLANNING,
DESIGN AND CONSTRUCTION, 1 FEBRUARY 2013, WITH CHANGE 1, 1 OCTOBER
• UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION, 9 APRIL 2008, WITH CHANGE 1,
1 JANUARY 2010
2. OCCUPANCY CLASSIFICATION (IBC §303.4, §304.1; NFPA 101 §6.1.2, §6.1.11)
THE SOF OPERATIONS FACILITY IS CLASSIFIED AS A NON-SEPARATED MIXED USE
OCCUPANCY. THERE ARE GROUP B (BUSINESS), GROUP S-1 (CAGED STORAGE), AND GROUP
A-3 (ASSEMBLY) OCCUPANCIES (IBC) AND NEW BUSINESS, STORAGE AND ASSEMBLY (NFPA
101) OCCUPANCIES.
3. CONSTRUCTION TYPE (IBC §601)
CONSTRUCTION IS TYPE IIB (IBC) AND WILL BE OF AN UNPROTECTED, NONCOMBUSTIBLE
NATURE.
4. ALLOWABLE FLOOR AREAS (IBC TABLE 506.2)
ALLOWABLE AREA FOR A TWO STORY SPRINKLERED TYPE IIB CONSTRUCTION BUILDING:
GROUP B: 69,000 SF
GROUP S-1: 52,500 SF
GROUP A-3: 28,500 SF
ACTUAL AREA IS APPROXIMATELY 15,000 SF FOR THE FIRST FLOOR AND 9,000 SF FOR THE
SECOND FLOOR. FRONTAGE INCREASES IN ACCORDANCE WITH IBC §506.3 WERE NOT
CALCULATED SINCE THE LOWEST ALLOWABLE AREA PER STORY (28,500 SF) IS ALREADY
GREATER THAN THE ACTUAL AREA PER STORY (15,000 SF).
5. MAXIMUM HEIGHT AND NUMBER OF STORIES OF BUILDING (IBC TABLE 504.3, TABLE 504.4)
ALLOWABLE HEIGHT AND NUMBER OF STORIES FOR A SPRINKLERED TYPE IIB
CONSTRUCTION BUILDING:
GROUP B, S-1 & A-3: 75 FT.
GROUP B: 4 STORIES
GROUP A-3 & S-1: 3 STORIES
ACTUAL HEIGHT IS 2 STORIES AND APPROXIMATELY 52 FEET.
6. FIRE-RESISTIVE SUBSTITUTION (IBC TABLE 601)
FOR TYPE IIB CONSTRUCTION:
7. FIRE RESISTIVE/STRUCTURAL FIRE PROTECTION REQUIREMENTS
7.1. SEISMIC PROTECTION (IBC §1613)
THE SEISMIC DESIGN CATEGORY C REQUIRES SEISMIC PROTECTION FOR FIRE PROTECTION
SYSTEMS IN ACCORDANCE WITH NFPA 13.
7.2. EXTERIOR WALLS (IBC TABLE 602)
FOR TYPE IIB CONSTRUCTION, THE EXTERIOR WALLS ARE PERMITTED TO REMAIN UNRATED
IF THERE IS ADEQUATE FIRE SEPARATION DISTANCE PROVIDED FROM ADJACENT BUILDINGS
(WHICH ARE ALSO TYPE IIB CONSTRUCTION). A MINIMUM OF 20 FT SEPARATION IS NEEDED
FROM ADJACENT PHASE 3 BUILDINGS IN ORDER TO REMAIN UNRATED IN ACCORDANCE
WITH IBC TABLE 602.
LIFE SAFETY CODE ANALYSIS: SOF OPERATIONS ANNEX
7.3. SHAFT ENCLOSURES (IBC §707.3.1; NFPA 101 §8.6.5; NFPA 90A §5.3.4.3.1)
SHAFT ENCLOSURES SHALL HAVE A 1-HOUR FIRE RESISTANCE OR NOT LESS
THAN THE FLOOR ASSEMBLY PENETRATED, WHICHEVER IS GREATER. IN THE
CASE OF TYPE IIB CONSTRUCTION, THE FLOOR ASSEMBLY HAS NO FIRE
RESISTANCE RATING. THEREFORE, ALL SHAFT ENCLOSURES (INCLUDING STAIRS)
SHALL HAVE A 1-HOUR FIRE RESISTANCE RATING.
A FIRE RATING FOR THE MAIN MECHANICAL SHAFT IS NOT REQUIRED PER NFPA
90 §5.3.4.3.1 SINCE THE DUCTS PENETRATE ONLY ONE FLOOR AND AN AIR-
HANDLING EQUIPMENT PENTHOUSE FLOOR (ROOF). A FIRE DAMPER IS REQUIRED
AT THE FLOOR PENETRATION.
7.4. CORRIDORS (NFPA 101 §12.3.6)
CORRIDORS ARE NOT REQUIRED TO BE RATED AS THE BUILDING IS FULLY
SPRINKLERED.
7.5. STRUCTURAL FRAME FIRE RESISTANCE RATINGS (IBC TABLE 601)
NONE REQUIRED FOR TYPE IIB CONSTRUCTION.
7.6. FIREWALLS (IBC §706; NFPA 101 §8.2.2.4)
NOT APPLICABLE FOR SINGLE BUILDING.
8. FIRE SUPPRESSION SYSTEMS (UFC 3-600-01 §9-7)
AN AUTOMATIC WET-PIPE SPRINKLER SYSTEM WILL BE DESIGNED AND
INSTALLED IN ACCORDANCE WITH NFPA 13 AND UFC 3-600-01. THE SYSTEM RISER
SHALL BE LOCATED IN THE FIRST FLOOR MECHANICAL ROOM. THE SYSTEM
RISER SHALL BE PROVIDED WITH AN INDICATING CONTROL VALVE, CHECK
VALVE, AND A FLOW SWITCH. ALL SYSTEM CONTROL VALVES WILL BE
SUPERVISED BY THE FIRE ALARM SYSTEM.
9. PORTABLE FIRE EXTINGUISHERS (UFC 3-600-01 §9-17)
PORTABLE FIRE EXTINGUISHERS ARE REQUIRED AND WILL BE PROVIDED IN
ACCORDANCE WITH NFPA 10.
10. ENCLOSURE PROTECTION (HAZARDOUS AREAS) (NFPA 101 §8.7, §38.3.2)
THE MECHANICAL ROOM SHALL BE ENCLOSED BY SMOKE PARTITIONS IN
ACCORDANCE WITH THE SPECIAL HAZARD PROTECTION CRITERIA OF NFPA 101.
TELECOMMUNICATION ROOMS SHALL BE ENCLOSED BY 2-HOUR FIRE RATED
CONSTRUCTION.
11. OPENING PROTECTIVES (NFPA 101 §8.3.3)
OPENINGS IN FIRE RESISTANCE-RATED ASSEMBLIES WILL BE IN ACCORDANCE
WITH NFPA 101 TABLE 8.3.3.2.2.
DOORS IN SMOKE PARTITIONS SHALL NOT INCLUDE LOUVERS AND SHALL BE
SELF-CLOSING. DOOR CLEARANCES SHALL BE IN ACCORDANCE WITH NFPA 80.
12. THROUGH PENETRATIONS & JOINT SYSTEMS (IBC §714, §715)
PENETRATIONS THROUGH FIRE BARRIERS, PARTITIONS, AND HORIZONTAL
ASSEMBLIES WILL BE PROVIDED WITH APPROPRIATE LISTED SYSTEM
ASSEMBLIES. JOINT SYSTEMS WILL BE PROVIDED TO PROTECT JOINTS WHERE
FIRE RESISTANCE RATED CONSTRUCTION ASSEMBLIES CONVERGE.
13. FIRE DAMPERS (UFC 3-600-01 §28-1, NFPA 90A §5.3)
FIRE DAMPERS AND SMOKE DAMPERS WILL BE PROVIDED IN ACCORDANCE WITH
REQUIREMENTS OF NFPA 90A. FIRE DAMPERS WILL NOT BE REQUIRED FOR
DUCTED PENETRATIONS OF 1 HOUR BARRIERS AND PARTITIONS. UN-DUCTED AIR
TRANSFER OPENINGS IN SMOKE PARTITIONS WILL BE PROVIDED WITH SMOKE
DAMPERS.
14. DETECTION, ALARM, AND COMMUNICATION. (UFC 3-600-01 §9-18)
A NEW ADDRESSABLE FIRE ALARM SYSTEM DESIGNED AND INSTALLED IN
ACCORDANCE WITH NFPA 72 IS REQUIRED TO SUPERVISE THE AUTOMATIC
SPRINKLER SYSTEM AND TO PROVIDE FOR OCCUPANT AND FIRE DEPARTMENT
NOTIFICATION OF A FIRE ALARM CONDITION.
THE FIRE ALARM SYSTEM WILL INCLUDE A NEW FIRE ALARM CONTROL PANEL, IP-
COMPATIBLE DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT),
SUPERVISION OF SPRINKLER SYSTEM ALARM AND SUPERVISORY DEVICES, DUCT
SMOKE DETECTORS, MANUAL FIRE ALARM PULL STATIONS, AUDIBLE
NOTIFICATION APPLIANCES (SPEAKERS), AND VISUAL NOTIFICATION APPLIANCES
(STROBES). FIRE ALARM PULL STATIONS WILL BE LOCATED WITHIN FIVE FEET OF
EVERY EXIT FROM THE BUILDING.
NOTIFICATION WILL INCLUDE AUDIBLE APPLIANCES AND WILL BE PROVIDED WITH
SPEAKERS THROUGHOUT, AND WILL BE INTELLIGIBLE WITH A CIS SCORE OF 0.8
IN ACCORDANCE WITH NFPA 72 AND UFC 4-021-01. VISUAL NOTIFICATION
APPLIANCES ARE TO BE LOCATED THROUGHOUT THE BUILDING AND WILL BE
ACCOMPLISHED THROUGH THE USE OF STROBES IN ACCORDANCE WITH UFC
3-600-01, UFC 4-021-01, AND NFPA 72.
17.4. DEAD END LIMITS AND COMMON PATH OF TRAVEL (NFPA 101
§7.5.1.6, §12.2.5, §38.2.5, TABLE 42.2.5)
DEAD END CORRIDORS (DEC) AND COMMON PATHS OF TRAVEL
(CPT) ARE LIMITED AS FOLLOWS:
20 FT. DEC
75 FT. CPT (WHEN SERVING LESS THAN 50 PEOPLE,
OTHERWISE 20 FT CPT)
SINCE THE BUILDING IS NON-SEPARATED, THE ENTIRE BUILDING
MUST COMPLY WITH THE MOST RESTRICTIVE TRAVEL DISTANCE
REQUIREMENTS FOR ALL OCCUPANCIES. HOWEVER, NFPA 101
ALLOWS FOR A COMMON PATH OF TRAVEL THAT OCCURS WHOLLY
IN A BUSINESS TENANT SPACE, IN A MULTIPLE OCCUPANCY
BUILDING CONTAINING ASSEMBLY AND BUSINESS OCCUPANCIES,
TO NOT HAVE TO MEET THE ASSEMBLY OCCUPANCY COMMON
PATH OF TRAVEL LIMITATION. THEREFORE, IN AREAS THAT ARE
STRICTLY BUSINESS AND DO NOT INVOLVE ASSEMBLY AREAS, THE
COMMON PATH OF TRAVEL MUST MEET THE BUSINESS OCCUPANCY
LIMITATION (100 FEET). THIS APPLIES TO THE SECOND FLOOR.
17.5. MEASUREMENT OF TRAVEL DISTANCE TO EXITS (NFPA 101
§7.6, §12.2.6, §38.2.6, TABLE 42.2.6)
TRAVEL DISTANCES TO EXITS (TDE) ARE LIMITED AS FOLLOWS:
250 FT. TDE
17.6. ILLUMINATION OF MEANS OF EGRESS (NFPA 101 §7.8, §12.2.8,
§38.2.8)
ILLUMINATION OF MEANS OF EGRESS IS REQUIRED FOR
DESIGNATED STAIRS, AISLES, CORRIDORS, RAMPS, AND
PASSAGEWAYS AND WILL BE PROVIDED.
17.7. EMERGENCY LIGHTING (NFPA 101 §7.9, §12.2.9, §38.2.9)
EMERGENCY LIGHTING IS REQUIRED FOR DESIGNATED STAIRS,
AISLES, CORRIDORS, RAMPS, AND PASSAGEWAYS AND WILL BE
PROVIDED.
17.8. MARKING OF MEANS OF EGRESS (NFPA 101 §7.10, §12.2.10,
§38.2.10)
MARKING OF ALL MEANS OF EGRESS IS REQUIRED AND WILL BE
PROVIDED.
17.9. ROOF ACCESS (UFC 3-600-01 §10-4, IBC §1011.12)
ACCESS TO THE ROOF VIA AN INTERIOR STAIRWAY IS NOT
REQUIRED WHEN BUILDING IS LESS THAN 4 STORIES IN HEIGHT.
18. FIRE DEPARTMENT ACCESS (UFC 3-600-01 §9-1, NFPA 1)
18.1. FIRE APPARATUS ACCESS (UFC 3-600-01 §9-1, NFPA 1 §18.2.3, §
18.2.3.2.2.1)
ALL-WEATHER GROUND ACCESS IS REQUIRED WITHIN 33 FEET OF
AT LEAST ONE EXTERIOR DOOR THAT CAN BE OPENED FROM THE
OUTSIDE AND THAT PROVIDES ACCESS TO THE INTERIOR OF THE
BUILDING. FIRE DEPARTMENT ACCESS ROADS WILL BE PROVIDED
SUCH THAT ANY PORTION OF AN EXTERIOR WALL IS LOCATED NOT
MORE THAN 450 FEET FROM THE FIRE DEPARTMENT ACCESS
ROADS AS MEASURED BY AN APPROVED ROUTE AROUND THE
EXTERIOR OF THE BUILDING. THE SPRINKLER SYSTEM FIRE
DEPARTMENT CONNECTION (FDC) MUST BE WITHIN 150 FEET OF A
FIRE DEPARTMENT ACCESS ROAD. THE DIMENSIONS OF FIRE
LANES AND TURNAROUNDS AND THE MARKING OF SUCH
PROVISIONS WILL COMPLY WITH NFPA 1 AND ANY REQUIREMENTS
OF THE LOCAL FIRE DEPARTMENT.
18.2. FIRE HYDRANTS (NFPA 1 §18.3; UFC 3-600-01 §9-3.5)
FIRE HYDRANTS WILL BE LOCATED SUCH THAT EVERY PORTION OF
THE BUILDING EXTERIOR IS WITHIN 350 FT. OF A HYDRANT WITH
CONSIDERATION GIVEN TO ACCESSIBILITY AND OBSTRUCTIONS. A
FIRE HYDRANT WILL BE LOCATED WITHIN 150 FT. OF THE FIRE
DEPARTMENT CONNECTION.
BUILDING ELEMENT FIRE RESISTANCE RATING
REQUIREMENT (HOURS)
STRUCTURAL FRAME
BEARING WALLS (EXTERIOR)
BEARING WALLS (INTERIOR)
INTERIOR NONBEARING WALLS & PARTITIONS
FLOOR CONSTRUCTION
ROOF CONSTRUCTION
14. DETECTION, ALARM, AND COMMUNICATION. (CONTINUED)
AREA SMOKE DETECTION WILL BE PROVIDED AT THE FIRE ALARM CONTROL
PANEL (FACP) AND NOTIFICATION APPLIANCE CIRCUIT (NAC) EXTENDER PANELS
IN ACCORDANCE WITH NFPA 72 §10.15. DUCT SMOKE DETECTORS WILL BE
PROVIDED IN ACCORDANCE WITH NFPA 90A.
THE FIRE ALARM SYSTEM WILL BE COMPATIBLE WITH THE EXISTING FT. BRAGG
BASE WIDE FIRE ALARM SYSTEM VIA AN IP COMPATIBLE DACT.
THE CONTRACTOR SHALL PROVIDE A RADIO TRANSMITTER FOR
COMMUNICATION WITH THE BASE WIDE FEDERAL SIGNAL MASS NOTIFICATION
SYSTEM.
15. MASS NOTIFICATION (UFC 4-010-01 §B-4.6, UFC 3-600-01 §9-18.11, UFC 4-021-01
§3-6.11)
A MASS NOTIFICATION SYSTEM (MNS) WILL BE PROVIDED THROUGHOUT THE
FACILITY AS REQUIRED BY UFC 4-010-01. IT WILL RECEIVE AND SEND SIGNALS
THROUGH THE EXISTING BASE WIDE FEDERAL SIGNAL MASS NOTIFICATION
SYSTEM.
15.1. AUTONOMOUS CONTROL UNIT (UFC 4-021-01 §4-3.2)
THE MASS NOTIFICATION AUTONOMOUS CONTROL UNIT WILL BE FULLY
INTEGRATED WITH THE FIRE ALARM SYSTEM TO PROVIDE A COMBINED SYSTEM,
AS INDICATED IN UFC 4-021-01 §4-3.2.2. NOTIFICATION APPLIANCES WILL BE
SHARED WITH FIRE ALARM SYSTEM, PER §4-3.4.2.
15.2. LOCAL OPERATING CONSOLE – LOC (UFC 4-021-01 §4-5.1)
AN LOC WILL BE PROVIDED AT EACH FACILITY ENTRANCE THAT WILL BE USED
DURING ELEVATED TERRORISM THREAT LEVELS, AND SO THAT OCCUPANTS DO
NOT NEED TO TRAVEL MORE THAN 200 FT. TO ACCESS AN LOC.
15.3. MESSAGING (UFC 4-021-01 §4-3.3)
THE CONTENTS OF EACH MESSAGE WILL COMPLY WITH THE PARAMETERS OF
UFC 4-021-01.
16. INTERIOR FINISHES (UFC 3-600-01 §8-1, NFPA 101 §10.2.8, 12.3.3, 38.3.3)
ALL AREAS (EXCEPT AS NOTED BELOW): CLASS A, CLASS B, OR CLASS C
INTERIOR FINISH MATERIALS ARE PERMITTED.
CORRIDORS AND EXIT ENCLOSURES: CLASS A OR CLASS B INTERIOR FINISH
MATERIALS ARE PERMITTED.
16.1. FLOOR FINISH (NFPA 101 §10.2.7, §38.3.3.3)
CARPET AND CARPET-LIKE INTERIOR FLOOR FINISHES WILL COMPLY WITH ASTM
D 2859, STANDARD TEST METHOD FOR IGNITION CHARACTERISTICS OF FINISHED
TEXTILE FLOOR COVERING MATERIALS. FLOOR COVERINGS, OTHER THAN
CARPET, WILL HAVE A CRITICAL RADIANT FLUX OF 0.1 W/CM2.
17. OCCUPANT LOAD (UFC 3-600-01 §10-3, NFPA 101 §7.3.1)
OCCUPANT LOAD FACTORS PER UFC 3-600-01 TABLE 10-1 AND NFPA 101 TABLE
7.3.1.2 ARE AS FOLLOWS:
ASSEMBLY, LESS-CONCENTRATED: 15 SF/PERSON NET
BUSINESS: 150 SF/PERSON GROSS
BUSINESS, CONCENTRATED: 50 SF/PERSON GROSS
EDUCATIONAL, CLASSROOMS: 20 SF/PERSON NET
MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES: 500
SF/PERSON GROSS
IT EQUIPMENT ROOMS: 300 SF/PERSON GROSS
STORAGE, IN OTHER THAN STORAGE AND MERCANTILE OCCUPANCIES: 500
SF/PERSON GROSS
17.1. TOTAL CALCULATED LOAD (UFC 3-600-01 TABLE 10-1 AND NFPA 101 TABLE
7.3.1.2)
REFER TO SHEET GI002 FOR OCCUPANT LOAD TOTALS PER FLOOR.
17.2. EGRESS CAPACITY (STAIRS, CORRIDORS, RAMPS AND DOORS) (NFPA 101 §
7.3.3, §12.2.3.6, §38.2.3)
CAPACITY FACTORS: MEANS OF EGRESS COMPONENTS WILL BE SIZED USING
CALCULATED OCCUPANT LOADS MULTIPLIED BY THE FOLLOWING CAPACITY
FACTORS: 0.3 IN. (STAIRWAYS ≤ 44”), AND 0.2 IN. (LEVEL COMPONENTS AND
RAMPS), BUT MUST BE A MINIMAL SIZE AS STATED BELOW.
AISLES, CORRIDORS, AND RAMPS: MIN. 36 IN. WHEN SERVING LESS THAN 50
PERSONS, OTHERWISE 44 IN.
DOORS: MINIMUM 32 IN. CLEAR WIDTH FOR DOORS. DOORS WILL SWING IN THE
DIRECTION OF EGRESS WHEN SERVING AN OCCUPANT LOAD OF 50 OR GREATER,
PER NFPA 101: 7.2.1.4.2. DOOR SWINGS WILL NOT ENCROACH INTO REQUIRED
EGRESS WIDTH GREATER THAN 1/2 DISTANCE; WHEN FULLY OPEN THEY WILL
ONLY ENCROACH A MAXIMUM OF 7 IN., PER NFPA 101: 7.2.1.4.3.1.
STAIRS: MINIMUM OF 44 IN. PER NFPA 101: TABLE 7.2.2.2.1.2(B)
THE MAIN ENTRANCE WILL BE SIZED TO ACCOMODATE ONE-HALF OF THE
AUDITORIUM OCCUPANT LOAD IN ACCORDANCE WITH NFPA 101.
17.3. REMOTENESS OF EXITS (NFPA 101 §7.5.1.3)
MINIMUM 1/3 OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING
OR AREA TO BE SERVED INCLUDING EXITS, EXIT ACCESS, AND EXIT DISCHARGE.
THE BUILDING DIAGONAL DIMENSION AND ADEQUATE EXIT SEPARATION
DIMENSION ARE SHOWN ON THE LIFE SAFETY FLOOR PLANS FOR BOTH FLOORS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
GI001
B U
IL
D
IN
G
L
IF
E
S A
F E
T Y
C O
D E
A N
A L Y
S
IS
S S
IE
G
F R
IE
D
T M
C A
L L
IS
T E
R
J B
R E
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
R E
A D
Y T
O A
D V
E R
T
IS
E
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
M J O
N E
S
W -P
M -D
/1
/2
-F
IL
E N
A M
E
C A
T E
G O
R Y
C O
D E
F O
R T
B R
A G
G N
O R
T H
C A
R O
L
IN
A
S O
F O
P E
R A
T
IO
N S
A N
N E
X B
U
IL
D
IN
G
P N
W
IL
M
IN
G T
O N
D
IS
T R
IC
T
W
IL
M
IN
G T
O N
N
O R
T H
C A
R O
L
IN
A
GI002
L
IF
E S
A F
E T
Y O
C C
U P
A N
T L
O A
D S
C H
E D
U L E
S
S S
IE
G
F R
IE
D
T M
C A
L L
IS
T E
R
J B
R E
E N
FIRST FLOOR OCCUPANT LOAD CALCULATION
NAME USE AREA SF / PERSON
GROSS /
NET
OCCUPANT
LOAD
MULTIPURPOSE ROOM A ASSEMBLY: LESS CONCENTRATED USE, WITHOUT FIXED SEATING 1441.8 SF 15.00 SF NET 96
MULTIPURPOSE ROOM B ASSEMBLY: LESS CONCENTRATED USE, WITHOUT FIXED SEATING 2158.3 SF 15.00 SF NET 143
MULTIPURPOSE ROOM C ASSEMBLY: LESS CONCENTRATED USE, WITHOUT FIXED SEATING 1807.7 SF 15.00 SF NET 120
BUSINESS BUSINESS 3335.2 SF 150.00 SF GROSS 22
TELECOM ROOM IT EQUIPMENT ROOMS & TELECOMMUNICATIONS ROOMS* 174.4 SF 300.00 SF GROSS 1
ELECTRICAL ROOM MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES 85.0 SF 500.00 SF GROSS 1
ELEVATOR / ELEV EQUIP MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES 179.8 SF 500.00 SF GROSS 1
MECHANICAL ROOM MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES 519.8 SF 500.00 SF GROSS 1
CAGED STORAGE STORAGE: IN STORAGE OCCUPANCIES 4490.4 SF 500.00 SF GROSS 9
TOTAL 14192.4 SF 394
SECOND FLOOR OCCUPANT LOAD CALCULATION
NAME USE AREA SF / PERSON
GROSS /
NET
OCCUPANT
LOAD
CONFERENCE ROOM ASSEMBLY: LESS CONCENTRATED USE, WITHOUT FIXED SEATING 393.8 SF 15.00 SF NET 26
BREAK ROOM ASSEMBLY: LESS CONCENTRATED USE, WITHOUT FIXED SEATING 139.7 SF 15.00 SF NET 9
BUSINESS AREAS BUSINESS 4996.8 SF 150.00 SF GROSS 33
OPEN OFFICE 222 BUSINESS: CONCENTRATED 1030.4 SF 50.00 SF GROSS 21
OPEN OFFICE 230 BUSINESS: CONCENTRATED 636.0 SF 50.00 SF GROSS 12
OPEN OFFICE 220 EDUCATIONAL: CLASSROOMS 812.4 SF 20.00 SF NET 40
TELECOM ROOM IT EQUIPMENT ROOMS & TELECOMMUNICATIONS ROOMS* 308.9 SF 300.00 SF GROSS 1
ELECTRICAL ROOM MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES 58.0 SF 500.00 SF GROSS 1
ELEVATOR MECHANICAL, ELECTRICAL, OTHER BUILDING EQUIPMENT SPACES 95.9 SF 500.00 SF GROSS 1
PRINT/COPY/STORAGE STORAGE: IN OTHER THAN STORAGE AND MERCANTILE OCCUPANCIES 119.1 SF 500.00 SF GROSS 1
8591.0 SF 145
S S
S
SS SSS
S S
S S
S S
S S
S S
S S
S
SS S
S S
S SS
S S
S S
S S
S S
SS S
S SS
B C D E
F G
A
MECHANICAL
ROOM
STORAGE
WOMEN
COMM
STAIR 2
SUPPORT STAFF
STAIR 1
LOBBY
MULTI-PURPOSE
ROOM B
CORR
100C
ELEC
ELEV EQUIP
MEN
JAN.
WOMEN
VESTIBULE
100A
CORR
100B
MULTI-PURPOSE
ROOM A
MULTI-PURPOSE
ROOM C
STORAGE
STORAGE
LAUNDRY
USE LEGEND - UFC 3-600-01:
ASSEMBLY: LESS CONCENTRATED USE,
WITHOUT FIXED SEATING
BUSINESS
IT EQUIPMENT ROOMS &
TELECOMMUNICATIONS ROOMS*
MECHANICAL, ELECTRICAL, OTHER BUILDING
EQUIPMENT SPACES
STORAGE: IN STORAGE OCCUPANCIES
E-1
E-2
E-3
E-4
E-5
E-6*
E-7
E-8
1. TDE(1)
1. CPT(1)
MEN
ELEV
E1
E-10*
BUILDING DIAGONAL = 197' - 10"
E X
IT
S
E P
A R
A T
IO
N
1. TDE(2)
0.01
MULTIPURPOSE ROOM A DIAGONAL = 72' - 8"
MULTIPURPOSE ROOM A EXIT SEPARATION = 62' - 9"
MULTIPURPOSE ROOM B DIAGONAL = 7
5' -
3"
MULTIPURPOSE ROOM B EXIT SEPARATION = 66' - 6"
MULTIPURPOSE ROOM C DIAGONAL = 7
4' - 1
MULTIPURPOSE ROOM C EXIT SEPARATION = 68' - 5"
OFFICE
110D
OFFICE
110C
OFFICE
110B
OFFICE
110A
E-9
0.02
1. DEC(1)
0.04
0.04
SMOKE PARTITION
1 HR FIRE BARRIER
LIFE SAFETY LEGEND
DESCRIPTION SYMBOL
FIRE EXTINGUISHER, DRY CHEMICAL (ABC…
This is the start of the file's text. The full file is on GovTribe.