Revised Plan Sheet A-001

View the file

Other files for this federal contract opportunity

Other files attached to SOF Human Performance Training Center, newest first.
File Type Posted
W912PM18R0003_-_04_SOF_HPTC_-_Mod.pdf PDF
W912PM18R0003_-_04_SOF_HPTC_-_Conform.pdf PDF
W912PM18R0003-03_SOF_HPTC_-_Amendment0003.pdf PDF
W912PM18R0003-03_SOF_HPTC_-_Conform.pdf PDF
A-002.pdf PDF
Amend_0002_PN79443_W912PM18R0003_Conformed.pdf PDF
Amendment_0002_PN79443.pdf PDF
Pre-bid_Sign-in_sheet_for_PN79443_HPTC.pdf PDF
W912PM18R00030001_Conformed_PN79443_SOF_HPTC.pdf PDF
W912PM18R00030001_PN79443_SOF_HPTC.pdf PDF
NAVFAC_USACE_PPQ.pdf PDF
PN79443_RTA_PLANS.pdf PDF
PN79443_RTA_DGNfiles.zip ZIP file
PN79443_RTA_V2_APPENDICES.pdf PDF
PN79443_RTA_REVITfiles.zip ZIP file
PN79443_RTA_V3_FFE.pdf PDF
PN79443_RTA_V1_SPECIFICATIONS.pdf PDF
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TD=60'-8"

ONE HOUR FIRE RATING

ACTUAL TRAVEL DISTANCE

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER BRACKET

FEC

FEB

DEAD END CORRIDOR

CP

DE

#### EST. EGRESS USAGE AT THIS DOOR

COMMON PATH OF TRAVEL

XXX

XXX ROOM NAME

NET SQUARE FOOTAGE

OCCUPANT LOAD FACTOR

OCCUPANT LOAD

XXX

XXX

NOMINAL WIDTH, IN

WIDTH FACTOR, IN/PERSON (*)

CALCULATED CAPACITY

REQUIRED EXIT CAPACITY TAG

OCCUPANT LOAD TAG

SHEET ID

D R

AW

N

B Y:

D

ES

IG

N

B Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

C H

EC

KE

D B

Y:

US Army Corps of Engineers ®

D

C

B

A

C

AT

EG

O

R Y

C O

D E:

AN

SI

D

E

F

G

2 3 4 5 6 7 8 9 10

C:\Users\K6ENDPJS\Documents\FY18PN79443_ARCH_R18_K6ENDPJS.rvt

10/3/2018 9:21:41 AM

JU

LY

W

2P M

-1 8-

R -0

D es ig ne r

Au th or

Ap pr ov er

1-

-1

A-001

BU

IL

D

IN

G C

O D

E

AN

AL

YS

IS

S U

M M

AR

Y

W

IL

M

IN

G

TO

N D

IS

TR

IC

T

D

AR

LI

N G

TO

N

A

VE

N U

E W

IL

IM

IN

G

TO

N

, N C

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SA

VA

N N

AH

D

IS

TR

IC

T

W . O

G

LE

TH

O

R

PE

A

VE

N U

E

SA

VA

N

N

AH

, G A

FO

R

T

BR

AG

G

, N O

R

TH

C

AR

O

LI

N A

SO

F

H U

M

AN

P

ER

FO

R

M

AN

C E

TR

AI

N

IN

G C

EN

TE

R (H

PT

C

FY

P

N

C he ck er

RTA

OCCUPANT GRAND TOTAL: 908 LS PLAN LEGEND

GROSS BUILDING AREA

OCCUPANT LOAD TAG

LIFE SAFETY/CODE ANALYSIS

REFERENCES:

-Unified Facilities Criteria- UFC 1-200-01 General Building Requirements, 30 June 2016 -Unified Facilities Criteria- UFC 3-600-01 Fire Protection Engineering for Facilities, 8 August 2016, change 1, 28 November 2016 -NFPA 101 Life Safety Code, 2015 Edition -NFPA 13, Standard for the installation of Sprinkler Systems -NFPA 10, Installation of Portable Fire Extinguishers -International Building Code, 2015 Edition

BUILDING DESCRIPTION:

One Story & Mezzanine ~56,400 square feet gross area and fully sprinklered.

The building will house exercise equipment for Soldier training to meet the Program of Instruction. The facility will include a double height space for Strengths Training, Multi-Purpose Training, Cardio Training and a Performance area as well as a floor and mezzanine of support spaces including both separated and shared Physical Therapy areas for the two separate user groups, Group Toilets and Showers, Hydrotherapy room with dedicated Mechanical Room and Laundry, area with Pass-thru for forklift delivery of equipment, Nutrition Education Room, Dietitian Office with Testing areas, Sports Psychologist offices, Strengths Training Offices, a Break Room / Training / Classroom with operable partition divider, F/A CAT TV Closet, Main T/R, Janitor’s closet, Electric room, Air Compressor Room, and a Mechanical room.

Occupancy per IBC:

Section 303.4 Assembly Group A-3 (Gymnasium without spectator seating);

Section 304.1: Business Group B

Construction Type per IBC:

Requirements for Construction Type IIA:

Table 504.3 Allowable Building Height:

Allowable: 55 feet standard. (85 feet if sprinklered) Actual Height: <50' to highest roof element

Table 504.4 Allowable number of stories above grade plane:

4 stories permitted maximum.

Actual # of stories: 1 (+Mezzanine)

Table 506.2 Maximum Building Area Allowable Area Factor: 38,000 sf per floor (A-3 | Sprinkled 1 Story) Actual area of first floor including canopy: 46,674 SF Actual area of mezzanine: 10,692 SF Section 506.2.2 Mixed occupancy, one-story buildings(IBC equation 5-1):

Allowable area per story can be maximum 45,125 sf.

Number arrived at by using equation 5-1, shown below:

A(a) = [A(t) + (NS x I(f))] A(t) = Table 506.2 value tabular allowable area factor S1 value is 62,000 sf NS = Table 506.2 value tabular allowable area factor NS value is 15,500 sf I(f) = Area factor increase due to frontage as calculated in accordance with Section 506.3 is .75 EQUATION 5-1: [62,000 + (15,500 x .75)] = 73,325 SF per floor.

SECTION 505 - MEZZANINES

Actual area of mezzanine: 10,219 SF Open area on first floor: 32,083 SF Percentage of first floor the mezzanine comprises:31.85% (1/3rd max.)

FIRE RESISTIVE RATING REQUIREMENTS

Fire Resistive rating requirements based upon construction Type IIA (Table 601): One hour rating required for primary structural frame, bearing walls (exterior and interior), floor construction and roof construction.

Fire Resistance rating requirements for exterior walls based upon Fire Separation distance (Table 602): No rating requirement if distance to imaginary property line is 30 feet or greater.

Maximum Area of Exterior wall openings based upon fire separation distance and degree of opening protection (705.8.1 exception 1.1): In other than Group H occupancies, unlimited unprotected openings are permitted in the first story above grade plane either: 1.1 Where the wall faces a street and has a fire seoparation distance of more than 15 feet.

Egress capacity (Table 7.3.3.1) level travel:

0.2 inch per person x 908 = 181.6 inches required.

PROVIDED: Actual level travel capacity: 363" clear.

NUMBER OF MEANS OF EGRESS: 7 (4 required from main A-3 spaces)

(2) at 33" clear, and (5) at 66" clear= 429" clear.

In assembly occupancies, the main entrance/exit shall be of a width that accommodates one half of the total occupant load (12.2.3.6.2). One half of the total occupant load 908 = 454 persons *.2= (90.8 inches required) 132 inches provided.

Interior wall and ceiling finishes materials shall be Class A, B in general assembly areas having occupant loads greater than 300 occupants (12.3.3.3).

Floor finish must be no less than Class II in exit access corridor and exit enclosures (12.3.3.5.2).

Portable fire extinguishers shall be provided (38.5).

Requirements per UFC 1-200-01 Special Detailed Requirements Based on Use and Occupancy- Use UFC 3-600-01 instead of IBC Chapter 4.

Requirements per UFC 3-600-01 -Complete automatic sprinkler protection must be provided in all new or renovated DOD Facilities (paragraph 4-2.2).

-Complete automatic sprinkler protection is provided for the entire building.

Requirements per NFPA 10 Classification of hazard for fire extinguishers:Light Hazard – minimum fire extinguisher rating 2-A, maximum of 75 feet travel to extinguisher (Table 6.2.1.1).

Extra Hazard - minimum fire extinguisher rating 80-B, maximum of 50 feet travel to extinguisher (Table 6.3.1.1).

Corridors: shall not be less than 44 inches wide (12.2.3.8).

Number of exits:

Minimum 2 per story required (7.4.1.1, 38.2.4, 12.2.4.1);

First floor: 5 provided.

Mezzanine: 2 provided.

(NOTE: Because the building is Mixed Occupancy, unseparated, the more stringent requirement rules. Both are shown here for reference) Maximum Travel Distance:

(Business) 300 feet (38.2.6.3);

(Assembly) 250 feet (12.2.6.2.1, Table A7.6)

Maximum Common path:

(Business) 100ft. (38.2.5.3.1);

(Assembly) 20 feet where the common path serves greater than 50 occupants (12.2.5.1.2, Table A7.6) (Assembly) 75 feet where the common path serves not more than 50 occupants (12.2.5.1.2, Table A7.6)

Maximum dead end:

(Business) 50 feet (38.2.5.2.1);

(Assembly) 20 feet (12.2.5.1.3, table A7.6)

Remoteness:

Shall be provided in accordance with 7.5.1.3.7 through 7.5.1.3.7. In buildings protected throughout by an approved, supervised automatic sprinkler system, the minimum separation between two exits, exit accesses, or exit discharges, shall not be less than one third the length of the maximum overall diagonal dimension of the building or area to be served.

Maximum diagonal = 288' .

Minimum required separation = 96'.

Protection per NFPA 101 Corridor and lobby protection is not required in buildings protected throughout by an approved supervised automatic sprinkler system (12.3.6.2)(38.3.6.1(3))

Boiler and Furnace rooms require one hour fire separation or automatic sprinkler protection (12.3.2.1.2.1a).

Recycled materials storage room, General storage room require one hour fire separation or automatic sprinkler protection (12.3.2.1.2 (1) b).

Recycled materials storage room, General storage room without fire separation, including automatic sprinkler protection shall have smoke partitions (8.7.1.2).

IT IS THE DESIGN BUILD CONTRACTOR'S

RESPONSIBILITY TO PROVIDE FULLY

CODE/CRITERIA COMPLIANT DESIGNS AND

CONSTRUCTED FACILITY. IT IS THE DESIGN BUILD

CONTRACTOR'S RESPONSIBILITY TO AMEND

ERRORS AND CODE VIOLATIONS FOUND IN THIS

RFP.

OCCUPANCY LOAD SCHEDULE - BUSINESS (B)

Name Occ. Type Area Load

Factor

CALCULATED

LOAD

Occ. Load Rounded

PT COMMON AREA B 2469 SF 100 24.69 25

3RD SFG B 1240 SF 100 12.40 13

95TH CA B 1276 SF 100 12.76 13

HYDROTHERAPY ROOM B 1493 SF 100 9.92 10

LAUNDRY B 154 SF 500 0.31 1

T/COM B 121 SF 500 0.20 1

TOIL-M B 731 SF 100 7.68 8

J B 55 SF 500 0.11 1

TOIL-W B 434 SF 100 4.34 1

ELECTRICAL ROOM B 453 SF 500 0.91 1

ENTRY B 557 SF 100 5.57 6

VESTIBULE B 146 SF 100 1.47 2

CIRCULATION B 1482 SF 100 14.83 15

AIR/C B 25 SF 500 0.05 1

Grand total: 14 10637 SF 95.23 98

OCCUPANCY LOAD SCHEDULE - ASSEMBLY (A-3)

Name Occ. Type Area Load

Factor

CALCULATED

LOAD

Occ. Load Rounded

PERFORMANCE AREA A-3 1057 SF 50 19.94 20

CARDIO TRAINING AREA A-3 7387 SF 50 118.80 119

MULTI-PURPOSE TRAINING AREA A-3 9915 SF 50 199.34 200

STRENGTH TRAINING AREA A-3 11144 SF 50 223.50 224

Grand total: 4 29503 SF 561.58 563

BUILDING AREA = 56,706 SQ FT.

OCCUPANCY LOAD SCHEDULE - BUSINESS (B) MEZZANINE

Name Occ. Type Area Load

Factor

CALCULATED

LOAD

Occ. Load Rounded

EL LANDING B 124 SF 15 8.27 9

NUTRITION ED & TESTING ROOM B 755 SF 15 46.73 47

DIETITIAN OFFICES B 404 SF 100 4.59 5

STRENGTHS TRAINING OFFICE B 1284 SF 100 12.84 13

SP. PSY. 1 B 151 SF 100 4.63 5

CLASSROOM B 723 SF 15 48.20 49

BREAK/CONF. RM B 679 SF 15 45.27 46

TOILET-F B 191 SF 100 1.92 2

CIRCULATION / BALCONY B 2005 SF 100 20.06 21

SP. PSY. 2 B 147 SF 100 4.63 5

TRAINING STEPS/LANDING B 258 SF 100 2.59 3

RAMP 20 DEGREE B 318 SF 100 3.19 4

RAMP 7 DEGREE B 939 SF 100 9.39 10

TOILET -M B 289 SF 100 2.89 3

Grand total: 14 8269 SF 215.20 222

OCCUPANT GRAND TOTAL: 908

Means of Egress per NFPA 101 Occupancy per NFPA 101:

Assembly (Chapter 12), Business (Chapter 38)

OCCUPANCY/USE

Refer to Schedules on this sheet

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

R

EV

IS

ED

IN

A C

C O

R D

AN

C

E W

IT

H

A M

EN

D

M

EN

T

O C

T2

OCCUPANCY LOAD SCHEDULE - STORAGE(S)

Name Occ. Type Area Load

Factor

CALCULATED

LOAD

Occ. Load Rounded

STORAGE 3 S 614 SF 500 1.40 2

STORAGE1 S 474 SF 500 0.25 1

HYDRO - MECHANICAL ROOM S 495 SF 500 0.99 1

MECHANICAL ROOM S 1431 SF 500 2.86 15

STORAGE5 S 132 SF 500 0.27 1

MECHANICAL S 593 SF 500 1.98 2

STORAGE S 103 SF 500 1.02 2

T/COM S 121 SF 500 0.24 1

Grand total: 8 3963 SF 9.01 25

Sheets
A-001 - BUILDING CODE ANALYSIS & SUMMARY