BuildingH2313_Ft._Bragg_PN_89035.pdf
PDF 38 MB Posted
- Attached to
- PN 89035 SOF TRAINING BUILDING H-2313
- Solicitation number
- W912PM-17-R-0010
About this file
PLANS - PN89035
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Example_2_Key_Personnel.docx | DOCX document | |
| W912PM-17-R-0010-0001_PN89035_SF-30.pdf | ||
| Example_3_Past_Performance.docx | DOCX document | |
| W912PM-17-R-0001-0001_PN89034_Conformed.pdf | ||
| Example_1_Past_Experience.docx | DOCX document | |
| BXCET601.pdf | ||
| A23.)_PN_89035_Site_Visit_Sign_In_Sheet.pdf | ||
| RTA_SPECS.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nancy Snapshot
GL-6
DRAWING ABBREVIATIONS
MATERIAL LEGENDA ---------------------
A/E ARCHITECT/ENGINEER
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL
SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH
DISABILITIES ACT
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ALUM ALUMINUM
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
B ---------------------
BD BOARD
BDRY BOUNDARY
BHMA BUILDER'S HARDWARE
MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
CAV CAVITY
CBB CEMENTITIOUS (BACKER)
BOARD
CD CONSTRUCTION
DOCUMENTS
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED
/CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL
FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CU FT CUBIC FEET
D ---------------------
D DEPTH
dB DECIBEL
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
EA EACH
EIFS EXTERIOR INSULATION
AND FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR
PANEL
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF EL FINISH FLOOR ELEVATION
FGL FIBERGLASS
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLG FLOORING
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED
WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GA GAGE/GAUGE
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED
FURNISHED INSTALLED BY
GOVERNMENT
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GHZ GIGAHERTZ
GLZ GLAZING
GUT GUTTER
GYP BD GYPSUM BOARD
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY
POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBS POUND
LIB LIBRARY
LIN LINEAR
LOC LOCATION
LT LIGHT
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MFR MANUFACTURER
MHZ MEGAHERTZ
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
STC SOUND TRANSMISSION
COEFFICIENT
STD STANDARD
STL JST STEEL JOIST
STOR STORAGE
STRB/HRN STROBE/HORN
T --------------------
T TREAD
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
THK THICKNESS
TN TRUE NORTH
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
V --------------------
VCT VINYL COMPOSITION TILE
W --------------------
W/ WITH
MOD MODIFY
MTG MOUNTING
MTL METAL
MWP MEMBRANE
WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE
PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OWSJ OPEN WEB STEEL JOIS
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RM ROOM
RO ROUGH OPENING
RV ROOF VENT
RVL REVEAL
S --------------------
SAFB SOUND ATTENUATION
FIRE BATTS
SAR SITUATION AWARENESS
ROOM
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SGL SINGLE
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SL SLOPE
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
ACCESSORY BY MARK A
12345X
Name
Elevation
ROOM NAME
150 SF
A202
SIM
1/8" = 1'-0"
VIEW NAME
A1ST
1t
NORTH ARROW
SQUARE FOOTAGE
ROOM NUMBER
ROOM NAME
VIEW NUMBER
VIEW NUMBER
VIEW NAME
VIEW SCALE
WALL TAG
WINDOW TAG
DOOR TAG
LEVEL
MARK
SHEET NUMBER
SIMILAR TAG
DETAIL LOCATED ON SHEET
(MAY ALSO BE REF. UNDER
TITLE FOR MULTIPLE SHEETS)
SIMILAR TAG
ELEVATION RELATIVE TO FIRST
FLOOR FIN. FLR.
FLOOR/LEVEL NAME
BUILDING SECTION
99 SIM
AE101
99 SIM
AE101
DETAIL CALL-FROM SHEET (IF USED)
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
N
TRUE NORTH 20°
FROM PLAN NORTH
PLAN NORTH INDICATOR
TRUE NORTH
MATCHLINE 11/ AE-101.A1
MATCH LINE
NUMBER ON
MATCHING SHEET
CONTINUATION SHEET
NOTE: 'CALL-FROM' REFERENCES ONLY REFER TO
ORIGINAL CALLOUT, 'SIM' CONDITIONS ARE NOT INCLUDED
DETAIL LOCATED
ON SHEET
AE101
A
VIEW IDENTIFIER
FURNITURE/EQUIP.
BY MARK
ROOM TAG WITH SQUARE FOOTAGES*
DETAIL CALLOUT
CALLOUT - DETAILS (BACK REFERENCES)
ELEVATION
MATCH LINE
VIEW TITLE
SIM
SIMILAR TAG
SIM
B
A202
SIM
A202
SIM
______________VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
WALL SECTION
99 SIM
AE101
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
DETAIL CALLOUT
GRID HEAD - EXISTING
FINISH EXTENTS
VIEW NUMBER
SHEET NUMBER
SIMILAR TAG
BUILDING ELEVATION
VIEW NUMBER
XXXXX
999Z
KEYED NOTE - DEMO
(SHEET)
05 HANDRAIL
KEYED NOTE- DEMO
LEGEND
NOTE ASSOCIATED
WITH KEYED COMMENT
XXXSPECIALTY EQUIP.
TARGET "AFF FIRST FLOOR"
"TARGET"
SPOT ELEVATION W/
REF TO FIN. FLR.
FINISH ID
Name
Elevation
EXTENT OF DETAIL
KEYED NOTE - NEW
(SHEET)
03 VISUAL SCREEN
KEYED NOTE - NEW
LEGEND
NOTE ASSOCIATED
WITH KEYED COMMENT
C
D
0'-0"
FIN. FLR.
EARTH - COMPACTED
FILL
CONCRETE
BRICK - MASONRY
STEEL
PLYWOOD
RIGID INSULATION
BATT INSULATIONFINISHED WOOD
BLOCKING
CONTINUOUS WOOD
CONCRETE MASONRY
UNIT (PLAN)
CONCRETE MASONRY
UNIT (SECTION)
GLASS MAT
SHEATHING
SPRAY-FOAM
INSULATION
SAND, FIREPROOFING,
MORTAR, GROUT,
PLASTER, DRYWALL
ARCHITECTURAL SYMBOLS LEGEND
A202
SIM
PREFORMED SEALANT
AE101
1/4" = 1'-0"
VIEW SCALE
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
/1
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
-0
.D
G N
A-001
T F
A B
B R
E V
I A T
IO
N
S A
N D
L E
G E
N D
S
A -0
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
C E
N T
E R
O F
L E
V E
R
MORTISE LOCK
MOUNTING HEIGHT
C E
N T
E R
O F
P A
N
IC
B A
R
PANIC BAR
MOUNTING HEIGHT
PUSH PULL
MOUNTING HEIGHT
COAT HOOK
MOUNTING HEIGHT
CENTER LINE OF DOOR
COAT HOOK
'-3
'-3
/8
'-6
'-0
S
T A
N D
A R
D
'-0
A
D A
C E
N T
E R
O F
K E
Y P
A D
C
A R
D R
E A
D E
R
KEYPAD / CARD
READER HEIGHT
'-0
NOTE: Y=48"
MIN IF DOOR
HAS A CLOSERNOTE:
X=12" IF
DOOR HAS
BOTH A
CLOSER AND
A LATCH.
NOTE: X=36" MIN IF Y=60"
NOTE: X=42" MIN IF Y=54"
NOTE: Y=48"
MIN IF DOOR
HAS BOTH A
CLOSER AND
A LATCH.
NOTE: Y=54" MIN
IF DOOR HAS CLOSER
'-0
1'-6" (24" PREFERRED)
X
'-6
Y
'-6
4'-6"
Y
'-6
2'-0"
X
3'-6"
Y
'-6
Y
'-0
2'-0"
FIRE
EXTINGUISHER
CABINET
FIRE
VALVE/
FIRE HOSE
CABINET
ELECTRICAL/
COMMUNICATIONS
PANEL
BOARD
FIRE
DETECTION
PANEL
AUDIBLE
FIRE
ALARM &
STROBE
ACCESS
DOOR
C .L
H
A N
D L E
'-0
C .L
H
A N
D L E
'-0
" 6 '-0
'-0
'-2
" 6 '-8
LANDING RAMP RUN LANDING
60" min 60" min
AT LEAST AS WIDE AS RAMP RUN
"-3
12" min 12" min
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
/4
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
K M
B
R S
M P
B X
C A
-0
.D
G N
A-002
T F
T Y
P
IC
A L M
O U
N T
I N G
H E
IG
H
T S
A -0
A-002 1/4" = 1'-0"
1 ADA-DOOR HARDWARE MOUNT HEIGHTS
A-002 1/4" = 1'-0"
2 ADA-CLEARANCES FOR DOORS WITH CLOSERS & LATCHES
A-002 1/4" = 1'-0"
3 ADA-DOD-PANEL MOUNTING HEIGHTS
A-002 1/4" = 1'-0"
4 ADA RAMP DETAILS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
1.22 2 3 4
A.5
C
B.3
D
3.4
B.9
2.2
B.7
1.35
OFFICE
SERVER ROOM
G-2
G-2
PO
PO
PO
PO
G3/S3 STO
SCI / VTC
CONFERENCE
SCIF
VESTIBULE
OFFICE
OFFICE
OFFICE
G-3
OFFICE
OFFICE
PANTRY/BREAK
AREA
CONFERENCE
ROOM
PLANS DIV
TRNG DIV /
OPS DIV
OFFICE
OFFICE
OPS
ELEV.
MACHINE
ROOM
ELEVATOR
COMM.
SIPR
LANGUAGE
LAB
RECYCLING
COPY
STORAGE
OFFICE
TREATMENT
RM
OFFICE
OFFICE
WOMEN'S
TOILET
MEN'S TOILET
JANITOR
COMSEC
LANGUAGE
LAB G
MECHANICAL
ELECTRICAL
MEDICAL SVC
ELEC
009 CORR
LANGUAGE
LAB A
LANGUAGE
LAB B
LANGUAGE
LAB C
LANGUAGE
LAB D
LANGUAGE
LAB E
LANGUAGE
LAB F
SCIF
CORRIDOR
STAIR
LIMIT OF
WORK 060401
05 07
CORR
CORR
MOVABLE
PARTITION
MOVABLE
PARTITION
MOVABLE
PARTITION
030202
KEYNOTE LEGEND:
EXISTING CORRIDOR SECONDARY WORK AREA
WITH WALL PAINTING SCOPE ONLY.
CONTRACTOR ONLY ACCESS TO THE BUILDING
THROUGHOUT THE CONSTRUCTION PERIOD
04 CONTRACTOR PRIMARY WORK AREA
LANGUAGE LAB SPACES 610, 611, 612, AND 613:
CONTRACTOR AVAILABLE OPTION FOR SECURE
STORAGE AND FIELD OFFICE SPACE DURING THE
CONSTRUCTION PERIOD. PROTECTION TO
EXISTING FINISHES AND MOVEABLE PARTITIONS
REQUIRED.
02 EXISTING EXTERIOR BOLLARDS
03 EXISTING EXTERIOR LIGHT POLE
TEMPORARY ISOLATION IS ACCOMPLISHED WITH
DUST PARTITION FOR DURATION OF
CONSTRUCTION PERIOD. PARTITION TO STOP AT
EXISTING CEILING AND SHALL BE FINISHED WITH
PAINTED GYP. BD. AND RUBBER WALL BASE TO
MATCH EXISTING CORRIDOR ON
NON-CONSTRUCTION SIDE OF THE WALL.
DUST PARTITION SHALL HAVE AN ACCESS DOOR.
WOOD DOOR AND FRAME FROM ROOM # 602 CAN
BE REUSED. DOOR SHALL HAVE HARDWARE WITH
CYLINDER LOCK. A PANIC (CRASH) BAR SHALL BE
LOCATED ON THE CONTRACTOR SIDE OF THE
PARTITION FOR A SECOND POINT OF CONTRACTOR
EMERGENCY ERESS
LEGEND:
CONTRACTOR PRIMARY WORK AREA
CONTRACTOR AVAILABLE OPTION FOR
SECURE STORAGE AND FIELD OFFICE SPACE
DURING THE CONSTRUCTION PERIOD
EXISTING CORRIDOR SECONDARY WORK
AREA WITH WALL PAINTING SCOPE ONLY. SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
S L J
T F
B X
C A
-0
.D
G N
A-003
T F
O V
E R
A L L B
A S
E M
E N
T F
L O
O R
P L A
N E
X
IS
T
IN
G
A -0
A-003 1/8" = 1'-0"
1 OVERALL BASEMENT FLOOR PLAN EXISTING
0" 4'-0" 8'-0" 16'-0"
1/8"=1'-0"
N
TRUE NORTH 20°
FROM PLAN NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
DN DN
2 3 4
C
B.3
D
3.4
B.9
2.2
B.7
EXIST. ELEC
OFFICE
OFFICE
OFFICE
JANITOR
WOMEN'S
TOILET
MEN'S TOILET
EXIST.
MEDICAL SVC
EXIST. CORR
EXISTING STAND PIPE
Room Capacity:
28 Fixed Work Stations 14 Viewing Seats
0'-8"
EQUIP. ROOM
ø 5'-0
0'-4" 0'-8" ø 5'-0
0'-8"
VESTIBULE
0'-4"
C O
M M
O N
T R
A V E L
P A T H
D
IS
TA
N
C E
' 1
DISTANCE TO EGRESS
DISCHARGE - 106' 6"
EXIST. CORR
EXIST. CORR
1" / 12"
RAMP
4'-0"
RAMP
4'-0"
LANGUAGE
LAB A
LANGUAGE
LAB B
LANGUAGE
LAB C
LANGUAGE
LAB D
LANGUAGE
LAB E
LANGUAGE
LAB F
F.E.C.
TEMPORARY DUST PARTITION
SECURE AREA
30'-7"
108' TO NEAREST EXIT
1" / 12"
CODES
CONTRACTOR IS TO ENSURE USAGE OF THE LATEST EDITION OF THE
CODES LISTED BELOW.
INTERNATIONAL BUILDING CODE, 2015
NATIONAL FIRE PROTECTION ASSOCIATION - NFPA 13, 24, 101
AMERICAN WITH DISABILITIES ACT ACESSIBILITY DESIGN GUIDELINES
FOR BUILDINGS AND FACILITIES, 2010UFC - 3-600-01 FIRE PROTECTION
ENGINEERING FOR FACILITIES
UFC - 4-021-01 DESIGN AND O&M: MASS NOTIFICATION SYSTEMS
UFC - 4-010-05 SENSITIVE COMPARTIMENTED INFORMATION FACILITIES,
PLANNING, DESIGN AND CONSTRUCTION
BUILDING CODE EVALUATION
OCCUPANCY BASEMENT LEVEL ONLY
BUSINESS GROUP - GROUP B, BUSINESSES - OFFICES (304)
ASSEMBLY GROUP - GROUP A, ASSEMBLY - ASSEMBLY (303)
CONSTRUCTION TYPE
IIB (CHAPTER 6) WITH AUTOMATIC SPRINKLER SYSTEM
FIRE RESISTIVE OF BUILDINGS ELEMENTS (TABLE 601)
STRUCTURAL FRAME: 0HR
EXTERIOR BEARING WALLS: 0HR
INTERIOR BEARING WALLS: 0HR
NON BEARING WALLS AND PARTITIONS INTERIOR: 0HR
FLOOR CONSTRUCTION: 0HR
ROOF CONSTRUCTION: 0HR
MAX. AREA OF EXT WALL OPENINGS(705.8): NO LIMIT
EXTERIOR WALL FIRE RESISTANCE FOR SEPERATION
LESS THAN 5FT: 1HR
BETWEEN 5FT AND 10FT: 1HR
BETWEEN 10FT AND 30FT: 0HR
GREATER THAN 30FT: 0HR
ALLOWABLE HEIGHT (TABLE 504.3): 75FT MAX.
ALLOWABLE NUMBER OF FLOORS(TABLE 504.4):
4 STORIES MAX. ABOVE GRADE PLANE
ALLOWABLE AREA PER FLOOR(TABLE 506.2): 23,000 SF
ALLOWABLE AREA WITH SPRINKLERS AND
FRONTAGE INCREASE: 82,250 SF MAX PER FLOOR
SF MAX PER FLOOR
ACTUAL AREA (SF):
BASEMENT: 21,108 SF
FIRST FLOOR: 21,718 SF
SECOND FLOOR: 21,699 SF
THIRD FLOOR: 16,252 SF
TOTAL AREA: 80,777 SF
EGRESS ARRANGEMENT, INTERIOR FINISH AND EXIT CAPACITY IS
BASED ON NFPA 101, LIFE SAFETY CODE
LIFE SAFETY CODES EVALUATION
OCCUPANCY
UNSEPERATED MIXED USE
CHAPTER 39, EXISTING BUSINESS OCCUPANCIES
EGRESS CAPACITY (39.2.3) AND NUMBER OF EXITS (39.2.4)
2 DOORS @ 34" CLEAR = 68 INCHES
1 DOOR @ 68" CLEAR = 68 INCHES
136/*0.2 INCHES PER OCCUPANT = 680 OCCUPANTS
EGRESS ARRANGEMENT (39.2.5) WITH SPRINKLER SYSTEM
DEAD END CORRIDOR: 50FT
COMMON PATH OF TRAVEL: 100FT
TRAVEL DISTANCE: 300FT
EXIT LIGHTING (39.2.10): PROVIDED
PROTECTION OF VERTICAL OPENINGS (39.3)
EXTINGUISHMENT (39.3.5): COMPLETE SPRINKLER PROTECTION
SYSTEM AND PORTABLE FIRE EXTINGUISHER PROVIDED
CORRIDORS (39.3.6): NO REQUIREMENTS
EGRESS REQUIREMENTS - PER USAGE
BASEMENT FLOOR
ASSEMBLY OCCUPANCY 1:15 SF GROSS
ASSEMBLY OCCUPANCY 1:7 SF GROSS
BUSINESS OCCUPANCY 1:100 SF GROSS
EDUCATION OCCUPANCY 1:20 SF NET
STORAGE OCCUPANCY 1:500 SF GROSS
STORAGE + BACK OF HOUSE AREAS
TOTAL
AREA (SF)
693 SF
13,287 SF
3,812 SF
3,316 SF
21,108 SF
OCCUPANT LOAD
OCCUPANT LOAD
NFPA 101, TABLE 7.3.1.2:
GROUP B: 1 PERSON / 100 GROSS SF
GROUP A-3: 1 PERSON / 15 NET SF LESS CONCENTRATED
USE INCLUDING TABLES WITHOUT FIXED SEATS.
GROUP E (CLASSROOM): 1 PERSON / 20 NET SF
ACCESSORY AREAS: 1 PERSON / 500 GROSS SF
OCCUPANT LOAD PER FLOOR (EXISTING)
BASEMENT 383 OCCUPANTS
FIRST FLOOR 247 OCCUPANTS
SECOND FLOOR 248 OCCUPANTS
THIRD FLOOR 225 OCCUPANTS
TOTAL 1103 OCCUPANTS
LEGEND:
TRAVEL PATH
NEW EXIT SIGN
EXISTING EXIT SIGN
F.E.C.
WALLS TO REMAIN
NEW PARTITIONS
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
-0
.D
G N
A-004
T F
P A
R T
IA
L B
A S
E M
E N
T F
L O
O R
P L A
N L
IF
E S
A F
E T
Y
A -0
A-004 1/4" = 1'-0"
PARTIAL BASEMENT LIFE SAFETY FLOOR PLAN FOR RENOVATED
SPACE
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
KEY PLAN:
N
TRUE NORTH 20°
FROM PLAN NORTH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
B.3
D
3.4
B.9
2.2
B.7
AD101
_______ 6
AD101
AD101
AD101
/4
'-9
/8
'-3
/8
'-0
/8
'-2
/8
'-2
'-8
/8
/8
'-7
/8
'-1
21'-1 7/8" 2'-1 7/8" 5'-4 7/8"
2 1/2"
10'-1 5/8"
2 1/2" 2'-9 5/8" 18'-7 3/8" 7'-7 3/8"
1 7/8"
10'-1 5/8"
AD101
EXIST.
ELECTRICAL
EXIST.
MECHANICAL
EXIST. CORR
EXIST. CORR
EXIST. ELEC
EXIST.
MEDICAL SVC
9'-1 1/8" 2'-5" 3'-8" 2'-8 1/4" 3'-6 1/2"
'-0
'-5
'-0
'-5
'-5
EXIST.
STORAGE
EXIST.
OFFICE
EXIST.
LANGUAGE LAB
EXIST.
RECYCLING
EXIST.
COPY
A L
IG
N D
E M
O
AD101
SIM
AD101
SIM
5'-11 3/4" 3'-4 1/4" 10 7/8"
8'-9 1/4"
'-0
'-0
'-0
EXISTING TO
REMAIN
EXISTING TO BE
DEMOLISHED
DEMOLITION LEGEND: DEMOLITION NOTES: (AD101/AD102)
REMOVE GYP. BD, METAL STUDS TO REMAIN, EXISTING INSULATION TO
REMAIN, PATCH AS NEEDED.
02 DEMOLISH WALL FOR NEW DOOR.
03 COMPLETELY DEMOLISH WALL.
REMOVE DOOR AND FRAME, PREP FOR INFILL FRAMING. TURN OVER TO
GOVERNMENT.
05 REMOVE VCT FLOOR FINISH AND RUBBER WALL BASE.
06 REMOVE CARPET FLOOR FINISH AND RUBBER WALL BASE AND PREP FOR NEW.
EXTERIOR WINDOWS AND FRAMES TO REMAIN, REMOVE BLINDS, INTERIOR
GYP. BD RETURNS AND INTERIOR WINDOW SILL.
REMOVE ACOUSTIC CEILING TILE, SUSPENDED CEILING GRID, AND HANGERS.
PREP SURFACES TO RECEIVE NEW ACOUSTIC CEILING TILE AND GRID.
REMOVE GYP. BD CEILING AND FRAMING. PREP SURFACES TO RECEIVE NEW
ACOUSTIC CEILING TILE AND GRID.
CAREFULLY SAWCUT AND REMOVE CONCRETE SLAB FOR CONDUIT AND
FLOOR BOX. SEE ELECTRICAL DRAWINGS SHEETS EP101 AND ET101 FOR
ADDITIONAL INFORMATION.
11 REMOVE DOOR AND FRAME. TURN OVER TO GOVERNMENT.
SALVAGE DOOR, FRAME, AND HARDWARE. REUSE FOR TEMPORARY
PARTITION. REFER TO SHEET A-003.
TEMPORARY PARTITION. 5/8" GYP BD ON 3 5/8" METAL STUD @16 O.C. UP TO
THE EXISTING CEILING. GYP. BD TO BE FINISHED AND PAINTED TO MATCH
EXISTING CORRIDOR. CYLINDER LOCK AND CRASH BAR HARDWARE. REFER TO
SHEET A-003.
EXISTING
BASEMENT
0' - 0"
AD101
01 0211
03 03
'-6
2 SIM
AD101
04 03
2.2
EXISTING WALL (STC 45):
5/8" TYPE "X" GYP. BD, 3 5/8"
METAL STUD @ 16" OC WITH
3" SAFB, 5/8" TYPE "X" GYP.
BOARD
REMOVE EXISTING GYP. BD ON
ROOM 0600 SIDE.
REMOVE ALL IN-WALL
INFRASTRUCTURE FEEDING INTO
ROOM 0600 SIDE. RE-INSTALL
EXISTING INSULATION
EXISTING WALL: SPLIT FACE
CMU VENEER, 2" AIR GAP,
RIGID INSULATION (R-8 MIN),
5/8" EXT. GYP BD
SHEATHING, 6" METAL
STUDS @ 16" OC W/ BATT
INSULATION (R-19 MIN),5/8"
GYP. BD
REMOVE EXIST. GYP. BD.
VERIFY EXISTING FURRING
STRIPS ARE 16 GA. - INSPECT
(IF NOT, NOTIFY COR FOR
DIRECTION)
REMOVE ALL IN-WALL
INFRASTRUCTURE FEEDING
INTO ROOM 0600 SIDE. RE-
INSTALL EXISTING INSULATION
B.3
EXISTING WALL (STC 42):
5/8" TYPE "X" GYP. BD, 3 5/8"
METAL STUD @ 16" OC W/ 1
1/2" WOOL BATTS, 5/8" TYPE
"X" GYP. BOARD
REMOVE EXIST. GYP. BD. ON
ROOM 0015 SIDE
REMOVE ALL IN WALL
INFRASTRUCTURE FEEDING
INTO ROOM 0015 SIDE.
RE-INSTALL EXISTING
INSULATION.
B.3
EXISTING WALL (STC 45): 5/8"
TYPE "X" GYP. BD (2 LAYERS),
3 5/8" METAL STUD @ 16" OC,
5/8" TYPE "X" GYP. BD (2 LAYERS)
REMOVE EXIST. GYP. BD.
ON ROOM 0033 SIDE
REMOVE ALL IN WALL
INFRASTRUCTURE FEEDING
INTO ROOM 0033 SIDE.
REINSTALL EXISTING
INSULATION.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
D .D
G N
AD101
T F
P A
R T
IA
L B
A S
E M
E N
T F
L O
O R
P L A
N D
E M
O L
IT
IO
N
A D
AD101 1/4" = 1'-0"
1 PARTIAL BASEMENT FLOOR PLAN DEMO
N
TRUE NORTH 20°
FROM PLAN NORTH
AD101 1/4" = 1'-0"
6 PARTIAL BASEMENT DEMO SECTION
AD101, AD102
AD101 3/4" = 1'-0"
2 WALL DEMO DETAIL
AD101
AD101 3/4" = 1'-0"
4 WALL DETAIL DEMO
AD101
AD101 3/4" = 1'-0"
3 WALL DETAIL DEMO
AD101
AD101 3/4" = 1'-0"
5 WALL DETAIL DEMO
AD101
KEY PLAN:
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
DEMOLITION NOTES: (AD101/AD102)
REMOVE GYP. BD, METAL STUDS TO REMAIN, EXISTING INSULATION TO
REMAIN, PATCH AS NEEDED.
02 DEMOLISH WALL FOR NEW DOOR.
03 COMPLETELY DEMOLISH WALL.
REMOVE DOOR AND FRAME, PREP FOR INFILL FRAMING. TURN OVER TO
GOVERNMENT.
05 REMOVE VCT FLOOR FINISH AND RUBBER WALL BASE.
06 REMOVE CARPET FLOOR FINISH AND RUBBER WALL BASE AND PREP FOR NEW.
EXTERIOR WINDOWS AND FRAMES TO REMAIN, REMOVE BLINDS, INTERIOR
GYP. BD RETURNS AND INTERIOR WINDOW SILL.
REMOVE ACOUSTIC CEILING TILE, SUSPENDED CEILING GRID, AND HANGERS.
PREP SURFACES TO RECEIVE NEW ACOUSTIC CEILING TILE AND GRID.
REMOVE GYP. BD CEILING AND FRAMING. PREP SURFACES TO RECEIVE NEW
ACOUSTIC CEILING TILE AND GRID.
CAREFULLY SAWCUT AND REMOVE CONCRETE SLAB FOR CONDUIT AND
FLOOR BOX. SEE ELECTRICAL DRAWINGS SHEETS EP101 AND ET101 FOR
ADDITIONAL INFORMATION.
11 REMOVE DOOR AND FRAME. TURN OVER TO GOVERNMENT.
SALVAGE DOOR, FRAME, AND HARDWARE. REUSE FOR TEMPORARY
PARTITION. REFER TO SHEET A-003.
TEMPORARY PARTITION. 5/8" GYP BD ON 3 5/8" METAL STUD @16 O.C. UP TO
THE EXISTING CEILING. GYP. BD TO BE FINISHED AND PAINTED TO MATCH
EXISTING CORRIDOR. CYLINDER LOCK AND CRASH BAR HARDWARE. REFER TO
SHEET A-003.
ACOUSTIC CEILING
TILE TO REMAIN
DEMOLITION LEGEND:
ACOUSTIC CEILING TILE
TO BE DEMOLISHED
GYPSUM BOARD
CEILING TILE TO BE
DEMOLISHED
2 3 4
C
B.3
D
3.4
B.9
2.2
B.7
AD101
EXIST.
ELECTRICAL
EXIST.
MECHANICAL
EXIST. CORR
EXIST. CORR
EXIST. ELEC
EXIST.
MEDICAL SVC
8'-6"
8'-6"
8'-6"
8'-6"
8'-6"09
8'-6"
8'-6"
EXIST.
STORAGE
EXIST.
OFFICE
EXIST.
LANGUAGE LAB
EXIST.
RECYCLING
EXIST.
COPY
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
S L J
T F
B X
C A
D .D
G N
AD102
T F
P A
R T
IA
L B
A S
E M
E N
T R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N D
E M
O L
IT
IO
N
A D
- AD102 1/4" = 1'-0"
1 PARTIAL BASEMENT REFLECTED CEILING PLAN DEMOLITION
N
TRUE NORTH 20°
FROM PLAN NORTH
KEY PLAN:
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
C
B.3
D
3.4
B.9
2.2
B.7
EXIST. ELEC
EXIST.
MEDICAL SVC
EXIST.
ELECTRICAL
0'-0"
0'-0"
0'-0"
0'-8"
EQUIP. ROOM
0'-4" 0'-8"
0'-8"
VESTIBULE
16'-4 1/8" 4'-0" 5'-0" 4'-0" 9'-3"
2 3/8" 16'-7 3/4" 4'-6 3/4" 3'-5 3/8" 4'-3 7/8" 4'-7 3/8" 1'-4 5/8" 3'-4" 1'-2 1/2" 6'-1 5/8"
'-5
/8
'-0
'-0
'-8
'-5
/8
/-1 '-4
'-2
'-7
'-6
/4
" 0'-4"
AE301
_______ 2
AE301
AE301
AE301
AE401 3
AE301
_______ 3
AE301
AE602
AE602
11 5/8"
2'-8" 3'-4" 3'-6 7/8"
1 7/8"
21'-4 7/8" 7'-9 1/8" 16'-8"
'-7
/4
45'-10"
AE602
3'-2" 9'-3 3/4" 2'-6 3/4" 8'-10 1/2"03
'-9
02 02
AE302
AE302
AE302
AE602
AE602
R A
M P
DN
RAMP RAMP
EXIST. CORR
EXIST. CORR
1" / 12"
'-1
/8
'-0
'-0
'-3
/8
'-6
/4
'-7
/2
0'-0"
0'-0"
AE602
7'-4 1/2" 4'-0" 10'-0 3/8" 1'-3 5/8" 4'-0" 2'-5 1/2" 5'-6 1/2" 4'-0" 1'-0" 6'-1 5/8"
45'-10"
J
J
J
J
J
J
J
J
J
J
J J
J
J
J
SECURE AREA
JJ J
11 11
8'-4 1/8" 8'-0" 8'-0" 14'-3"
0'-8"
J
AE601
1" / 12"
GENERAL NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUDS, COLUMN
GRID OR CMU WALLS UNLESS OTHERWISE NOTED.
2. SEE SHEET AE601 FOR DOOR SCHEDULE.
3. SEE SHEET I-601 FOR FINISHES.
4. FOR ALL FURNITURE AND EQUIPMENT, SEE I-101.
5. COORDINATE LOCATION OF ADDITIONAL FRAMING AS
REQUIRED FOR SUPPORTING EQUIPMENT HANGING
FROM CEILING & STUD WALLS.
EXISTING PERIMETER STUD WALL TO REMAIN.
NON-SECURE SIDE: THE GYPSUM BOARD LAYER
AND THE EXISTING IN-WALL INFRASTRUCTURE
FEEDING THE NON-SECURE SIDE SHALL REMAIN IN
PLACE. SECURE SIDE: THE GYPSUM BOARD ON THE
SECURE SIDE AND IN-WALL INFRASTRUCTURE
FEEDING INTO THE SECURE SIDE SHALL BE
REMOVED. REPLACE GYPSUM BOARD AND SEAL
ALL OPENINGS. REFER TO ELECTRICAL DRAWINGS.
KEYNOTE LEGEND:
INFILL FRAMING REQUIRED IN OPENINGS, SEE
DETAIL 1/AE302.
03 EXISTING STANDPIPE.
INSTALL CONDUIT AS REQUIRED AND INFILL CUT
TRENCH WITH CONCRETE TO MATCH EXISTING,
SEE ELECTRICAL DRAWINGS SHEETS EP101 AND
ET101 FOR ADDITIONAL INFORMATION.
WALL TO BE FINISHED AND PAINTED FROM FLOOR
TO UNDERSIDE OF DECK. REFER TO FINISH
SCHEDULE ON SHEET I-601.
HANDRAIL. WALL ATTACHMENT TO NON SECURE
VESTIBULE WALL SHOWN IN DETAIL 2/AE602.
FLOOR ATTACHMENT TO SECURE VESTIBULE WALL
SHOWN IN DETAIL 11/AE602 AND 12/AE602.
07 BOUNDARY OF SECURE AREA.
08 FIRE EXTINGUISHER CABINET.
09 NOT USED
IN-SLAB FLOOR BOX WITH FIELD POWER OR
COMMUNICATION CONNECTION TO CAVITY OF
CUBICLE FURNITURE. SEE ELECTRICAL DRAWINGS
SHEETS EP101 AND ET101 FOR ADDITIONAL
INFORMATION.
12 PARTITION TYPE 1, SEE SHEET AE701.
13 PARTITION TYPE 2, SEE SHEET AE701.
IN ACCESS FLOORING FLOOR BOX WITH FIELD
POWER OR COMMUNICATIONS CONNECTION TO
CAVITY OF CUBICLE FURNITURE. REFER TO
ELECTRICAL DRAWINGS.
15 GUARDRAIL SEE DETAIL 10/AE602.
INFILL FRAMING REQUIRED FOR NEW WALL. SEE
DETAIL 3/AE302.
14 FURNITURE / EQUIPMENT CF/CI.
SECURE AREA WALL MOCKUP REQUIREMENTS
THE CONTRACTOR WILL BE REQUIRED TO CONSTRUCT A MOCK UP FOR
THE SECURE AREA WALL CONSTRUCTION FOR GOVERNMENT APPROVAL.
REFER TO WALL SECTION 3/AE302 FOR WALL ASSEMBLY INFORMATION.
THE CONTRACTOR WILL BE PERMITTED TO INCLUDE THE MOCK UP IN HIS
CONSTRUCTION, OR HE CAN CONSTRUCT A STANDALONE MOCKUP IN THE
WORK SPACE. SHOULD A STANDALONE MOCKUP BE CONSTRUCTED, IT
SHALL BE A MINIMUM OF 8-FEET WIDE AND FULL HEIGHT OF THE WALL
FROM SLAB TO UNDERSIDE OF FLOOR DECK ABOVE.
THE REQUIREMENTS FOR THE MOCKUP ARE AS FOLLOWS, AND WILL
REQUIRE GOVERNMENT APPROVAL AT EACH OF THREE JUNCTURE POINTS
STATED BELOW:
1. FOLLOWING THE REMOVAL OF THE EXISTING INTERIOR GYPSUM BOARD
LAYER AND PATCHING OF EXISTING PENETRATIONS, COLLECTIVELY
TERMED “EMPTY WALL APPROVAL”. THE CONTRACTOR SHALL PROVIDE 14
DAYS’ NOTICE TO THE GOVERNMENT FOR THIS INSPECTION AND EMPTY
WALL APPROVAL.
2. FOLLOWING EMPTY WALL APPROVAL, THE CONTRACTOR MAY PROCEED
TO INSTALL THE NON-SECURE SIDE GYPSUM BOARD LAYER,
CONSTRUCTION OF NEW METAL STUDS, INSTALLATION OF WALL
INSULATION, AND CONSTRUCTION OF EXPANDED METAL, COLLECTIVELY
TERMED “SECURE WALL FRAMEWORK APPROVAL”. THE CONTRACTOR
SHALL PROVIDE 14 DAYS’ NOTICE TO THE GOVERNMENT FOR THIS
INSPECTION AND SECURE WALL FRAMEWORK APPROVAL.
3. FOLLOWING SECURE WALL FRAMEWORK APPROVAL, THE CONTRACTOR
MAY PROCEED TO INSTALL THE FIRST LAYER OF SECURE SIDE GYPSUM
BOARD AND RF SHIELDING, COLLECTIVELY TERMED “SECURE SIDE
GYPSUM BOARD APPROVAL”. THE INSTALLATION MUST BE TAPED AND
FINISHED. THE CONTRACTOR SHALL PROVIDE 14 DAYS’ NOTICE TO THE
GOVERNMENT FOR THIS INSPECTION AND SECURE SIDE GYPSUM BOARD
APPROVAL.
FOLLOWING SECURE SIDE GYPSUM BOARD APPROVAL, THE CONTRACTOR
MAY COMPLETE THE CONSTRUCTION OF THE SECURE WALL.
IT SHOULD BE NOTED THAT THE GOVERNMENT WILL WORK WITH THE
CONTRACTOR TO EXPEDITE ALL APPROVALS.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
S L J
T F
B X
C A
E
.D
G N
AE101
T F
P A
R T
IA
L B
A S
E M
E N
T F
L O
O R
P L A
N N
E W
C O
N S
T R
U C
T
IO
N
A E
- AE101 1/4" = 1'-0"
1 PARTIAL BASEMENT FLOOR PLAN NEW CONSTRUCTION
ROOM SQ. FT. SCHEDULE
ROOM NET AREA (SQ. FT.) GROSS AREA (SQ. FT.)
VESTIBULE 91.2 106
SECURE AREA 2038.21 2130
SERVER ROOM 78.36 79
TOTAL ROOM GROSS AREA: 2315 SF
N
TRUE NORTH 20°
FROM PLAN NORTH
KEY PLAN:
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
SPRINKLER
SMOKE DETECTOR (REFER TO FA DWGS)
EXIT SIGN LOCATION (REFER TO FA DWGS)
2' x 4' DOWNLIGHT
4' PENDANT LINEAR LIGHT
SUPPLY DIFFUSER
RETURN DIFFUSER
1'-0"
CEILING HEIGHT, ABOVE EXISTING FLOOR SLAB OF 0'-0"
CEILING LEGEND:
ACT-1:
2X2 CEILING GRID
FIRE ALARM DEVICE
OS OCCUPANCY SENSOR
FLUSH MOUNTED CEILING SPEAKER (AV)
CEILING MOUNTED MICROPHONE CONNECT BOX (AV)
S
6" BATT INSULATION ABOVE CEILING
FLUSH MOUNTED MOTION DETECTORMD
SURFACE MOUNTED ELECTRICAL AND COMMUNICATIONS RACEWAY
2 3 4
C
B.3
D
3.4
B.9
2.2
B.7
VESTIBULE
EQUIP. ROOM
EXIST.
MEDICAL SVC
EXIST. ELEC
EXIST. CORR
EXIST.
MECHANICAL
EXIST.
ELECTRICAL
OS
9'-0"
9'-0"
E Q
E Q
EQ EQ
EXIST. CORR
S S
S
SS
S
SS
S EQ EQ
CL
EXPOSED
STRUCTURE
ABOVE
INSULATION
ABOVE CEILING
4'-0"
'-0
S
MD
MD
MD
MD
MD
MD
MD
MD
E Q
E Q
'-0
'-0
MD
GENERAL NOTES:
1. ALL LIGHT FIXTURES, FIRE ALARM DEVICES,
MOTION SENSORS, SPRINKLER HEADS, HVAC
SUPPLY, HVAC RETURNS, & ANY OTHER DEVICES
SHALL BE CENTERED WITHIN CEILING TILE, UNO.
2. REFER TO MECHANICAL AND ELECTRICAL DWG.S'
FOR ADDITIONAL INFORMATION.
3. REFER TO SHEET I-601 FOR INTERIOR ROOM FINISH
SCHEDULE AND FINISH KEY.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
S L J
T F
B X
C A
E
.D
G N
AE102
T F
P A
R T
IA
L B
A S
E M
E N
T R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
A E
AE102 1/4" = 1'-0"
1 PARTIAL BASEMENT REFLECTED CEILING PLAN
N
TRUE NORTH 20°
FROM PLAN NORTH
KEY PLAN:
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
EXISTING
BASEMENT
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
'-0
'-4
0'-0"
AE301
AE302
AE302
EXIST.
MEDICAL SVC
0500EXIST. CORR
0'-8"0'-4"
4'-0"
1414 14
AE602
SECURE AREA
EXISTING
BASEMENT
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
CB.3 DB.9B.7
AE301
AE301
AE602
1" / 12"
AE302
EQUIP. ROOM
EXIST. CORR
'-0
'-0
0'-8" 0'-0"
VESTIBULE
4'-0"
14 14
0'-8"
1'-0" 8'-0" 1'-0"
SECURE AREA
07 09 0913 12
AE602
AE602
EXISTING
BASEMENT
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
33.4 2.2
AE301
'-4
'-0
'-0
'-0
AE302
AE302
EXIST. CORR
EXIST.
MEDICAL SVC
0'-8" 0'-4" 0'-0"
14 14
SECURE AREA
18 07
EXISTING PERIMETER STUD WALL TO REMAIN.
NON-SECURE SIDE: THE GYPSUM BOARD LAYER
AND THE EXISTING IN-WALL INFRASTRUCTURE
FEEDING THE NON-SECURE SIDE SHALL REMAIN IN
PLACE. SECURE SIDE: THE GYPSUM BOARD ON THE
SECURE SIDE AND IN-WALL INFRASTRUCTURE
FEEDING INTO THE SECURE SIDE SHALL BE
REMOVED. REPLACE GYPSUM BOARD AND SEAL
ALL OPENINGS. REFER TO ELECTRICAL DRAWINGS.
KEYNOTE LEGEND:
INFILL FRAMING REQUIRED IN OPENINGS, SEE
DETAIL 1/AE302.
03 EXISTING STANDPIPE.
INSTALL CONDUIT AS REQUIRED AND INFILL CUT
TRENCH WITH CONCRETE TO MATCH EXISTING,
SEE ELECTRICAL DRAWINGS SHEETS EP101 AND
ET101 FOR ADDITIONAL INFORMATION.
WALL TO BE FINISHED AND PAINTED FROM FLOOR
TO UNDERSIDE OF DECK. REFER TO FINISH
SCHEDULE ON SHEET I-601.
HANDRAIL. WALL ATTACHMENT TO NON SECURE
VESTIBULE WALL SHOWN IN DETAIL 2/AE602.
FLOOR ATTACHMENT TO SECURE VESTIBULE WALL
SHOWN IN DETAIL 11/AE602 AND 12/AE602.
07 BOUNDARY OF SECURE AREA.
08 FIRE EXTINGUISHER CABINET.
09 NOT USED
IN-SLAB FLOOR BOX WITH FIELD POWER OR
COMMUNICATION CONNECTION TO CAVITY OF
CUBICLE FURNITURE. SEE ELECTRICAL DRAWINGS
SHEETS EP101 AND ET101 FOR ADDITIONAL
INFORMATION.
12 PARTITION TYPE 1, SEE SHEET AE701.
13 PARTITION TYPE 2, SEE SHEET AE701.
IN ACCESS FLOORING FLOOR BOX WITH FIELD
POWER OR COMMUNICATIONS CONNECTION TO
CAVITY OF CUBICLE FURNITURE. REFER TO
ELECTRICAL DRAWINGS.
15 GUARDRAIL SEE DETAIL 10/AE602.
INFILL FRAMING REQUIRED FOR NEW WALL. SEE
DETAIL 3/AE302.
14 FURNITURE / EQUIPMENT CF/CI.
17 6" BATT INSULATION ABOVE CEILING
20" WIDE SURFACE MOUNTED METAL RACEWAY
CONCEALING POWER AND COMMUNICATIONS
CONDUITS DROPPING FROM THE CEILING. PAINT
TO MATCH WALL.
19 NEW RAISED FLOORING ABOVE EXISTING SLAB
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
/4
/1
/ 2
:3
: 5
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE301
T F
P A
R T
IA
L B
U I L
D
IN
G S
E C
T
IO
N S
A E
AE301 1/4" = 1'-0"
2 PARTIAL BUILDING SECTION
AE101, AE301, AE401
AE301 1/4" = 1'-0"
1 PARTIAL BUILDING SECTION
AE101, AE301, AE401
AE301 1/4" = 1'-0"
3 PARTIAL BUILDING SECTION
AE101, AE301, AE401
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
D
/2
/2
'-8
9'-0"
1'-0"
EXIST. WINDOW TO REMAIN
CONT. 3/4" #9 (10 GA.) EXPANDED METAL SPOT WELD
OR APPROVED MECHANICAL FASTENING OF
HARDENED SCREWS WITH ONE INCH WASHERS OR
HARDENED CLIPS @ 6" O.C. ON 16 GA STUDS
2" ACOUSTICAL BATT INSULATION
NEW ACT CEILING
PRE-ASSEMBLE: 1 1/2" BLACK CURTAIN WALL
INSULATION GLUE/FASTEN TO 5/8" TYPE X
GYP. BD. ON 2 1/2" 16 GA. STUDS @ 12 " O.C.,
MIN 3/4" AIR SPACE BETWEEN WINDOW
GLAZING AND CURTAIN WALL INSULATION
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ
TO 60 GHZ BETWEEN 2 LAYERS TYPE X
GYP. BD. TO DECK
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ TO 60
GHZ BETWEEN 2 LAYERS TYPE X GYP. BD. TO DECK
CONT. 3/4" #9 (10 GA.) EXPANDED METAL SPOT WELD OR
APPROVED MECHANICAL FASTENING OF HARDENED
SCREWS WITH ONE INCH WASHERS OR HARDENED CLIPS
@ 6" O.C. ON 16 GA. 3 5/8" STUDS TO DECK
CONT. BEAD OF SEALANT AT TOP AND
BOTTOM OF EA. LAYER OF GYP. BD.
CONT. BEAD OF SEALANT AT TOP AND
BOTTOM OF EA. LAYER OF GYP. BD.
EXTERIOR
REMOVE EXIST. GYP BD. FROM EXTERIOR WALL.
REMOVE ALL CONDUIT/ELECTRICAL
DEVICES RE-INSTALL EXIST.
INSULATION
EXISTING 1ST FLOOR METAL FORM
DECK ON EXISTING STEEL JOIST
EXISTING STEEL BEAM
WALL TO BE FINISHED AND PAINTED FROM
TRUE FLOOR TO TRUE CEILING (DECKING).
AE601
AE601
EXTEND RF SHIELD ONTO
FLOOR AS REQUIRED BY DESIGN
EXTEND RF SHIELD ONTO DECK
AS REQUIRED BY DESIGN
3 5/8" 16 GA. STUDS AND TRACK @ 16" O.C.
WALL BASE AND FLOOR FINISH AS SCHEDULED.
SEE SHEET I-601
EXISTING
BASEMENT
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
D
REMOVE EXIST. GYP BD. FROM EXTERIOR WALL
CONT. 3/4" #9 (10 GA.) EXPANDED METAL SPOT
WELD OR APPROVED MECHANICAL FASTENING OF
HARDENED SCREWS WITH ONE INCH WASHERS OR
HARDENED CLIPS @ 6" O.C. TO EXIST. 16 GA STUDS
CONT. RF SHIELDING MIN. 35 dB, 30
MHZ TO 60 GHZ BETWEEN 2
LAYERS TYPE X GYP. BD. TO DECK
NEW ACT CEILING
O
R
ACCESS FLOORING
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ
TO 60 GHZ BETWEEN 2 LAYERS TYPE X
GYP. BD. TO DECK
CONT. 3/4" #9 (10 GA.) EXPANDED METAL SPOT WELD OR
APPROVED MECHANICAL FASTENING OF HARDENED
SCREWS WITH ONE INCH WASHERS OR HARDENED CLIPS
@ 6" O.C. ON 16 GA. 3 5/8" STUDS TO DECK
9'-0"
CONT. BEAD OF SEALANT AT
TOP AND BOTTOM OF EA.
LAYER OF GYP. BD.
CONT. BEAD OF SEALANT AT
TOP AND BOTTOM OF EA.
LAYER OF GYP. BD.
0'-4"
EXTERIOR
REMOVE ALL CONDUIT/ELECTRICAL
DEVICES RE-INSTALL EXIST.
INSULATION
WALL TO BE FINISHED AND PAINTED FROM
TRUE FLOOR TO TRUE CEILING (DECKING).
EXTEND RF SHIELD ONTO DECK
AS REQUIRED BY DESIGN
EXTEND RF SHIELD ONTO
FLOOR AS REQUIRED BY DESIGN
3 5/8" STUDS AND TRACK @16" O.C.
WALL BASE AND FLOOR FINISH AS SCHEDULED.
SEE SHEET I-601
OR 0'-8"
EXISTING
BASEMENT
0' - 0"
EXISTING 1ST
FLOOR
14' - 0"
2.2
CONT. RF SHIELDING MIN. 35 dB, 30
MHZ TO 60 GHZ BETWEEN 2 LAYERS
TYPE X GYP. BD. TO DECK
CONT. 3/4" #9 (10 GA.) EXPANDED METAL
SPOT WELD OR APPROVED MECHANICAL
FASTENING OF HARDENED SCREWS WITH
ONE INCH WASHERS OR HARDENED CLIPS
@ 6" O.C. ON 16 GA. 3 5/8" STUDS TO DECK
3" ACOUSTICAL INSULATION
BETWEEN 16 GA. STUDS
EXISTING WALL TO REMAIN SHALL HAVE
GYPSUM BOARD ON ROOM 0600 SIDE
REMOVED. REPLACE WITH NEW TYPE X GYP. BD.
EXIST. WALL
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ TO 60
GHZ BETWEEN 2 LAYERS TYPE X GYP. BD. TO DECK
CONT. 3/4" #9 (10 GA.) EXPANDED METAL SPOT WELD
OR APPROVED MECHANICAL FASTENING OF HARDENED
SCREWS WITH ONE INCH WASHERS OR HARDENED
CLIPS @ 6" O.C. ON 16 GA. 3 5/8" STUDS TO DECK
3 5/8" 16 GA. STUDS & TRACK @ 16" O.C.
NEW ACT CEILING
EXIST. CORR
9'-0"
CONT. BEAD OF SEALANT AT TOP
AND BOTTOM OF EA. LAYER OF
GYP. BD.
CONT. BEAD OF SEALANT AT
TOP AND BOTTOM OF EA.
LAYER OF GYP. BD.
EXISTING 1ST FLOOR METAL
FORM DECK
NO IN-WALL INFRASTRUCTURE
ALLOWED IN NEW SECURE WALL
PATCH & REPAIR. WALL TO
BE FINISHED AND PAINTED
FROM FLOOR TO
UNDERSIDE OF DECK.
EXISTING WALL TO HAVE
GYPSUM BOARD LAYER ON THE
NON-SECURE SIDE TO REMAIN
IN PLACE.
EXISTING WALL TO REMAIN
SHALL HAVE EXISTING
INFRASTRUCTURE FEEDING
INTO SECURE SIDE REMOVED
AND EXISTING INFRASTRUCTURE
FEEDING INTO NON-SECURE
SIDE SHALL REMAIN.
EXTEND RF SHIELD ONTO DECK
AS REQUIRED BY DESIGN
WALL BASE AND FLOOR FINISH AS
SCHEDULED. SEE SHEET I-601
EXTEND RF SHIELD ONTO FLOOR AS
REQUIRED BY DESIGN
EXISTING WALL BASE TO
REMAIN.
EXIST. ACT CEILING
SECURE AREA WALL MOCKUP
APPROVAL REQUIRED. SEE SHEET
AE101 FOR FURTHER INSTRUCTIONS
GENERAL NOTES
1. THE CONTRACTOR WILL BE REQUIRED TO
CONSTRUCT A MOCK UP FOR THE SECURE AREA
WALL CONSTRUCTION FOR GOVERNMENT APPROVAL.
REFER TO SHEET AE101 SECURE AREA WALL MOCKUP
REQUIREMENTS FOR FURTHER INFORMATION.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 0
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE302
T F
W A
L L S
E C
T
IO
N S
A E
AE302 3/4" = 1'-0"
1 WALL SECTION
AE101, AE301AE302 3/4" = 1'-0"
2 WALL SECTION
AE101
AE302 3/4" = 1'-0"
3 WALL SECTION
AE101, AE301
0" 8" 1'-4" 2'-8"
3/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
0' - 0"
C B.3D B.9 B.7
AE301
_______3
AE301
CL CL CL CL CL CL CL
4'-3" 6'-10" 6'-10" 6'-10" 9'-9" 6'-10" 6'-10"
CL
6'-10" 4'-3 1/4"
Q5
Q6Q7
90"
TYP. PT-1
RB-1
'-0
10 1/2"
6'-9 1/8" 3'-0"
'-0
10 1/8"
Q2Q2Q2Q2Q2Q2Q2Q2
PT-1
CL
'-0
CL
'-1
/4
'-0
EXISTING
BASEMENT
0' - 0"
3 3.42.2 1
AE301
CL CL
6'-2"6'-4"3'-10 1/4"
Q3
CL CL
8'-9"
RB-1
70"
5'-2 1/2"
1'-3"
'-0
PT-1 PT-2
PT-4
Q3 Q3 Q3
PT-1
CL
'-6
'-0
/4
EXISTING
BASEMENT
0' - 0"
CB.3 DB.9B.7
AE301
_______ 3
AE301
'-0
SEMI-RECESSED
F.E.C.
PT-2PT-2 PT-2 PT-2
RB-1 RB-1
EXISTING
BASEMENT
0' - 0"
33.4 2.21
AE301
CLCLCL
6'-8" 6'-2" 4'-0 1/4"
Q3
CL
1'-6" B
CL
8'-6"
6'-7 3/4"
TYP.
70"
5'-2 1/2"
1'-6 1/4"
'-0
PT-2
PT-4
RB-1
RB-1
Q3 Q3 Q3
GUARDRAIL
PT-1 PT-1
CL
'-6
'-0
/4
I-101
I-101
I-101
I-101
GENERAL NOTES
1. ALL DIMENSIONS ARE TO INTERIOR FINISH UNLESS OTHERWISE NOTED.
2. SEE DETAIL 10/AE602 FOR GUARDRAIL DETAILS
3. SEE SHEET AE601 FOR DOOR SCHEDULE.
4. SEE SHEET I-601 FOR FINISHES.
5. FOR ALL FURNITURE AND EQUIPMENT, SEE I-101.
6. COORDINATE LOCATION OF SURFACE MOUNTED ELECTRICAL AND
COMMUNICATIONS RACEWAY AND ADDITIONAL FRAMING AS REQUIRED FOR
SUPPORTING EQUIPMENT HANGING FROM CEILING & STUD WALLS.
7. SEE AUDIO VISUAL AND ELECTRICAL DRAWINGS FOR MORE
INFORMATION.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 0
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE401
T F
IN
T
E R
IO
R
E L E
V A
T I O
N S
A E
AE401 1/4" = 1'-0"
1 INTERIOR ELEVATION
AE101, 1-101
AE401 1/4" = 1'-0"
2 INTERIOR ELEVATION
AE101, 1-101
AE401 1/4" = 1'-0"
3 INTERIOR ELEVATION
AE101, 1-101
AE401 1/4" = 1'-0"
4 INTERIOR ELEVATION
AE101, 1-101
GUARDRAIL
0" 2'-0" 4'-0" 8'-0"
1/4"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
CAULK PERIMETER
OF DOOR FRAME
EACH SIDE
1 LAYER 5/8" GWB
EACH SIDE ON
3-5/8" METAL STUDS
HOLLOW METAL
FRAME
DOOR AS
SCHEDULED5 7/8"
5/8" 3 5/8" 5/8"
3" GLASS FIBER BATT
INSULATION
DOUBLE METAL STUDS
AROUND FRAME OPENING
1 LAYER 5/8" GWB EACH
SIDE ON 3-5/8" METAL STUDS
DOOR AS
SCHEDULED
HOLLOW METAL
FRAME
CAULK PERIMETER OF
DOOR FRAME EACH SIDE
DOUBLE METAL STUDS
AROUND FRAME OPENING
3" GLASS FIBER BATT
INSULATION
"F"
SINGLE SWING
DOOR
TEMPORARY
PARTITION
DOOR
HM1
R .O
R.O.
3' - 4"
FINISH
FLOOR
2"
NOTE FINISH FLOOR REFERS TO BOTH THE NEW
RAISED ACCESS FLOORING AND THE EXISTING SLAB.
SEE PLAN AE101 FOR LOCATIONS.
3 5/8" 16 GA. STUDS
& TRACK @ 16" O.C.
CONT. 3/4" #9 (10 GA.) EXPANDED
METAL SPOT WELD OR APPROVED
MECHANICAL FASTENING OF
HARDENED SCREWS WITH ONE INCH
WASHERS OR HARDENED CLIPS @ 6"
O.C. ON 16 GA. 3 5/8" STUDS TO DECK
3" ACOUSTICAL
INSULATION BETWEEN 16
GA. STUDS
CONT. RF SHIELDING MIN.
35 dB, 30 MHZ TO 60 GHZ
BETWEEN 2 LAYERS TYPE
X GYP. BD. TO DECK
REMOVE EXIST. GYP. BD. AND
REPLACE WITH NEW TYPE X
GYP. BD. ON ROOM 0600 SIDE
EXIST. STUD WALL
STC 50-SEE FINISH KEY DR-1 SHEET
I-601 FOR ADDITIONAL DOOR
FINISH INFORMATION
NEW GYP. BD. SOFFIT
5/8" 3 5/8" 5/8" 4" 3/4" 5/8"
SECURE SCIF DOOR
ASSEMBLY, STC 50
DOUBLE METAL STUDS
AROUND FRAME OPENING
3 5/8" 16 GA. STUDS
& TRACK @ 16" O.C.
CONT. 3/4" #9 (10 GA.)
EXPANDED METAL SPOT WELD
OR APPROVED MECHANICAL
FASTENING OF HARDENED
SCREWS WITH ONE INCH
WASHERS OR HARDENED CLIPS
@ 6" O.C. ON 16 GA. 3 5/8"
STUDS TO DECK
3" ACOUSTICAL INSULATION
BETWEEN 16 GA. STUDS
CONT. RF SHIELDING MIN.
35 dB, 30 MHZ TO 60 GHZ
BETWEEN 2 LAYERS TYPE
X GYP. BD. TO DECK
EXISTING STUD WALL
REMOVE EXIST. GYP. BD. AND
REPLACE WITH NEW TYPE X GYP. BD.
ON ROOM 0600 SIDE
6"
SECURE DOOR- STC 50-SEE
FINISH KEY DR-1 SHEET I-601
FOR ADDITIONAL DOOR
FINISH INFORMATION
2"
SECURE SCIF DOOR
ASSEMBLY, STC 50
DOUBLE METAL STUDS
AROUND FRAME OPENING
GENERAL NOTES:
1. SEE I-601 FOR FINISH SCHEDULE AND KEY.
EXIST. WINDOW TO REMAIN
CONT. 3/4" #9 (10 GA.) EXPANDED METAL
SPOT WELD OR APPROVED MECHANICAL
FASTENING OF HARDENED SCREWS WITH
ONE INCH WASHERS OR HARDENED CLIPS @
6" O.C. ON 16 GA. STUDS
2" ACOUSTICAL BATT INSULATION
PRE-ASSEMBLE: 1 1/2" BLACK CURTAIN WALL
INSULATION GLUE/FASTEN TO 5/8" TYPE X
GYP. BD. ON 2 1/2" 16 GA. STUDS @ 12 "
O.C., MIN 3/4" AIR SPACE BETWEEN WINDOW
GLAZING AND CURTAIN WALL INSULATION
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ TO 60 GHZ
BETWEEN 2 LAYERS TYPE X GYP. BD. TO DECK
EXIST. WALL CONSTRUCTION
NEW LAY IN CEILING AS SCHEDULED
REMOVE EXISTING GYP.
BD. RETURN, AFFIX NEW
STUDS/TRACK TO HEADER
INSPECT AND REFURBISH
EXISTING INTERIOR WINDOW
PERIMETER SEALANT PRIOR TO
INSTALLING NEW FRAMING
REMOVE EXIST. GYP BD. FROM EXTERIOR WALL
REMOVE ALL CONDUIT/ELECTRICAL
DEVICES RE-INSTALL EXIST. INSULATION
EXIST. WINDOW TO REMAIN
CONT. 3/4" #9 (10 GA.) EXPANDED METAL
SPOT WELD OR APPROVED MECHANICAL
FASTENING OF HARDENED SCREWS WITH
ONE INCH WASHERS OR HARDENED CLIPS @
6" O.C. ON 16 GA.STUDS
2" ACOUSTICAL BATT INSULATION
PRE-ASSEMBLE: 1 1/2" BLACK CURTAIN WALL
INSULATION GLUE/FASTEN TO 5/8" TYPE X
GYP. BD. ON 2 1/2" 16 GA. STUDS @ 12 " O.C.,
MIN 3/4" AIR SPACE BETWEEN WINDOW
GLAZING AND CURTAIN WALL INSULATION
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ TO 60
GHZ BETWEEN 2 LAYERS TYPE X GYP. BD. TO DECK
EXIST. WALL CONSTRUCTION
REMOVE EXIST. GYP BD. FROM EXTERIOR WALL
REMOVE ALL CONDUIT/ELECTRICAL
DEVICES RE-INSTALL EXIST. INSULATION
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 0
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE601
T F
D O
O
S
H
E D
U L E
A N
D D
E T
A
IL
S
A E
DOOR SCHEDULE AE601
MARK ROOM NAME
ROOM
NUMBER
DOOR
HARDWARE SET
FRAME
REMARKSWIDTH HEIGHT TYPE DOOR MATERIAL FINISH RATING
FRAME
TYPE MATERIAL FINISH HEAD JAMB SILL
0600 SECURE AREA 0600 3'-0" 7'-0" F WD DR-1 - HW-1 HM1 HM 5/AE601 6/AE601 - STC 45
0601 VESTIBULE 0601 3'-0" 7'-0" F SC WD DR-1 - HW-2 HM1 HM 3/AE601 4/AE601 - SECURE SCIF DOOR ASSEMBLY, STC 50
0602 EQUIP. ROOM 0602 3'-0" 7'-0" F WD DR-1 - HW-3 HM1 HM 5/AE601 6/AE601 - STC 45
AE601 3" = 1'-0"
5 HOLLOW METAL DOOR HEAD
AE601
AE601 3" = 1'-0"
6 HOLLOW METAL DOOR JAMB
AE601
1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
FRAME TYPES
AE601 3" = 1'-0"
3 HOLLOW METAL DOOR HEAD-SECURE DOOR
AE601
AE601 3" = 1'-0"
4 HOLLOW METAL DOOR JAMB-SECURE DOOR
AE601
AE601
AE601
AE601 3" = 1'-0"
7 INFILL WINDOW HEAD DETAIL
AE601 3" = 1'-0"
8 INFILL WINDOW SILL DETAIL
0" 2" 4" 0'-8"
3"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
0' - 0"
ACCESS FLOORING
1" / 12"
RAMP ASSEMBLY CPT-1
METAL HAND RAIL
A
.F .F
EDGE OF FINISH WALL
TYP.
2 1/4"
METAL WALL BRACKET
/2 M
IN
PROVIDE BLOCKING SUPPORT
B.9
2.2
3" ACOUSTICAL INSULATION
BETWEEN 16 GA. STUDS
REMOVE EXIST. GYP. BD. AND
REPLACE WITH NEW TYPE X
GYP. BD. ON ROOM 0600 SIDE
EXIST. WALL
SPOT WELD TO COLUMN
@ 6" O.C.
CONT. 3/4" #9 (10 GA.) EXPANDED
METAL SPOT WELD OR APPROVED
MECHANICAL FASTENING OF
HARDENED SCREWS WITH ONE
INCH WASHERS OR HARDENED
CLIPS @ 6" O.C. ON 16 GA. 3 5/8"
STUDS TO DECK
3 5/8" 16 GA. STUDS
& TRACK @ 16" O.C.
EXIST. CORR
REMOVE EXIST. GYP. BD. AND
REPLACE WITH NEW TYPE X GYP.
BD. ON ROOM 0600 SIDE
CONT. RF SHIELDING MIN.
35 dB, 30 MHZ TO 60 GHZ
BETWEEN 2 LAYERS TYPE
X GYP. BD. TO DECK
EXIST. WALL TO REMAIN SHALL HAVE
EXIST. INFRASTRUCTURE FEEDING
INTO SECURE SIDE REMOVED. EXIST.
INFRASTRUCTURE FEEDING INTO THE
NON-SECURE SIDE SHALL REMAIN.
D
REMOVE ALL
CONDUIT/ELECTRICAL DEVICES
RE-INSTALL EXIST. INSULATION
CONT. 3/4" #9 (10 GA.) EXPANDED
METAL SPOT WELD OR APPROVED
MECHANICAL FASTENING OF
HARDENED SCREWS WITH ONE INCH
WASHERS OR HARDENED CLIPS @ 6"
O.C. ON 16 GA. STUDS TO DECK
CONT. RF SHIELDING MIN. 35 dB, 30 MHZ TO 60 GHZ BETWEEN 2
LAYERS TYPE X GYP. BD. TO DECK
CONT. RF SHIELDING MIN. 35 dB, 30
MHZ TO 60 GHZ BETWEEN 2 LAYERS
TYPE X GYP. BD. TO DECK
(2) LAYERS TYPE X GYP. BD. ON
EXIST. 16 GA. STUDS
(2) LAYERS TYPE X GYP. BD. ON 16
GA. 2 1/2" STUDS
REMOVE EXIST. GYP BD. FROM
EXTERIOR WALL
C
3.4
2 1/2" STUDS
5/8" TYPE X GYP. BD.
FIRE EXTINGUISHER
CABINET
3 5/8" METAL
STUD WALL
W/ 5/8" GWB
EACH SIDE
SEMI-RECESSED
FIRE
EXTINGUISHER
CABINET
SECTION ELEVATION
10"
1' - 2"
/2
/2
'-0
C .L
H
A N
D L E
EXISTING
BASEMENT
0' - 0"
ACCESS FLOORING
3 5/8" STUD @ 16"O.C.
5/8" TYPE X GYP .
BD. EA. SIDE.
RB-1
ACCESS FLOOR PERIMETER
ASSEMBLY TYP
CPT-1
CPT-1
VESTIBULE
3" GLASS FIBER BATT
INSULATION
EXISTING
BASEMENT
0' - 0"
3.4
ACCESS FLOORING
3 5/8" STUD @ 16"O.C.
5/8" TYPE X GYP
. BD. EA. SIDE.
EQUIP. ROOM
ACCESS FLOOR
PERIMETER ASSEMBLY TYP
CPT-1
VCT-1
RB-1
RB-1
SECURE AREA
3" GLASS FIBER BATT
INSULATION
'-1
4'-2 1/2"
'-6
'-6
1'-7 1/2"
1 1/2".
"8
'-1
'-1
'-1
'-7
1 1/2" DIA. METAL
GUARDRAIL
EQUIP. ROOM
SECURE AREA
SECURE AREA
CORNER
POST
ACCESS FLOOR
PERIMETER
ASSEMBLY
ACCESS FLOOR
ASSEMBLY
AE602
EXISTING
BASEMENT
0' - 0"
CPT-1
ACCESS FLOOR
PERIMETER ASSEMBLY
CPT-1
TR-1
TERMINATION METAL
PLATE PER DESIGN
/4
1 3/4"
1/4" 1 /4
FLOOR FLANGE BASE ASSEMBLY
COVER FLANGE
1 1/2" DIA. METAL POST
FLOOR FINISH AS SCHEDULED
ACCESS FLOOR ASSEMBLY
FLOOR FLANGE BASE ASSEMBLY
COVER FLANGE
1 1/2" DIA. METAL POST
FLOOR FINISH AS SCHEDULED
CONCRETE FLOOR SLAB
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 0
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE602
T F
D E
T A
IL
S
A N
D S
E C
T
IO
N S
A E
AE602 1 1/2" = 1'-0"
1 RAMP DETAIL
AE301, I-102
0" 2" 4" 0'-8"
3"=1'-0"
AE602 3" = 1'-0"
2 HANDRAIL DETAIL
AE301
AE602 1 1/2" = 1'-0"
5 PLAN DETAIL
AE101
AE602 1 1/2" = 1'-0"
6 PLAN DETAIL
AE101
AE602 1 1/2" = 1'-0"
7 PLAN DETAIL
AE101
AE602 1 1/2" = 1'-0"
4 SEMI-RECRESSED FIRE EXT. CABINET DETAIL
AE101
0" 4" 8" 1'-4"
1 1/2"=1-0"
AE602 1 1/2" = 1'-0"
8 ACCESS FLOOR DETAIL
I-102
AE602 1 1/2" = 1'-0"
9 ACCESS FLOOR DETAIL
I-102
0" 8" 1'-4" 2'-8"
3/4"=1'-0"
AE602 3/4" = 1'-0"
10 ACCESS FLOOR GUARDRAIL ELEVATIONS
AE602 3" = 1'-0"
3 ACCESS FLOOR DETAIL
AE301, I-102
AE602 3" = 1'-0"
11 GUARDRAIL DETAIL
AE602 3" = 1'-0"
12 GUARDRAIL DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
PLAN
NOT RATED
V401
FIRE RATING:
DESCRIPTION:
REMARKS:
UL DESIGN:
STC RATING: STC 45
FINISH FLOOR AS
SCHEDULED
BASE AS
SCHEDULED
PARTITION TYPE DETAIL
1"=1'-0"
SECTION
3-5/8" 25 GA THICK METAL STUDS @ 16" O.C.
WITH 1 LAYER 5/8" GYP BD EACH SIDE WITH 3"
GLASS FIBER BATT INSULATION
WALL FINISHES
AS SCHEDULED
CEILING FINISHES
AS SCHEDULED
UNDERSIDE DECK,
SLAB OR BEAM
ABOVE
3-5/8" 25 GA .METAL
STUDS @ 16" O.C.
1 LAYER 5/8" GYP BD
TYPE X EACH SIDE
3" GLASS FIBER
BATT INSULATION
FIRE SEALANT
TOP/ BOTTOM
AND BOTH SIDES
WALL FINISHES AS SCHEDULED
PLAN
NOT RATED
V401
FIRE RATING:
DESCRIPTION:
REMARKS:
UL DESIGN:
STC RATING: STC 45
FINISH FLOOR AS
SCHEDULED
BASE AS
SCHEDULED
PARTITION TYPE DETAIL
1"=1'-0"
SECTION
3-5/8" 25 GA THICK METAL STUDS @ 16" O.C.
WITH 1 LAYER 5/8" GYP BD EACH SIDE WITH 3"
GLASS FIBER BATT INSULATION
WALL FINISHES
AS SCHEDULED
CEILING FINISHES
AS SCHEDULED
UNDERSIDE DECK,
SLAB OR BEAM
ABOVE
3-5/8" 25 GA .METAL
STUDS @ 16" O.C.
1 LAYER 5/8" GYP BD
EACH SIDE
3" GLASS FIBER
BATT INSULATION
FIRE SEALANT
TOP/ BOTTOM
AND BOTH SIDES
WALL FINISHES AS SCHEDULED
BRACE @ 48" O.C. TO
UNDERSIDE OF STRUCTURE
ABOVE (ALTERNATIVE)
GENERAL NOTES
1. INDICATES PARTITION TYPES LOCATED ON
FLOOR PLANS.
2. REFER TO SHEET I-103 AND I-601 FOR
PARTITION FINISH INFORMATION.
3. PROVIDE BRACING ABOVE CEILING FOR METAL
STUDS THAT EXCEEDS LIMITING HEIGHT
FACTOR PER USG TABLES.
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
A s i n d ic a te d
/1
/ 2
:3
: 1
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
D L T
T F
B X
C A
E
.D
G N
AE701
T F
P A
R T
IT
IO
N T
Y P
E S
A E
0" 6" 12" 2'-0"
1"=1'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S I G
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
U S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S W
IL
M
IN
G
T O
N D
IS
T
R
IC
T
C K
D B
Y
US ARMY CORPS
OF ENGINEERS
WILMINGTON
A N
S I D
D
C
B
A
F
IL
E N
U M
B E
R
P L O
T S
C A
L E
P L O
T D
A T
E
SHEET OF
B U
IL
D
IN
G
H
S
A R
R E
N O
V A
T
IO
N F
O R
T B
R A
G G
N
O R
T H
C A
R O
L
IN
A
J
O N
E S
F R
A N
K L
IN
R D
S
U
IT
E
R A
L E
IG
H
N
C
-3
(9
-6
P
H O
N E
(9
-8
F
A X
L
IC
E N
S E
F
-0
05/22/2017
/1
/ 2
:3
: 0
P
M
M
A Y
-6
-0
W P
M -1
-R
-0
C A
S L J
T F
B X
C A
E
.D
G N
AE901
T F
P E
R S
P E
C T
IV
E
S
A E
AE901
1 PERSPECTIVE FRONT VIEW
NTS
AE901
2 PERSPECTIVE BACK VIEW
NTS
FOR INFORMATION ONLY
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
C
B.3
D
3.4
B.9
2.2
B.7
EXIST.
MEDICAL SVC
EXIST.
MECHANICAL
EXIST.
ELECTRICAL
0'-0"
0'-0"
0'-0"
0'-0"
0'-8"
EQUIP. ROOM
3'-3" ø 5'-0 ø 5'-0 ø 5'-0
8'-0" 8'-0" 14'-1 5/8"
0'-4" 0'-8" ø 5'-0
0'-8"
VESTIBULE
3 5/8"3"
3'-2 1/2"
39'-3"
0'-4"
AE401 3
4T1
T1
T1
T1
T1
T1
T1
T1
T1
CH2
T1
T1 T1
T1
CH3
T1 T1
T1 T1
CH2
CH2
T1
T1
T1
CH1
CH2CH2CH2CH2
T1
T1
Q1
Q1
Q4
Q3
T1
T1
T1 T1
CH1
CH1
CH1
CH1
CH1
CH1
CH1
CH2CH2CH2CH2
CH2CH2CH2
CH3
CH3
CH3
CH3
CH3
CH3
CH3CH3
CH3
CH3
CH3
CH3
CH3
CH3
CH3
CH3
CH3
CH1
CH1
4'-2" 3'-10"
+/- 9'-7" +/- 3'-10 1/2" +/- 3'-8 1/2"
+/- 10'-0 1/2" +/- 4'-1" +/- 3'-10"
Q3
X1
D
B
RAMP RAMP
DN.
R A
M P
EXIST. ELEC
EXIST. CORR
EXIST. CORR
Q3 Q3 Q3
Q3 Q3 Q3
Q5
Q6
Q2
Q2
Q2
Q2
Q2
Q2
Q2
Q2
Q7
TYP.
1" / 12"1" / 12"
T3
T2
SECURE AREA
NOTE 2
NOTE 2
C
A
A ø 5'-0
1" / 12"1" / 12" 1" / 12"
A
NOTE: MOUNT ON LATCH
SIDE OF DOOR OR ADJACENT
WALL. COORDINATE WITH
SIGNAGE LOCATION PLAN
6"
B
NOTE: MOUNT ON CENTER
OF DOOR. COORDINATE
WITH SIGNAGE LOCATION
PLAN
EQ EQ
SIGNAGE - GENERAL NOTES
1. MATCH ALL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .