C001 PROJECT DESCRIPTION
The St. Louis District (MVS) of the U.S. Army Corps of Engineers (USACE) has issued this solicitation to acquire and have installed a complete Internal Communications (IC) and Public Address (PA) system on the Dredge POTTER.
C002 VESSEL DESCRIPTION
The Dredge POTTER is an inland river dustpan dredge, homeport in St. Louis, MO. The principal characteristics are:
Length ............................................................................................. 236’- 0" Beam ................................................................................................... 46'- 0" Depth (@ Side) ..................................................................................... 9’-0” Number of Decks Accommodations ............................................................................. 53 Crew Tonnage (46 CFR 69 Subpart B – Convention)............................1601 GRT
C003 SCHEDULE
The Dredge POTTER will be available to the Contractor for installation of the IC and PA systems on the date the contract is awarded. In order to maintain the dredge’s operational schedule, all installation work and testing shall be completed by 15 June 2016.
C004 LOCATION OF WORK
The Dredge POTTER will have dockside availability at:
U.S. Army Corps of Engineers
U.S. Army Engineer District, St Louis Dredge POTTER Foot of Arsenal St
St Louis, MO 63118
All installation work shall be performed by the Contractor at this facility.
The local points of contact are:
Jared Schmidt – 314-378-0485 John Miller – 314-724-7045
C005 APPLICABLE REGULATORY STANDARDS
The IC and PA systems shall be designed and installed in accordance with the following regulatory requirements:
• 46 CFR Subchapter J – Electrical Engineering o 46 CFR 113.30 – Internal Communications o 46 CFR 113.50 – Public Address Systems
• 46 CFR Subchapter W o 46 CFR 184.602 – Internal Communications o 46 CFR 184.610 – Public Address Systems o 46 CFR 195.05 – Electrical Engineering and Interior Communications
Systems
• American Bureau of Shipping (ABS) “Rules for Building and Classing Steel
Vessels for Service on Rivers and Intracoastal Waterways”.
o Note – ABS review is not require for this system and/or installation
C006 SCOPE OF WORK
A. CONTRACT DRAWING
579-B765-01 INTERNAL COMMUNICATIONS & PUBLIC ADDRESS
SYSTEM
B. REFERENCE DRAWINGS
579-G205-01 OUTBOARD PROFILE
579-G215-01 GENERAL ARRANGEMENTS – HOLD, MAIN DECK,
UPPER DECK & TEXAS DECK
579-G233-01 GENERAL ARRANGEMENTS – PILOT HOUSE DECK
C. SYSTEM DESCRIPTION
A complete integrated communications system, including internal communications (IC) two-way calling and public address (PA) system, shall be provided and installed by the Contractor as shown on the Contract Drawings. The system shall be installed complete with network controllers, amplifiers (if necessary), back-up/reserve battery power sources, desk or wall mounted phones, PA speakers and horns, indicator lights and buzzers, noise cancelling headsets and PA microphones.
The integrated communications system shall be an IP (Internal Protocol), ethernet network-based system with pluggable endpoints. The system shall be software configurable, upgradable and expandable. The systems shall consist of network controllers, distribution nodes (if necessary) and the pluggable endpoints (speakers, phones, microphones, etc.).
The system shall allow for dial-telephone internal communications between any two stations as shown on the Contract Drawings.
The system shall also provide PA capability and speakers at the stations shown on the Contract Drawings. A PA microphone/station shall be provided in the pilothouse and main deck control room. In addition, any dial-telephone station shall be able to “call” the PA to make an announcement.
The systems shall be designed and installed so that the loss of one component of the system does not disable the rest of the system.
The PA system shall be integrated with the ship’s General Alarm system. When the General Alarm is activated, the use of the PA shall temporarily interrupt the General Alarm bells/signals to make announcements and provide instructions.
D. SYSTEM NETWORK CONTROLLERS
The Contractor shall provide and install all of the necessary network controllers and support hardware (lineboards, amplifiers, etc.) for the complete and functioning IC and PA systems. The equipment shall be installed in Electronics Room located on the Texas Deck.
The Electronics Room on the vessel has seven (7) TS8 33U Electronics Rack
Cabinets, each 24”Wx24”Dx79”H. The cabinets support standard 19” racks. One 33U cabinet (No. 4), with 28 available units of cabinet space will be made available to the Contractor. The Contractor shall install all rack units in the existing No. 4 rack onboard the vessel.
The Contractor shall ensure the system and equipment provide can be installed in the limited space available.
The enclosures shall be rugged and suitable for the inland marine environment.
E. SYSTEM ELECTRICAL REQUIREMENTS
The IC and PA systems shall have a main and back-up power supply. The vessel is equipped with AC and DC electrical systems. An AC or DC electrical power supply feed (e.g. spare electrical panel breaker) will be available for the systems with connections in the Electronics Room. The Contractor shall be required to provide and install all electrical components and materials to tie into the vessel’s electrical and general alarm systems.
The IC and PA systems shall be provided with a back-up/reserve power supply that is independent of the vessel’s electrical system. In the event of the loss of primary power supply, the systems shall automatically switch to the back-up power supply. The back-up power supply shall be sized to support the systems for 18 hours (per 46 CFR 112.05).
The systems shall give an alarm or notification when the back-up/reserve power supply is low or requires replacement.
F. CABLES & CABLE PULLS
The Contractor shall provide and install all cabling necessary for the complete and functioning IC and PA systems. All cables, unless impractical , shall be installed in established wireways and conduits. In compartments and spaces with finish joinery and ceilings, the cable shall be installed behind the finish work.
The vessel has a vertical wireway trunk located between Frames 85-86, running from the Main Deck to the Pilothouse. The Contractor shall utilize this trunk to pull cable between decks.
All cables from the electronics room controllers to the endpoints shall be CAT 5 or CAT 6 type.
The Contractor shall provide and install the IC phone wall jacks and plastic cover plates. The cover plates shall be the industry standard size (2¾”x4½”). The COR shall identify the final color selection during installation.
The Contractor shall restore watertight deck and bulkhead penetrations as required. Any joinery panel, ceiling panel/tile or sheathing that was disrupted during installation shall be restored/reinstalled to their prior condition.
G. PA SPEAKERS, BEACONS & MICROPHONE
Public Address speakers shall be installed on all spaces identified in the Contract Drawings. In compartments and rooms with finish joinery and ceilings, the speakers shall be flushed mounted in the ceiling. The external speakers and internal speakers in non-joinery spaces, shall be made of corrosion free material and installed with a stainless steel bracket.
For large internal areas and spaces, the Contractor shall provide a sufficient number for speakers to ensure all announcements can be heard and understood.
In areas identified as high noise on the contract drawings, the Contractor shall provide and install visual signal beacons. The color shall be yellow. The beacon shall activate when the PA system is in use.
The Contractor shall provide and install a PA microphone with a fifteen foot cord in the pilothouse. The push bottom microphone shall be located on the navigation console. The final location will be identified by the COR during installation. A retaining clip shall be provided for the microphone.
The Contractor shall provide and install a push button PA microphone in the main deck control room console. The final location will be identified by the COR during installation.
H. IC TELEPHONES, HEADSETS & BEACONS
The Contractor shall provide and install telephones, headsets and beacons in accordance with the Contract Drawings for a complete IC system. For non-high noise spaces, the IC telephone shall be capable of being bulkhead mounted or installed on a desk. During installation, the COR will identify the method of phone attachment for each location.
In high noise areas, the contractor shall provide and install noise canceling headsets. The headsets shall have any adjustable mouthpiece speaker, with a hand-held push button activation. Thirty feet of cord shall be provided for each headset.
In high noise areas, the Contractor shall provide and install visual signal beacons.
The color shall be yellow. The beacon shall activate at the respective station when a call is being received. In addition, the PA speaker in the high noise space shall emitted an audible signal when a call is being received.
I. IC DIRECTORY PLATES AND STATION NUMBERS
The numbers for each station being served by the IC system shall be designed and arranged logically with respect to the arrangements. All IC stations on respective decks shall start with the same number. The following numbers shall be sequential in order, starting at the forward station and working aft. Stations on the starboard side shall be odd numbered, and stations on the port side shall be even numbered. The pilothouse shall be odd numbered. The two stations in the upper part of the dredge pump room shall be served by the same extension, and be odd numbered.
The PA dial number shall be an easily recognized number.
The Contractor shall provide and install engraved plastic directory plates at every
IC station. The directory shall include numbers to all stations and the PA dial call feature number. The directories shall be either bulkhead mounted or secured to a desk with damage free, adhesive mounting, similar to 3M Command products. The COR shall identify the mounting method during installation.
C008 TESTING
After the systems have been installed, the Contractor shall perform testing to verify system installation and function. A Government representative shall witness the testing.
All system tests shall be performed with primary electrical power and under back-up/reserve power
At a minimum, the following shall be tested or verified:
• Verify all watertight bulkhead and deck penetrations impacted by the installation are restored.
• Verify all joinery panels, ceiling panels/tiles and sheathing impacted by the installation are restored to their prior condition.
• For the IC system tests, the Contractor shall:
o verify the control cabinet/switchboard is installed with primary and back-up electrical power o verify telephones or headsets are provided at each station as required o verify signal beacons are installed as required o verify directory plates are accurate and installed as required o demonstrate the complete operation of the system at each station, verify calling to all other stations (dial phone and headsets) where applicable, verify signal beacons and PA speaker buzzers are activated
• For the PA system tests, the Contractor shall:
o verify the control cabinet/switchboard is installed with primary and back-up electrical power in the electronics room o verify all PA speakers are installed as required where applicable, verify volume control feature is provided where applicable, verify material of speaker and mounting bracket verify signal beacons are installed as required o demonstrate the complete operation of the system confirm the PA microphone in the pilothouse functional confirm the PA microphone in the control room is functional from each IC station, confirm the PA dial call feature is functional verify the function of each PA speaker verify/adjust the volume of each speaker, where applicable verify the high-noise area signal beacons
The Contractor shall prepare a test procedure. The test procedure shall be submitted to the COR for review at least 10 days prior to the scheduled testing.
Following testing, the Contractor shall complete IC & PA System Test Report and submit it to the COR.
C009 FINAL DELIVERABLES
The Contractor shall provide two complete operator and equipment manuals for the IC and PA systems. The manual(s) shall be bound or placed in a heavy-duty 3-ring binder. Two electronic copies of the manuals shall be provided on a CD/DVD.
The Contractor shall provide As-Built logic and block wiring diagrams of installed IC and PA systems.
C010 WARRANTY AND SUPPORT
The Contractor shall warranty all equipment and installation for a period of 12 months after final acceptance.
The Contractor shall provide service support and software upgrades for 3 years following final acceptance. The service point of contact(s) shall be listed in the operator manual.
The Contractor shall update the Contract Drawing 576-A765-01 to reflect the As- Built systems. The drawing shall be renumbered to 576-G765-01. In addition to updating the drawing, the Contractor shall add a sheet to include complete bill of materials and equipment lists, with manufacturer’s make and model numbers.
C010 WARRANTY
The Contractor shall provide a full warranty on the complete systems installation and equipment for a period of two year. The warranty shall start when the testing is successfully completed. For warranty work, the Contractor shall be responsible for all costs.