U. S. ARMY ENGINEER DISTRICT, CHICAGO
231 SOUTH LASALLE STREET SUITE 1500
CHICAGO IL 60604-1437
W81G6681912023
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
REFERENCE: SOLICITATION W912P6-19-Q-0005; IMMIGRATION AND CUSTOMS ENFORCEMENT (ICE) BROADVIEW SECURITY FEATURES
- This Amendment makes the changes as delineated on the follow ing pages.
- The quotation due date and time remains the same. All quotes are due on April 9, 2019, NO LATER THAN 4:30PM CDT.
- Point of Contact for this Amendment is Anita R. Simpkins at (312) 846-5370 or anita.r.simpkins@usace.army.mil.
1. CONTRACT ID CODE PAGE OF PAGES
1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 03-Apr-2019
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912P619Q0005
X 9B. DATED (SEE ITEM 11)
14-Mar-2019
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
03-Apr-2019
CODE
U.S. ARMY ENGINEER DISTRICT, CHICAGO
231 SOUTH LASALLE STREET SUITE 1500
CHICAGO IL 60604-1437
W912P6 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W912P6
FACILITY CODECODE
anita.r.simpkins@usace.army.milEMAIL:312.846.5370TEL:
ANITA R SIMPKINS / ADDED BY UPASS
W912P619Q0005
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
The following items are applicable to this modification:
SUMMARY OF CHANGES
A. Amended Specifications: The Bidder shall remove and replace the respective Sections with the Revised Sections attached hereto.
SECTION NUMBER AND TITLE
PARAGRAPH AND DESCRIPTION OF
CHANGE
01 11 00 Scope of Work
Changes were made throughout the entire section.
Additional doors were added, overhead track for gate was changed to ground track, and telescoping mast won’t be needed anymore.
B. USACE’S RESPONSES TO CONTRACTOR’S INQUIRES FOLLOW:
Question #1: Can we have a copy of the sign-in sheet sent to us from the pre-bid meeting?
USACE RESPONSE TO QUESTION #1: The attendance sheet from the Project Meeting and Site-Visit, which was held on March 21, 2019 was provided under Amendment 0001 of this Solicitation.
Question #2: Does the cabling for the systems have to be in conduit or is it just laid above the ceiling to each device?
USACE RESPONSE TO QUESTION #2: Cabling may be bundled and laid above the ceiling. Labeling is required on all cables. 01 11 10 Specification Section, paragraph 3.1.2 is revised by way of this Amendment 0002 to provide this information.
Question #3: The tower outside notes to have an extendable camera added to it for security at a parking lot across the way; it is needed to be at 75' above the ground. The existing tower seems to be between 80' and 100' already; do we need the extension system? Or do we need to mount the new camera on the existing tower with the 360 degree panning equipment. Please verify if the tower height is adequate for the facility's needs or not.
USACE RESPONSE TO QUESTION #3: The existing radio tower is high enough, telescopic mast does not need to be provided under this contract. Mounting bracket will need to be attached to the radio tower in order to mount specified camera. The requirement to be able to view area on the other side of the building will remain in the Scope of Work. This Amendment changes Specification Section 01 11 10, paragraph 3.8.
Question #4: For the new door hardware items; there isn't a specification or an equalization product description. What do we need to meet or match for the new hardware requirements?
USACE RESPONSE TO QUESTION #4: Specification Section 01 11 00, paragraph 3.1.9 is revised by way of this Amendment to provide more details.
Question #5: For the dog run and the entry gate for the parking lot; can you tell us who installed the original system or who does any maintenance for these items?
USACE RESPONSE TO QUESTION #5: First Fence, Hillside IL (Ken Kolar) 630-743-8006 installed some of the perimeter fencing at Broadview. They have also provided repairs for the existing fence and privacy screening.
Question #6: Item 3.3.2 CCTV Details section calls out a 4 channel color duplex multiplexer quad video processor; what is this required to work with or replace?
USACE RESPONSE TO QUESTION #6: See revised Specification Section 01 11 00, paragraph 3.3, attached to this Amendment.
Question #7: During the prebid meeting it was brought up that the existing cameras didn't need any adjustments per the security personnel; did you want to provide us with an allowance of time that we should allow for this potential work item?
USACE RESPONSE TO QUESTION #7: Paragraph 3.3.2 of Specification Section is revised by way of this Amendment to allow 1-hour to adjust camera and pre-set view (for each camera).
Question #8: The new drive-in gate for the G2 parking lot has a Com-Ed service line to the building from their pole which could interfere with providing an overhead track system. Can you provide an allowance for all of to include in our bid for Com-Ed to relocate/raise the existing service to the building (they won't give an estimate for this work until engineering completes their required scope of work for them to put a price against). We would need an allowance that you will require all of the bidders to carry for this work.
USACE RESPONSE TO QUESTION #8: The gate type is changed to ground track or cantilever type.
Specification Section 01 11 10, paragraph 3.5 has been revised in accordance, with this Amendment.
The overhead track is no longer required, therefore, there is no need to coordinate with ComEd.
Question #9: Also with this gate, what would be the required clearance for the overhead rail system, including the peak height (since this is a raised access drive to get into the parking lot we need to know the worse-case scenario for this height)?
USACE RESPONSE TO QUESTION #9: The gate should accommodate semi-truck 14 feet high. This requirement has been added to Specification Section 01 11 10 paragraph 3.5. Instead of overhead rail system, the Specification has been changed to cantilever sliding gate with ground track.
Question #10. Do we know if the existing cabling/power is available at each of the three gate locations for the card-readers and gate operation needs; or would we have to run new lines out to each of these gate locations; please clarify. Also if we need to run new feeds out to each gate, can we assume that the conduits can be reused for each location?
USACE RESPONSE TO QUESTION #10: There is existing power for G2 vehicle gate and fence mounted CR at location. Per the specification, you are required to pull power for pedestrian gate CRs and magnetic lock system. The power to G3 Sally Port pole mounted CR is currently in place. The dog run gate requires panic bar on interior and cylinder lock with an integrated pull handle on the street (exterior) side. No additional power needed at this exit point. See the revised Specification Section 01 11 00 paragraph 3.4 for more details.
Question #11: Will this project be completed during normal working hours or after-hours? If after-hours are required, can we assume that the facility will provide and pay for the security requirements?
USACE RESPONSE TO QUESTION #11: This project will be completed during normal working hours, as listed in the Specification Section 01 10 00, paragraph 1.3.
Question #12: Will the tower extension portion of the bid be removed since extending the tower will not be necessary for viewing the leased parking lot?
USACE RESPONSE TO QUESTION #12: See revised Specification Section 01 11 00, there is no need for telescoping mast.
Question #13: Part E: This section asks for pricing to include work that will be done by ComEd. ComEd will not provide pricing to a sub contractor for this. It needs to be direct with the customer. Will this request be removed from the bid?
USACE RESPONSE TO QUESTION #13: See revised Specification Section 01 11 00 paragraph 3.8, coordination with ComEd is no longer necessary, since the gate is now required to will have ground track instead of overhead.
I CE Br oadvi ew Secur i t y Feat ur es W912P619Q0005
SECTI ON TABLE OF CONTENTS
DI VI SI ON 01 - GENERAL REQUI REMENTS
SECTI ON 01 11 00
SUMMARY OF WORK
08/15
PART 1 GENERAL
1. 1 GENERAL
1. 2 SUBMI TTALS
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON
3. 1 PART A - ACCESS SYSTEM
3. 1. 1 Physi cal Access Cont r ol ( PACS)
3. 1. 2 I nf r ast r uct ur e
3. 1. 3 Physi cal Access Cont r ol Syst em ( PACS) Pr ogr ammi ng
3. 1. 4 Car d Reader s Types
3. 1. 5 Car d Reader Spacer s
3. 1. 6 Out door Car d Reader
3. 1. 7 Car d Reader I nst al l at i on
3. 1. 8 Locks
3. 1. 9 Ot her Door Har dwar e
3. 1. 10 Connect i v i t y Handshake
3. 1. 11 Vi deo Phones
3. 1. 12 Devi ce Label i ng
3. 1. 13 Locat i on of PACS
3. 2 PART B - LI FE SAFETY DOOR UPGRADES
3. 3 PART C - EXI STI NG CLOSED CI RCUI T TELEVI SI ON ( CCTV) CAMERAS
3. 3. 1 Task Descr i pt i ons
3. 3. 2 CCTV Det ai l s
3. 3. 3 Vi deo Cover age Ar eas
3. 3. 4 Vi deo Moni t or Locat i ons
3. 4 PART D - EXI STI NG I NTERCOM SYSTEM
3. 5 PART E - G2 PERI METER SECURI TY PROJECT
3. 6 PART F - USER TRAI NI NG FOR OPERATI ON AND MAI NTENANCE ( O&M)
3. 7 PART G - ESS WARRANTY PLAN
3. 8 PART H - RADI O TOWER EXTENSI ON
3. 9 PART I - ATTACHMENTS
- - End of Sect i on Tabl e of Cont ent s - -
SECTI ON 01 11 00 Page 1
AMD #0002 - 03/ 28/ 19
SECTI ON 01 11 00
SUMMARY OF WORK
08/15
PART 1 GENERAL
1. 1 GENERAL
The cont r act or shal l pr ovi de al l necessar y equi pment , per sonnel , and mat er i al s t o per f or m al l wor k def i ned i n t hi s Summar y of Wor k ( SOW) Sect i on. The Cont r act or shal l r ef er ence si t e dr awi ngs and I mmi gr at i on and Cust oms Enf or cement ( I CE) per sonnel f or al l equi pment i nf or mat i on and l ocat i ons. Faci l i t y dr awi ngs of t he f i r st f l oor and t he G2 par ki ng l ot and " Dog Run" ar e pr ovi ded i n At t achment 1 of PART I t o t hi s SOW and i t shoul d be used as REFERENCE ONLY. Addi t i onal f aci l i t y i nf or mat i on can be pr ovi ded upon r equest .
El ement s of The Wor k i ncl ude:
a. Access Syst em
b. Li f e Saf et y Door Upgr ades
c. Exi st i ng Cl osed Ci r cui t Tel evi s i on ( CCTV) Camer as
d. Exi st i ng I nt er com Syst em
e. G2 Per i met er Secur i t y Pr oj ect f . User Tr ai ni ng f or Oper at i on and Mai nt enance ( O&M)
g. El ect r oni c Secur i t y Syst em ( ESS) War r ant y Pl an
h. Radi o Tower Ext ensi on
The Cont r act or i s r esponsi bl e f or damage t o any equi pment , mat er i al s, sur f aces or ot her wor k di sr upt ed as r esul t of t he wor k. The Cont r act or wi l l pat ch and pai nt any hol es and make any r epai r s t o any sur f ace ( i . e. , wal l s, door s, cei l i ng, et c. ) t hat i s t he r esul t of t he Cont r act or ' s wor k.
Repai r wor k must mat ch exi st i ng const r uct i on i n gr ade and l i keness. Repai r or r emuner at i on wi l l be t he sol e r esponsi bi l i t y of t he Cont r act or . I f such wor k cannot be r epai r ed wi t hi n a r easonabl e t i me, t he Gover nment r eser ves t he r i ght t o r epai r damaged equi pment , mat er i al s or sur f aces and of f set t he cost s f or such r epai r s f r om t he awar ded cont r act pr i ce. The Cont r act or wi l l coor di nat e any ant i c i pat ed ESS downt i me wi t h t he I CE Faci l i t y Si t e Manager ( FSM) and l ocal I CE Pr ogr am Of f i ces.
Conf l i c t s bet ween manuf act ur er ' s r ecommendat i ons, speci f i cat i ons, and/ or cont r act document s must be r epor t ed i n wr i t i ng t o t he Gener al Ser vi ces Admi ni st r at i on ( GSA) or Cont r act i ng Of f i cer Repr esent at i ve f or r esol ut i on.
Al l passwor ds f or ESS component syst ems wi l l be changed f r om t he def aul t and be pr ovi ded t o l ocal management i n t he t r ai ni ng sessi on and r ecor ded i n t he c l oseout document at i on.
The Cont r act or shal l submitt submit a Pr oj ect Pl an pr i or t o st ar t i ng t he
SECTI ON 01 11 00 Page 2
Work.
The Cont r act or shal l pr ovi de suf f i c i ent over si ght by a qual i f i ed Pr oj ect Manager wi t h a mi ni mum of f i ve year s exper i ence.
1. 2 SUBMITTALS
Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;
submi t t al s not havi ng a " G" desi gnat i on ar e f or i nf or mat i on onl y. When used, a desi gnat i on f ol l owi ng t he " G" desi gnat i on i dent i f i es t he of f i ce t hat wi l l r evi ew t he submi t t al f or t he Gover nment . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL PROCEDURES:
SD- 01 Pr econst r uct i on Submi t t al s
Pr oj ect Pl an; G, DC
SD- 03 Pr oduct Dat a
Pr oduct Speci f i cat i ons; G, CN
Wr i t t en Appr oval ; G, CN
SD- 06 Test Repor t s
PI M Test i ng; G, CN
SD- 07 Cer t i f i cat es
Cer t i f i cat e Of Tr ai ni ng; G, CN
Cont r act or ' s Cer t i f i cat i on Let t er ; G, CN
SD- 08 Manuf act ur er ' s I nst r uct i ons
Manuf act ur er ' s Recommendat i ons
SD- 10 Oper at i on and Mai nt enance Dat a
Manuals ; G, DC
SD- 11 Cl oseout Submi t t al s
Cont r act or ' s War r ant y Pl an; G, DC
As- Bui l t Package; G, DC
PART 2 PRODUCTS ( NOT USED)
PART 3 EXECUTI ON
3. 1 PART A - ACCESS SYSTEM
I CE r equi r es t he Secur i t y Cont r act or t o desi gn, pr ocur e, i nst al l , conf i gur e, pr ogr am, t est , document , mai nt ai n component s and i nst al l at i on wor k t hr ough t he war r ant y per i od and t r ai n per sonnel on a t ur n- key El ect r oni c Secur i t y Syst ems ( ESS) . The ESS sub- syst ems shal l i ncl ude but
SECTI ON 01 11 00 Page 3 may not be l i mi t ed t o t he f ol l owi ng.
Physi cal Access Cont r ol Syst em ( PACS) , I nt r usi on Det ect i on Syst em ( I DS) and Vi deo Sur vei l l ance Syst em ( VSS) . Al l pr ogr ammi ng, sof t war e l oads and mai nt enance wi l l be done on- si t e. The Cont r act or wi l l not be aut hor i zed r emot e ( c l i ent ) access t o t he net wor k or syst ems t o per f or m mai nt enance, t r oubl eshoot pr obl ems, or appl y sof t war e changes.
The Cont r act or i s r equi r ed t o per f or m a f ul l t est and cr eat e a r epor t of r esul t s of t he Bur gl ar Al ar m Syst em, Access Cont r ol syst em and t he CCTV syst em af t er t he new wor k i s compl et ed. . The Cont r act or i s t o r ecei ve wr i t t en appr oval f r om t he I CE Fi el d Secur i t y Manager f or new devi ces pr i or t o pr ocur ement and i nst al l at i on. The Cont r act or may be r equi r ed t o i nst al l new wi r i ng i ncl udi ng, but not l i mi t ed t o, communi cat i on and power suppor t necessar y f or t he oper at i on of t he ESS. The Cont r act or may and i s encour aged t o pr opose ESS sol ut i ons not speci f i ed her e t hey bel i eve wi l l be benef i c i al t o I CE oper at i ons at t hi s l ocat i on.
The Cont r act or shal l pr ovi de dr awi ngs f or each ESS component sub- syst em ( PACS, I DS, VSS) and a combi ned ESS dr awi ng wi t h al l component sub- syst ems.
Dr awi ngs shal l l i s t each component i ndi v i dual l y ( i . e. , wor kst at i on( s) , panel s, encl osur es, power suppl i es, f i el ded devi ces) and t hei r i nst al l at i on l ocat i ons. The Cont r act or shal l ensur e t hat al l mount i ng det ai l s and al l devi ces ar e cr oss r ef er enced i n t he dr awi ngs i ncl udi ng al l dat a cabl i ng t hat i nt er connect component s, and al l power connect i ons.
The Cont r act or shal l ut i l i ze exi st i ng wi r i ng t o t he f ur t hest ext ent possi bl e. Wher e addi t i onal wi r i ng i s needed, t he Cont r act or shal l pr ovi de and i nst al l addi t i onal wi r i ng t o compl et e t he r equi r ement s of t hi s scope.
Any new wi r i ng must be i nst al l ed under t he di r ect super vi s i on of t he I CE Fi el d Secur i t y Manager .
Al l wor k per f or med shal l compl y wi t h Nat i onal and l ocal codes, or di nances, r egul at i ons, and ot her l egal r equi r ement s of publ i c aut hor i t i es, whi ch bear on t he per f or mance of wor k. The Cont r act or i s t o acqui r e al l necessar y per mi t s f or t he compl et i on of t hi s wor k.
Al l ESS component s pr ovi ded by t he cont r act or ar e r equi r ed t o meet appl i cabl e r egul at i ons, di r ect i ves and gui del i nes f or t hat r espect i ve activity.
When t he Cont r act or has compl et ed al l ESS wor k, t he Cont r act or i s t o t est and cer t i f y t he wor k per f or med has been compl et ed, and t he syst ems/ har dwar e pr ovi ded i s i n good wor ki ng or der . The Cont r act or ' s cer t i f i cat i on l et t er must be s i gned by a seni or company of f i c i al on l et t er head i dent i f y i ng each t ask and ESS component appl i cabl e t o t he cer t i f i cat i on. The Cont r act or must f ol l ow t he pr escr i bed channel s per t he Cont r act when submi t t i ng cer t i f i cat i ons. A f ul l y compl et ed I nput / Out put Por t Char t Number i ng For m ( appendi ces) ar e r equi r ed wi t h t he Cont r act or ' s cer t i f i cat i on l et t er .
Cont r act or ' s cer t i f i cat i on l et t er wi t hout t hese appendi ces wi l l del ay t he ESS f i nal wal k- t hr ough t est . Wi t hi n t wo weeks of r ecei pt of t he cer t i f i cat i on t he I CE Fi el d Secur i t y Manager and Cont r act or wi l l per f or m a f i nal wal k- t hr ough i nspect i on/ checkl i st and accept ance t est of t he ESS t o ensur e t he syst em i s compl et e and accept ed. I nspect i ons and t est s wi l l be conduct ed by t he I CE Fi el d Secur i t y Manager dur i ng t he f i nal wal k- t hr ough.
Dur i ng t he accept ance t est , cont r act or shal l demonst r at e al l equi pment and syst em f eat ur es t o I CE Fi el d Secur i t y Manager .
SECTI ON 01 11 00 Page 4
a. Any por t i ons of wor k f ound t o be def i c i ent or not i n compl i ance wi t h t hese r equi r ement s must be r esponded t o and/ or cor r ect ed wi t hi n 14 cal endar days. A r easonabl e t i me ext ensi on may be gr ant ed as det er mi ned by I CE Fi el d Secur i t y Manager . Upon cor r ect i on of def i c i enci es, cont r act or shal l submi t a r equest i n wr i t i ng f or anot her accept ance t est wi t h t he I CE Fi el d Secur i t y Manager .
b. I f , at t he concl usi on of t he accept ance t est , al l wor k i s f ound t o be accept abl e and i n compl i ance wi t h t he r equi r ement s, t he Gover nment wi l l i ssue a l et t er of accept ance.
Dat e of benef i c i al use and war r ant y st ar t dat e cannot commence pr i or t o a successf ul f i nal wal k- t hr ough t est . Fai l ur e of any Cont r act or pr ovi ded har dwar e or sof t war e syst em t o per f or m as speci f i ed wi l l be const r ued as a f ai l ur e t o compl y wi t h r equi r ement s of t he cont r act .
Wi t hi n 30 cal endar days of awar d, t he Cont r act or shal l pr ovi de an updat ed Pr oj ect Pl an f or t he cont r act , whi ch wi l l addr ess dat e of compl et i on f or al l har dwar e i nst al l at i on, ESS component cer t i f i cat i on submi t t al wi t h Por t Char t , Physi cal Access Cont r ol Syst em ( PACS) Checkl i st and f i nal wal k- t hr ough t est .
3. 1. 1 Physi cal Access Cont r ol ( PACS)
Thi s I CE l ocat i on wi l l be est abl i shed as a c l i ent t o t he I CE E- PACS; no ot her PACS syst ems may be subst i t ut ed f or t hi s pr oj ect . I CE has pr ocur ed Sof t war e House C• CURE 9000 Ent er pr i se Physi cal Access Cont r ol Syst ems ( E- PACS) t o i mpl ement HSPD- 12 wi t hi n t he Agency. The PACS har dwar e, syst em ar chi t ect ur e and par amet er s descr i bed i n t hi s PACS t ask have been appr oved by t he FI PS 201 Eval uat i on Pr ogr am and meet t he di r ect i ves, r egul at i ons and st andar ds r ef er enced wi t hi n t hi s document . No devi at i on f r om t he pr oduct s speci f i ed and/ or descr i bed, or f r om t he i nst al l at i on met hods i dent i f i ed i s allowed.
Har dwar e Compat i bi l i t y . The Cont r act or i s r esponsi bl e f or ensur i ng t he har dwar e pr ovi ded i s compat i bl e wi t h t he I CE Ent er pr i se Sof t war e House C• CURE 9000 PACS and capabl e of managi ng cur r ent I CE PI V car ds.
Compat i bi l i t y i s def i ned as t he i nt egr at i on of a non- st andar d devi ce i nt o a conf i gur at i on and t o f ul l y oper at e l i ke a s i mi l ar devi ce as pr escr i bed by t he syst em manuf act ur er . Thi s woul d i ncl ude al l har dwar e, f i r mwar e and sof t war e capabi l i t i es of t he non- st andar d devi ce.
Juni per . A cont r act or - pr ovi ded Juni per devi ce i s needed t o connect t o t he I CE i nt r anet . A cont r act or - pr ovi ded Ci sco Syst ems or Li nksys unmanaged swi t ch( es) may al so be necessar y i f mor e t han f our PACS panel s ar e t o be connected.
The onl y accept abl e Juni per devi ce f or t hi s pr oj ect i s Juni per Net wor ks SRX320 Ser vi ces Gat eway ( non- POE) or appr oved equal .
The Cont r act or i s r esponsi bl e f or al l cost s t o shi p t he Juni per devi ce t o I CE HQ f or pr ogr ammi ng and back t o t he pr oj ect s i t e. The Cont r act or shal l ensur e a shi ppi ng l abel wi t h a compl et e r et ur n addr ess t o t he pr oj ect s i t e i s pr ovi ded. The I CE HQ shi ppi ng addr ess i s:
U. S. I mmi gr at i on and Cust oms Enf or cement ATTN: Physi cal Secur i t y Oper at i ons Uni t ( PACS Team) 950 L' Enf ant Pl aza SW Mai l St op: 5501
SECTI ON 01 11 00 Page 5
Washi ngt on D. C. 20536 Of f i ce: ( 202) 732- 8352
The Cont r act or i s r esponsi bl e f or connect i ng each PACS panel t o t he Juni per devi ce f or communi cat i ons over t he ent er pr i se net wor k.
The onl y accept abl e PACS panel s f or t hi s pr oj ect ar e t he f ol l owi ng Tyco Sof t war e House pr oduct s:
a. i STAR Ul t r a ( not SE model ) or appr oved equal and
b. i STAR Edge ( not SE model ) or appr oved equal .
The oper at i ng vol t age, as set f r om t he PACS panel s, of al l car d r eader s shal l be changed f r om t he f act or y def aul t of 5 Vdc t o 12 Vdc t o avoi d per f or mance i ssues. The Cont r act or shal l i nst al l new pl enum- r at ed cabl e bet ween t he new PACS panel encl osur es and car d r eader s.
The Cont r act or wi l l pr ovi de compl et ed PACS Por t Char t s wi t h as- bui l t dr awi ngs showi ng t he l ocat i on of each car d r eader i n or der t o compl et e pr ogr ammi ng. The cur r ent ver si on of t he Por t Char t s f or m wi l l be pr ovi ded by t he I CE Fi el d Secur i t y Manager .
The Cont r act or i s r esponsi bl e f or pr ovi di ng har dwar e t hat i s compat i bl e wi t h t he speci f i ed Sof t war e House C- Cur e 9000 Syst em. Compat i bi l i t y i s def i ned as manuf act ur er speci f i ed nor mal oper at i on f or t he r espect i ve har dwar e, sof t war e, and har dwar e/ sof t war e combi ned use.
Cont r act or s nat i onwi de have var yi ng l evel s of exper i ence and exper t i se i n t he secur i t y wor k speci f i ed t hr oughout t hi s SOW.
The Cont r act or wi l l pr ovi de and i nst al l a new Aut o- Face VI Det ent i on Cont r ol Boar d t hat wi l l i nc l ude:
a. Four t een access cont r ol out put boar ds,
b. Ten access Cont r ol i nput boar ds,
c. One power suppl y and AC/ DC conver t er s,
d. Al l r equi r ed Access Cont r ol Syst em i nt egr at i on wi r i ng,
e. Thr ee Access Cont r ol boar d cabi net s, f . Al l suppl ement al wi r i ng,
g. Cont r ol appl i cat i on swi t ch opt i ons compat i bl e wi t h cust omer requirements,
h. Al l Access Cont r ol pr ogr ammi ng, i . Wi r i ng t o t er mi nal bl ocks and cust omer connect or s, j . Cust om mat r i x wi r i ng,
k. LED t est di odes, l . Ser i al i nt er f ace, SECTI ON 01 11 00 Page 6
m. Pr ogr ammed annunci at or car ds,
n. Audi bl e al ar ms,
o. Ti me of day c l ock,
p. Speaker and speaker gr i l l ,
q. Mi cr ophone, r . Vol ume cont r ol s,
s. Di spl ay a seven mi l mul t i - col or ed pol yest er gr aphi c det ect i on pl an cover ed by a s i x mi l pr ot ect i ve v i nyl l ami nat e and bonded t o a 1/ 8 i nch i r r i di t ed al umi num subst r at e, t . A non- gl ar e, dur abl e, scr at ch r esi st ant , v i nyl l ami nat e sur f ace f or easy mai nt enance,
u. Cur r ent l i mi t i ng r esi st or s i zed f or s i t e vol t age,
v. Hi gh i nt ensi t y t - 1 3/ 4 LED l i ght s,
w. Sol der t ype t ur r et f or LED connect i on,
x. LED wi r i ng t er mi nat ed on mul t i - pi n connect or s or modul ar scr ew cl amp t ype t er mi nal st r i ps, and
y. Swi t ch wi r i ng t er mi nat ed on mul t i - pi n connect or s or modul ar scr ew- cl amp st r i ps- mount ed on t he r ear of t he encl osur e.
Conf l i c t s bet ween manuf act ur er ' s r ecommendat i ons, speci f i cat i on, and/ or cont r act document s must be r epor t ed i n wr i t i ng t o t he cont r act i ng of f i cer t echni cal r epr esent at i ve f or r esol ut i on.
The Cont r act or i s r esponsi bl e f or damage t o any equi pment , mat er i al s, sur f aces or ot her wor k di sr upt ed as r esul t of t he wor k. Repai r or r emuner at i on wi l l be t he sol e r esponsi bi l i t y of t he Cont r act or . I f such wor k cannot be r epai r ed wi t hi n a r easonabl e t i me, t he Gover nment r eser ves t he r i ght t o r epai r damaged equi pment , mat er i al s or sur f aces and of f set t he cost s f or such r epai r s f r om t he awar ded cont r act pr i ce. The Cont r act or wi l l coor di nat e any ant i c i pat ed ESS downt i me wi t h t he I CE FSM.
Cont r act or pr ovi ded power suppl i es t o ESS equi pment ar e r equi r ed t o be har d wi r ed. Unsecur ed pl ug- i ns t o power suppl i es i s not accept abl e. El ect r i cal wor k r equi r ement s i ncl ude but ar e not l i mi t ed t o Nat i onal El ect r i cal Code ( NEC) NFPA 70 and NFPA 101 - Nat i onal Li f e Saf et y Code.
a. Pr ovi de gr oundi ng at secur i t y devi ce l ocat i on and ensur e pr oper bondi ng t o exi st i ng f aci l i t i es.
b. Ensur e gr oundi ng cont i nui t y by pr oper l y bondi ng appr opr i at e cabl i ng, c l osur es, cabi net s, condui t s, ser vi ce boxes, and head end equipment.
c. Al l gr oundi ng i s t o be per f or med i n accor dance wi t h ANSI - J- STD- 607- A, NEC, NFPA, and l ocal codes and pr act i ces.
d. Power shal l onl y be appl i ed t o t he syst em af t er r e- checki ng f or
SECTI ON 01 11 00 Page 7 pr oper gr oundi ng of t he syst em and measur i ng al l l oops f or l ack of shor t s, gr ounds and open ci r cui t s .
The ESS must be i nst al l ed by, at a mi ni mum, a Jour neyman El ect r oni c or Secur i t y Syst em Techni c i an, wi t h a mi ni mum of f i ve year s exper i ence i n s i mi l ar i nst al l at i on. I f any appr ent i ces ar e used, t hey must be f ul l y super vi sed by an exper i enced j our neyman.
The Cont r act or wi l l pr ovi de an as- bui l t package i ncl udi ng one el ect r oni c PDF f or mat f i l e and t hr ee har d copi es of t he ESS di agr ams i dent i f y i ng t he l ocat i ons of al l ESS component s. Thi s wi l l i nc l ude but i s not l i mi t ed t o f l oor pl ans, r i ser di agr ams, por t char t s, door det ai l s and devi ce wi r i ng det ai l s . The as- bui l t package ( book) shal l cont ai n any ot her del i ver abl e i t ems t o i ncl ude document s gener at ed as a r esul t of t he f i nal wal k t hr ough checkl i st and accept ance t est i ng.
A det ai l ed l i s t i ng of al l ESS equi pment ( i ncl udi ng make and model speci f i cat i ons) must be pr ovi ded i n t he Cont r act or ' s bi d f or t echni cal r evi ew by t he FSM t o ensur e compl i ance wi t h I CE' s r equi r ement s.
The Cont r act or must i nt er f ace el ect r i f i ed door har dwar e wi t h a dr y cont act t o a f i r e al ar m r el ay t o pr ovi de f r ee egr ess i n t he event of al ar m act i vat i on wher e r equi r ed by f i r e code. I nst al l at i on of cont act s f or connect i on t o t he f i r e al ar m i s t he Cont r act or ' s r esponsi bi l i t y .
3. 1. 2 Infastructure Infrastructure
The Cont r act or i s t o i nst al l al l wi r i ng i ncl udi ng, but not l i mi t ed t o, communi cat i on and power suppor t necessar y f or t he oper at i on of t he ESS.
Al l wi r i ng shal l consi st of a s i ngl e, unbr oken r un t hat i s f r ee of spl i ces and T- Taps. Wi r i ng f or al l ESS devi ces shal l be t amper r esi st ant . Wi r i ng f or al l ESS f i el d devi ces shal l not be exposed ( i . e. , must be i nt er nal t o a secur e space wal l , cei l i ngs, door f r ames, et c. ) upon i nst al l at i on. Wi r i ng f or al l ESS component s shal l r emai n wi t hi n I CE space t o t he f ul l est ext ent possi bl e. When i t i s not f easi bl e f or wi r i ng t o r emai n i nt er nal t o I CE space t he Cont act or shal l pr ovi de a t amper r esi st ant or condui t sol ut i on.
Wr i t t en appr oval by t he I CE Fi el d Secur i t y Manager i s r equi r ed f or any wi r i ng t o be pl aced ext er nal of I CE cont r ol l ed space.
I n compl i ance wi t h NFPA 70 NEC and as pr escr i bed by t he manuf act ur er , f or PACS car d r eader s, al l cabl i ng shal l be pl enum- gr ade, l i s t ed as havi ng adequat e f i r e- r esi st ant and l ow smoke- pr oduci ng char act er i s t i cs.
Addi t i onal l y, f or PACS, t he Cont r act or shal l ensur e t hat al l cabl i ng wi t hi n t he encl osur e does not exceed one spar e pai r per cabl e and i s pr oper l y t er mi nat ed wi t h a s l eeve t o pr event unr avel i ng/ unwi ndi ng.
For PACS r enovat i on pr oj ect s, t he Cont r act or i s r equi r ed t o r emove t he exi st i ng access cont r ol i nf r ast r uct ur e i ncl udi ng cont r ol l er s, car d r eader s and r eader modul es, power suppl i es, door posi t i on swi t ches, r equest - t o exi t devi ces, and cabl i ng. The Cont r act or may r euse t he exi st i ng el ect r i f i ed l ock set s. I f t he Cont r act or chooses t o r euse t he exi st i ng el ect r i f i ed l ock set s, t he Cont r act or shal l mai nt ai n and at no cost t o t he gover nment t hese l ocks set s dur i ng t he war r ant y per i od. I f t he Cont r act or cannot r emove exi st i ng cabl e, t hey shal l t er mi nat e al l cabl e ends and t ag t he cabl e as “ Abandoned Secur i t y Wi r e” and shal l not r e- use any por t i on of t he l egacy PACS wi r e i n t he new PACS.
The Cont r act or shal l secur el y f ast en al l ESS wi r i ng above dr op cei l i ngs t o
SECTI ON 01 11 00 Page 8 pr ovi de adequat e suppor t i n an appr oved met hod and per t he l at est ver si on of t he GSA PBS- P100 Faci l i t i es St andar ds f or t he Publ i c Bui l di ng Ser vi ce and t he Nat i onal El ect r i c Code ( NEC) . No wi r i ng may be di r ect l y i n cont act wi t h acoust i cal cei l i ng t i l es. When r epl aci ng exi st i ng secur i t y syst em wi r i ng t he Cont r act or must r emove abandoned ESS wi r i ng i n t he cei l i ng. Li ne secur i t y t o end devi ces shal l be i mpl ement ed t hr ough End- of - Li ne r esi st or s i nst al l ed at t he devi ce.
Hi gh secur i t y scr ews must be used f or al l ESS component s t hat ar e exposed ( i . e. , can be v i ewed ext er nal l y or ar e not secur ed behi nd a f ace pl at e) .
Al l wi r i ng shal l be l abel ed at bot h ends usi ng a numer i cal syst em t o al l ow f or i dent i f i cat i on. The wi r e l abel i ng conf i gur at i on shal l be cal l ed out on t he as- bui l t ESS dr awi ngs t o be pr ovi ded and ver i f i ed dur i ng f i nal wal k t hr ough and accept ance.
Al l gr oundi ng i s t o be per f or med i n accor dance wi t h ANSI - J- STD- 607- A, NFPA 70 NEC and l ocal codes and pr act i ces. Gr oundi ng f or al l el ect r i cal wor k per f or med by t he Cont r act or shal l i ncl ude, but i s not l i mi t ed t o, t he hi ghl i ght s bel ow:
a. Pr ovi de gr oundi ng at secur i t y devi ce l ocat i on and ensur e pr oper bondi ng t o exi st i ng f aci l i t i es.
b. Ensur e equi pment r acks ar e pr oper l y gr ounded t o f aci l i t y gr oundi ng buss bar .
c. Ensur e gr oundi ng cont i nui t y by pr oper l y bondi ng appr opr i at e cabl i ng, c l osur es, cabi net s, condui t s, ser vi ce boxes, and head end equipment.
d. Power shal l onl y be appl i ed t o t he syst em af t er r e- checki ng f or pr oper gr oundi ng of t he syst em and measur i ng al l l oops f or l ack of shor t s and open ci r cui t s.
The Cont r act or wi l l pr ovi de l ockabl e el ect r oni cs equi pment r ack( s) , mount s, s l i des, shel ves and ot her necessar y i t ems t o i nst al l and mount har dwar e.
The Cont r act or ’ s pr oposal must i dent i f y by squar e f oot age al l wal l and f l oor space r equi r ement s f or r ack and wal l mount ed equi pment . The Cont r act or ’ s pr oposal must i dent i f y by amper age al l ESS power r equi r ement s t o ensur e appr opr i at e r at ed c i r cui t br eaker s ar e i nst al l ed i n power panel s suppor t i ng t he equi pment .
The Cont r act or shal l coor di nat e wi t h GSA and OAFM t o r equest t hat al l secur i t y equi pment be on i t s own dedi cat ed el ect r i cal c i r cui t . The secur i t y t echni c i an i s not r esponsi bl e f or t hi s; a l i censed el ect r i c i an wi l l need t o make sur e t hi s i s accompl i shed.
The Cont r act or i s t o pr ovi de and i nst al l al l equi pment associ at ed power f or ESS oper at i on. Al l ESS management and backend equi pment ( i . e. , r eader cont r ol l er s, I DS panel s, et c. ) i s t o be i nst al l ed i n t he sui t e’ s I T LAN r oom, secur i t y equi pment r oom or ot her secur ed ar ea, wi t h appr oval by t he FSM. The Cont r act or wi l l ensur e each equi pment r oom cont ai ns suf f i c i ent HVAC ai r c i r cul at i on and condi t i oni ng t o suppor t el ect r oni c equi pment r equi r ement s. I n each desi gnat ed equi pment r oom, hi gh qual i t y f i r e r at ed pl ywood, or bet t er , must be i nst al l ed by t he Cont r act or t o suppor t wal l mount ed backend equi pment ( i . e. , panel s, power suppl i es, et c. ) .
SECTI ON 01 11 00 Page 9
The Cont r act or shal l pr ovi de and i nst al l a mi ni mum of an ei ght - hour emer gency power sol ut i on f or al l ESS har dwar e. The power sol ut i on can be pr ovi ded t hr ough t he use of bat t er i es, emer gency gener at or s, UPS, or a combi nat i on t her eof t o meet t he r equi r ement s.
I f emer gency power i s avai l abl e, v i a gener at or , a bat t er y backup must be pr ovi ded t o cover t r ansf er t i me.
Unl ess speci f i ed di f f er ent l y by t he manuf act ur er , PACS power suppl i es have 12 Vdc/ 18ah bat t er i es. Any bat t er i es f or I DS panel s shal l have no l ess t han a 12 Vdc/ 7ah bat t er y each, unl ess speci f i ed di f f er ent l y by t he manuf act ur er .
For uni nt er r upt abl e power suppl y ( UPS) i nst al l at i ons t he UPS must have sur ge pr ot ect i on and l i ne condi t i oni ng f eat ur es.
Power suppl i es t o ESS equi pment shal l be wi r ed t o mi ni mi ze l i kel i hood of acci dent al di sconnect . Unsecur ed pl ug- i ns t o power suppl i es not l ocat ed i n a r ack or encl osur e ar e not accept abl e.
The Cont r act or shal l ensur e t hat al l power suppl i es ar e r at ed t o power t he maxi mum l oad pl us a mi ni mum of 10 per cent spar e capaci t y. I CE def i nes maxi mum l oad as t he s i mul t aneous use of al l devi ces at t hei r maxi mum cur r ent r equi r ement s.
The Cont r act or shal l suppl y vol t age l oad cal cul at i ons f or each El ect r i cal / LAN cl oset t hat suppor t s t he PACS. The Cont r act or shal l cal cul at e power suppl i es and back- up capaci t y by maxi mum l oad. Separ at el y, t he Cont r act or shal l cal cul at e nomi nal power and t ypi cal dut y- cycl e t o det er mi ne t he dur at i on of t he back- up syst em.
The Cont r act or shal l ensur e t hat al l power suppl i es t o PACS panel ( s) ar e co- l ocat ed. The Cont r act or shal l ensur e t hat new power suppl i es ar e opt i oned t o t r ansmi t a t r oubl e condi t i on t o t he PACS when t he f ol l owi ng condi t i ons exi st : ( a) l ow bat t er y and ( b) AC f ai l .
The Cont r act or shal l ensur e out put s ar e i ndi v i dual l y f used and suf f i c i ent f or t he connect ed l oad. The Cont r act or shal l ensur e t hat al l bat t er y cal cul at i ons ar e based upon peak usage ( i . e. , s i mul t aneous use of al l devi ces) . The Cont r act or shal l pr ovi de bat t er i es suf f i c i ent l y s i zed t o suppor t t he st and- by r equi r ement s.
I n compl i ance wi t h NFPA 101 Li f e Saf et y Code means of egr ess st andar ds and as det er mi ned f r om t he pr e- const r uct i on s i t e wal kt hr ough t he Cont r act or shal l ensur e t hat al l door s ar e pr oper l y wi r ed f or ei t her f ai l saf e or f ai l secur e mode of oper at i on. Al l egr ess pat h door s, unl ess ot her wi se desi gnat ed by t he FSM, schedul ed wi t h el ect r oni c har dwar e shal l unl ock f r om i nsi de t he f aci l i t y upon act uat i on of a l i f e saf et y devi ce or f i r e al ar m.
Cabl i ng may be bundl ed and l ai d above t he cei l i ng. Label i ng r equi r ed on al l new i nst al l ed cabl es.
3. 1. 3 Physi cal Access Cont r ol Syst em ( PACS) Pr ogr ammi ng
PACS sof t war e must be FI PS- 210- 2, HSPD- 12 compl i ant and capabl e of managi ng cur r ent I CE PI V car ds. The Cont r act or wi l l pr ovi de a compl et ed PACS Paper wor k ( PACS Por t Char t s For m, I nput / Out put Boar d For m and as- bui l t dr awi ngs showi ng t he l ocat i on of each car d r eader ) i n or der f or t he I CE PACS Team t o compl et e pr ogr ammi ng and f or t he l ocal I CE Pr ogr am Of f i ce t o
SECTI ON 01 11 00 Page 10 compl et e r el at ed act i ons. Local I CE pr ogr am of f i ce per sonnel ar e r esponsi bl e f or compl et i ng t he Per sonnel Wor ksheet s. Advi ce on est abl i shi ng t he c l ear ance codes and Mast er Gr ant i ng Aut hor i t y Li st ( MGAL) wi l l be pr ovi ded by t he FSM. The cur r ent ver si on of t he Por t Char t s For m wi l l be pr ovi ded t o t he Cont r act or by t he I CE Fi el d Secur i t y Manager .
Pr i or t o f i nal accept ance t he Cont r act or shal l ensur e a copy of t he I CE- appr oved Por t Char t s i s pl aced i n each PACS panel encl osur e.
3. 1. 4 Car d Reader s Types
The onl y accept abl e car d r eader t ypes f or t hi s pr oj ect ar e t he f ol l owi ng HI D Gl obal Cor por at i on ( HI D) pi vCl ass pr oduct s or appr oved equal :
Model Number : pi vCLASS RP40 Descr i pt i on: Wal l Swi t ch Cont act l ess Reader Par t Number and Conf i gur at i on: 920PHRNEK00005
Model Number : pi vCLASS RPK40 Descr i pt i on: Wal l Swi t ch Cont act l ess Keypad Reader ( wi t h PI N validation) Par t Number and Conf i gur at i on: 921PHRNEK0002G
Model Number : pi vCLASS RP10 Descr i pt i on: Mi ni - Mul l i on Cont act l ess Reader Par t Number and Conf i gur at i on: 900PHRNEK00005
The Cont r act or shal l ensur e car d r eader s ar e f act or y conf i gur ed wi t h a 75- Bi t f or mat r ead. Car d r eader f i el d modi f i cat i ons ( or f i el d f l ashi ng) ar e not aut hor i zed.
The Cont r act or shal l ensur e t hat t he car d r eader s ar e i nst al l ed i n compl i ance wi t h t he Amer i can wi t h Di sabi l i t i es Act ( ADA) and Uni f or m Feder al Accessi bi l i t y St andar ds ( UFAS) and pr ovi de t he f ol l owi ng audi o/ v i sual i ndi cat i on:
a. An audi o beeper pr ovi di ng var i ous t one sequences t o s i gni f y:
access gr ant ed and access deni ed.
b. A c l ear v i sual st at us on t he hi gh- i nt ensi t y l i ght bar f or :
( 1) Red - access deni ed, ( 2) Gr een - access gr ant ed, and
( 3) Amber - syst em busy or t r oubl e.
c. The Cont r act or shal l i nt er f ace t he PACS i nt o t he ADA/ UFAS aut omat i c door opener s.
3. 1. 5 Car d Reader Spacer s
Each car d r eader shal l be mount ed wi t h an HI D r eader spacer , par t number 6132AK, t o i nt er f er ence wi t h met al j unct i on boxes, wal l mat er i al such as met al mesh, back- t o- back r eader l ocat i ons, et c.
3. 1. 6 Out door Car d Reader
Each out door car d r eader wi l l be i nst al l ed wi t h HI D gasket k i t I P65GSKT- ### ( model dependent ) or appr oved equal .
SECTI ON 01 11 00 Page 11
3. 1. 7 Car d Reader I nst al l at i on
Car d r eader s shal l be i nst al l ed on t he same si de as t he door handl e, unl ess speci f i ed ot her wi se by t he FSM. The mi ni - mul l i on r eader s i dent i f i ed i n t hi s document ar e accept abl e onl y on nar r ow- f r amed or al umi num- f r ame gl ass t ype ( st or e f r ont ) door s. Al l ot her mul l i on car d r eader i nst al l at i ons shal l r equi r e t he wr i t t en appr oval of t he FSM.
Car d r eader - cont r ol l ed door s shal l be connect ed t o a Door St at e Moni t or ( DSM) and Request - t o- Exi t ( REX) devi ce f or oper at i on of t he door .
The Cont r act or shal l conf i gur e door s wi t h a REX devi ce so an aut hor i zed egr ess f r om t he secur e ar ea does not cause an al ar m. No REX devi ce i s necessar y i f t he door i s cont r ol l ed by a car d r eader on bot h s i des.
a. REX devi ces can be push- but t on, mot i on sensor s or i ncor por at ed i n t he mor t i se el ect r i f i ed l ockset and shal l shunt t he al ar m, not r el ease t he l ocki ng mechani sm, unl ess speci f i ed ot her wi se by appl i cabl e NFPA 101 Li f e Saf et y Codes or t he AHJ.
b. The Cont r act or shal l ensur e t hat t he REX i s a l i s t ed devi ce f or t he speci f i c oper at i on t o pr ovi de del ay t i me t o t he DSM t o pr event f al se al ar ms and i s i nst al l ed and conf i gur ed t o pr event act i vat i on by nor mal movement i nsi de t he secur e ar ea.
c. The Cont r act or shal l ensur e t hat t he REX r emai ns act i ve f or a maxi mum dur at i on of f i ve seconds and t hat t he t i mer i s non- r eset t abl e.
d. Cr ash bar / del ayed egr ess exi t devi ces i nst al l ed on door s must be appr oved by t he FSM and shal l have a l ocal annunci at or .
The Cont r act or shal l ensur e t he DSM connect s as an i nput or out put di r ect l y t o t he PACS panel s f or communi cat i on t o I CE' s Ent er pr i se CoCURE 9000 ser ver . PACS shal l not i nt er f ace wi t h doubl e- pol e, doubl e- t hr ow ( DPDT) swi t ches t hat i nt er f ace t o t he I DS.
a. For al l car d r eader equi pped door s t he Cont r act or shal l i nst al l a DSM t hat moni t or s t he posi t i on of t he door so t hat a f or ced- door or hel d- open door causes an al ar m.
b. The DSM shal l be conceal ed, a sel f - l ock mount i ng, have r ugged construction, 3/ 4 i nches i n di amet er , ABS pl ast i c encl osur e, be a her met i cal l y seal ed r eed swi t ch, be of hi gh secur i t y, and i s s i mi l ar i n col or t o t he door f r ame.
3. 1. 8 Locks
El ect r i c st r i kes, el ect r i f i ed mor t i se l ockset s and magnet i c l ocks ar e accept abl e l ocki ng mechani sms f or t hi s pr oj ect . Al l l ocki ng mechani sms ar e t o r et ur n t o a l ocked st at e i mmedi at el y af t er use or wi t hi n t hr ee seconds of non- use, unl ess speci f i ed di f f er ent l y by t he I CE Fi el d Secur i t y Manger .
El ect r i c l ocki ng mechani sms must meet UL 1034, St andar d f or Bur gl ar y- Resi st ant El ect r i c Locki ng Mechani sms and be bur gl ar y- r esi st ant l i s t ed. Addi t i onal l y, el ect r i c st r i kes must meet Amer i can Nat i onal St andar d f or El ect r i c St r i kes and Fr ame Mount ed Act uat or s - ANSI / BHMA A156. 31, Gr ade 1 ( Cycl e 500, 000, St at i c St r engt h- Vol t age at 100 per cent and 85 per cent of r at ed = 1500 pounds, Dynami c St r engt h- Vol t age at 100 per cent and 85 per cent of r at ed = 70 f t . l b. ( 95J ).
SECTI ON 01 11 00 Page 12
Addi t i onal el ect r i c st r i ke speci f i cat i ons:
a. Const r uct i on: St ai nl ess st eel , t amper r esi st ant , i nt er nal sol enoi d
b. Oper at i on: Fi el d r ever si bl e, pl ug- i n connect or s
c. Sol enoi d: I nt er nal l y mount ed t o f aci l i t at e el ect r i c st r i ke i nst al l at i on i n hol l ow met al , concr et e f i l l ed, and al umi num and wood j ambs, oper at ed by di r ect cur r ent t o pr ovi de s i l ent oper at i on
d. El ect r i c St r i ke: Capabl e of oper at i on wi t h l ess t han 30 pounds of f or ce agai nst keeper
Addi t i onal magnet i c l ock speci f i cat i ons:
a. 600 pounds hol di ng f or ce t o be pl aced cont r ol l ed i nt er i or r ooms and secur e ar eas wi t hi n bui l di ngs
b. 1200 pouonds hol di ng f or ce t o be pl aced on det ent i on and per i met er doors
c. Magnet i c l ock shal l have magnet i c bond sensor
d. Power over r i de sol ut i on t o be pr oposed f or door s not i dent i f i ed as f ai l saf e
3. 1. 9 Ot her Door Har dwar e
For car d r eader - cont r ol l ed door s t he Cont r act or shal l pr ovi de and i nst al l :
a. A f ace pl at e whi ch wi l l pr event t he l ock bol t f r om bei ng r et r act ed f r om t he unsecur e s i de of t he door or i nst al l a door st r i ke t hat engages t he guar d bol t or auxi l i ar y dead l at ch l ocat ed on door har dwar e.
b. A f unct i oni ng heavy- dut y door c l oser . LCN 4010 ser i es or appr oved equal . Hi gh st r engt h cast i r on or cast al umi num cyl i nder For ged st eel mai n ar ms one pi ece f or ged st eel pi st on doubl e heat t r eat ed 3/ 4 i nch di amet er st eel pi ni on al l - weat her - per f or ms t o t emper at ur e r anges f r om 120 degr ees Fahr enhei t ( F) ( 49 degr ees Cent i gr ade ( C) ) t o mi nus 30 degr ees F ( mi nus 35 degr ees C) wi t hout any seasonal adj ust ment Hi gh ef f i c i ency, cast i r on cyl i nder wi t h f ul l compl ement , l ow f r i c t i on bear i ngs t amper r esi st ant r egul at i ng scr ews f ul l r ack and pi ni on hydr aul i c act i on qual i t y and dur abi l i t y spr i ng f or ce i ndi cat or 30- year war r ant y powder coat ed f i ni sh Uni ver sal non- handed Adj ust abl e spr i ng s i zes 1- 6 Test ed and cer t i f i ed under ANSI / BHMA A156. 4 Gr ade 1.
c. Al l deadbol t s wi t h mi ni mum 1- i nch t hr ow on per i met er or hi gh secur i t y door s shal l be i ndependent act i on, not i nt egr at ed wi t h t he car d r eader s. The Cont r act or shal l coor di nat e wi t h t he FSM on whi ch hi gh secur i t y door s need deadbol t s. As speci f i ed i n t he I CE FDG, t he deadbol t s r equi r ed f or al l I CE per i met er door s, HSI Sei zed Evi dence St or age Rooms and HSI Comput er For ensi cs Lab shal l be Under wr i t er s Labor at or i es ( UL) l i s t ed under UL437 and cer t i f i ed under Amer i can Nat i onal St andar ds I nst i t ut e ( ANSI ) / Bui l der ' s Har dwar e Manuf act ur er ' s Associ at i on ( BHMA) cer t i f i cat i on A156. 30, Level s M1AAAM and ANSI / BHMA A156. 5, Gr ade 1. I n t he event t he deadbol t i s not i nt egr at ed i nt o t he Heavy- Dut y Gr ade 1 Mor t i sed Har dwar e st or er oom f unct i on l ock, bot h t he l ock and cyl i nder ( or cor e) must meet or exceed t he l i s t i ng and
SECTI ON 01 11 00 Page 13 cer t i f i cat i on r equi r ement s speci f i ed above.
d. Tr ansf er hi nge f or el ect r i f i ed l ockset or REX devi ces or appr oved equal , as necessar y.
e. The Cont r act or wi l l coor di nat e wi t h t he Pr oj ect Team t o ensur e t her e ar e no conf l i c t s bet ween door har dwar e and door or door f r ames.
f . Pani c/ cr ash bar s on ext er i or door s and door s i n R&D must meet or exceed:
Wi t hst ands over 1400 pounds of st at i c pul l f or ce f or gr eat er secur i t y must r el ease a magnet i c l ock secur e met hod of knob doggi ng mount i ng pl at e and st r i ke l ocat or Lef t or r i ght handed weat her pr oof al umi num f i ni sh UL r at ed and appr oved.
g. I nt er i or f i r e door s must have a pani…