REVISED__2_Purchase_Description_-_Penetrant_Inspection_System.docx

DOCX document 16 KB Posted

Attached to
RFQ - Penetrant Inspection System Federal contract opportunity
Solicitation number
W912NS-19-Q-1006
Issued by
Department of the Army Missouri Army National Guard

About this file

Updated Purchase Description

View the file

Other files for this federal contract opportunity

Other files attached to RFQ - Penetrant Inspection System, newest first.
File Type Posted
B8-2-1_-_REVISED__3_Purchase_Description_.docx DOCX document
Question__2.docx DOCX document
MIL-PRF-32531.pdf PDF
Round_1_Q&A_.docx DOCX document
Purchase_Description_-_Penetrant_Inspection_System.docx DOCX document
Combined_Synopsis_-_Solicitation.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLIN 0001) Penetrant Inspection System - Quantity 1 EA Meet or exceed the following Essential Physical Characteristics:

Overall Characteristics

· Overall length of at least 45 feet, not to exceed 50 feet

· Unit will be assembled in a straight line layout

· 11 Stations consisting of Penetrant Station, Drain Station, Pre-Wash Station, Emulsifier Station, Post-Wash Station, Drain Station, Dryer Station, Rest Station, Dry Developer Station, Rest Station, and an Inspection Station. Station Characteristics listed below.

· Ability to accept parts weighing at least 100 pounds, and a minimum of parts 30 inches in length at all stations

· All stations will be connected with a roller grille between stations

· All stations must be compatible with the entire unit

· Quote shall include installation and set-up, with training of up to 5 individuals on use of the complete installed system.

· Must Meet or exceed Specifications listed in MIL-PRF-32531

· Class A – Unpowered tank

· Standard Form – Left to Right Processing

· Size 4 on all stations Station 1 - Penetrant Station Characteristics

· Designed for the use of the penetrant dip method

· Tank constructed of Stainless steel

· Manual controls to dip parts into penetrant tank

· Fitted with drain to allow for complete draining Station 2 – Drain Station

· Stainless steel drain pan

· Full Roller grille

· Fitted with drain to allow for complete draining Station 3 – Pre-Wash Station

· Powered by 115 VAC, 60Hz, Single Phase

· Tank constructed of Stainless steel

· Fitted with water temperature gauge, pressure regulator and gauge, wash gun and hose

· Fitted with drain to allow for complete draining Station 4 – Emulsifier Station

· Tank constructed with stainless steel

· Controls to lower parts into emulsifier station

· Air agitation system

· Fitted with drain to allow for complete draining

Station 5 – Post Wash Station

· Powered by 115 VAC, 60Hz, Single Phase

· Tank constructed of stainless steel

· Controls to lower part into wash station

· Fitted with water temperature gauge, pressure regulator and gauge, wash gun and hose

· LED UV-A Inspection Lamp

· Fitted with drain Station 6 – Drain Station

· Constructed of stainless steel

· Roller Grille Station 7 – Drier Station

· Powered by 480/240 VAC, 60 HZ, 3 PH

· Electrically heated with digital temperature controller

· Ability to maintain temperature of at least 150 degrees

· Safety shutoff at 180 degrees

· Controls or functions to limit humidity in chamber Station 8 – Rest Station

· Full roller grille Station 9 – Dry-Developer Station

· Powered by 115 VAC, 60Hz, Single Phase

· Pneumatic Vertically lifting doors with safety stops to prevent injury in event door opening device fails

· Adjustable automatic process cycle system

· Injector and Vacuum system Station 10 – Rest Station

· Full roller grille

· Dust pan Station 11 – Inspection Station

· Powered by 115 VAC, 60Hz, Single Phase

· Fully enclosed with flame retardant curtains

· Handheld UV Lamp with a minimum of 5,000 μW/cm2 irradiance at 15 in

· Mounting bracket for UV Lamp

· White lights mounted in inspection station

· Ventilation fan with light proof enclosure