Bldg_545_ELEC_FINAL_04-11-2011.pdf

PDF 28 MB Posted

Attached to
ELECTRONIC ACCESS CONTROL SYSTEM (ACS) Federal contract opportunity
Solicitation number
W912LR18R0038
Issued by
Department of the Army

View the file

Other files for this federal contract opportunity

Other files attached to ELECTRONIC ACCESS CONTROL SYSTEM (ACS), newest first.
File Type Posted
Revised_PWS_Areas_of_Control_Defined.pdf PDF
USPFO-PR_Bldg_540_Electrical-lighting-Power_Floor_Plans.pdf PDF
Tele_Security_Plan_Bldg_545.pdf PDF
Pre-Bid_Conference_Attendees.pdf PDF
Solicitation.pdf PDF
Performance_Work_Statement.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELECTRICAL ABBREVIATIONS

LIGHTING SYMBOLS

DISTRIBUTION EQUIPMENT SYMBOLS

WIRING DEVICE SYMBOLS

SWITCH AND CONTROL SYMBOLS

WIRING SYMBOLS

RISER DIAGRAM SYMBOLS

M

G

SM

GFP

PE

M

TVSS

A, AMP

AC

AF

AHU

ANN

AO

AP

AT

AFF

AFC

ELEV ELEVATOR

AIC

POWER CONTROL MONITORING SYSTEM

AIR HANDLING UNIT

AFG ABOVE FINISHED GRADE

GFCI

ISOLATED GROUND

WYE

AMPERE

AMPERE INTERRUPTING CAPACITY

RECTIFIER

TELEVISION

ABOVE FINISHED FLOOR

ELECTRIC HEATING COIL

ELECTRIC HEAT TRACE

FIRE ALARM CONTROL PANEL

HAND-OFF-AUTOMATIC

INTERCOMMUNICATION

FLUORESCENT

IMPEDANCE

TRANSFORMER

WATT

VARIABLE FREQUENCY DRIVE

VOLTMETER

VOLT AMPERE

ALTERNATING CURRENT

AMPERE FRAME

ANNUNCIATOR

ANALOG OUTPUT

ANNUNCIATOR POINT

AMPERE TRIP

CIRCUIT BREAKER

DATA GATHERING PANEL

IESNA

EXISTING TO REMAIN

EQUIP

EQ,

POWER TRANSFORMER

PAN-TILT-ZOOM

PHASE

GROUND FAULT INTERRUPTER

RECESSED ROUND WALL WASHER. TRIANGLE POINTS TO WASHED WALL

RECESSED ROUND CORNER WALL WASHER. TRIANGLE POINTS TO WASHED WALL

SEMI-RECESSED RECTANGULAR WALL WASHER. TRIANGLE POINTS TO WASHED WALL

FLUORESCENT STRIP FIXTURE

LETTERS CORRESPOND TO SWITCH.

FIXTURE WITH DUAL BALLASTS FOR INBOARD/OUTBOARD SWITCHING OF LAMPS.

TRACK LIGHTING FIXTURE WITH HEADS

ROUND PENDANT LIGHT FIXTURE

MOTOR RATED TOGGLE SWITCH

MOTOR CONNECTION

VARIABLE FREQUENCY DRIVE

PHOTO ELECTRIC RELAY

PANELBOARD DESIGNATION KEY:

CONDUIT OR CABLE CONCEALED IN WALLS OR ABOVE CEILINGS

CONDUIT OR CABLE EXPOSED

CONDUIT OR CABLE UNDER RAISED FLOOR

LOW VOLTAGE CABLE

CONDUIT OR CABLE TURNING UP

CONDUIT OR CABLE TURNING DOWN

CONDUIT OR CABLE CHANGE IN ELEVATION

CONDUIT CAPPED

SWITCH LEG CONNECTED TO SWITCH "a".

LUG CONNECTION

FUSED DISCONNECT SWITCH

TRANSIENT VOLTAGE SURGE SUPPRESSOR

ELECTRIC METER

GROUND FAULT PROTECTION

CURRENT TRANSFORMER

DRAW-OUT POTENTIAL TRANSFORMER WITH PRIMARY FUSE

GENERATOR

T

E u

E xE

E u

ST

ST

GENERAL NOTES

SITE ELECTRICAL SYMBOLS

E

T

T

ELECTRONIC SECURITY SYSTEM SYMBOLS

S

AWG AMERICAN WIRE GAUGE

COMMUNICATIONS SYSTEMS SYMBOLS

WALL MOUNTED EQUIPMENT RACK

C u

Cu x

TV

M. CAHILL

D. MONAHAN

L. PEREZ

E-001

G

G

A LIGHTNING PROTECTION AIR TERMINAL (LIGHTNING ROD)

LIGHTNING PROTECTION TEE TAP

LIGHTNING PROTECTION THRU-ROOF CONNECTION

GROUND ROD WITH WELDED CONNECTION

WELDED GROUND CONNECTION

BOLTED GROUND CONNECTION

GROUNDING CONDUCTOR - BURIED

GROUNDING CONDUCTOR - EXPOSED

GROUND COUNTERPOISE

GROUND COIL

LIGHTNING PROTECTION SYMBOLS

NEW POWER POLE

EXISTING POWER POLE

PRIMARY UNDERGROUND ELECTRIC CABLE

N1 = NEMA1, N3R = NEMA 3R, N4X = NEMA 4X, N12 = NEMA 12

TEST WELL

MOUNTED 60" AFF UON.

600V, 3-POLE, 30A SWITCH, 30A FUSES, SIZE 1 STARTER, IN NEMA 1 ENCLOSURE,

COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH:

UON.

600V, 3-POLE, 30A SWITCH, 30A FUSES, IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF

FUSIBLE DISCONNECT SWITCH:

DIRECT CURRENT

DISTRIBUTION PANEL

DOUBLE POLE DOUBLE THROW

EMPTY CONDUIT

PRIVATE BRANCH EXCHANGE

SYSTEM CONTROL PANEL

TERMINAL

ELECTRIC WATER COOLER

DIGITAL INPUT

DISCONNECT

DIGITAL OUTPUT

FULL LOAD AMPERES

HIGH VOLTAGE

HIGH PRESSURE SODIUM

HANDHOLE

GROUND

GAUGE

FULL VOLTAGE

FEEDER

LIGHTING

WYE-DELTA

WATTMETER

CONDUIT

DIRECT DIGITAL CONTROL PANEL

POLYVINYL CHLORIDE

RADIO FREQUENCY INTERFERENCE

ROOT MEAN SQUARE

SWITCHBOARD

TERMINAL BOX OR TERMINAL BOARD

TIME DELAY

TELEPHONE TERMINAL

VOLT, VOLTAGE

DOUBLE POLE SINGLE THROW

ELECTRICAL METALLIC TUBING

HAZARDOUS

QUANTITY

SHIELDED TWISTED PAIR

DIAMETER

POLE

POWER FACTOR

HERTZ

HEIGHT

HORSEPOWER

WEATHERPROOF

CONTROL SWITCH

POSITIVE

RECEPTACLE

RIGID GALVANIZED STEEL

SINGLE POLE

START-STOP

SWITCH

TELEPHONE

DEMAND METER

DRY TYPE

FOOTCANDLE

HIGH POWER FACTOR

EQUIPMENT

ENCLOSURE

STANDARD

FUTURE

GENERAL NOTES

ABBREVIATIONS /

ELECTRICAL SYMBOLS /

GROUND ROD

S

V

FIXED CCTV CAMERA (BACKBOX AND CONDUIT ONLY, CAMERA NIC)

LIGHTING CONTROL PANEL

PAN-TILT-ZOOM CCTV CAMERA (BACKBOX AND CONDUIT ONLY, CAMERA NIC)

PASSIVE INFRARED EXIT SENSOR (BACKBOX AND CONDUIT ONLY, SENSOR NIC)

CARD READER (BACKBOX AND CONDUIT ONLY, CARD READER NIC)

INTERCOM WITH INTEGRATED CCTV CAMERA (BACKBOX AND CONDUIT ONLY, INTERCOM NIC)

SECURITY PANEL

KEYPAD (BACKBOX AND CONDUIT ONLY, SHOWN ON DRAWINGS FOR INFORMATION ONLY, NIC)

AREA NOTIFICATION EQUIPMENT (BACKBOX AND CONDUIT ONLY, NIC).

360 DEGREE PIR/MW MOTION DETECTOR (BACKBOX AND CONDUIT ONLY).

VAULT SEISMIC SENSOR

PANIC HARDWARE (PROVIDED BY DIVISION 28)(FUTURE CONNECTION ONLY, NIC)

ELECTRIC STRIKE (PROVIDED BY DIVISION 28)(FUTURE CONNECTION ONLY, NIC)

BALANCED MAGNETIC SWITCH (PROVIDED BY DIVISION 28)

JUNCTION BOX CONCEALED ABOVE FINISHED CEILING (X DESIGNATES SYSTEM: SECURITY, CCTV)

PUBLIC ADDRESS VOLUME CONTROL

PA HORN

EXISTING COMMUNICATION UNDERGROUND DUCT BANK

CEILING MOUNTED INTERIOR PUBLIC ADDRESS SYSTEM SPEAKER

COMMUNICATION UNDERGROUND DUCT BANK

CABLE TRAY

FULL SIZED FLOOR MOUNTED CABINET WITH CABLE MANAGEMENT ACCESSORY

CABLE TELEVISION WALL OUTLET ROUGH-IN WITH BLANK COVERPLATE.

TELECOMMUNICATION CONSOLIDATION POINT

CM - CEILING MOUNTED

SM - SURFACE MOUNTED

RC9AM2TC SERIES POKE-THRU ASSEMBLED UNIT.DESIGN: WIREMOLD

�" AND 2" TRADE SIZE THREADED CONDUIT OPENINGS AND CLOSURE PLUGS. BASIS OF

FLOOR MOUNTED TELECOM POKE-THRU FURNITURE ASSEMBLED UNIT WITH COMBINATION 1

DATA OUTLET WITH TWO RJ45 CAT.6 JACKS IN FLOOR MOUNTED BOX.

IN FLOOR MOUNTED BOX.

COMBINATION VOICE/DATA OUTLET WITH TWO RJ45 CAT. 6 JACKS.

WIRELESS ACCESS POINT OUTLET

CEILING MOUNTED PROJECTOR OUTLET.

W - WALL MOUNTED

TELEPHONE OUTLET

CLASS INSTRUCTOR VOICE/DATA/PROJECTOR OUTLET WITH FOUR RJ-45 CAT6 JACKS.

M - MODULAR FURNITURE

COMBINATION VOICE/DATA OUTLET - COVERPLATE WITH TWO RJ-45 CAT6 JACKS.

DISTRIBUTION PANEL

BACKUP, DP-DISTRIBUTION PANEL, MDP-MAIN RECEPTACLE PANEL, EM-GENERATOR

PANEL DESIGNATOR: PP-POWER PANEL, MP-MECHANICAL PANEL, LP-LIGHTING PANEL, RP -

FACILITY

CENTER/PHYSICAL TRAINING, E-MAINTENANCE WORKBAY, F-CHEMICAL WASTE HANDLING

BUILDING: A-ADMINISTRATION, B-UNIT STORAGE, C-CLASSROOM ASSEMBLY, D-SIMULATION

PANEL NUMBER

H: HARMONIC CANCELLING)

TRANSFORMER (30kVA, NO LETTER: GENERAL DUTY, K: K-13 RATED, RECESSED MOUNTED PANELBOARD

SURFACE MOUNTED 208/120 PANELBOARD

SURFACE MOUNTED 408/277 PANELBOARD

FEEDER CALLOUT. REFER TO COPPER FEEDER SCHEDULE ON SHEET E-602.

NO INDICATION DENOTES 2- #12 AWG + #12 AWG GROUND IN �" CONDUIT.

BRANCH CIRCUIT WIRING SHALL INCLUDE A MINIMUM #12 AWG GROUND WIRE (NOT SHOWN) UON.

BRANCH CIRCUIT WIRING. #10 INDICATES AWG WIRE SIZE, AND �" INDICATES CONDUIT SIZE. ALL

AND CIRCUIT NUMBERS WITH A 2-POLE BKR AT THE PANEL.

A MULTIPOLE CIRCUIT BKR IS DENOTED. RPA1-2:4 DENOTES ORIGINATING PANEL

CIRCUIT NUMBERS. IF COLON IS USED BETWEEN CIRCUIT NUMBERS THEN

HOMERUN TO PANELBOARD. RPA1-2,4 INDICATES ORIGINATING PANEL AND

CONDUIT OR CABLE IN SLAB OR UNDERGROUND

SYSTEMS.

CEILINGS, FLOORS, WALLS, AND PARTITIONS. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION ON FIRE STOP

PROVIDE FIRE STOPPING FOR ALL ELECTRICAL PENETRATIONS OF RACEWAYS AND BOXES THROUGH FIRE RATED

ALL LIGHTING AND RECEPTACLE BRANCH CIRCUITS SHALL HAVE A SEPARATE NEUTRAL PER CIRCUIT.

DRAWINGS FOR DIMENSIONS.

SCALED AND THE ELECTRICAL CONTRACTOR SHALL REFER TO THE ARCHITECTURAL AND SITE / CIVIL CONSTRUCTION

COORDINATION WITH THE WORK OF OTHER TRADES AND SPACE WILL PERMIT. THE DRAWINGS ARE NOT INTENDED TO BE

INDICATE THE ACTUAL ROUTES OF CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELY AS PROPER

EQUIPMENT AND THE CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY

THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE GENERAL LOCATION OF OUTLETS.

SOME LEGEND SYMBOLS MIGHT NOT BE USED. SEE FLOOR PLANS FOR APPLICABLE DEVICES.

OTHERWISE SHOWN OR NOTED.

ALL MOUNTING HEIGHTS INDICATED ARE MEASURED FROM FINISHED FLOOR TO THE CENTER OF DEVICE UNLESS

ALL ELECTRICAL EQUIPMENT SHALL BE LISTED AND LABELED FOR THE QUALIFIED USE.

PROVIDE MINIMUM #12 AWG WIRE SIZE IN �" CONDUIT FOR ALL BRANCH CIRCUITRY UON.

RESPONSIBILITY TO BALANCE LOADS AMONG PHASES IN PANELBOARDS TO WITHIN 10% OF EACH OTHER.

CIRCUIT NUMBERS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. IT WILL BE THE CONTRACTOR’S

DEVICES WITH EQUIPMENT VENDOR PRIOR TO INSTALLATION.

WORD PROVIDE MEANS "FURNISH AND INSTALL COMPLETE AND READY FOR USE". COORDINATE EXACT LOCATION OF

IT IS THE INTENT OF THE THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION. THE

APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION.

PERFORM ALL WORK IN ACCORDANCE WITH THE 2011 EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL OTHER

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

STATIC GROUND CONNECTION

SHUNT TRIP

SHUNT TRIP PUSH BUTTON

POLE MOUNTED LIGHTNING ARRESTOR

LOAD BREAK DRAWOUT FUSE

CABLE TERMINATION STRESS CONE

POLE MOUNTED FUSED CUTOUT

PANEL BOARD

DRAW OUT CIRCUIT BREAKER

TRANSFORMER

INDICATES CIRCUIT NUMBER

CIRCUIT IDENTIFIER TAG; "M" INDICATES MAIN DEVICE, NUMERAL

TRANSFORMER

BUILDING SERVED:

F - CHEMICAL WASTE HANDLING FACILITY

E - MAINTENANCE TRAINING WORKBAY

D - SIMULATION CENTER/PHYSICAL TRAINING

C - CLASSROOM ASSEMBLY

B - UNIT STORAGE

A - ADMINISTRATION

T- RP A

K: K-13 RATED, H: HARMONIC CANCELLING)

TRANSFORMER (T112 = 112.5kVA, NO LETTER: GENERAL DUTY, 3-WIRE NEMA 5-20R FLOOR MOUNTED FLUSH QUAD FLOOR BOX - TWO 125V, 20A, 1PH, RECEPTACLE

FLOOR MOUNTED FLUSH FLOOR BOX - 125V, 20A, 1PH, 3-WIRE NEMA 5-20R DUPLEX

CM - CEILING MOUNTED

SM - SURFACE MOUNTED

ASSEMBLED UNIT.

DESIGN: WIREMOLD RC7AM2TC SERIES POKE-THRU AND CLOSURE PLUGS. BASIS OF

STEM, COMPLETE WITH ONE�" TRADE SIZE CONDUIT AND TWO�" TRADE SIZE ADAPTERS

FLOOR MOUNTED POWER POKE-THRU ASSEMBLED UNIT WITH 2" TRADE SIZE CONDUIT

GROUND BAR

COORDINATE NEMA CONFIGURATION WITH EQUIPMENT SUPPLIER.

WALL MOUNTED SPECIAL RECEPTACLE 18" AFF TO CENTER OF RECEPTACLE -

TO CENTER OF RECEPTACLE UON. SUBSCRIPTS AS DEFINED ABOVE.

3-WIRE NEMA 5-20R UNDER COMMON COVER PLATE MOUNTED 18" AFF

WALL MOUNTED DOUBLE DUPLEX RECEPTACLE - TWO 125V, 20A, 1PH,

UON. SUBSCRIPTS AS DEFINED ABOVE.

NEMA 5-20R MOUNTED 18" AFF TO CENTER OF RECEPTACLE

WALL MOUNTED SIMPLEX RECEPTACLE - 125V, 20A, 1PH, 3-WIRE

THE FOLLOWING SUBSCRIPTS APPLY TO ALL RECEPTACLE DEVICES:

NEMA 5-20R MOUNTED 18" AFF TO CENTER OF RECEPTACLE UON.

WALL MOUNTED DUPLEX RECEPTACLE - 125V, 20A, 1PH, 3-WIRE

= EXPLOSION PROOF

GREEN TRIANGLE

= COMPUTER RECEPTACLE - ISOLATED GROUND, ORANGE WITH

BOTTOM OUTLET UNSWITCHED

= SWITCHED OUTLET - TOP OUTLET TO BE SWITCHED,

= WEATHERPROOF ENCLOSURE

= GROUND FAULT INTERRUPTER

XP

C

S

WP

GFI

CENTER OF BOX UON.

JUNCTION BOX SURFACE MOUNTED. MOUNT 18" AFF TO

RECEPTACLE. CEILING MOUNTED RECEPTACLE. 125V, 20A, 1PH, 3-WIRE NEMA 5-20R

TO CENTER OF BOX UON.

JUNCTION BOX IN WALL WITH BLANK COVERPLATE. MOUNT 18"AFF

JUNCTION BOX CONCEALED ABOVE FINISHED CEILING.

TO PLANS FOR TYPE AND MODEL NUMBER.

OCCUPANCY SENSOR AND POWER PACK(S). REFER

L = LOW VOLTAGE SWITCH

T = ADJUSTABLE TIMER SWITCH

OS = OCCUPANCY SENSOR/WALL SWITCH

M = MOTOR RATED SWITCH

D = DIMMER (NO SUBSCRIPT- 1200W, SUBSCRIPT 1 - 600W)

4K = FOUR WAY KEYED SWITCH

3K = THREE WAY KEYED SWITCH

4 = FOUR WAY

3 = THREE WAY

K = KEYED SWITCH

DESIGNATION "c". OTHER SUBSCRIPT DENOTES:

TOGGLE SWITCH - LOWER CASE SUBSCRIPT "c" DENOTES SWITCH

LIGHTING FIXTURES).

SUBSCRIPT "D1" DENOTES FIXTURE TYPE D1, SUBSCRIPT "b" DENOTES CONTROLLED BY SWITCH b (TYP FOR ALL

FIXTURE WITH INTEGRAL EMERGENCY BATTERY PACK. CONNECT BATTERY PACK HEAD OF SWITCH.

WALL MOUNTED FIXTURE

WALL MOUNTED FIXTURE WITH INTEGRAL EMERGENCY BATTERY PACK. CONNECT BATTERY PACK AHEAD OF SWITCH.

2’x4’ EMERGENCY FLUORESCENT FIXTURE WITH BATTERY PACK

2’x4’ FLUORESCENT RECESSED FIXTURE (DRAWN TO SCALE)

2’ x 2’ EMERGENCY FLUORESCENT FIXTURE WITH BATTERY PACK

2’ x 2’ FLUORESCENT FIXTURE

1’x4’ FLUORESCENT RECESSED FIXTURE (DRAWN TO SCALE)

1’x4’ FLUORESCENT EMERGENCY FIXTURE WITH BATTERY PACK.

FLUORESCENT STRIP EMERGENCY FIXTURE WITH BATTERY PACK

ILLUMINATED FACE(S) OF SIGN) WITH BATTERY PACK.

WALL MOUNTED EXIT SIGNS WITH ARROWS AS INDICATED (SHADING INDICATES

INDICATES ILLUMINATED FACE(S) OF SIGN) WITH BATTERY PACK.

CEILING OR PENDANT MOUNTED EXIT SIGNS WITH ARROWS AS INDICATED (SHADING

DIRECT/INDIRECT PENDANT MOUNTED EMERGENCY FLUORESCENT FIXTURE WITH BATTERY PACK.

DIRECT/INDIRECT PENDANT MOUNTED FLUORESCENT FIXTURE

1’x4’ FLUORESCENT WALL MOUNTED FIXTURE

1’x4’ FLUORESCENT WALL MOUNTED FIXTURE WITH BATTERY PACK

COVE LIGHT FIXTURE WITH BATTERY PACK (TRIANGLE POINTS TO WASHED WALL)

COVE LIGHT FIXTURE (TRIANGLE POINTS TO WASHED WALL)

FLOODLIGHT FIXTURE

BATTERY PACK

600V, 30A, 3-POLE, IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF UON.

NON-FUSIBLE DISCONNECT SWITCH:

600V, 100AF/100AT, 3-POLE IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF UON.

ENCLOSED CIRCUIT BREAKER:

ENCLOSED MOTOR STARTER. SIZE 1 STARTER IN NEMA 1 ENCLOSURE UON.

NOTE:

SECONDARY UNDERGROUND ELECTRIC CABLE

PRIMARY OVERHEAD ELECTRIC CABLE

TRANSFORMER

EXISTING PRIMARY OVERHEAD ELECTRIC CABLE

LIGHT POLE

LIGHT BOLLARD

PULLBOX OR HANDHOLE:

GUY WIRE AND ANCHOR PIN

E-ELECTRICAL, C-COMMUNICATIONS, S-SECURITY, L-LIGHTING

NORMALLY CLOSED

NATIONAL ELECTRICAL CODE

NORMALLY OPEN

NON-REVERSING

MAIN CIRCUIT BREAKERMCB

NEUT

MH MANHOLE

AVAILABLE FAULT CURRENT

ATS AUTOMATIC TRANSFER SWITCH

NIC NOT IN CONTRACT

BB

BLDG BUILDING

BUILDING ENTRANCE FIBER PATCH PANEL

NTS NOT TO SCALE

BC

CCTV

CB

C

COND

CO

CONN

CONT

CMH

CKT

CONV

KCMIL

KVA

KVAR

KW

KWH

LRA

LSI

LTG

MAX

MCC

MCP

MDT

MEQ

MIN

MLO

MTG

N/C

NEC

NO

N/O

NR

P

OVHD

CONVENIENCE

CONTINUOUS

CONNECTION

CONDUCTOR

CONDUIT ONLY

NEUTRAL

BARE COPPER

MINIMUM

COMMUNICATIONS MAIN HOLE

CIRCUIT

CLOSED CIRCUIT TELEVISION

KILOWATT

COMM COMMUNICATION

BKR

BEPB

BREAKER

MAIN LUGS ONLY

MECHANICAL EQUIPMENT

MAIN DISTRIBUTION TERMINAL

MOTOR CIRCUIT PROTECTOR

MOTOR CONTROL CENTER

MAXIMUM

MOUNTING

LOW VOLTAGELV

LOCKED ROTOR AMPERE

KILOWATT HOUR

KILOVOLT AMPERES-REACTIVE

KILOVOLT AMPERES

KILOVOLT

THOUSAND CIRCULAR MILLS

KILOAMPERESKA

KV

NUMBER

ON CENTER, OVERCURRENT

OVERHEAD

OC

BUILDING BACKBONE

BUILDING ENTRANCE PROTECTION BLOCKS

CBB CAMPUS BACKBONE

BET BUILDING ENTRANCE TERMINAL

LSIG

LONG, SHORT, INSTANTANEOUS

LSI PLUS GROUND FAULT

BEFPP

PP POWER POLE

SMF SINGLE MODE FIBER

ESS ELECTRONIC SECURITY SYSTEM

RVSS REDUCE VOLTAGE SOLID STATE

TGB

TELECOMMUNICATIONS GROUNDING BUSBAR

CPU

CS

CR

CU

CT

DC

DDCP

DEM

DGP

DI

DIA

DISC

DPNL, DP

DM

DO

DPDT

DPST

DT

E.C.

EHC

EMT

ENCL

EHT

EWC

FAAP

FACP

FC

FDR

FLA

FLUOR

PABX

PBX

PCMS

PF

PH

POS

PT

PTZ

PVC

QY, QTY

REC

RECT

RFI

RGS

RMS

SCP

SP

S/S

ST

STD

STP

SW

SWBD

TB

TD

TELE

TERM

DEMAND

FIRE ALARM ANNUNCIATOR PANEL

CURRENT TRANSFORMER

COPPER

CENTRAL PROCESSING UNIT

CONTROL RELAY EXCHANGE

PRIVATE AUTOMATIC BRANCH

ETR

SHUNT TRIP

SS SOLID STATE

SPD SURGE PROTECTION DEVICE

GFGI

GFE GOVERNMENT FURNISHED EQUIPMENT

TMGB

HPP HORIZONTAL PATCH PANEL

BUSBAR

TELECOMMUNICATIONS MAIN GROUNDING FPP FIBER PATCH PANEL

GOVERNMENT INSTALLED

GOVERNMENT FURNISHED,

FUT

FV

GA

GFI

G, GND,

HAZ

HH

HOA

HP

HPF

HPS

HT

HV

HVAC

HZ

IC

IG

TT

TV

TVSS

TYP

V

VA

VM

VFD

W

WM

WP

XFMR

Y-D

Y

Z

UON UNLESS OTHERWISE NOTED

GROUND FAULT CIRCUIT INTERRUPTER TYPICAL

ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA

CONDITIONING

HEATING, VENTILATION AND AIR

SUPPRESSOR (ALSO SEE SPD)

TRANSIENT VOLTAGE SURGE

D1 b a

OS

J

J

T112

VFD

3CS

T30H

J

X

ES

PH

SEC

a,b

G

G

Gx

G

G

G

3/4"

#10, LCP

P

FM

T

J

CP

GFI

1APP

WAP

P

C

MOLDED CASE CIRCUIT BREAKER

TRANSFER SWITCH

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:5

:1

A M

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-001.dgn

JAVIER E. BIDOT & ASSOCIATES, P.S.C.

LAND SURVEYORS & CONSULTANTS

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

EMAIL: ROBERTPR22@GMAIL.COM

HUMACAO, P.R. 00791-6026

KEY NOTES

200A SW

150A FU

200H

200A

150A

3PH, 4W

480Y/277V, 250 AMPS

3PH, 4W

480Y/277V, 2,000 AMPS

3PH, 4W

480Y/277V, 1,200 AMPS

40Y

250Y

80Y

PANEL DPB1

STORAGE

UNIT

3PH, 4W

480Y/277V, 400 AMPS

G

200Y

PANEL MDPA

3PH, 4W

480Y/277V, 3,000 AMPS

2,000 AMP

BLDG.

TRAINING

PHYSICAL

SIMULATION/

BLDG

STORAGE

UNHEAT

WORKBAY/

45Y

3PH, 4W

480Y/277V, 800 AMPS

PANEL DPA1PANEL DPE1 PANEL DPC1PANEL DPD1

GENERAL NOTES

OLI NO.1 OLI NO.2

NO.2

OLI

BLDG

ADMIN

ATS1

BLDG

ADMIN

BLDG

CLASSROOM

ASSEMBLY HALL/

300S

A1

NTS

OVERALL ONE-LINE DIAGRAM & LOAD CALCULATIONS

(T-MDPA)

T-2500

TRANSFORMER

NEW

SWITCH

TRANSFER

AUTOMATIC

2,000 AMP

(58,130 AFC)

-480Y/277V

13.2 KV

2500 KVA

NO.1

OLI

OLI NO.3

DISTRIBUTION LINE

NEW OVERHEAD 13.2 KV

LSIG

200A200A

FUTURE USE.

STUB OUT 2-4" CONDUITS AND CAP 5’ FROM TRANSFORMER PAD FOR

CONTROL WIRING. REFER TO KEYNOTE 7.

PROVIDE 8#12, 1#12G IN 1"C FROM ATS TO GENERATOR FOR GENERATOR

IN BASE BID.

FEET OUTSIDE BUILDING FOR FUTURE GENERATOR FEEDER

PROVIDE CONDUITS WITH PULL STRING TO PULL BOX FIVE

REFER TO DWG E-006 FOR FURTHER INFORMATION.

REFER TO DWG E-005 FOR FURTHER INFORMATION.

REFER TO DWG E-004 FOR FURTHER INFORMATION.

REFER TO DWG E-003 FOR FURTHER INFORMATION.

FRONT.

AS INDICATED. TRANSFORMER TO BE LOOP FEED, DEAD

BREAK SWITCHES, AND LOAD BREAK DRAWOUT FUSES, SIZE

PAD MOUNTED TRANSFORMERS WITH, 15KV, LOAD

REFERENCE TO ES-408, 13.2 KV PLANS FOR ADDITIONAL INFORMATION.

BASIS OF DESIGN: GENERAL ELECTRIC.H.

SS = SOLID STATE ELECTRONIC TRIP TYPE BREAKER WHERE NOTED.

SOLID-STATE ELECTRONIC TRIP TYPE. REFER TO SPECIFICATIONS.

CIRCUIT BREAKER FRAME SIZES 225 AMP AND LARGER SHALL BE THE G.

E-006 FOR ADDITIONAL INFORMATION.

REFER TO SINGLE-LINE DIAGRAMS E-003, E-004, E-005 ANDF.

LINE SIDE.

EQUIPMENT SHALL BE THE SAME AS THAT SHOWN ON THE

CIRCUIT BREAKERS, AND CONTROL PANELS FEEDING

WIRE AND CONDUIT ON THE LOAD SIDE OF DISCONNECTS, E.

REFER TO DWG E-611 TO E-617 FOR PANELBOARD SCHEDULES.D.

REFER TO DWG E-602 FOR FEEDER SCHEDULE.C.

GENERATOR AND TRANSFORMERS.

REFER TO SITE PLAN, DWG ES-001 FOR LOCATION OFB.

INFORMATION ON 13.2 KV.

REFER TO 13.2 KV DESIGN PLANS FOR ADDITIONALA.

480Y/277V, 3 PH, 4 W

DIESEL GENERATOR

STANDBY

1,500 KW / 1,875 KVA

GEN1

L. PEREZ

AND LOAD CALCULATIONS

OVERALL ONE-LINE DIAGRAMS

E-002 c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:3

:1

P

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-002.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

1 3 6

2000/5

(3)CT

10Y 10Y

5 8

200Y

TELECOM ROOM

DATA LINE TO

TVSS

KEY NOTES

22Y

(15,866 AFC)

22Y

(21,485 AFC)

GND NEUTRAL

LIGHTNING PROTECTION PLAN FOR ADDITIONAL INFORMATION.

BOND TO LIGHTNING PROTECTION SYSTEM. REFERENCE

PLANS FOR LOCATION.

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER TO

PROVIDE A #3/0 COPPER GROUND WIRE TO GROUND BAR.

800AT

800AF

40S

225AT

250AF

225AT

250AF

100AT

100AF

175AT

250AF

100AT

100AF

125AT

250AF

100AT

100AF

25S

(25,219 AFC)

80Y

10Y

STOR

UNIT

(200A)

200A

ELEVATOR

2 3 4

M

3000/5

(3)CT

45Y

7 8

300S

9 10

TELECOM ROOM

DATA LINE TO

TVSS

200Y

G

GND NEUTRAL

225AT

250AF

250AT

400AF

SPARE

2000AT

2000AF

EPM

SPACE

250A

SPACE

250A

SPACE

250A

SPACE

250A

EPM

2000AT

2000AF

3000AT

3000AF

200AT

250AF

SPECIFICATIONS.

PROVIDE ELECTRONIC POWER METER (EPM). REFER TO

250Y

1200AT

1200AF

400AT

400AF

(16,917 AFC)

40Y

100% RATED

TRAIN

SIM

MAINT

WORKBAY

C1

A1

10Y

(30,093 AFC)

100AT

100AF

125AT

250AF

25S

10Y

(13,699 AFC)

100AT

100AF

22Y

(38,119 AFC)

225AT

250AF

480Y/277V, 3 PH, 4 W

DIESEL GENERATOR

STANDBY

1,500 KW/1,875 KVA

GEN1

22Y

(19,351 AFC)

225AT

250AF

GENERAL NOTES

OLI NO.1

LPA3

PANEL

PPA2

PANEL

RPA2

PANEL

LPA2

PANEL

PPA1

PANEL

SLA1

PANEL

LPA1

PANEL

DPB1

PANEL

DPD1

PANEL

DPE1

PANEL

208/120V 480 -

(75 KVA)

T-RPA3

T75

PPA3

PANEL

LPA4

PANEL

PPA4

PANEL

RPA3

PANEL

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO BUILDING STRUCTURAL STEEL.

(175A)

200A

RPA3A

PANEL

208/120V 480 -

(75 KVA)

T-RPA1

T75

(125A)

200A

22Y

RPA1A

PANEL

22Y

RPA2A

PANEL

22Y

208/120V 480 -

(112.5 KVA)

T-RPA2T112

175AT

250AF

(175A)

200A

RPA4A

PANEL

22Y

40S

208/120V 480 -

(112.5 KVA)

T112 T-RPA4

RPA4

PANEL

100AT

100AF

(70A)

100A

208/120V 480 -

(45 KVA)

T-RPBE1

T45

RPBE1

PANEL

BLDG

STORAGE

UNIT

NO SCALE

NO SCALE

GND BAR

ADMINISTRATION BUILDING ONE-LINE DIAGRAM (MDPA)

ADMINISTRATION BUILDING ONE-LINE DIAGRAM (DPA1)

ONE-LINE DIAGRAMS AND LOAD CALCULATIONS

ADMINISTRATION BUILDING

E-003

FOR ADDITIONAL INFORMATION

REFER TO MECHANICAL EQUIPMENT SCHEDULE ON E-602

200Y

(8,423 AFC)

SW-RPBE1

SW-RPA4SW-RPA3SW-RPA2

(12,694 AFC)

(49,678 AFC)

(7,057 AFC)

(5,866 AFC)

18 19

SPACE

250 AMP

SPACE

250 AMP

40AT

100AF

208/120V 480 -

(15 KVA)

T-RPFD

T15

RPFD

PANEL

STATION

FUEL DISP

AFC)

(1,246

GEN1

PANEL

(4,371 AFC)

GENERATOR

DPA1, 2000A, 480Y/277V, 3 PHASE, 4 WIRE, 65KAIC, (49,675 AFC)

9 NEC 250.52.A.3. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO CONCRETE-ENCASED ELECTRODE PER

ROUTE TO FIRE ALARM CONTROL. COORDINATE WITH FIRE ALARM PLANS.

PROVIDE 3 #12, 3/4" C, CIRCUIT 21, RPA1A, FOR SHUNT-TRIP OF ELEVATOR.

AS REQUIRED TO A 3/4" X 10’ COPPER GROUND ROD.

PROVIDE #3/0 COPPER GROUND CONDUCTOR IN 3/4" CONDUIT

ADDITIONAL INFORMATION

DWG E-005 FOR

REFERENCE

PANEL DPC1

CLASSROOM/ASSEMBLY

TO

TS1

N1 N1 N1

9.1

9Y

(2,707AFC)

RPF1

PANEL

BLDG

CWHF

RPA1

PANEL

(34,804 AFC) (39,796 AFC)

(872 AFC)

TO PLANS FOR LOCATION.

BAR. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER

PROVIDE A #3/0 COPPER BOND TO TELECOM ROOM GROUND

450AT

600AF

450FU

600SW

N4X

TVSS

2 15

FOR ADDITIONAL INFORMATION

SEE DWG E-002

DWG E-004

REFERENCE

DWG E-006

REFERENCE

OLI NO.2

OLI NO.3

ATS1

TRANSFER SWITCH,

AUTOMATIC

3 PHASE, 4 POLE

2,000 AMP, 480 V

E-002

ON DWG

KEYNOTE 7

REFER TO

OLI NO.3

120V

480/

120V

480/

SYSTEM, IF AVAILABLE.

PROVIDE A #3/0 BOND TO NEAREST COLD WATER PIPE

LSIG, SS

100% RATED

LSIG, SS

100% RATED 100% RATED

SS

SS SS

SS SS SS

LSIG, SS

100% RATED SS SS SS SS SS SS

LSIG, SS

100% RATED

LSI, SS

BKR, SS

SHUNT TRIP

GEN. NOTE F

REFER TO

MDPA, 3000A, 480Y/277V, 3 PHASE, 4 WIRE, 65KAIC, (50,470 AFC)

LSIG, SS

100% RATED

2,000 AMP

(9,644 AFC)

REFERENCE SPECIFICATION 260573 FOR ADDITIONAL INFORMATION.

AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC-110.24(A). ALSO

MAIN SERVICE DISCONNECT SHALL BE FIELD MARKED WITH THE MAXIMUM

(19,409 AFC)

(34,804 AFC)

(5,270 AFC)

(41,375 AFC)

(6,621 AFC)

(19,033 AFC)

(7,257 AFC)

(8,478 AFC)

(5,188 AFC)

(6,544 AFC)

(26,549 AFC)

(17,611 AFC)

(7,197 AFC)

(3,512 AFC)

17S

90AT

100AF

208/120V 480 -

(30 KVA)

T-GEN1

T30

AFC)

(7,326

CH-1

NO.

CHILLER

BASIS OF DESIGN: GENERAL ELECTRIC.G .

ELECTRICAL EQUIPMENT PRIOR TO COMMENCING WORK.

DRAWINGS FOR ACTUAL REQUIREMENTS FOR INSTALLATION OF ALL

CONTRACTOR SHALL COORDINATE WITH MANUFACTURER’S SHOPF.

SS = SOLID STATE ELECTRONIC TRIP TYPE BREAKER WHERE NOTED.

SOLID-STATE ELECTRONIC TRIP TYPE. REFER TO SPECIFICATIONS.

CIRCUIT BREAKER FRAME SIZES 225 AMP AND LARGER SHALL BE THE E.

BREAKERS AND SPACES SHOWN ON ONE-LINE ARE 3 POLE, UON.D.

THE LINE SIDE, UON.

EQUIPMENT SHALL BE THE SAME AS THAT SHOWN ON

CIRCUIT BREAKERS, AND CONTROL PANELS FEEDING

WIRE AND CONDUIT ON THE LOAD SIDE OF DISCONNECTS, C.

PANELBOARD SCHEDULES.

REFER TO DWG E-611, E-612, E-613 AND E-614 FORB.

REFER TO DWG E-602 FOR FEEDER SCHEDULE.A.

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:3

:2

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-003.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

TVSS

1 2 3 4

M

800/5

(3)CT

6 7 8 9

GND NEUTRAL

GND BAR

10Y

80Y

120V

480/

800AT

800AF

TELECOM ROOM

DATA LINE TO

3/4"C WITH

P-2A

PUMP

P-2B

PUMP

VFD VFD

250AT

400AF

25S

20 25

AHU-21 AHU-22

60AT

100AF

70AT

100AF

30AT

100AF

30AT

100AF

150AT

250AF

100AT

100AF

125AT

250AF

EPM

KEY NOTES

LIGHTNING PROTECTION PLAN FOR ADDITIONAL INFORMATION.

BOND TO LIGHTNING PROTECTION SYSTEM. REFERENCE

PLANS FOR LOCATION.

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER TO

PROVIDE A #3/0 COPPER GROUND WIRE TO GROUND BAR.

SPECIFICATIONS.

PROVIDE ELECTRONIC POWER METER (EPM). REFER TO

11 12

GENERAL NOTES

A1

NTS

208/120V 480 -

(75 KVA)

T-RPB1

T75

RPB1

PANEL

LPB1

PANEL

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO BUILDING STRUCTURAL STEEL.

ONE-LINE DIAGRAM AND LOAD CALCULATIONS

UNIT STORAGE BUILDING

E-004

FOR FURTHER INFORMATION.

INTEGRAL TRANSFORMER/PANELBOARD. SEE SCHEDULES

PPB1

PANEL

250FU

400SW

VFD VFD

10 10

FOR ADDITIONAL INFORMATION.

REFER TO MECHANICAL EQUIPMENT SCHEDULE ON E-602

9 9 9 9

TVSS

9 9

100AT

100AF

(4,858 AFC) (8,240 AFC) (3,985 AFC) (4,231 AFC)

SPARE

15Y

DPB1, 800A, 480Y/277V, 3 PHASE, 4 WIRE, 25KAIC, 25,119 AFC

NEC 250.52.A.3. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO CONCRETE-ENCASED ELECTRODE PER.

N4X

UNIT STORAGE BUILDING ONE-LINE DIAGRAM (DPB1)

TO PLANS FOR LOCATION.

BAR. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER

PROVIDE A #3/0 COPPER BOND TO TELECOM ROOM GROUND

AS REQUIRED TO A 3/4" X 10’ COPPER GROUND ROD.

PROVIDE #3/0 COPPER GROUND CONDUCTOR IN 3/4" CONDUIT

FOR ADDITIONAL INFORMATION

SEE DWG E-003

SYSTEM, IF AVAILABLE.

PROVIDE A #3/0 BOND TO NEAREST COLD WATER PIPE

LSI, SS

100% RATED

SSSS

SPACE

250A

SPACE

250A

SPACE

250A

SS

BASIS OF DESIGN: GENERAL ELECTRIC.G.

ELECTRICAL EQUIPMENT PRIOR TO COMMENCING WORK.

DRAWINGS FOR ACTUAL REQUIREMENTS FOR INSTALLATION OF ALL

CONTRACTOR SHALL COORDINATE WITH MANUFACTURER’S SHOPF.

SOLID-STATE ELECTRONIC TRIP TYPE. REFER TO SPECIFICATIONS.

CIRCUIT BREAKER FRAME SIZES 225 AMP AND LARGER SHALL BE THE E.

BREAKERS AND SPACES SHOWN ON ONE-LINE ARE 3 POLE, UON.D.

THE LINE SIDE, UON.

EQUIPMENT SHALL BE THE SAME AS THAT SHOWN ON

CIRCUIT BREAKERS, AND CONTROL PANELS FEEDING

WIRE AND CONDUIT ON THE LOAD SIDE OF DISCONNECTS, C.

REFER TO DWG E-614 FOR PANELBOARD SCHEDULES.B.

REFER TO DWG E-602 FOR FEEDER SCHEDULE.A.

(24,495 AFC)

(10,921 AFC)

(22,909 AFC)

(15,965 AFC) (12,501 AFC)

REFERENCE SPECIFICATION 260573 FOR ADDITIONAL INFORMATION.

AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC-110.24(A). ALSO

MAIN SERVICE DISCONNECT SHALL BE FIELD MARKED WITH THE MAXIMUM 11

CH-2

NO.

CHILLER

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:3

:4

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-004.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

1 2 3 4 5 6

10Y

7 8

250Y

9 10

TVSS

22Y

(21,278 AFC)

GND NEUTRAL

GND BAR

25S

25S

100AT

150AF

100AT

150AF

125AT

250AF

125AT

250AF

125AT

250AF

60AT

100AF

225AT

250AF

KEY NOTES

LIGHTNING PROTECTION PLAN FOR ADDITIONAL INFORMATION.

BOND TO LIGHTNING PROTECTION SYSTEM. REFERENCE

SPECIFICATIONS.

PROVIDE ELECTRONIC POWER METER (EPM). REFER TO

250AT

250AF

60S

GENERAL NOTES

A1

NTS

600FU

600SW

60S

PLANS FOR LOCATION.

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER TO

PROVIDE A #3/0 COPPER GROUND WIRE TO GROUND BAR.

K1

PANEL

PPC1

PANEL

208/120V 480 -

(75 KVA)

T-RPC2

T75

RPC2

PANEL

RPC1

PANEL

LPC1

PANEL

FOUR-WIRE SOLID NEUTRAL 208/120 VOLT, AC.

PROVIDE FUSIBLE, HEAVY DUTY DISCONNECT SWITCH,

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO BUILDING STRUCTURAL STEEL.

CLASSROOM ASSEMBLY BUILDING ONE-LINE DIAGRAM (DPC1)

10Y

RPC3

PANEL

60Y

K3

PANEL

208/120V 480 -

T-K1 (150 KVA)

T150

N1

K1

500FU

600SW

500AT

600AF

125FU

200SW

1200AT

1200AF

VFD 2

AHU-32

12 13

45AT

100AF

VFD 2

45AT

100AF

VFD 2

P-3A

PUMP

P-3B

PUMP

ADDITIONAL INFORMATION.

REFER TO MECHANICAL EQUIPMENT SCHEDULE ON E-602 FOR

9 9

(6,526 AFC)

(15,760 AFC) (21,121 AFC)

50AT

100AF

RPHP

PANEL

(2,785 AFC)

AFC)

(3,308

LOCATION

HELIPAD

AS REQUIRED TO A 3/4" X 10’ COPPER GROUND ROD.

PROVIDE #3/0 COPPER GROUND CONDUCTOR IN 3/4" CONDUIT

NEC 250.52.A.3. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO CONCRETE-ENCASED ELECTRODE PER.

M

1200/5

(3)CT

120V

480/

EPM

TELECOM ROOM

DATA LINE TO

DPC1, 1,200A, 480Y/277V, 3 PHASE, 4 WIRE, 35KAIC, (29,399 AFC)

SPARE

208/120V 480 -

(75 KVA)

T-RPC1

T75

(3,971 AFC) (3,971 AFC)

N4X

TVSS

TO PLANS FOR LOCATION.

BAR. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER

PROVIDE A #3/0 COPPER BOND TO TELECOM ROOM GROUND

10Y

RPC4

PANEL

FOR ADDITIONAL INFORMATION

SEE DWG E-003

OLI NO.5

240/120V 480 -

8 - 1P PANEL

WITH INTERGRAL

SERVICE CENTER

SINGLE PHASE

(10 KVA)

T-RPHP

T15

250AT

250AF

60S

600FU

600SW

60S

208/120V 480 -

T-K2 (150 KVA)

T150

N1

K2

K2

PANEL

SYSTEM, IF AVAILABLE.

PROVIDE A #3/0 BOND TO NEAREST COLD WATER PIPE

LSIG, SS

100% RATED

SS SS SS SS SS SS LSI, SS

DRAWINGS FOR ACTUAL REQUIREMENTS FOR INSTALLATION OF ALL

CONTRACTOR SHALL COORDINATE WITH MANUFACTURER’S SHOPF.

SS = SOLID STATE ELECTRONIC TRIP TYPE BREAKER WHERE NOTED.

CIRCUIT BREAKER FRAME SIZES 225 AMP AND LARGER SHALL BE THE E.

BREAKERS AND SPACES SHOWN ON ONE-LINE ARE 3 POLE, UON.D.

THE LINE SIDE, UON.

EQUIPMENT SHALL BE THE SAME AS THAT SHOWN ON

CIRCUIT BREAKERS, AND CONTROL PANELS FEEDING

WIRE AND CONDUIT ON THE LOAD SIDE OF DISCONNECTS, C.

REFER TO DWG E-615 AND E-616 FOR PANELBOARD SCHEDULES.B.

REFER TO DWG E-602 FOR FEEDER SCHEDULE.A.

REFERENCE SPECIFICATION 260573 FOR ADDITIONAL INFORMATION.

AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC-110.24(A). ALSO

MAIN SERVICE DISCONNECT SHALL BE FIELD MARKED WITH THE MAXIMUM 11

(14,223 AFC)

(5,054 AFC)

(6,715 AFC)

(5,124 AFC)

(6,777 AFC)

(9,422 AFC)

(22,488 AFC) (22,488 AFC)

(5,602 AFC) (4,313 AFC)

(5,585 AFC)

(16,115 AFC)

14 15

SPACE

CH-3

NO.

CHILLER

DWH-3

NO.

HEATER

WATER

ONE-LINE DIAGRAMS AND LOAD CALCULATIONS

CLASSROOM ASSEMBLY BUILDING

E-005 c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:3

:5

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-005.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

M

400/5

(3)CT

6 7 8 9

400/5

(3)CT

GND NEUTRAL

GND NEUTRAL

GND BAR

GND BAR

10Y

10Y

40Y

45Y

7 8 9 10 11 12

( 17,442 AFC)

120V

480/

120V

480/

400 AT

400 AF

250AT

400AF

100AT

100AF

15AT

100AF

15AT

100AF

P-5A

PUMP

20AT

100AF

P-5B

PUMP

70AT

100AF

70FU

100SW

30AT

100AF

20AT

100AF

20AT

100AF

TELECOM ROOM

DATA LINE TO

3/4"C WITH

TELECOM ROOM

DATA LINE TO

3/4"C WITH

( 10,018 AFC)

7.5

125FU

200SW

VFD VFD

125AT

250AF

40S

15 7.5

AHU 41 AHU 42

45AT

100AF

25AT

100AF

25AT

100AF

25AT

100AF

100AT

100AF

100AT

100AF

175AT

250AF

VFD

AHU-51

27S

EPM

EPM

LIGHTNING PROTECTION PLAN FOR ADDITIONAL INFORMATION.

BOND TO LIGHTNING PROTECTION SYSTEM. REFERENCE

PLANS FOR LOCATION.

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER TO

PROVIDE A #3/0 COPPER GROUND WIRE TO GROUND BAR.

SPECIFICATIONS.

PROVIDE ELECTRONIC POWER METER (EPM). REFER TO

E-006

D. MONAHAN

M. CAHILL

C1

NTS

A1

NTS

SIMULATION CENTER / PHYSICAL TRAINING BUILDING ONE-LINE DIAGRAM (DPD1) - OLI NO.2

LPD1

PANEL

RPD1

PANEL

208/120V 480 -

(75 KVA)

T-RPE1

T75

LPE1

PANEL

RPE1

PANEL

MAINTENANCE TRAINING WORKBAY BUILDING ONE-LINE DIAGRAM (DPE1) - OLI NO.1

RPD2

PANEL

10Y

PPD1

PANEL

22Y

7.5

P-4A

PUMP

P-4B

PUMP

8 8 VFD8 VFD8

TVSS

208/120V 480 -

(112.5 KVA)

T-RPD1

T112

8 8

8 8 8

8 8

N4X

125AT

250AF

N1

15FU

30SW

N18 VFD8 VFD8

8 8

8 8 8 8 8

8 8

TVSS

(9,983 AFC)

(3,747 AFC)

(5,710 AFC) (3,407 AFC) (5,028 AFC) (1,869 AFC) (5,028 AFC)

(9,704 AFC)

(5,058 AFC) (4,576 AFC)

( 16,135 AFC)

(9,812 AFC)

(6,742 AFC) (4,576 AFC)

VAV-507

AS REQUIRED TO A 3/4" X 10’ COPPER GROUND ROD.

PROVIDE #3/0 COPPER GROUND CONDUCTOR IN 3/4" CONDUIT

REFER TO MANUFACTURER’S SHOP DRAWINGS FOR ADDITIONAL INFO.

INCLUDE ALL CONDUIT AND WIRING FOR A COMPLETE INSTALLATION.

SHALL INCLUDE THE INSTALLATION OF PUSH BUTTON CONTROLS.

ELECTRICAL INSTALLATION FOR MOTORIZED OVERHEAD DOORS

DPE1, 250A, 480Y/277V, 3 PHASE, 4 WIRE, 35K AIC, 9,644 AFC

N4X

20AT

100AF

SPARE

(2,959 AFC)

N1

ROLLUP DOORS

WORKBAY

N1

6FU

30SW

6FU

30SW

DWH-5

TO PLANS FOR LOCATION.

BAR. INSTALL IN 3/4" PVC CONDUIT AS REQUIRED. REFER

PROVIDE A #3/0 COPPER BOND TO TELECOM ROOM GROUND

10Y

RPE1A

PANEL

FOR ADDITIONAL INFORMATION

SEE DWG E-003

FOR ADDITIONAL INFORMATION

SEE DWG E-003

SYSTEM, IF AVAILABLE.

PROVIDE A #3/0 BOND TO NEAREST COLD WATER PIPE

INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO BUILDING STRUCTURAL STEEL.

SS

SS SS SPACE

100A

SPACE

100A

GENERAL NOTES (CONTINUED)

DRAWINGS FOR ACTUAL REQUIREMENTS FOR INSTALLATION OF ALL

CONTRACTOR SHALL COORDINATE WITH MANUFACTURER’S SHOPF.

CIRCUIT BREAKER FRAME SIZES 225 AMP AND LARGER SHALL BE THE E.

SS

SS SPACE

100A

SPACE

100A

BREAKERS AND SPACES SHOWN ON ONE-LINE ARE 3 POLE, UON.D.

THE SAME AS THAT SHOWN ON THE LINE SIDE, UON.

BREAKERS, AND CONTROL PANELS FEEDING EQUIPMENT SHALL BE

WIRE AND CONDUIT ON THE LOAD SIDE OF DISCONNECTS, CIRCUITC.

REFER TO DWG E-617 FOR PANELBOARD SCHEDULES.B.

REFER TO DWG E-602 FOR FEEDER SCHEDULE.A.

KEY NOTES

REFERENCE SPECIFICATION 260573 FOR ADDITIONAL INFORMATION.

AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC-110.24(A). ALSO

MAIN SERVICE DISCONNECT SHALL BE FIELD MARKED WITH THE MAXIMUM11

( 6,373 AFC)

( 6,905 AFC)

(15,786 AFC)

DPD1, 400A, 480Y/277V, 3 PHASE, 4 WIRE, 35K AIC, 16,917 AFC

NEC 250.52.(A)(3). INSTALL IN 3/4" PVC CONDUIT AS REQUIRED.

PROVIDE A #3/0 BOND TO CONCRETE-ENCASED ELECTRODE PER.

( 4,000 AFC)

( 4,478 AFC)

13 14

SPACE

100A

SPACE

100A

OLI NO.1 AND NO.2

ONE-LINE DIAGRAMS AND LOAD CALCULATIONS

MAINTENANCE TRAINING WORKBAY BUILDING

SIMULATION CENTER / PHYSICAL TRAINING BUILDING AND

CU-4

NO.

CHILLER

CH-5

NO.

CHILLER

15FU

30SW

REFER TO MECHANICAL LOAD SUMMARY ON E-602 FOR ADDITIONAL INFO.

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E

.d g n

:3

:0

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-E-006.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

READINESS CENTER (RC)

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-ES-001.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

MICHAEL J. CAHILL, PE

FL REGISTRATION: #PE43673

EXP. 02/28/13

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

EMAIL: ROBERTPR22@GMAIL.COM

HUMACAO, P.R. 00791-6026

STA-1819-5

CO

N

A.

B.

C.

D.

E.

T1

T1

T1

T1

2T1

2T1

2T1

2T1

2T1

250Y

80Y

40Y

45Y

80Y

45Y

40Y

45Y

45Y

GENERAL NOTES KEY NOTES

OLI NO.1

OLI NO.2

40’ 20’ 0 40’

ET-502

A1

ET-502

D4

ET-503

A1

ET-503

A3

T1

T1

T1

T1

TRANSFORMER

T-2500 (T-MDPA)

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

T1

2T1

T1

SLA1-15

SLA1-15

SLA1-15

SLA1-15

SLA1-15

SLA1-15

SLA1-17

SLA1-17

SLA1-17

SLA1-17

SLA1-17

SLA1-17

SLA1-17

SLA1-17

SLA1-15

SLA1-16

SLA1-16

SLA1-16

SLA1-16

SLA1-16

SLA1-16

SLA1-18

SLA1-18

SLA1-18

SLA1-18

SLA1-18

SLA1-18

SLA1-18

SLA1-18

SLA1-13

SLA1-13

SLA1-13

SLA1-13

SLA1-

SLA1-13

SLA1-13

SLA1-13

SLA1-13

SLA1-14

SLA1-18

SLA1-18

SLA1- 14

SLA1- 14

SLA1- 14

SLA1- 14

SLA1- 14

SLA1- 14

SLA1- 14

4 4

SLA1-2,4,6

SLA1-1,3,5

WP/GFI

WP/GFI

WP/GFI

WP/GFI

SLA1-13,15,17

SLA1- 14,16,18

RPFD

WP/GFI

RPFD-6

RPC3-18

E-502

A5

E-502

A5

TYP

TYP

DPA1-18

DPA1-17

RPC3-20

RPD1-22

RPE1-39

RPFD-3

E-503

A2

RPFD-4

THH3

ET-503

D3

ET-505

A1

ET-503

A5

THH2

ET-503

D4

ET-503

D3

ET-503

A5ET-503

B4

ET-503

B5

ET-503

D4

THH1

ET-505

A1

ET-503

A5

ET-503

A5

ET-503

D3

ET-503

D3

C u

C u

TMH2

12" X 18" TELECOMMUNICATIONS HAND HOLE (THH).

ONE 2-INCH SCH40 PVC FOR CATV. STUB-OUT 5’ BEYOND

BUILDING FOUNDATION.

ET-503

D4

ET-503

D4

ET-503

A5

RPA1A

CKT-29

(GEN1-7

OLI 3)

1#10, 1#10N, 1#10G, 1"C

1#10, 1#10N, 1#10G, 1"C

PROVIDE CIRCUIT TO SIGN INCLUDE NEMA 4X DISCONNECT.

COORDINATE ELECTRICAL REQUIREMENTS WITH SIGN

MANUFACTURER.

EXTERIOR UNDERGROUND PORTION OF DUCTBACK SHALL BE

INSTALLED WITH CONCRETE CAP. REFER TO TYPICAL DUCTBANK

DETAILS ON E-502.

REFER TO TYPICAL DUCTBANK INSTALLATION DETAIL A2

ON E-502.

200H

200H

300S

MAIN ELECTRICAL / TELECOMMUNICATION

SITE PLAN

ES-001

REFER TO POWER PLANS FOR CONTINUATION TO ELECTRICAL

ROOM.

REFER TO TELECOMMUNICATION PLANS FOR CONTINUATION TO

TELECOM ROOM.

ALL POLE MOUNTED SITE LIGHTING FIXTURES ARE

TYPE T1, UNLESS NOTED OTHERWISE.

ALL BOLLARDS ARE TYPE S, UNLESS NOTED

OTHERWISE, REFER TO DETAIL B4 ON E-503

FOR ADDITIONAL INFORMATION.

REFER TO BUILDING LIGHTING PLAN SHEETS FOR

BUILDING MOUNTED LIGHTING FIXTURES.

REFER TO E-601 FOR LIGHTING FIXTURE SCHEDULE.

REFER TO ONE-LINE DIAGRAMS ON SHEETS E-002,

E-003, E-004 AND E-005 FOR ADDITIONAL

INFORMATION.

7 7

SLA1-7

E-502

A5

OLI NO.5

RPA1A-27

(GEN1-16

OLI NO.3)

OLI NO.3

GEN1

1500 KW

GENERATOR

NEW 13.2 KV

RISER POLE

ROUTE CONDUIT & CONDUCTORS UP RISER POLE. REFER TO

ES-408 FOR ADDITIONAL INFORMATION.

PROVIDE FAA L-806 WIND CONE STYLE 1, SIZE 1 (8FT) WITH

RED LED OBSTRUCTION LIGHT AND 4-120W PAR 38 HALOGEN

FLOODLIGHTS AT 90 DEGREES INTERVALS.

PROVIDE HELIPAD LIGHT FIXTURE FAA L-852E YELLOW, OMNI

DIRECTIONAL, 45W 6.6A WITH ISOLATION TRANSFORMER AND

MOUNTING BASE L-868B.

20’ 10’ 0 20’

RPHP-2

2#12, 1#12G, 3/4"C

E-502

A5

RPHP-4

WP/GFI

T-RPHP

RPHP

12’-2 3/8"TYP

13131

3 3

1 1

3 3

13131

RPHP-1,3

2#12, 2#12N, 1#12G, 3/4"C

RPHP-4

2#12, 1#12G, 3/4"C

D1

9Y 9Y

9Y

MOUNT PANEL/DISCONNECTS AND WEATHER-PROOF GFCI

RECEPTACLE WITH IN-USE COVER TO EQUIPMENT RACK. SEE

DETAIL A5, E-502.

3#10, 3#10N, 1#10 G, 1"C CKTS 1,3,5 TO PANEL SLA1, ADMIN

MAIN ELEC ROOM VIA ASTRONOMIC TIME CLOCK TS-1.

3#10, 3#10N, 1#10 G, 1"C CKTS 2,4,6 TO PANEL SLA1, ADMIN

MAIN ELEC ROOM VIA ASTRONOMIC TIME CLOCK TS-1.

REFER TO MECHANICAL LOAD SUMMARY ON E-602.

PROVIDE 1" CONDUIT FOR SECURITY GATE KEYPAD CONTROLS.

PROVIDE 2" CONDUIT TO THH1.

PROVIDE 2" CONDUIT TO THH2.

T1 T1

T1

PROVIDE L-854 AIR TO GROUND AM RADIO RECEIVER/DECODER

FAA TYPE 1, STYLE 1 WITH WHIP ANTENNA. LIGHT CONTROLLER

TO OPERATE WITND CONE AND HELIPAD PERIMETER LIGHTS.

PROVIDE GROUND ROD, REFER TO SPECIFICATIONS FOR SIZE.

#8G

#8G

PROVIDE ONE SPARE CONDUIT OF THE SAME SIZE OF THE

LARGEST FEEDER CONDUIT.

DPC1-12

2#4/0, 1#4, 2"C

1-2" SPARE C

REFER TO DETAIL A1/E-161 FOR CONTINUATION TO ELECTRICAL

PANEL RPF1 AT CONTROLLED WASTE HANDLING FACILITY.

MH

MH

MH

(TYP)

HH

MH

MH

PB

PB

PB

PB

PB

PB

HHHH

HHHH

PB

MH

MH

MH

HH

GEN1

-9

TELE/COMM MANHOLE OR HANDHOLE.

TELE/COMM DUCT BANK.

TWO 2 INCH SCH40 CONDUITS.

BASE BID TO SUPPLY CONDUIT AND PULL BOX ONLY FOR

EMERGENCY GENERATOR OLI NO. 3. REFER TO ONE-LINE FOR

ADDITIONAL INFORMATION.

3#6, 3#6N, 1#8G, 1 1/4" C CKTS 13,15,17 TO PANEL SLA1, ADMIN

MAIN ELEC ROOM VIA ASTRONOMIC TIME CLOCK TS-1.

3#6, 3#6N, 1#8G, 1 1/4" C CKTS 14,16,18 TO PANEL SLA1, ADMIN

MAIN ELEC ROOM VIA ASTRONOMIC TIME CLOCK TS-1 FOR CKT 14,

AND ASTRONOMIC TIME CLOCK TS-2 FOR CKTS 16 AND 18.

INTEGRAL TRANSFORMER AND PANELBOARD REFER TO ONE LINE

FOR ADDITIONAL INFORMATION.

F. REFER TO CONDUIT SCHEDULE ON DWG E-602 FOR

QUANTITIES AND SIZES.

G. REFER TO HIGH VOLTAGE PLANS, ES-407 & ES-408

FOR ADDITIONAL INFORMATION.

H. REFER TO TELECOMMUNICATION CONDUIT

SCHEDULE ON DWG ET-503 FOR ADDITIONAL

INFORMATION FOR COMMUNICATION CONDUITS.

I. ALL UNDERGROUND CONDUITS, ACTIVE OR EMPTY,

SHALL BE EQUIPPED WITH DETECTABLE PULL TAPE.

J. COORDINATE ROUTING OF CONDUITS BENEATH WALL

FOOTINGS. AVOID ROUTING CONDUITS IN AREA OF

COLUMN FOOTINGS. SEE STRUCTURAL FOR ADDITIONAL

INFORMATION.

SLA1-5

KEY NOTES (CONTINUED)

PB

K. REFER TO SITE/CIVIL UTILITY LAYOUT PLAN FOR

EXACT LOCATIONS OF ELECTRICAL MANHOLES,

GENERATOR, LIGHT POLE BASES, TRANSFORMERS,

AND EXACT ROUTING OF ELECTRICAL DUCT BANKS.

L. REFER TO DWG E-001 FOR ELECTRICAL AND TELECOM

SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.

M. PROVIDE A MINIMUM #10 THWN-2 CONDUCTORS FOR

EXTERIOR CIRCUITS, UON.

N. FOR ELECTRICAL POWER PULL BOX SIZES (UON):

HH - REFER TO DETAIL A1/E-503.

PB - REFER TO DETAIL D5/E-503.

MH - REFER TO DETAIL D2/E-503

VEHICLE WASH

STATION

OLI NO.4

THH4

THE CONTRACTOR SHALL PROVIDE A GROUNDING RING SYSTEM

FOR THE WATER STORAGE TANKS AND PUMP HOUSE. CONTRACTOR

SHALL VERIFY SITE CONDITIONS AND DIMENSIONS AND PROVIDE

A # 3/0 BARE COPPER GROUND LOOP AROUND THE PERIMETER OF

THE TANKS AND PUMP HOUSE WITH A GROUND ROD EVERY 100

FEET. ONE GROUND ROD SHALL HAVE AN ACCESS WELL PER DETAIL

A2 / E-501. GROUNDING AND BONDING SHALL BE IN ACCORDANCE

WITH THE NEC AND DIVISION 26 SPECIFICATIONS. THE LIGHTNING

PROTECTION AND ELECTRICAL POWER TO THE PUMP HOUSE SHALL

BE BONDED TO THE GROUND RING. INSTALL PVC CONDUIT TO

PROTECT GROUND WIRE AS REQUIRED. ALL GROUNDS SHALL BE

PROPERLY SUPPORTED AND CONCEALED WHENEVER POSSIBLE.

COORDINATE GROUND ROD LOCATIONS WITH LOCATIONS OF

LIGHTNING PROTECTION DOWN CONDUCTORS.

CONTRACTOR SHALL COORDINATE WITH PUMP MANUFACTURER’S

SHOP DRAWINGS FOR ACTUAL REQUIREMENTS FOR INSTALLATION

OF ALL ELECTRICAL EQUIPMENT PRIOR TO COMMENCING WORK.

STUB-UP 2-INCH COMM CONDUITS ON INSIDE WALL OF PUMP

HOUSE. COORDINATE LOCATION WITH OTHER UTILITIES. SEE

ET-601 FOR CABLE ROUTING.

FOR CONTINUATION

SEE DWG ES-002

LIGHT FIXTURE FF

TYP OF 4

COORDINATE WITH

FLAG POLE

INSTALLATION

D1

HELIPAD PLAN- OLI NO.5

MAIN ELECTRICAL /

TELECOMMUNICATION SITE PLAN

ET-503

B4

ET-503

B5

PROVIDE 3# 2, 1# 2 N, 1# 8 G IN 2" PVC SCH40 FROM PANEL

RPBE1-CKT 31:33:35, TO ELECTRICAL PANEL IN FIRE PUMP HOUSE.

PANEL FURNISHED BY FIRE PUMP HOUSE MANUFACTURER.

CONTRACTOR SHALL PROVIDE A SPD AT THE LINE SIDE OF THE

ELECTRICAL PANEL. PROVIDE 2" PVC SCH40 SPARE TO PULL BOX.

ALSO REFER TO NOTE 31 AND 34.

PROVIDE 8-#14, 1 #14 G IN 1" PVC SCH40 FROM FIRE PUMP

CONTROLLER TO TANK LEVELS ON EACH TANK. PROVIDE

HAND HOLE AT BASE OF TANK. SEE DETAIL A1/E-503.

ALSO REFER TO NOTE 31 AND 34.

REFER TO FIRE PROTECTION PLANS AND DIV. 21 SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

THE CONTRACTOR SHALL PROVIDE A LIGHTNING PROTECTION

SYSTEM FOR THE WATER STORAGE TANKS AND PUMP HOUSE.

CONTRACTOR SHALL VERIFY SITE CONDITIONS AND DIMENSIONS

AND PROVIDE A LIGHTNING PROTECTION SYSTEM THAT COMPLIES

WITH NFPA 780 REQUIREMENTS AND DIVISION 26 SPECIFICATIONS.

ALL CONDUCTOR RUNS SHALL BE PROPERLY SUPPORTED AND

CONCEALED WHENEVER POSSIBLE. COORDINATE AIR TERMINAL

MOUNTING AND LOCATIONS WITH TANK AND PUMP HOUSE SHOP

DRAWINGS. ALL METAL BODIES, SUCH AS EXHAUST FANS, VENTS,

DRAINS, LADDERS, SHALL BE BONDED TO THE LIGHTNING

PROTECTION SYSTEM IN ACCORDANCE WITH NFPA 780. PROVIDE

A UL MASTER LABEL FOR THE LIGHTNING PROTECTION SYSTEM.

E

E

GEN

E

E

E

E

BR-50

BR-49

N

BR-47

BR-48

BR-46

T

BR46-2

BR46-1

N

N

13.2 (BWN)

BR-46A

N

D R

O P

.5

T

T

PARKING AREA

( ASPHALT )

P

P

P

S

S

I.E.=

T.E.=

S.M.H.

19.05

17.25

DROP=17.71

I.E.=

T.E.=

S.M.H.

18.86

17.51

I.E.=

T.E.=

S.M.H.

17.43

CLOG.

INV.=9.04

INV.=9.25

INV.=9.38

S

S

GYM

BASKETBALL

COURT

EXISTING STRUCTURE

S T

R U

C T

U R

E

PARKING AREA

( ASPHALT )

F .F .E

.2

METAL CAP

METAL CAP

METAL CAP

F.F.E.=20.45F.F.E.=20.54

GREEN AREA

GREEN AREA

GREEN AREA

PARKING AREA

( ASPHALT )

PARKING AREA

( ASPHALT )

GREEN AREA

C O

L U

M B

U

R E

E T

T.E.=

I.E.=

C.B.

25.76

23.93

T.E.=

I.E.=

S.S.M.H.

26.87

23.85

I.E.= 15.22

BORINQUENEER STREET

T.E.=

I.E.=

S MH

17.94

17.00

T.E.=

I.E.=

S MH

19.84

18.51

T.E.=

I.E.=

S.S. MH

19.78

S S

T

T

F.F.E.=18.85

GAZEBO

F.F.E.=20.34

S T R E E T

S T R E E T

HOSEBIP

STA-113

CO

CO

S

T.E.=

I.E.=

S.M.H.

18.21

16.49

GREEN AREA

CO

STA-1819-5

T.E.=

I.E.=

S.M.H.

15.46

14.35

N

40’ 20’ 0 40’ A1

TELECOMMUNICATIONS SITE PLAN

PARTIAL ELECTRICAL /

C

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-ES-002.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

PALMAS PLANTATION 133 FR. DR.

TEL: (787) 360-6027

ROBERT E. PENNOCK

XXX

XXX

XXX

XXX

EXP. 02/28/13

FL REGISTRATION: #PE43673

MICHAEL J. CAHILL, PE

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E S

.d g n

:5

:4

W9133N-04-D-0001430010

100% - ISSUED FOR BID

04 NOVEMBER 2011

DATE:

EMAIL: ROBERTPR22@GMAIL.COM

HUMACAO, P.R. 00791-6026

GENERAL NOTES KEY NOTES

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu Cu

Cu

C u

C u

C u

C u

C u

C u u C

C u

C u

C u

B.

A.

ET-503

A1

ET-503

A3

ET-503

A1

ET-502

A1

ET-504

C1

ET-504

A3 ET-504

A1

ET-504

C1 x x x x x x x x x x C xu

C xu

C xu

C xu

C xu

TMH1

C uCx uCx uCx uCx uCx uCx uCx uCx uCx uCx uCx uCx uCx

TMH25

EXISTING

TMH26

EXISTING

C

C

C

C

C

MANHOLE

EXISTING SECURE

M A

T C

H

L

IN

E

S

E S

M A

T

E

S

E S

C

RIVERA AT PH. NUMBER (787) 707-2636.

(NEC) POINT OF CONTACT (POC) MR. PEDRO COLON

BE COORDINATED THROUGH FORT BUCHANAN’S DOIM

TELECOMMUNICATIONS MAINTENANCE HOLES SHALL

INSTALLATION OF ALL DUCTBANKS TO EXISTING

SYMBOLS, ABBREVIATIONS AND GENERAL NOTES.

REFER TO DWG E-001 FOR ELECTRICAL AND TELECOM

CONTACT.SEE SHEETS ET-601 AND ET-603 FOR CABLE ROUTE.

COORDINATE WITH FORT BUCHANAN’S DOIM (NEC) POINT OF

SPLICE 600 PAIR COPPER CABLE TO EXISTING COPPER CABLE.

SEE SHEETS ET-601 AND ET-603 FOR CABLE ROUTE.

COORDINATE WITH FORT BUCHANAN’S DOIM POINT OF CONTACT.

PLACE 96 STRAND SMF CABLE IN EXISTING SPARE INNER DUCT.

RESTORE PAVEMENT TO EXISTING CONDITION.

CAP SECURE 2-WAY DUCTBANK FOR FUTURE USE.

TMH 25. PROVIDE WATER TIGHT CONNECTORS.

CORE DRILL AND CONNECT 6-WAY DUCTBANK TO EXISTING

TO EXISTING TMH25.

TELECOMMUNICATIONS MAINTENANCE HOLE ADJACENT

CONNECT SECURE 2-WAY DUCTBANK TO EXISTING SECURE

STRANDS 25-96 FOR FUTURE PRARNG JFHQ.

RC TO 96 STRAND (STRANDS 1-24), CLEAR AND CAP (C+C)

SPLICE 24 STRAND FIBER OPTIC CABLE FEEDING PRARNG

PAIRS 201-400 FOR FUTURE PRARNG JFHQ.

600 PAIR CABLE (PAIRS 1-200), CLEAR AND CAP (C+C)

SPLICE 200 PAIR COPPER CABLE FEEDING PRARNG RC TO 7

STRANDS 25-96 FOR FUTURE PRARNG JFHQ.

RC TO 96 STRAND (STRANDS 1-24), CLEAR AND CAP (C+C)

SPLICE 24 STRAND FIBER OPTIC CABLE FEEDING PRARNG

PAIRS 201-400 FOR FUTURE PRARNG JFHQ.

600 PAIR CABLE (PAIRS 1-200), CLEAR AND CAP (C+C)

SPLICE 200 PAIR COPPER CABLE FEEDING PRARNG RC TO

BR-46A

S. HANSBERRY

B. HERNKE

PARTIAL ELECTRICAL / TELECOMMUNICATION

ES-002

TOPO

SEE DWG ES-003

FOR CONTINUATION

SEE DWG ES-001

13.2 (BWN)

Cx u

Cx u

Cx u

Cx u u u u uu u uu u uu u u u u u u u u u u u u u u u u u

Cx Cx Cx Cx Cx Cx Cx Cx Cx Cx Cx Cx Cx

CC

C

CC

C

CC

C

C

C

C x xx x x xx x xx x x

C

C

C x x x u xC u xC

C

C x u u xC

T

T

T

T

T

T u x u xC u xC

C u xC x u

C u xC u x u xC u C x u C x u xC

Cx u u xC

C u xC u x u xC

C u xC x u u xC u

C xC u x u xC

C u u

C x u

C uCx uCx u

C x u C x u C x u C x x x

C u x

C

T x u

Cx u

Cx u

T-366

T-396

T-397

S-381

S-387

T-378

TENNIS

SOUTH TERMINAL RD.

H O

W A

IV

E

D

EP

O

S. HANSBERRY

B. HERNKE

PARTIAL TELECOMMUNICATION

ES-003

40’ 20’ 0 40’ A1

TELECOMMUNICATIONS SITE PLAN

PARTIAL ELECTRICAL /

TMH48

EXISTING

TMH49

EXISTING

TMH50

EXISTING

TMH51

EXISTING

VAULT

EXISTING

TMH1A

EXISTING

TMH30

EXISTING

c p w w o rk in g jf i_ p w is e c a m p o s m c d m s

P R

R C

E S

.d g n

:5

:2

READINESS CENTER (RC)

NO. DATE REVISIONS

SHEET

REVISION

DRAWING NO.

OF

FILE NO.CONTRACT NO.

DESIGNED BY:

DRAWN BY:

CHECKED BY:

SCALE:

JOB NUMBER:

CADD FILE NAME:

AS NOTED

SURVEYOR:

GEOTECHNICAL ENGINEER:

F5W85001

5750 MAJOR BOULEVARD SUITE 400

ORLANDO, FLORIDA 32819

TEL (407) 903-5100

FAX (407) 903-5190

FORT BUCHANAN SAN JUAN, PR

PUERTO RICO ARMY NATIONAL GUARD

1 2 3 4 5 6

A

B

C

D

E

21 43 5 6

A

B

C

D

PR-RC-ES-003.dgn

16 CORDOBA STREET, TERRALINDA

CAGUAS, P.R. 00727

FAX. (787) 704-6215

TEL. (787) 746-5486

CENTRAL GEOTECHNICAL SERVICES

STATE ROAD No. 2, KM 56.9

BARCELONETA, P.R. 00617

TEL: (787) 846-5454

FAX; (787) 846-5425

PROFESSIONAL OF RECORD:

ELECTRICAL ENGINEER OF RECORD

PN:

PRIME A-E:

FAX; (704) 535-4020

FAASSEN & ASSOCIATES

TEL: (704) 536-9234

8526 SUNFLOWER ROAD

CHARLOTTE, NORTH CAROLINA 28227

FOOD SERVICE

CONSULTANT:

ARCHITECT:

LANDSCAPE

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.