- The fabrics used shall be inherently anti-static, flame retardant, fade and stain resistant, light filtering, standard weave and room darkening. The room darkening shall be of a level provided by full blackout blinds
- The blackout fabric used shall provide a minimum of 0% - 15% openness factor.
- The fabric weight used shall be between 6 and 21 ounces per square yard with fiberglass materials used to provide the blackout ability.
- The control system shall utilize an adjustment free continuous stainless steel ball chain rated for a minimum of 85 pounds with a clutch drag of less than 1 pound.
STATEMENT OF WORK
FOR
MARYLAND AIR NATIONAL GUARD DINING FACILITY
SUPPLY AND INSTALL DFAC BLINDS
7 SEPTEMBER 2018
1. DESCRIPTION OF SERVICES.
1.1 General Description of Work. The contractor shall be responsible for supplying all supervision, labor, materials, equipment, tools, insurance, permits, licenses, transportation, drayage, hoisting, all other aspects of material handling, layout, safety control and regulation compliance to provide the required window blinds, as outlined in this section. The Government’s estimated window measurements are as outlined below. These measurements serve solely as an estimate, the contractor shall verify any window measurements needed to make the blinds prior to starting production. Measurements taken from inside mounting of windows.
1.2. Removal of Existing Blinds. The contractor shall remove the existing blinds, rods and associated pieces for the identified area at BLDG 2030, Dining Facility. The contractor shall be responsible for collecting the removed material and putting it at a pre-identified location on the base.
2 Large Windows-280in. (W) x 75.5in. (L) x 6in. (D) 2 Small Windows-168in. (W) x 75.5in. (L) x 6in. (D)
1.3 Installation of New Blinds. The contractor shall assemble and install new blinds for BLDG 2030, Dining Facility. All required blinds shall be mounted inside the window.
1.3.1 Required Salient Characteristics. All Blinds and equipment provided shall meet or exceed the following characteristics: