M201

FIRST FLOOR

MECHANICAL

PLANS

PROJECT # NGB

DRAWN BY

DATE 01-06-2017

Date Revision Description

DRAWINGS

CONSTRUCTION

TMS @@@CHECKED BY

DRAWING NUMBER

DRAWING TITLE

N

N

N

AutoCAD SHX Text

NDI LAB

AutoCAD SHX Text

AutoCAD SHX Text

NDI X-RAY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPECIFIC PLAN NOTES

AutoCAD SHX Text DISCONNECT AND REMOVE EXISTING OUTSIDE AIR INTAKE LOUVER. POWER TO BE DISCONNECTED BY ELECTRICAL CONTRACTOR. PROVIDE TRANSFER DUCT THROUGH BLOCK WALL OPENING. (NOMINAL 15"x7" DUCT.) PROVIDE WITH TRANSFER GRILLES ON EACH SIDE OF BLOCK WALL EQUAL TO CARNES STURDICORE STYLE HEAVY DUTY GRILLES WITH 40° DEFLECTION. SIZE GRILLES TO EXTEND TO EDGE OFANGLE IRON FRAME. PRIME AND PAINT GRILLES AND ANGLE IRON TO MATCH WALL COLOR. DISCONNECT AND REMOVE EXISTING EXHAUST FAN. RETAIN CURB FOR RE-USE. SEE PLAN FOR NEW WORK. POWER TO BE DISCONNECTED BY ELECTRICAL CONTRACTOR.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NDI LAB

AutoCAD SHX Text

AutoCAD SHX Text

NDI X-RAY

AutoCAD SHX Text

AutoCAD SHX Text 10"x10" ALUMINUM EXHAUST DUCT UP TO EXHAUST FAN EF-1.EF-1..

AutoCAD SHX Text 16"x6" ALUMINUM OPEN ENDED EXHAUST DUCT.

AutoCAD SHX Text THREE 4" PVC EXHAUST DROPS DOWN TO RESPECTIVE TEST STANDEQUIPMENT (OFFSET ALONG WALL AS REQUIRED TO CENTER OVER TEST STAND.) STOP 4" PVC 12" MIN. ABOVE TEST STAND EQUIPMENT.(FIELD VERIFY). PROVIDE WITH 45° ELBOW AND CONNECTION COUPLINGADAPTER FOR CONNECTION TO TEST STAND HOSE ADAPTER.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text M

AutoCAD SHX Text INSTALL ALL NEW ALUMINUM EXHAUST DUCTWORK AS TIGHT TO THE UNDERSIDE OF STRUCTURE AS POSSIBLE.

AutoCAD SHX Text M

AutoCAD SHX Text REUSE EXISTING EQUIPMENT CURB. PROVIDE CURB ADAPTER AS NEEDED TO ALLOW FOR NEW FAN ASSEMBLY TO BE MATED TO EXISTING EQUIPMENT CURB.

AutoCAD SHX Text 6"x16" ALUMINUM OPEN ENDED EXHAUST DUCT

AutoCAD SHX Text 10"x10" ALUMINUM EXHAUST DUCT

AutoCAD SHX Text THREE 4" PVC EXHAUST DROPS DOWN TO RESPECTIVE TEST STANDEQUIPMENT (OFFSET ALONG WALL AS REQUIRED TO CENTER OVER TEST STAND.) STOP 4" PVC 12" MIN. ABOVE TEST STAND EQUIPMENT.(FIELD VERIFY). PROVIDE WITH 45° ELBOW AND CONNECTION COUPLINGADAPTER FOR CONNECTION TO TEST STAND HOSE ADAPTER.

AutoCAD SHX Text SLIGHTLY EXTEND 4" EXHAUST DUCTS INTO 6"x16"OPEN END DUCT TO ESSENTIALLY CREATE A THIMBLE CONNECTION. DO NOT DIRECT CONNECT THE 4" DO NOT DIRECT CONNECT THE 4" DIRECT CONNECT THE 4" EXHAUST DUCTS TO THE 6"x16" EXHAUST MAIN.

AutoCAD SHX Text

TEST STAND EQUIPMENT SHOWN FOR INTENT.

AutoCAD SHX Text

FINAL CONNECTION TO TEST STAND EQUIPMENT BY OWNER.

AutoCAD SHX Text EF-1: ALUMINUM/CORROSION RESISTANT ROOF STYLE EXHAUST FAN RATED : ALUMINUM/CORROSION RESISTANT ROOF STYLE EXHAUST FAN RATED FOR 120 CFM AT 0.25" ESP, 120V. EQUAL TO COOK 70C15DH. PROVIDE WITH ELECTRONIC SPEED CONTROLLER FOR BALANCING PURPOSES. POWER TO BE EXTENDED BY ELECTRICAL CONTRACTOR. FAN TO RUN CONTINUOUS.

AutoCAD SHX Text MOTOR OPERATED DAMPER INTERLOCKED WITH FAN CONTROL SWITCH. LOCATE SWITCH ON WALL OF TEST STAND EQUIPMENT. FIELD VERIFY.

AutoCAD SHX Text

RELOCATED LIGHT FIXTURE SHOWN FOR COORDINATION.

AutoCAD SHX Text

RELOCATED LIGHT FIXTURE SHOWN FOR COORDINATION.

AutoCAD SHX Text INSTALL ALL NEW ALUMINUM EXHAUST DUCTWORK AS TIGHT TO THE UNDERSIDE OF STRUCTURE AS POSSIBLE.

AutoCAD SHX Text

EXISTING STRUCTURAL JOISTS SHOWN FOR COORDINATION INTENT.

AutoCAD SHX Text

BUILDING 2050, 175TH WG

AutoCAD SHX Text

BALTIMORE MARYLAND

AutoCAD SHX Text

235 CEF

AutoCAD SHX Text

NDI LAB X-RAY ROOM EXHAUST

AutoCAD SHX Text

2701 EASTERN BLVD, 2050 BUILDING

AutoCAD SHX Text

BALTIMORE, MARYLAND 21220

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

FIRST FLOOR MECHANICAL DEMOLITION PLAN

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text M201

AutoCAD SHX Text

FIRST FLOOR MECHANICAL PLAN

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text M201

AutoCAD SHX Text

SECTION OF NDI X-RAY ROOM

AutoCAD SHX Text

SCALE: N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text M201