E201
FIRST FLOOR
ELECTRICAL
PLANS
PROJECT # NGB
DRAWN BY
DATE 01-06-2017
Date Revision Description
DRAWINGS
CONSTRUCTION
TMS @@@CHECKED BY
DRAWING NUMBER
DRAWING TITLE
N
N
N
AutoCAD SHX Text
NDI LAB
AutoCAD SHX Text
AutoCAD SHX Text
NDI X-RAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING LIGHT FIXTURE TO REMAIN. SHOWN FOR COORDINATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPECIFIC PLAN NOTES
AutoCAD SHX Text DISCONNECT EXISTING LIGHT FIXTURE TO ALLOW FOR INSTALLATION OF NEW EXHAUST DUCTWORK. RETAIN LIGHT FIXTURE FOR RE-USE. REINSTALL EXISTING LIGHT FIXTURE BELOW NEW EXHAUST DUCTWORK. INSTALL LIGHT FIXTURE AS TIGHT TO UNDERSIDE OF DUCTWORK AS POSSIBLE. FIELD VERIFY. PROVIDE SURFACE MOUNTED DUPLEX ELECTRICAL OUTLET WITH METAL CONDUIT EXPOSED ALONG THE WALL AND RUN THROUGH CEILINGS BACK TO ELECTRICAL PANEL. FIELD VERIFY ELECTRICAL PANEL LOCATION AND CONDUIT ROUTING. DISCONNECT POWER TO EXISTING MOTOR OPERATED DAMPER AT ROOF. DISCONNECT POWER TO EXISTING ROOF EXHAUST FAN. RETAIN ELECTRICAL SERVICE FOR RE-USE WITH NEW MECHANICAL PLAN. CONNECT/EXTEND POWER TO NEW EXHAUST FAN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NDI LAB
AutoCAD SHX Text
AutoCAD SHX Text
NDI X-RAY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING LIGHT FIXTURE TO REMAIN. SHOWN FOR COORDINATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
BUILDING 2050, 175TH WG
AutoCAD SHX Text
BALTIMORE MARYLAND
AutoCAD SHX Text
235 CEF
AutoCAD SHX Text
NDI LAB X-RAY ROOM EXHAUST
AutoCAD SHX Text
2701 EASTERN BLVD, 2050 BUILDING
AutoCAD SHX Text
BALTIMORE, MARYLAND 21220
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL DEMOLITION PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text E201
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text E201