STATEMENT OF NEED

Gen Mitchell IAP ANGB, WI 21 September, 2018

1. GENERAL: The Government requires multiple Portable Plate Barrier Systems for use on General Mitchell Air National Guard Base, Milwaukee, Wisconsin.

1.1. Requirement: The request is for two (2) Portable Plate Barrier Systems with clear opening sizes of (1) 12ft and (1) 16ft.

1.2. Specific Requirement: Will need the following for the two (2) Portable Plate Barrier Systems:

1.2.1. All must be able to be surface mounted

1.2.2. All must be hot-dip galvanized per ASTM A123

1.2.3. Will need one (1) plate barrier system with 12ft clear opening

1.2.4. Will need one (1) plate barrier system with 16ft clear opening

1.2.5. Will need plate barrier systems to include fully integrated, uninterruptible power supply (UPS) to provide 160+ operating cycles per charge

1.2.6. Will need plate barrier systems to include battery operated hydraulic pumps w/ control stations

1.2.7. Will need Hydraulic oil/pumps designed and capable of operating in temperatures as cold as -22℉ and include a heater element for the hydraulic oil

1.2.8. Must be compatible with 110 voltage

1.2.9. Must include a two button control pendant

1.3. Must have a back-up manual operation with hand pump

1.3.1. Must have a normal operation cycle speed of 3 seconds to open/close

1.3.2. Must be tested per the U.S. Department of State standard SD-STD-02.01 Rev. A and DOD K4/L2 crash test certified with a 15,000 pound vehicle traveling 30 mph with less than 20 feet penetration of the cargo bed

1.3.3. Must be designed and capable of handling high-traffic situations cycling up to 300 times a day, 5 days a week

1.3.4. Must include integral lifting eyes on each buttress make it easy to hoist and set in place exactly where needed

1.3.5. Must include heavy-duty cylinders with double-lip wiper seals, heavy-duty packing glands, oversized ports and internal limit switches as well as quick-connect HPU hose connections

1.3.6. Must include ALGRIP® slip-resistant surface on plate

1.3.7. Each basic system must consist of:

- Quick deployment mobile barrier assembly
- hinged, rigid crash plate assembly
- complete instructions, to include start up and trouble-shooting manual

2. DELIVERY: FOB Destination to 1919 E Grange Ave, Milwaukee, WI 53207