550_WD-S.PDF
PDF 1 MB Posted
- Attached to
- Audio Visual Upgrade/Solution Federal contract opportunity
- Solicitation number
- W912J2-17-Q-3002
About this file
Drawings - 2
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 550_A2.0.pdf | ||
| SOW_AV_550_-_Updated_1-31.pdf | ||
| W912J2-17-Q-3002__AV_Upgrade_Q_and_A.pdf | ||
| 550_WD-S.PDF | ||
| AFSSI_7700_EMSEC.pdf | ||
| AFSSI_7703_PDS.pdf | ||
| 15-01-05_Electrical_and_Communications_Engineering.pdf | ||
| AFSSI_7702_CNTRMeas.pdf | ||
| 550_A2.0.pdf | ||
| SOW_AV_550_-_Updated_1-31.pdf | ||
| SOW_AV_550_-_Final.docx | DOCX document |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RELOCATE
BATHROOM
DOOR
NORTH WALL:
2X4 OR 2X6 @ 16" O.C. FRAMED WALL WITH 3/4"
PLYWOOD (NOT GYP.), ALIGN FRAMING TO
CONCEAL EXSTG. (4) 2" CONDUIT ON WALL
C E
N T
E R
L
IN
E O
F T
H E
R O
O M
ALL OTHER FURRED WALLS:
2X2 OR 2X4 (FLAT) @ 24" O.C. FURRING
WITH 3/4" PLYWOOD (NOT GYP.)
A1.0
IR NA
A RD
A
GU
NALO
TI
DATE:
DRAWN BY:
FILE:
REV:
BASE ENGINEER:
PROJECT #:
PHONE NUMBERS:
CONTRACT #:
7' -0
A
F F
7' -0
A
F F
8' -0
A
F F
8' -0
A
F F
F L
O O
R
F L
O O
R
8' -0
A
F F
8' -0
A
F F
C E
N T
E R
L
IN
E O
F T
H E
R O
O M
STAY
STAY
D3D A D
JU
ST
'-0
"A F
F
R E
M O
V E
ADJUST 7'-0"AFF
ADJUST 7'-0"AFF
7' -0
A
F F
7' -0
A
F F
7' -0
A
F F
7' -0
A
F F
7' -0
A
F F
7' -0
A
F F
WEST WALL:
REMOVE/ADJUST
ALL EXISTING
OUTLETS/PORTS
STAY
STAY
STAY
STAY
STAY
1' -6
"A F
F S
T A
Y 1'
-6 "A
F F
S T
A Y
8' -0
"A F
F S
T A
Y 7'
-0 "A
F F
S T
A Y
1' -6
"A F
F ADJUST 7'-0"AFF
ADJUST 7'-0"AFF
THERM. STAY
REMOVE
REMOVE
STAY 1'-6"AFF
STAY 1'-6"AFF
1'-6"AFF
7'-0"AFF
7'-0"AFF
7'-0"AFF
STAY 1'-6"AFF
REMOVE
STAY
REMOVE
7'-0"AFF
7' -0
"A F
F 7'
-0 "A
F F
1' -6
"A F
F
1' -6
"A F
F
1' -6
"A F
F
ST
A
Y
ST
A
Y
'-0 "A
F F
4' -0
"A F
F
A L
A R
M
A D
JU
ST
'-0
"A F
F
R E
M O
V E
24"X12" TYPICAL
HINGED ALUM
ACCESS PANEL
WITH FLUSH
MOUNT LOCK
ADJUST FLOOR
60"X12" HINGED
ALUM ACCESS
PANEL WITH FLUSH
MOUNT LOCK
EXSTG. (2) 2"
CONDUIT TO
REMAIN
EXSTG. (2) 2"
CONDUIT TO
REMAIN
F L
O O
R
F L
O O
R
7'-0" STAY
STAY 1'-6"AFF
STAY 1'-6"AFF
1'-6"AFF
(2) BOXES WITH
CONDUIT TO
DOOR FRAME FOR
BALANCE MAGNET
DOOR SWICTH (1) BOX WITH CONDUIT
TO DOOR FRAME FOR
BALANCE MAGNET
DOOR SWITCH
1' -6
"A F
F S
T A
Y
1' -6
"A F
F 1'
-6 "A
F F
ADD (2) 1"
CONDUIT TO RUN
FROM TRENCH UP
INTO ATTIC FOR
(8) SIPR WIRES
7'-0"AFF
ADJUST FLOOR
ADJUST FLOOR
ADJUST FLOOR
ADJUST FLOOR
ADJUST FLOOR
PWR
SIPR
SI
P
R
PWR
NIPR
ST
A
Y
4' -6
A
F F
4' -6
A
F F
7'-0" AFF
4' -6
A
F F
4' -6
A
F F
1'-6"AFF
AV/VGA INPUT/OUTPUT
CCTV
SIPR 4 PLEX
4 PLEX
NIPR 4 PLEX
AV PORT
AV TOUCH PANEL
NOTES:
1- ALL NEW PORTS AND OUTLETS AT
3'-0" ABOVE CONCRETE FLOOR
UNLESS NOTED OTHERWISE
2- ADJUST ALL EXISTING PORTS AND
OUTLETS TO BE 3'-0" ABOVE
CONCRETE FLOOR UNLESS NOTED
OTHERWISE
3- ALL NEW SWITCHES AT 4'-0" ABOVE
CONCRETE FLOOR UNLESS NOTED
OTHERWISE
4- ADJUST ALL EXISTING SWITCHES
TO 4'-0" ABOVE CONCRETE FLOOR
OR REMOVE AS NOTED
5- FLOOR OUTLETS TO BE __________
OR COMPARABLE IN QUALITY AND
COST AS APPROVED BY VOLK COMM
MISC. AS NOTED
PHONE
D
SINGLE SWITCH
3-WAY SWITCH
DIMMER SWITCH
NEW FIXTURES
EXISTING FIXTURES
LEGEND
AV SPEAKERS
E1.0
IR NA
A RD
A
GU
NALO
TI
DATE:
DRAWN BY:
FILE:
REV:
BASE ENGINEER:
PROJECT #:
C E
N T
E R
L
IN
E O
F T
H E
R O
O M
D
SINGLE SWITCH
3-WAY SWITCH
DIMMER SWITCH
NEW FIXTURES
EXISTING FIXTURES
LEGEND
AV SPEAKERS
1X4 FLUOR. CLNG LIGHT
RECESSED LIGHT
EXHAUST FAN
FLUOR. WALL LIGHT
SWITCH LINE
DEMO FIXTURES
ACCOUS. CLNG CLOUD
MASS NOT. SPEAKERS
HVAC SUPPLY
HVAC RETURN
R1.0
IR NA
A RD
A
GU
NALO
TI
DATE:
DRAWN BY:
FILE:
REV:
BASE ENGINEER:
PROJECT #:
C E
N T
E R
L
IN
E O
F T
H E
R O
O M
PULL STATION
PULL STATION
PULL STATION
36" OFFSET FROM
ALL FIXTURES
NEW FIXTURES
EXISTING FIXTURES
LEGEND
STROBE/HORN/LIGHT
ASSEMBLY, MOUNT @
80"-96" AFF
R/F HEAT DETECTOR
135 RATE OF RISE
190 FIXED
SMOKE DETECTOR
NOTE: 2 OR MORE STROBES
IN SAME FIELD OF VIEW
MUST BE SYNCHRONIZED
F1.0
IR NA
A RD
A
GU
NALO
TI
DATE:
DRAWN BY:
FILE:
REV:
BASE ENGINEER:
PROJECT #:
| 550_A1.0 |
| 550_E1.0 |
| 550_R1.0 |
| 550_F1.0 |