CLIN Summary Facility Investment Summary
| CLIN | Total | |
| 0001 | Base Period Facilities Maintenance Services Firm Fixed-Price | $ - 0 |
| 0002 | Base Period Service Calls Firm Fixed-Price | $ - 0 |
| 0003 | Base Period Indefinite Quantity | $ 250,000.00 |
| 1001 | First Option Period Facilities Maintenance Services Firm Fixed-Price | $ - 0 |
| 1002 | First Option Service Calls Firm Fixed-Price | $ - 0 |
| 1003 | First Option Period Indefinite Quantity | $ 250,000.00 |
| 2001 | Second Option Period Facilities Maintenance Services Firm Fixed-Price | $ - 0 |
| 2002 | Second Option Service Calls Firm Fixed-Price | $ - 0 |
| 2003 | Second Option Period Indefinite Quantity | $ 250,000.00 |
| 3001 | Third Option Period Facilities Maintenance Services Firm Fixed-Price | $ - 0 |
| 3002 | Third Option Service Calls Firm Fixed-Price | $ - 0 |
| 3003 | Third Option Period Indefinite Quantity | $ 250,000.00 |
| 4001 | Fourth Option Period Facilities Maintenance Services Firm Fixed-Price | $ - 0 |
| 4002 | Fourth Option Service Calls Firm Fixed-Price | $ - 0 |
| 4003 | Fourth Option Period Indefinite Quantity | $ 250,000.00 |
| $ 1,250,000.00 | |
| * Inflation rates based on National Defense Budget Estimates for FY2013 Green Book, Page 55 |
&F
&A &P of &N
Site Cost Summary
| Preventive Maintenance Services CLIN 0001 by Site | |||
| Site | CLINs | ELINs | |
| FL003 | 0001AA | A100 Through A121 | $ - 0 |
| FL014 | 0001AB | A122 Through A143 | $ - 0 |
| FL017 | 0001AC | A144 Through A167 | $ - 0 |
| FL021 | 0001AD | A168 Through A207 | $ - 0 |
| FL022 | 0001AE | A208 Through A249 | $ - 0 |
| FL023 | 0001AF | A250 Through A273 | $ - 0 |
| FL031 | 0001AG | A274 Through A311 | $ - 0 |
| FL037 | 0001AH | A312 Through A348 | $ - 0 |
| FL041 | 0001AI | A349 Through A385 | $ - 0 |
| FL103 | 0001AJ | A386 Through A417 | $ - 0 |
| FL115 | 0001AK | A418 Through A459 | $ - 0 |
| FL125 | 0001AL | A450 Through A482 | $ - 0 |
| FL126 | 0001AM | A483 Through A522 | $ - 0 |
| FL127 | 0001AN | A523 Through A562 | $ - 0 |
| FL134 | 0001AO | A563 Through A573 | $ - 0 |
| FL136 | 0001AP | A574 Through A594 | $ - 0 |
| FL137 | 0001AQ | A595 Through A619 | $ - 0 |
$ - 0
| Preventive Maintenance Services CLIN 1001 by Site | |||
| Site | CLINs | ELINs | |
| FL003 | 1001AA | B100 Through B121 | $ - 0 |
| FL014 | 1001AB | B122 Through B143 | $ - 0 |
| FL017 | 1001AC | B144 Through B167 | $ - 0 |
| FL021 | 1001AD | B168 Through B207 | $ - 0 |
| FL022 | 1001AE | B208 Through B249 | $ - 0 |
| FL023 | 1001AF | B250 Through B273 | $ - 0 |
| FL031 | 1001AG | B274 Through B311 | $ - 0 |
| FL037 | 1001AH | B312 Through B348 | $ - 0 |
| FL041 | 1001AI | B349 Through B385 | $ - 0 |
| FL103 | 1001AJ | B386 Through B417 | $ - 0 |
| FL115 | 1001AK | B418 Through B459 | $ - 0 |
| FL125 | 1001AL | B450 Through B482 | $ - 0 |
| FL126 | 1001AM | B483 Through B522 | $ - 0 |
| FL127 | 1001AN | B523 Through B562 | $ - 0 |
| FL134 | 1001AO | B563 Through B573 | $ - 0 |
| FL136 | 1001AP | B574 Through B594 | $ - 0 |
| FL137 | 1001AQ | B595 Through B619 | $ - 0 |
| $ - 0 | |||
| Preventive Maintenance Services CLIN 2001 by Site | |||
| Site | CLINs | ELINs | |
| FL003 | 2001AA | C100 Through C121 | $ - 0 |
| FL014 | 2001AB | C122 Through C143 | $ - 0 |
| FL017 | 2001AC | C144 Through C167 | $ - 0 |
| FL021 | 2001AD | C168 Through C207 | $ - 0 |
| FL022 | 2001AE | C208 Through C249 | $ - 0 |
| FL023 | 2001AF | C250 Through C273 | $ - 0 |
| FL031 | 2001AG | C274 Through C311 | $ - 0 |
| FL037 | 2001AH | C312 Through C348 | $ - 0 |
| FL041 | 2001AI | C349 Through C385 | $ - 0 |
| FL103 | 2001AJ | C386 Through C417 | $ - 0 |
| FL115 | 2001AK | C418 Through C459 | $ - 0 |
| FL125 | 2001AL | C450 Through C482 | $ - 0 |
| FL126 | 2001AM | C483 Through C522 | $ - 0 |
| FL127 | 2001AN | C523 Through C562 | $ - 0 |
| FL134 | 2001AO | C563 Through C573 | $ - 0 |
| FL136 | 2001AP | C574 Through C594 | $ - 0 |
| FL137 | 2001AQ | C595 Through C619 | $ - 0 |
| $ - 0 | |||
| Preventive Maintenance Services CLIN 3001 by Site | |||
| Site | CLINs | ELINs | |
| FL003 | 3001AA | D100 Through D121 | $ - 0 |
| FL014 | 3001AB | D122 Through D143 | $ - 0 |
| FL017 | 3001AC | D144 Through D167 | $ - 0 |
| FL021 | 3001AD | D168 Through D207 | $ - 0 |
| FL022 | 3001AE | D208 Through D249 | $ - 0 |
| FL023 | 3001AF | D250 Through D273 | $ - 0 |
| FL031 | 3001AG | D274 Through D311 | $ - 0 |
| FL037 | 3001AH | D312 Through D348 | $ - 0 |
| FL041 | 3001AI | D349 Through D385 | $ - 0 |
| FL103 | 3001AJ | D386 Through D417 | $ - 0 |
| FL115 | 3001AK | D418 Through D459 | $ - 0 |
| FL125 | 3001AL | D450 Through D482 | $ - 0 |
| FL126 | 3001AM | D483 Through D522 | $ - 0 |
| FL127 | 3001AN | D523 Through D562 | $ - 0 |
| FL134 | 3001AO | D563 Through D573 | $ - 0 |
| FL136 | 3001AP | D574 Through D594 | $ - 0 |
| FL137 | 3001AQ | D595 Through D619 | $ - 0 |
| $ - 0 | |||
| Preventive Maintenance Services CLIN 4001 by Site | |||
| Site | CLINs | ELINs | |
| FL003 | 4001AA | E100 Through E121 | $ - 0 |
| FL014 | 4001AB | E122 Through E143 | $ - 0 |
| FL017 | 4001AC | E144 Through E167 | $ - 0 |
| FL021 | 4001AD | E168 Through E207 | $ - 0 |
| FL022 | 4001AE | E208 Through E249 | $ - 0 |
| FL023 | 4001AF | E250 Through E273 | $ - 0 |
| FL031 | 4001AG | E274 Through E311 | $ - 0 |
| FL037 | 4001AH | E312 Through E348 | $ - 0 |
| FL041 | 4001AI | E349 Through E385 | $ - 0 |
| FL103 | 4001AJ | E386 Through E417 | $ - 0 |
| FL115 | 4001AK | E418 Through E459 | $ - 0 |
| FL125 | 4001AL | E450 Through E482 | $ - 0 |
| FL126 | 4001AM | E483 Through E522 | $ - 0 |
| FL127 | 4001AN | E523 Through E562 | $ - 0 |
| FL134 | 4001AO | E563 Through E573 | $ - 0 |
| FL136 | 4001AP | E574 Through E594 | $ - 0 |
| FL137 | 4001AQ | E595 Through E619 | $ - 0 |
$ - 0
&F
Page &P OF &N
BASE PERIOD FFP
| ATTACHMENT J-0200000-07 |
| EXHIBIT LINE ITEM NUMBERS |
| PROVIDE PRICES TO PROVIDE MAINTENANCE AND REPAIR SERVICES - FIRM FIXED-PRICE IN ACCORDANCE WITH SECTION C, SPEC ITEM 3 | ||||||
| CLIN 0002 - Base Period - Service Calls | ||||||
| CLIN | Spec Item | DESCRIPTION | QTY | Units | Unit Price | Total Amount |
0002 3.1 Perform Service Calls 500 each $ - 0 $ - 0
| CLIN 0001 - Base Period - Facilities Maintenance Services - (ELINS A100 Through A619) | ||||||
| ELIN | Spec Item | DESCRIPTION | QTY | Frequency | Total Occurrences | |
| FL003 | LT ALEXANDER NINNINGER JR USAR--5515 NW 15TH AVENUE--FORT LAUDERDALE, FL 33309-2799 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A100 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A101 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A102 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A103 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A104 | 3.2.1.13 | Develop And Implement Preventive Maintenance Program For HVAC Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A105 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A106 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A107 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A108 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A109 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A110 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A111 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A112 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A113 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A114 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A115 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A116 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A117 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A118 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A119 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A120 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A121 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AA (Items A100 Through A121) $ - 0
| FL014 | JAMES WEST USARC--905 NORTH INGRAHAM AVENUE--LAKELAND, FL 33801-2080 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A122 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A123 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A124 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A125 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A126 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A127 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A128 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A129 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A130 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A131 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A132 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A133 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A134 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A135 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A135a | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A135b | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A136 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A137 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A138 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A139 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A140 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A141 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A142 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
| A143 | 3.4.13 | Develop and implement a program to inspect, and make all necessary repairs to Irrigation Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AB (Items A122 Through A143) $ - 0
| FL017 | COL F.M. WILLIAMS USARC--11700 NW 27TH AVENUE--MIAMI, FL 33167-2698 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A144 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A145 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A146 | 3.2.1.7 | Develop And Implement Preventive Maintenance Program For Rooftop Units | 12 | Month | $ - 0 | $ - 0 |
| A147 | 3.2.1.13 | Develop And Implement Preventive Maintenance Program For HVAC Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A148 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A149 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A150 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A151 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A152 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A153 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A154 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A155 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A156 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A157 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A158 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A159 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A160 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A161 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A162 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A163 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A164 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A165 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A166 | 3.4.10 | Develop and implement a program to inspect, and make all necessary repairs to Vault Doors | 12 | Month | $ - 0 | $ - 0 |
| A167 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AC (Items A144 Through A167) $ - 0
| FL021 | ORANGE COUNTY USARC--3701 CORRINE DRIVE--ORLANDO, FL 32803-2499 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A168 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A169 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A170 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A171 | 3.2.1.7 | Develop And Implement Preventive Maintenance Program For Rooftop Units | 12 | Month | $ - 0 | $ - 0 |
| A172 | 3.2.1.12 | Develop And Implement Preventive Maintenance Program For Mini-Splits | 12 | Month | $ - 0 | $ - 0 |
| A173 | 3.2.1.13 | Develop And Implement Preventive Maintenance Program For HVAC Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A174 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A175 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A176 | 3.2.3 | Develop And Implement Preventive Maintenance Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A177 | 3.2.3.1 | Develop And Implement Boiler and UPV Seasonal Start-Up and Shutdown | 12 | Month | $ - 0 | $ - 0 |
| A178 | 3.2.3.2 | Develop And Implement Boiler Water Testing and Treatment | 12 | Month | $ - 0 | $ - 0 |
| A179 | 3.2.5 | Develop And Implement Preventive Maintenance Program For Emergency Generator Systems | 12 | Month | $ - 0 | $ - 0 |
| A180 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A181 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A182 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A183 | 3.2.10.3 | Develop And Implement Preventive Maintenance Program For Circulating Pumps | 12 | Month | $ - 0 | $ - 0 |
| A184 | 3.2.10.4 | Develop And Implement Preventive Maintenance Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A185 | 3.2.10.6 | Develop And Implement Preventive Maintenance Program For Sump Pumps | 12 | Month | $ - 0 | $ - 0 |
| A186 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A187 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A188 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A189 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A190 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| A191 | 3.2.13 | Develop And Implement Preventive Maintenance Program For Lightning Arrestors and Grounding Devices | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A192 | 3.3.2 | Develop And Implement an Inspection, Testing, and Certification Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A193 | 3.3.4 | Develop And Implement an Inspection, Testing, and Certification Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A194 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A195 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A196 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A197 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A198 | 3.4.1.3 | Develop and implement a program to inspect, and make all necessary repairs to Military Equipment Parking Lights | 12 | Month | $ - 0 | $ - 0 |
| A199 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A200 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A201 | 3.4.2 | Clean grease traps and remove and dispose of grease from designated Grease Traps | 12 | Month | $ - 0 | $ - 0 |
| A202 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A203 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A204 | 3.4.6 | Develop and implement a program to inspect, and make all necessary repairs to Oil Water Separators | 12 | Month | $ - 0 | $ - 0 |
| A205 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A206 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A207 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AD (Items A168 Through A207) $ - 0
| FL022 | ORANGE COUNTY USARC--3701 CORRINE DRIVE--ORLANDO, FL 32803-2499 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A208 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A209 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A210 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A211 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A212 | 3.2.1.7 | Develop And Implement Preventive Maintenance Program For Rooftop Units | 12 | Month | $ - 0 | $ - 0 |
| A213 | 3.2.1.12 | Develop And Implement Preventive Maintenance Program For Mini-Splits | 12 | Month | $ - 0 | $ - 0 |
| A214 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A215 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A216 | 3.2.3 | Develop And Implement Preventive Maintenance Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A217 | 3.2.3.1 | Develop And Implement Boiler and UPV Seasonal Start-Up and Shutdown | 12 | Month | $ - 0 | $ - 0 |
| A218 | 3.2.3.2 | Develop And Implement Boiler Water Testing and Treatment | 12 | Month | $ - 0 | $ - 0 |
| A219 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A220 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A221 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A222 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A223 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A224 | 3.2.10.3 | Develop And Implement Preventive Maintenance Program For Circulating Pumps | 12 | Month | $ - 0 | $ - 0 |
| A225 | 3.2.10.4 | Develop And Implement Preventive Maintenance Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A226 | 3.2.10.6 | Develop And Implement Preventive Maintenance Program For Sump Pumps | 12 | Month | $ - 0 | $ - 0 |
| A227 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A228 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A229 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A230 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A231 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| A232 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A233 | 3.3.2 | Develop And Implement an Inspection, Testing, and Certification Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A234 | 3.3.4 | Develop And Implement an Inspection, Testing, and Certification Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A235 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A236 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A237 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A238 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A239 | 3.4.1.3 | Develop and implement a program to inspect, and make all necessary repairs to Military Equipment Parking Lights | 12 | Month | $ - 0 | $ - 0 |
| A240 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A241 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A242 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A243 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A244 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A245 | 3.4.6 | Develop and implement a program to inspect, and make all necessary repairs to Oil Water Separators | 12 | Month | $ - 0 | $ - 0 |
| A246 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A247 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A248 | 3.4.9 | Develop and implement a program to inspect, and make all necessary repairs to Automated Key Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A249 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AE (Items A208 Through A249) $ - 0
| FL023 | TAFT USARC--2800 DOWDEN ROAD--ORLANDO, FL 32827-5299 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A250 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A251 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A252 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A253 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A254 | 3.2.1.7 | Develop And Implement Preventive Maintenance Program For Rooftop Units | 12 | Month | $ - 0 | $ - 0 |
| A255 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A256 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A257 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A258 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A259 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A260 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A261 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A262 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A263 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A264 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A265 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A266 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A267 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A268 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A269 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A270 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A271 | 3.4.10 | Develop and implement a program to inspect, and make all necessary repairs to Vault Doors | 12 | Month | $ - 0 | $ - 0 |
| A272 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
| A273 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AF (Items A250 Through A273) $ - 0
| FL031 | LTC LUIS E. MARTINEZ USARC--13601 S.W. 176TH STREET--(PERRINE) MIAMI, FL 33177-2500 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A274 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A275 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A276 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A277 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A278 | 3.2.1.6 | Develop And Implement Preventive Maintenance Program For Packaged Terminal Air Conditioners | 12 | Month | $ - 0 | $ - 0 |
| A279 | 3.2.1.8 | Develop And Implement Preventive Maintenance Program For Variable Air Volume (VAV) and Other Boxes | 12 | Month | $ - 0 | $ - 0 |
| A280 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A281 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A282 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A283 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A284 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A285 | 3.2.9 | Develop And Implement Preventive Maintenance Program For Weight Handling Equipment | 12 | Month | $ - 0 | $ - 0 |
| A286 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A287 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A288 | 3.2.10.3 | Develop And Implement Preventive Maintenance Program For Circulating Pumps | 12 | Month | $ - 0 | $ - 0 |
| A289 | 3.2.10.4 | Develop And Implement Preventive Maintenance Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A290 | 3.2.10.6 | Develop And Implement Preventive Maintenance Program For Sump Pumps | 12 | Month | $ - 0 | $ - 0 |
| A291 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A292 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A293 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A294 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A295 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| A296 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A297 | 3.3.1 | Develop And Implement an Inspection, Testing, and Certification Program For Weight Handling Equipment | 12 | Month | $ - 0 | $ - 0 |
| A298 | 3.3.2 | Develop And Implement an Inspection, Testing, and Certification Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A299 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A300 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A301 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A302 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A303 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A304 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A305 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A306 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A307 | 3.4.6 | Develop and implement a program to inspect, and make all necessary repairs to Oil Water Separators | 12 | Month | $ - 0 | $ - 0 |
| A308 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A309 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A310 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
| A311 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AG (Items A274 Through A311) $ - 0
| FL037 | 1LT MAX R. STOVER USARC--1420 BEACH DRIVE SE--ST. PETERSBURG, FL 33701-5697 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A312 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A313 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A314 | 3.2.1.3 | Develop And Implement Preventive Maintenance Program For Furnaces | 12 | Month | $ - 0 | $ - 0 |
| A315 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A316 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A317 | 3.2.1.6 | Develop And Implement Preventive Maintenance Program For Packaged Terminal Air Conditioners | 12 | Month | $ - 0 | $ - 0 |
| A318 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A319 | 3.2.3 | Develop And Implement Preventive Maintenance Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A320 | 3.2.3.1 | Develop And Implement Boiler and UPV Seasonal Start-Up and Shutdown | 12 | Month | $ - 0 | $ - 0 |
| A321 | 3.2.3.2 | Develop And Implement Boiler Water Testing and Treatment | 12 | Month | $ - 0 | $ - 0 |
| A322 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A323 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A324 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A325 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A326 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A327 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A328 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A329 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A330 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A331 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A332 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| A333 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A334 | 3.3.4 | Develop And Implement an Inspection, Testing, and Certification Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A335 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A336 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A337 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A338 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A339 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A340 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A341 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A342 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A343 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A344 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A345 | 3.4.9 | Develop and implement a program to inspect, and make all necessary repairs to Automated Key Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A346 | 3.4.10 | Develop and implement a program to inspect, and make all necessary repairs to Vault Doors | 12 | Month | $ - 0 | $ - 0 |
| A347 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
| A348 | 3.4.13 | Develop and implement a program to inspect, and make all necessary repairs to Irrigation Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AH (Items A312 Through A348) $ - 0
| FL041 | C. LOVEJOY USARC--4815 NORTH HUBERT AVENUE--TAMPA, FL 33614-6493 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A349 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A350 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A351 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A352 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A353 | 3.2.1.11 | Develop And Implement Preventive Maintenance Program For Humidifiers | 12 | Month | $ - 0 | $ - 0 |
| A354 | 3.2.1.12 | Develop And Implement Preventive Maintenance Program For Mini-Splits | 12 | Month | $ - 0 | $ - 0 |
| A355 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A356 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A357 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A358 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A359 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A360 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A361 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A362 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A363 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A364 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A365 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A366 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| A367 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A368 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A369 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A370 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A371 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A372 | 3.4.1.3 | Develop and implement a program to inspect, and make all necessary repairs to Military Equipment Parking Lights | 12 | Month | $ - 0 | $ - 0 |
| A373 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A374 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A375 | 3.4.3 | Service designated exhaust hoods and ducts and associated equipment | 12 | Month | $ - 0 | $ - 0 |
| A376 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A377 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A378 | 3.4.6 | Develop and implement a program to inspect, and make all necessary repairs to Oil Water Separators | 12 | Month | $ - 0 | $ - 0 |
| A379 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A380 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A381 | 3.4.9 | Develop and implement a program to inspect, and make all necessary repairs to Automated Key Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A382 | 3.4.10 | Develop and implement a program to inspect, and make all necessary repairs to Vault Doors | 12 | Month | $ - 0 | $ - 0 |
| A383 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
| A384 | 3.4.12 | Develop and implement a program to inspect, and make all necessary repairs to Vehicle Exhaust Systems | 12 | Month | $ - 0 | $ - 0 |
| A385 | 3.4.13 | Develop and implement a program to inspect, and make all necessary repairs to Irrigation Systems | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AI (Items A349 Through A385) $ - 0
| FL103 | RATTLESNAKE POINT USARC--5201 WEST TYSON AVENUE--TAMPA, FL 33611-3223 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A386 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A387 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A388 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A389 | 3.2.1.6 | Develop And Implement Preventive Maintenance Program For Packaged Terminal Air Conditioners | 12 | Month | $ - 0 | $ - 0 |
| A390 | 3.2.1.7 | Develop And Implement Preventive Maintenance Program For Rooftop Units | 12 | Month | $ - 0 | $ - 0 |
| A391 | 3.2.1.12 | Develop And Implement Preventive Maintenance Program For Mini-Splits | 12 | Month | $ - 0 | $ - 0 |
| A392 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A393 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A394 | 3.2.4 | Develop And Implement Preventive Maintenance Program For Compressed Air Systems | 12 | Month | $ - 0 | $ - 0 |
| A395 | 3.2.6 | Develop And Implement Preventive Maintenance Program For Above Ground Fuel Storage Tanks | 12 | Month | $ - 0 | $ - 0 |
| A396 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A397 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A398 | 3.2.10.4 | Develop And Implement Preventive Maintenance Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A399 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A400 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A401 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A402 | 3.2.11.3 | Develop And Implement Preventive Maintenance Program For Fire Alarm Panel Boards | 12 | Month | $ - 0 | $ - 0 |
| A403 | 3.2.13 | Develop And Implement Preventive Maintenance Program For Lightning Arrestors and Grounding Devices | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A404 | 3.3.2 | Develop And Implement an Inspection, Testing, and Certification Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A405 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A406 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services | |||||
| A407 | 3.4.1.1 | Develop and implement a program to inspect, and make all necessary repairs to Exterior Lighting Photocell Contactors and/or Time Clocks | 12 | Month | $ - 0 | $ - 0 |
| A408 | 3.4.1.2 | Develop and implement a program to inspect, and make all necessary repairs to Privately Owned Vehicle (POV) Parking Area Lights | 12 | Month | $ - 0 | $ - 0 |
| A409 | 3.4.1.4 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Light Wall Packs | 12 | Month | $ - 0 | $ - 0 |
| A410 | 3.4.1.5 | Develop and implement a program to inspect, and make all necessary repairs to Emergency Exit Signs | 12 | Month | $ - 0 | $ - 0 |
| A411 | 3.4.4 | Develop and implement a program to inspect, and make all necessary repairs to Gates | 12 | Month | $ - 0 | $ - 0 |
| A412 | 3.4.5 | Develop and implement a program to inspect, and make all necessary repairs to Fences | 12 | Month | $ - 0 | $ - 0 |
| A413 | 3.4.7 | Develop and implement a program to inspect, and make all necessary repairs to Overhead Doors | 12 | Month | $ - 0 | $ - 0 |
| A414 | 3.4.8 | Develop and implement a program to inspect, and make all necessary repairs to Automated Access Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A415 | 3.4.9 | Develop and implement a program to inspect, and make all necessary repairs to Automated Key Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A416 | 3.4.10 | Develop and implement a program to inspect, and make all necessary repairs to Vault Doors | 12 | Month | $ - 0 | $ - 0 |
| A417 | 3.4.11 | Develop and implement a program to inspect, and make all necessary repairs to Interior Roll-up Doors | 12 | Month | $ - 0 | $ - 0 |
Total CLIN 0001AJ (Items A386 Through A417) $ - 0
| FL115 | WILSON AFRC--9500 ARMED FORCES RESERVE DR.--ORLANDO, FL 32827-5226 | |||||
| 3.2 | Preventive Maintenance (PM) Program | |||||
| A418 | 3.2.1 | Develop And Implement Preventive Maintenance Program For HVAC And Refrigeration Systems | 12 | Month | $ - 0 | $ - 0 |
| A419 | 3.2.1.1 | Develop And Implement Seasonal Start-Up and Shutdown for HVAC Systems | 12 | Month | $ - 0 | $ - 0 |
| A420 | 3.2.1.4 | Develop And Implement Preventive Maintenance Program For Exhaust and Transfer Fans | 12 | Month | $ - 0 | $ - 0 |
| A421 | 3.2.1.5 | Develop And Implement Preventive Maintenance Program For Fan Coils and Unit Heaters | 12 | Month | $ - 0 | $ - 0 |
| A422 | 3.2.1.8 | Develop And Implement Preventive Maintenance Program For Variable Air Volume (VAV) and Other Boxes | 12 | Month | $ - 0 | $ - 0 |
| A423 | 3.2.1.12 | Develop And Implement Preventive Maintenance Program For Mini-Splits | 12 | Month | $ - 0 | $ - 0 |
| A424 | 3.2.1.13 | Develop And Implement Preventive Maintenance Program For HVAC Control Systems | 12 | Month | $ - 0 | $ - 0 |
| A425 | 3.2.1.14 | Develop And Implement Preventive Maintenance Program For Thermostats | 12 | Month | $ - 0 | $ - 0 |
| A426 | 3.2.2 | Develop And Implement Preventive Maintenance Program For Security Systems and Equipment | 12 | Month | $ - 0 | $ - 0 |
| A427 | 3.2.3 | Develop And Implement Preventive Maintenance Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A428 | 3.2.3.1 | Develop And Implement Boiler and UPV Seasonal Start-Up and Shutdown | 12 | Month | $ - 0 | $ - 0 |
| A429 | 3.2.3.2 | Develop And Implement Boiler Water Testing and Treatment | 12 | Month | $ - 0 | $ - 0 |
| A430 | 3.2.5 | Develop And Implement Preventive Maintenance Program For Emergency Generator Systems | 12 | Month | $ - 0 | $ - 0 |
| A431 | 3.2.7 | Develop And Implement Preventive Maintenance Program For Built In Refrigeration/Freezer Equipment | 12 | Month | $ - 0 | $ - 0 |
| A432 | 3.2.8 | Develop And Implement Preventive Maintenance Program For Kitchen Type Equipment | 12 | Month | $ - 0 | $ - 0 |
| A433 | 3.2.10.1 | Develop And Implement Preventive Maintenance Program For Plumbing Fixtures | 12 | Month | $ - 0 | $ - 0 |
| A434 | 3.2.10.2 | Develop And Implement Preventive Maintenance Program For Water Heaters | 12 | Month | $ - 0 | $ - 0 |
| A435 | 3.2.10.3 | Develop And Implement Preventive Maintenance Program For Circulating Pumps | 12 | Month | $ - 0 | $ - 0 |
| A436 | 3.2.10.4 | Develop And Implement Preventive Maintenance Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A437 | 3.2.10.6 | Develop And Implement Preventive Maintenance Program For Sump Pumps | 12 | Month | $ - 0 | $ - 0 |
| A438 | 3.2.10.8 | Develop And Implement Preventive Maintenance Program For Roof Drains/Gutters | 12 | Month | $ - 0 | $ - 0 |
| A439 | 3.2.11 | Develop And Implement Preventive Maintenance Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A440 | 3.2.11.1 | Develop And Implement Preventive Maintenance Program For Fire Suppression Systems | 12 | Month | $ - 0 | $ - 0 |
| A441 | 3.2.11.2 | Develop And Implement Preventive Maintenance Program For Mass Notification Boards | 12 | Month | $ - 0 | $ - 0 |
| A442 | 3.2.11.4 | Develop And Implement Preventive Maintenance Program For Kitchen Hoods System | 12 | Month | $ - 0 | $ - 0 |
| A443 | 3.2.11.5 | Develop And Implement Preventive Maintenance Program For Smoke Detectors | 12 | Month | $ - 0 | $ - 0 |
| A444 | 3.2.12 | Develop And Implement Preventive Maintenance Program For Elevator Systems | 12 | Month | $ - 0 | $ - 0 |
| 3.3 | Inspection, Testing, and Certification | |||||
| A445 | 3.3.2 | Develop And Implement an Inspection, Testing, and Certification Program For Backflow Prevention Devices | 12 | Month | $ - 0 | $ - 0 |
| A446 | 3.3.3 | Develop And Implement an Inspection, Testing, and Certification Program For Elevator Systems | 12 | Month | $ - 0 | $ - 0 |
| A447 | 3.3.4 | Develop And Implement an Inspection, Testing, and Certification Program For Boilers and UPVs | 12 | Month | $ - 0 | $ - 0 |
| A448 | 3.3.5 | Develop And Implement an Inspection, Testing, and Certification Program For Fire Protection Systems | 12 | Month | $ - 0 | $ - 0 |
| A449 | 3.3.6 | Develop And Implement an Inspection, Testing, and Certification Program For Ice Machine Equipment | 12 | Month | $ - 0 | $ - 0 |
| 3.4 | Other Recurring Services |