W68SBV63551752
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Construction Project: Ice Harbor Drainage Sump Oil Skimmer
The purpose of this amendment is to incorporate the changes outlined in the summary of changes.
The bid opening date and time remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 31-Jul-2017
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912EF-17-B-0006
X 9B. DATED (SEE ITEM 11)
29-Jun-2017
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
31-Jul-2017
CODE
USAED, WALLA WALLA - CONTRACTING DIV.
HILLARY A. MORGAN
201 N. THIRD AVENUE
WALLA WALLA WA 99362
W912EF 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912EF-17-B-0006
Summary of changes for Amend – 0002
Ice Harbor Drainage Sump Oil Skimmer
CLAUSES
1. Revised Clause 252.236-7001 “CONTRACT DRAWINGS, MAPS, AND SPECIFICATIONS (AUG 2000)” – Added Drawing FIO-016
DRAWINGS
1 Added drawing FIO-016
SECTION 00700 - CONTRACT CLAUSES
The following have been modified:
252.236-7001 CONTRACT DRAWINGS AND SPECIFICATIONS (AUG 2000)
(a) The Government will provide to the Contractor, without charge, one set of contract drawings and specifications, except publications incorporated into the technical provisions by reference, in electronic or paper media as chosen by the Contracting Officer.
(b) The Contractor shall--
(1) Check all drawings furnished immediately upon receipt;
(2) Compare all drawings and verify the figures before laying out the work;
(3) Promptly notify the Contracting Officer of any discrepancies;
(4) Be responsible for any errors that might have been avoided by complying with this paragraph (b); and
(5) Reproduce and print contract drawings and specifications as needed.
(c) In general--
(1) Large-scale drawings shall govern small-scale drawings; and
(2) The Contractor shall follow figures marked on drawings in preference to scale measurements.
(d) Omissions from the drawings or specifications or the misdescription of details of work that are manifestly necessary to carry out the intent of the drawings and specifications, or that are customarily performed, shall not relieve the Contractor from performing such omitted or misdescribed details of the work. The Contractor shall perform such details as if fully and correctly set forth and described in the drawings and specifications.
(e) The work shall conform to the specifications and the contract drawings identified on the following index of drawings:
Drawing Number
Sheet Number
ICE HARBOR DRAINAGE SUMP OIL SKIMMER
Revision Number
Date
GENERAL
IHG-1-0-1/514 G-001 COVER SHEET AND LOCATION MAPS
IHG-1-0-1/515 G-002 INDEX TO DRAWINGS
IHG-1-0-1/516 G-101 GENERAL - POWERHOUSE - KEY PLAN
STRUCTURAL
IHP-1-5-17/1 S-101 CORE DRILL PLAN
IHP-1-5-17/2 S-501 LIFTING LUG - DETAILS
MECHANICAL
IHP-1-3-17/9 M-101
MECHANICAL EQUIPMENT - DRAINAGE SUMP EL
335.5 PLAN
IHP-1-3-17/10 M-102
DIFFUSER, BAFFLES, AND PIPING - DRAINAGE
SUMP EL 330.0 PLAN
IHP-1-3-17/11 M-301
DIFFUSER, BAFFLES, AND PIPING - DRAINAGE
SUMP SECTIONS
IHP-1-3-17/12 M-302
MECHANICAL EQUIPMENT - ARRANGEMENT -
AND PIPING SCHEMATIC
IHP-1-3-17/13 M-303
OIL SKIMMER COLLECTION TANK - MECHANICAL
EQUIPMENT ARRANGE- - MENT AND PIPING
SCHEMATIC
IHP-1-3-17/14 M-401 DECANTER TANK ASSEMBLY - DETAILS
IHP-1-3-17/15 M-402
OIL SKIMMER SUPPORT STAND - ASSEMBLY
VIEWS
IHP-1-3-17/16 M-403 OIL SKIMMER SUPPORT STAND - DETAILS 1
IHP-1-3-17/17 M-404 OIL SKIMMER SUPPORT STAND - DETAILS 2
IHP-1-3-17/18 M-405 OIL SKIMMER SUPPORT STAND - DETAILS 3
IHP-1-3-17/25 M-406 DRAINAGE SUMP PIPING - DETAILS
IHP-1-3-17/19 M-501 BAFFLE - STANDARD - DETAILS I
IHP-1-3-17/20 M-502 BAFFELE - EXTENDED - DETAILS II
IHP-1-3-17/21 M-503 BAFFLE - EXTENDED MODIFIED - DETAILS III
IHP-1-3-17/22 M-504
BAFFLE - ELONGATED & CONTRACTED - DETAILS
IV
IHP-1-3-17/23 M-505 DIFFUSER - BOTTOM - DETAILS V
IHP-1-3-17/24 M-506 COVER & DIFFUSER PLATES - DETAILS VI
IHP-1-3-17/26 M-901 PHOTOGRAPHS - SUMP ACCESS EL 335.5
ELECTRICAL
IHP-1-6-17/29 E-001 LEGEND AND SYMBOLS
IHP-1-6-17/30 E-101
EQUIPMENT ARRAGEMENT - DRAINAGE SUMP EL
IHP-1-6-17/31 E-102
POWER FEED PLAN - DRAINAGE PUMP GALLERY
EL 349.5
IHP-1-6-17/32 E-201
CQO7 ADDITIONS FOR OIL SKIMMER - DRAINAGE
PUMP GALLERY EL 349.5
IHP-1-6-17/33 E-202 ELECTRICAL EQUIPMENT LAYOUT
IHP-1-6-17/34 E-501 CONTROL EQUIPMENT DETAIL
IHP-1-6-17/36 E-601 LOGIC DIAGRAM
IHP-1-6-17/37 E-602 CABLE AND CONDUIT SCHEDULE
FOR INFORMATION ONLY (FIO)
The Government does not warrant the accuracy of the FIO drawings. The Government recommends that the Contractor verify the accuracy of FIO drawings.
IHP-1-4-0/2 FIO-001
POWERHOUSE - CONCRETE - TRANSVERSE
SECTION - ERECTION BAY AND SERVICE BAY
IHP-1-4-3/7 FIO-002
POWERHOUSE - CONCRETE OUTLINE - ERECTION
BAY - SUMPS - PLANS AND SECTIONS
IHP-1.1-3-9/26 FIO-003
POWERHOUSE - EXPOSED PIPING - SPIRAL CASE &
DRAFT TUBE - DRAIN LINES
IHP-9-3-9/1 FIO-004
POWERHOUSE - PIPING DIAGRAM -
UNWATERING AND DRAINAGE - SUMP PUMPS
IHP-1-3-17/3 FIO-005 MECHANICAL - NEW WORK - DRAINAGE PUMPS
IHP-1-4-5/2 FIO-006
POWERHOUSE - CONCRETE OUTLINE - SOUTH
FISH LADDER - PLAN AT EL. 335.00
IHP-1-3-8/5 FIO-007
POWERHOUSE - MECHANICAL - ERECTION AND
SERVICE BAYS - SUBSTRUCTURE - PLANS AND
SECTION
IHP-1-3-8/6 FIO-008
POWERHOUSE - MECHANICAL - ERECTION AND
SERVICE BAY - SUB- - STRUCTURE - SECTIONS
AND DETAILS
IHP-1-4-5/18 FIO-009
POWERHOUSE - REINFOCEMENT - SOUTH FISH
ENTRANCE - SLAB AT EL. 332 - NORTH PART
IHP-1.1-6-1D1/2 FIO-010
POWERHOUSE - ELECTRICAL - EMBEDDED
CONDUIT & GROUNDING - SERVICE & ERECTION
BAYS - EL. 349.5
IHP-1-3-17/2 FIO-011
UNWATERING AND DRAINAGE - PUMPS
REPLACEMENT - MECHANICAL - NEW WORK - EL.
IHP-1.1-3-9/6 FIO-012
POWERHOUSE - EXPOSED PIPING - UNWATERING
AND DRAINAGE - PUMPS AND PIPING
IHP-1.1-6-7AO/1 FIO-013
POWERHOUSE - EXPOSED PIPING - GROUNDING
SYSTEM - SCHEMATIC DIAGRAM
IHP-1.1-6-7AO/1 FIO-014 CQ07 ELEVATION VIEW - COMPARTMENT 2E
IHP-1.1-6-7AO/1 FIO-015 CQ07 SCHEDULE
IHP-1-6-1/23 FIO-016 CONTROL ROOM
(End of drawing list) (End of Clause)
Microstation V8 is the only CAD system used by Walla Walla District. Contract drawings created on CAD in Microstation V8 will be available in electronic form for use by the Contractor. No For Information Only drawings are available on CAD. The Contractor assumes all risks associated in using electronic CAD drawings. The contract drawings shall govern if there are any discrepancies between the electronic copy and the contract drawing. The Contractor shall promptly notify the Contracting Officer of any discrepancies. The Government will not be responsible to correct the electronic CAD drawing. If contract modifications are issued, the associated electronic CAD drawings will not be available to the Contractor. Electronic copies of CAD drawings are only available in Bentley MicroStation format. The Government will provide the files on CD ROM.