Amendment_0003_-_KC46_Fuselage_Trainer_-_Plans.pdf

PDF 2 MB Posted

Attached to
KC-46A Addition/Alteration to Bldg. 3209 for Fuselage Trainer Federal contract opportunity
Solicitation number
W912DS18B0019
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

Amendment 0003 Plans

View the file

Other files for this federal contract opportunity

Other files attached to KC-46A Addition/Alteration to Bldg. 3209 for Fuselage Trainer, newest first.
File Type Posted
Bid_Abstract-W912DS18B0019.pdf PDF
Amendment_0003_-_KC46_Fuselage_Trainer_-_Specs.pdf PDF
W912DS18B0019-0003.pdf PDF
W912DS18B0019-0002_Revised.pdf PDF
Amendment_0002_-_FuT_Specs.pdf PDF
Amendment_0002_-_FuT_Plans.pdf PDF
W912DS18B0019-0002.pdf PDF
W912DS18B0019-0001.pdf PDF
Site_Visit_Sign-In_4_SEP_18_(Fus_Trainer,_Fuel_Hydrants,_Fac_for_Mx).pdf PDF
Package_1_-_KC46_Fuselage_Trainer_-_Plans.pdf PDF
Appendix_B_-_Geotechnical_Report.pdf PDF
Package_3_-_KC46_Fuselage_Trainer_-_SID.pdf PDF
W912DS18B0019.pdf PDF
Package_4-_KC46_Fuselage_Trainer_-_FFE.pdf PDF
Appendix_A_-_Bldg_3209_As-Builds.pdf PDF
Package_2_-_KC46_Fuselage_Trainer_-_Specifications.pdf PDF
Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Communication CCTV JUNCTION BOX SHALL BE

MOUNTED ON THE EXTERIOR OF THE BUILDING

AND CONDUIT RUN UP FACE THAN PENETRATE

INTO THE BUILDING TO RUN TO COMM ROOM

AD

D

ED

N

O

TE

S

-S ep t-e3endtes Line e3endtes Polygon e3endtes Polygon e3endtes Line

G

T V

T V

G G GMGR

G

G

G

G

G

G

G

G

G

J

TV

F F

F

WS WS WS WS WS WS

WS WS WS WS WS WS

WS WS WS WS WS WS

G

J

RC

RC

RC RC RC

G

J J

J

J

J J

G

G

L V

J

J

J J

PLAN NORTH

TIER

#1

TIER

#2

E

F

TP1

G

H

T-1HLP-1 LDP-1

LP-1

CP-1

BK-1

BRIEFING 1

CLASS RM /CBT

EXISTING MECH

RM

EXISTING STAIRS

INST. OFFICE

MAINT OFFICE

0A

DSS-2

FACP

DSS-1

CL CREW OFFICE

BRIEFING 2

ELEC RM

MENS RESTROOM

116 WOMENS

RESTROOM

BREAK ROOM

EXISTING

ELEVATOR

F

E

G

H

EF-1

FU-1

WH-1

SS-1

CP-1

LP-1- 1,3,5

LP-1-

6,8,10

LP-1- 9

LP-1- 7

LP-1- 13

LP-1- 15

LP-1- 2

LP-1- 4

N.I.C.

DDC

EP-101

LP-1- 11

LP-1-

12,14,16

LP-1- 24

LP-1- 22

LP-1- 18

LP-1- 20

BK-1- 2 BK-1- 17

BK-1- 16

BK-1- 12

BK-1- 10

BK-1-

3,5,7

BK-1- 4

BK-1- 6

BK-1- 18

BK-1- 1

BK-1- 19

MH-1-

7,9,11VESDA

PANEL

RELEASING

PANEL

GENERAL NOTES

1. SEE SHTS. E-001 AND E-002 FOR ELECTRICAL LEGEND AND GENERAL NOTES.

2. PROVIDE LABELS FOR ALL OUTLETS DENOTING PANEL AND CKT #.

3. ALL MOTOR STARTERS/COMBINATION MOTOR STARTERS (ACROSS THE LINE, VFDs, etc) REQUIRED FOR THE MECHANICAL HVAC EQUIPMENT SHALL BE PROVIDED UNDER DIVISION 23 (MECHANICAL SUBCONTRACTOR), BUT SHALL BE COORDINATED AND INSTALLED UNDER DIVISION 26 (BY THE ELECTRICAL SUBCONTRACTOR.

SEE MECHANICAL HVAC SCHEDULES FOR REQUIREMENTS.

4. SEE MECHANICAL SCHEDULES FOR HVAC EQUIPMENT DISCONNECTS TO BE PROVIDED UNDER DIVISION 23, AND

INSTALLED UNDER DIVISION 26.

5. ALL BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR.

6. COORINATE THE DISCONNECT LOCATIONS FOR MECHANICAL AND PLUMBING EQUIPMENT WITH THE MECHANICAL SUBCONTRACTOR. PROVIDE ANY REQUIRED UNISTRUCT SUPPORTS FOR MOUNTING OF THE

DISCONNECTS.

7. PROVIDE UNISTRUCT TYPE SUPPORTS FOR MOUNTING OF PANELBOARD AND DISCONNECTS ON THE TIER 2

ROOF AREA.

DRAWING KEY NOTES

1. PROVIDE JUNCTION BOXES FOR RACK MOUNTED RECEPTACLES. (1) QUAD 120V/20A. RACK MOUNTED RECEPTACLES ALSO PROVIDED BY CONTRACTOR.

2. PROVIDE JUNCTION BOXES FOR RACK MOUNTED RECEPTACLES (1) NEMA L6-20R 208V/1/20A. RACK MOUNTED RECEPTACLES ALSO PROVIDED BY CONTRACTOR.

3. BRANCH CIRCUIT FOR FUTURE CARD ACCESS SYSTEM (CAS) CONTROL PANEL(S).

4. MAIN FEEDER UNDERFLOOR DUCT (POWER/DATA COMPARTMENTS) 6 1/2" WIDE X 2 1/2" DEEP FOR FLUSH FLOOR INSTALLATION. UNDERFLOOR DUCT SHALL HAVE SEPARATE POWER AND COMMUNICATIONS CABLE SECTIONS FOR ROUTING OF ALL POWER BRANCH CIRCUIT CONDUCTORS AND COMMUNICATIONS CABLES.

5. TWO (2) 3 1/8" WIDE UNDERFLOOR BRANCH DUCT (POWER/DATA COMPARTMENTS) FOR FLUSH FLOOR WIREWAY DEVICES.

6. CONTRACTOR SHALL MODIFY (SAW CUT TRENCH, ETC) EXISTING SLAB FOR INSTALLATION OF UNDERFLOOR DUCT FOR BOTH MAIN FEEDER DUCT TRENCH AND FOR BRANCH DUCTS. PROVIDE CONCRETE FOR THE TRENCHED AREAS AS REQUIRED BY THE MANUFACTURER OF THE UNDERFLOOR DUCT SYSTEMS, AND AS PER SECTION 03300. POROUS/FORMFLOW CONCRETE MAY BE REQUIRED TO PROVIDE FOR A WORKMANSHIP TYPE PRODUCT.

7. BRANCH CIRCUITS FOR WIREWAY SYSTEM SHALL BE ROUTED THROUGH THE FLOOR WIREWAY IN THE POWER COMPARTMENT OF THE DUAL UNDERFLOOR RACEWAY. ALL BRANCH CONDUCTORS SHALL BE #10 AWG FOR THE ENTIRE ROUTE BACK TO THE PANELBOARD.

8. THE INDOOR UNITS (DSS-X) ARE CIRCUITED FROM THE CORRESPONDING OUTDOOR UNITS (DCU-X).

9. PROVIDE A UNDERFLOOR DUCT RISER SECTION WITHIN THE GWB WALL. TRANSITION TO CONDUIT FOR THE POWER COMPARTMENT TO ROUTE BRANCH CIRCUITS TO INDICATED PANELBOARD. PROVIDE AN ACCESS PANEL IN BOTTOM OF WALL FOR ACCESS TO THE RISER SECTION. COORDINATE WITH THE MANUFACTURER OF THE UNDERFLOOR DUCT FOR ALL REQUIRED FITTINGS AND ACCESSORIES FOR A COMPLETE INSTALLATION.

10. SAWCUT AND CONCRETE PATCH EXISTING CONCRETE FLOOR FOR INSTALLATION OF FLOOR BOX AND ASSOCIATED CONDUIT. TYPICAL FOR ALL

FLUSH FLOOR MOUNTED BOXES.

KEY PLAN

SEE GENERAL NOTE 7

(TYP)

E

F

TP1

G

H

F

E

G

H

DCU-1

CU-1

DCU-2

AHU-1

EXIST SWBD

MH-1

EXIST TRANS

CP-1- 1,3

LDP-1-

8,10

MH-1-

2,4,6

MH-1-

1,3,5

T-2

200A

4#10, 3/4"C

4#10, 3/4"C

NITROGEN

GENERATOR

BK-1- 20

BK-1- 22

3#10, 3/4"C

GG

CP-1

CP-1- 13 CP-1- 14

CP-1- 16 CP-1- 10

CP-1- 15

CP-1- 12

CP-1- 5,7

CP-1- 2,4

CP-1- 6

CP-1- 8

CP-1- 9

CP-1- 11

VESDA

PANEL

RELEASING

PANEL

FACP

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

LI

C

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

C la rif ic at io n of u nd er fl oo r du ct

D E

S C

R

IP

T

IO

N

EP-101

T

IE

R

P O

W E

R P

LA

N

S

JO

IN

T B

A S

E M

C G

U

IR

E D

IX

L

A K

E H

U R

S T

JB

M D

L)

N E

W Y

O R

K D

IS

T

R

IC

T

F

E D

E R

A L

P L

A Z

A

N E

W Y

O R

K , N

Y

C O

N T

R A

C T

O R

N A

M E

S T

R E

E T

A D

D R

E S

S C

IT

Y

S

T A

T E

Z

IP

ID

D e si gn e r

A u th o r

C h e ck e r

M M

M M

M M

M M

M Y

Y Y

Y

W

-X

X -X

-X X

X X

W

-X

X -X

-X X

X X

O P

T

IO

N A

L F

IE

LD

O

P T

IO

N

A L

F

IE

LD

T

IT

L

E

O P

T

IO

N A

L F

IE

LD

T

IT

L E

K C

F

U S

E L

A G

E T

R A

IN

E

R

P R

O

JE

C T

O P

T

IO

N A

L F

IE

L

D

-S e pt

-1

1/8" = 1'-0"1 TIER 2 POWER PLAN

0' 4' 8' 16' 32'

SCALE: 1/8" = 1'-0"

1/8" = 1'-0"3 TIER 2 ROOF POWER PLAN

1/4" = 1'-0"4 ENLARGED COMM ROOM PLAN

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EP-603

PA

N

EL

BO

AR

D

S C

H

ED

U

LE

S -2

JO

IN

T

BA

SE

M

C G

U

IR

E D

IX

L

AK

EH

U R

ST

(J

B M

D L)

N

EW

Y O

R K

D

IS

TR

IC

T

F

ED

ER

AL

P

LA

ZA

, N

EW

Y

O R

K, N

Y

2 7

C O

N

TR

AC

TO

R N

AM

E

ST

R

EE

T

AD

D

R

ES

S C

IT

Y, S

TA

TE

Z

IP

ID

D es ig ne r

Au th or

C he ck er

M M

M M

M M

M M

M Y

YY

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

O

PT

IO

N

AL

F

IE

LD

O

PT

IO

N

AL

F

IE

LD

T

IT

LE

O

PT

IO

N

AL

F

IE

LD

T

IT

LE

KC

FU

SE

LA

G E

TR

AI

N E R

PR

O

JE

C

T

O

PT

IO

N

AL

F

IE

LD

Notes: 1. Provide Lockable Circuit Breaker, Red in Color.

Total Est. Demand Current: 31 A

Total Conn. Current: 37 A Equipment User 4000 VA 2400 VA Total Est. Demand: 11164 VA Receptacle 6980 VA 6980 VA Total Conn. Load: 13210 VA

HVAC 2230 VA 1784 VA

Load Classification Connected Load Estimated Demand Panel Totals

Total Amps: 42 A 42 A 29 A Total Load: 4855 VA 4855 VA 3500 VA

41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 Spare 20 A 1 0 VA 26 23 Spare 20 A 1 0 VA 24 21 Spare 20 A 1 0 VA 22 19 Spare 20 A 1 0 VA 20 17 Spare 20 A 1 0 VA 18 15 Receptacles Perimeter Wall 20 A 1 540 VA 600 VA 1 20 A Releasing Panel (See Note 1) 16 13 Receptacles Perimeter Wall 20 A 1 540 VA 200 VA 1 20 A VESDA Panel (See Note 1) 14

11 FS RACK 20 A 1 1000... 500 VA 1 20 A FUTURE CARD ACCESS SYSTEM PANELS 12

9 FS RACK 20 A 1 1000... 600 VA 1 20 A FACP Panel (See Note 1) 10

7 -- -- -- 1000... 1000... 1 20 A COMM SQUADRON RACK 8

5 FS RACK 20 A 2 1000... 1000... 1 20 A COMM SQUADRON RACK 6

3 -- -- -- 1115... 1000... -- -- -- 4

1 DCU-2, DSS-2 20 A 2 1115... 1000... 2 20 A COMM SQUADRON RACK 2

CKT Load Name Trip Poles A B C Poles Trip Load Name CKT

Notes:

Enclosure: Type 1 Main Rating: 100 A Mounting: Surface 4 MCB Rating: 100 A

Supply From: LDP-1 3 Mains Type: MCB Location: COMM ROOM 114 120/208 Wye A.I.C. Rating: 22 KAIC

Branch Panel: CP-1

Notes: 1. Provide Lockable Circuit Breaker, Red in Color.

Total Est. Demand Current: 58 A

Total Conn. Current: 66 A Plumbing 4200 VA 3360 VA Total Est. Demand: 20780 VA Receptacle 8520 VA 8520 VA Total Conn. Load: 23845 VA

HVAC 11125 VA 8900 VA

Load Classification Connected Load Estimated Demand Panel Totals

Total Amps: 66 A 73 A 61 A Total Load: 7860 VA 8725 VA 7260 VA

41 42 39 40 37 38 35 36 33 Spare 20 A 1 0 VA 34 31 Spare 20 A 1 0 VA 32 29 Spare 20 A 1 0 VA 30 27 Spare 20 A 1 0 VA 28 25 Fuselage Fire Sys Air Compressor (See Note... 30 A 1 2880... 26 23 Fuselage Fire Sys Release Panel (See Note 1) 20 A 1 600 VA 1800... 1 20 A Heat Trace Cable Piping 24 21 Fuselage Nitrogen Generator (See Note 1) 20 A 1 1920... 685 VA 1 20 A Nitrogen Generator Tier 2 Roof (See Note 1) 22 19 DDC Control Panel Mech Rm 20 A 1 100 VA 360 VA 1 20 A Receptacles Tier 2 Roof 20 17 Receptacles Corridor 20 A 1 540 VA 240 VA 1 20 A Receptacle Condensate Pump CP-1 Mech Rm 18 15 -- -- -- 2100... 540 VA 1 20 A Receptacles Elec and Mech Rms 16 13 UC-1 Utility Air Compressor Fuselage Trainer 30 A 2 2100... 500 VA 1 20 A Emergency Eye Wash Fuselage Trainer 14 11 BA-1 Breathing Air Purifier Fuselage Trainer 20 A 1 1920... 900 VA 1 20 A Receptacles Restrooms and Janitor's Closet 12 9 AD-1 Air Dryer for Compressor Fuselage... 20 A 1 1920... 100 VA 1 20 A Automatic Sensors Restrooms 10 7 Receptacles Tables Break Rm 20 A 1 360 VA 360 VA 1 20 A Receptacles Fuselage Trainer 8 5 Receptacles Countertop Break Rm 20 A 1 360 VA 900 VA 1 20 A Receptacle Microwave Break Rm 6 3 Receptacles Countertop Break Rm 20 A 1 360 VA 1100... 1 20 A Receptacle Refrigerator Break Rm 4 1 WH-1 Mech Rm 20 A 1 600 VA 600 VA 1 20 A EF-1 Corridor 2

CKT Load Name Trip Poles A B C Poles Trip Load Name CKT

Notes:

Enclosure: Type 1 Main Rating:

Mounting: Surface 4 MCB Rating: 100 A

Supply From: LDP-1 3 Mains Type: MCB Location: ELEC RM 104 120/208 Wye A.I.C. Rating:

Branch Panel: BK-1

Notes:

Total Est. Demand Current: 12 A

Equipment User 2880 VA 1728 VA Total Conn. Current: 17 A Receptacle 540 VA 540 VA Total Est. Demand: 2977 VA Lighting - Exterior 25 VA 25 VA Total Conn. Load: 4125 VA Lighting 727 VA 727 VA Load Classification Connected Load Estimated Demand Panel Totals

Total Amps: 20 A 14 A Total Load: 2394 VA 1731 VA

23 24 21 22 19 20 17 18 15 Spare 20 A 1 0 VA 16 13 Spare 20 A 1 0 VA 0 VA 14 11 Spare 20 A 1 0 VA 12 9 Spare 20 A 1 0 VA 0 VA 10 7 Spare 20 A 1 0 VA 8 5 Exterior Lighting 20 A 1 450 VA 0 VA 6 3 -- -- -- 1440 VA 304 VA Lighting 4 1 K-Loader 30 A 2 1440 VA 1440 VA Receptacle 2

CKT Load Name Trip Poles A B Load Name CKT

Notes: Main breaker trip rating shall be 60 AT.

Enclosure: Main Rating: 100 A Mounting: Surface 3 MCB Rating: 100 A

Supply From: T-3 1 Mains Type: MCB Location: 120/240 Single A.I.C. Rating: 10 KAIC

Branch Panel: LP-ST

GENERAL NOTES:

1. ALL BREAKER POSITONS NOT IDENTIFIED ARE BREAKER SPACES.

/9

/2

PA

N

EL

B

R

EA

KE

R

R

EV

IS

IO

N e3enmrt3 Polygon

2& 3

R

EV

IS

IE

D

N O

TE

SE

P e3endtes

PC

G

W P

G

W P

G

W P

P Q R S

S

WF

WP

MT 13'-0" AFF

LP-ST- 5

LP-ST- 4

WF

(TYP)

GENERAL NOTES

1. SEE SHTS. E-001 AND E-002 FOR ELECTRICAL LEGEND AND GENERAL NOTES.

2. SEE SHT. EL-501 FOR LIGHTING FIXTURE SCHEDULE.

DRAWING KEY NOTES

1. PROVIDE NEMA L6-30R, 240V/1/30A, NEMA 4X RECEPTACLE & 3 #10 AWG-3/4C FOR THE K-LOADER

2. PROVIDE UNISTRUT TYPE SUPPORT SYSTEM FOR PANELBOARD, TRANSFORMER AND

DISCONNECT. MOUNT 3'-0" AFG.

KEY PLAN

P Q R S

WPLP-ST

LP-ST- 1,3

LP-ST- 2

T-3

100A

NEMA 3R

US Army Corps of Engineers ®

SHEET

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

EL-103

C O

VE

R

E D S

T O R

AG

E

LI

G

H

TI

N G

A N

D P

O W

E R

FL

O O

R P

L A N

S

JO

IN

T

BA

SE

M

C G

U

IR

E D

IX

L

AK

EH

U R

ST

(J

B M

D L)

N

EW

Y O

R K

D

IS

TR

IC

T

F

ED

ER

AL

P

LA

ZA

, N

EW

Y

O R

K, N

Y

2 7

C O

N

TR

AC

TO

R N

AM

E

ST

R

EE

T

AD

D

R

ES

S C

IT

Y, S

TA

TE

Z

IP

ID

D es ig ne r

Au th or

C he ck er

M M

M M

M M

M M

M Y

YY

Y

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

O

PT

IO

N

AL

F

IE

LD

O

PT

IO

N

AL

F

IE

LD

T

IT

LE

O

PT

IO

N

AL

F

IE

LD

T

IT

LE

KC

FU

SE

LA

G E

TR

AI

N E R

PR

O

JE

C

T

O

PT

IO

N

AL

F

IE

LD

1/8" = 1'-0"1 COVERED STORAGE LIGHTING PLAN

MT 18'-6" AFG

MT 12'-6" AFG

0' 4' 8' 16' 32'

SCALE: 1/8" = 1'-0"

1/8" = 1'-0"3 COVERED STORAGE POWER PLAN

MT 3'-0" AFG1

MT 17'-6" AFG

MT 12'-6" AFG

/9

/2

N O

TE

R

EV

IS

IO

N e3enmrt3

File details come from the government source that posted it.