Appendix_G_-_Solid_Waste_Mgmt_Plan.pdf
PDF 625 KB Posted
- Attached to
- Replace M Plant Cooling Water System, Thule Air Base, Greenland Federal contract opportunity
- Solicitation number
- W912DS-14-B-0018
About this file
APPENDIX G
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CDRL CEV-15E Solid Waste Management Plan
Thule Air Base, Greenland 1/26
CDRL CEV-15E
SOLID WASTE MANAGEMENT PLAN
Thule Air Base, Greenland
Final FY-12
OPR: GREENLAND CONTRACTORS
Chief of Environmental Engineering DSN 629-3840 ext. 2698 Contract No. FA2523-05-C-9001 Supersedes CDRL CEV-15E signed 16 feb 11
Thule Air Base, Greenland 3/26
TABLE OF CONTENTS
1 LETTER OF INSTRUCTION
1.1 Security and administrative instructions
2 GENERAL
2.1 Purpose
2.2 Scope
2.3 Regulatory Overview
3 ORGANIZATIONAL ROLES AND RESPONSIBILITIES
3.1 Commander, 821 ABG/CC
3.2 Danish Liaison Officer, DLO
3.3 Environmental Engineering, GC/EE
3.4 CE Operations & Maintenance, GC/CEOM
3.5 GC/LGDRM
3.6 CE O & M/Utilities & Facilities Maintenance, GC/OMUFM
3.7 General Personnel
4 SOLID WASTE STREAMS
4.1 Batteries
4.2 Toner Cartridges, Toner and Developer
4.3 Scrap Metal
4.4 Filters
4.5 Liquid Wastes
4.6 Paint Cans
4.7 Rags
4.8 Sweeping Compound (Absorbant)
4.9 Building Debris
4.10 LED Light bulbs
4.11 Special generated waste
4.11.1 UXO areas
4.11.2 Arctic Foxes
4.11.3 Medical Waste
5 UNACCEPTABLE WASTE
5.1 Hazardous Waste
5.2 Infectious Medical Waste
5.3 Polychlorinated Biphenyl (PCB)
5.4 Asbestos Waste
5.5 Waste Unsuitable for the Sanitary Landfill
5.5 Solids from Sewage
6 RECYCLING AND REUSE
6.1 Recycling
6.2 Solid waste reduction strategy
7 LANDFILL OPERATIONS
7.1 Requirements
7.2 Site security
7.3 Sections
7.4 Cover
7.5 Disposal records
Thule Air Base, Greenland 4/26
7.6 Inspections
7.7 Vector Control
7.8 Methane Monitoring
7.9 Biodegradation
7.10 Personnel training
APPENDIX 1: DEFINITIONS
APPENDIX 2: ABBREVIATIONS AND ACRONYMS USED
APPENDIX 3: RECYCLING PROGRAM DESCOPE DCR DOCUMENTATION
APPENDIX 4: INSPECTION CHECK LIST FOR SANITARY LANDFILL
APPENDIX 5: REFERENCES
APPENDIX 6: DISTRIBUTION LIST
APPENDIX 7: REVIEW COMMENTS
APPENDIX 8: QUALIFIED RECYCLING PROGRAM BUSINESS PLAN
Thule Air Base, Greenland 5/26
1 LETTER OF INSTRUCTION
1.1 Security and administrative instructions
Title
: The title of this document is “Solid Waste Management Plan”. The acronym, SWMP, will be used throughout the entire document.
Classification
: The document is unclassified.
Responsibilities
: Greenland Contractors, Environmental Engineering (GC/EE) is the office of primary responsibility for developing and maintaining the plan. The instructions given in this plan are applicable to all organizations and tenant units at Thule AB. Organizations are authorized to extract and reproduce those sections of the plan that are essential in the accomplishment of necessary planning and in the preparation of supporting documents and reports.
Reviews/changes
: This plan is updated annually IAW the CDRL and distributed accordingly. A draft is submitted to 21 CES/CEAN by 1 Nov for review. Review comments, if any, will be provided within 60 days. Review comments received will be incorporated in the final version of the plan within 30 days; thereafter the document will be submitted to 821 ABG/CC for signature.
The signed plan will then be submitted as the Final edition.
Further, the plan is subject to change if any of the applicable laws, regulations, or requirements is altered.
Distribution
APPENDIX
: The plan will be distributed to the organizations listed in the distribution list,
6. For all GC organizations, the electronic version is available on the GC Intranet.
Thule Air Base, Greenland 6/26
2 GENERAL
2.1 Purpose
The purpose of the plan is to ensure that documented guidance regarding solid waste management is available to all installation personnel.
The goal is to achieve a full state of awareness throughout the installation and in this way enable personnel to:
- Be familiar with solid waste procedures including related regulatory requirements.
- Develop related planning documents (e.g. action plans), which will bring the installation into full compliance with regulatory requirements.
- Maintain a safe environment.
- Minimize future solid waste generation at Thule AB.
2.2 Scope
The provisions of the SWMP apply throughout Thule AB and to all personnel. Certain responsibilities are specifically assigned to selected individuals identified in the plan. Although the contents of the SWMP are limited to solid waste management, related plans include:
- Hazardous Waste Management Plan CDRL CEV-15B
- Asbestos Management Plan CDRL CEV-15A
- Spill Prevention And Response Plan CDRL CEV-15C
- Slug (Wastewater) Management Plan CDRL CEV-15J
- Storm Water Management Plan CDRL CEV-15G
- PCB Replacement Plan, CDRL CEV-12
- Qualified Recycling Program Business Plan (Appendix 8)
Further, reference is made to the Final Landfill Assessment and Operations Management Plan, prepared for 821 ABG in December 2005.
2.3 Regulatory Overview
In accordance with USAF policy, Thule AB is required to comply with the following public laws and their respective regulations:
US State Laws: Not applicable
USAF: AFI 32-7042, Waste Management, 21 April 2009, Chapter 3, para 3.6.3 Final Governing Standards, Chapter 7
Thule AB: EPC decisions.
Host Country: Memorandum of Understanding (MOU). “An Agreement Concerning the
Disposal of United States Salvage, Surplus or Excess Equipment and Supplies at USAF Aerospace Defense Command Bases and Sites in Greenland”, dated 29 June 1976 and 1987 amendment.
Thule Air Base, Greenland 7/26
3 ORGANIZATIONAL ROLES AND RESPONSIBILITIES
The duties and responsibilities of all organizations and personnel involved in solid waste management, or those otherwise involved in the implementation of the SWMP, are outlined below.
3.1 Commander, 821 ABG/CC
The Installation Commander has the overall responsibility for the revision and coordination of solid waste management at Thule AB. The responsibility is implemented through the base Environmental Protection Committee (EPC), of which the Installation Commander is the chairperson.
3.2 Danish Liaison Officer, DLO
The Danish Liaison Officer serves as the official representative of Denmark and the Greenland Home Rule at Thule AB in environmental issues.
3.3 Environmental Engineering, GC/EE
It is the responsibility of GC/EE to review and update the SWMP annually. The plan must be coordinated with relevant organizations prior to final approval by the Installation Commander.
3.4 CE Operations & Maintenance, GC/CEOM
The Chief of CE Operations & Maintenance has the overall responsibility for collection, transportation, and disposal of solid waste at Thule AB.
The Supervisor of Pavements & Grounds, GC/OMPG, is responsible for the daily management of the sanitary landfill, and must ensure that the operator assigned to the dump truck performs all assigned duties in compliance with applicable publications, to include safety and good sanitary practices. Personnel collecting solid waste storage containers (dumpsters) are responsible for inspecting the contents. If items are improperly disposed of, the Pavements & Grounds Supervisor must be notified immediately. The operator of the dump truck will immediately clean up any waste caused by the operator’s operations.
3.5 GC/LGDRM
Logistics Defense Reutilization & Marketing (GC/LGDRM) is responsible for proper disposal of batteries, developer, scrap metal, paint cans, rags and other unwanted wastes. For waste minimization and recycling purposes, household batteries must be collected once a year from the battery disposal units placed throughout Thule AB. The batteries must be sorted prior to disposal.
The LGDRM will keep a record of all recyclable materials, which are sent out through the
LGDRM.
Most toner cartridges can be disposed through the American Post Office (APO). Cartridges that cannot be disposed through the APO for any reason must be turned in to the LGDRM.
3.6 CE O & M/Utilities & Facilities Maintenance, GC/OMUFM
Utilities will keep a record of used oil burned for energy recovery at the K-Plant. The record is kept for quarterly metrics reported to AFSPC.
Thule Air Base, Greenland 8/26
3.7 General Personnel
All personnel at Thule AB contribute to the generation of solid waste. It is the responsibility of each person to ensure that general household waste and garbage is disposed of in the solid waste dumpsters. Information on proper solid waste disposal is provided via information slides, in both Danish and English, on the local TV information channels. Signs with disposal guidelines are posted on every solid waste dumpster.
Thule Air Base, Greenland 9/26
4 SOLID WASTE STREAMS
Solid wastes, other than household waste, are produced base-wide. The types and proper dis-posal methods is stated for each group.
At Thule AB the storage dumpsters for solid waste are leakproof, waterproof and verminproof.
The solid waste dumpsters are stored on a firm, level, well-drained surface. The dumpsters are placed in proximity of the dorms and shops for easy accessibility for users and waste collectors.
It is not permitted to park vehicles in a fashion that restrict waste collector access to the container.
Dumpster currently in use at TAB
4.1 Batteries
At Thule AB, a battery collection system for base personnel has been established. Battery disposal units are placed at the following locations:
• GC Post Office, Bldg. #201
• Greenland TelePost, Bldg. #101
• North Star Inn, Bldg. #100
• American Post Office (APO), Bldg. #211
• Base Exchange (BX), Bldg. #251
The units consist of only one box for all types of household batteries, and they are marked "Battery Disposal" to make the box visible. GC/EE and the LGDRM are responsible for the battery units. If collection boxes need emptying, the LGDRM can be contacted at ext. 2785.
Dry batteries must be collected in the individual shops and turned in to the LGDRM for sorting and proper disposal. Batteries, which cannot be recycled, will be managed in accordance with the HWMP, CDRL CEV-15B.
GC/EE will provide containers for battery disposal for dorms on request.
4.2 Toner Cartridges, Toner and Developer
Toner cartridges for printers are generally reusable and returned to the USA for recycling via the APO. The used toner cartridges must be packed in the original packaging. A self-adhesive shipping label is included in the original package. This shipping label is placed on the outside of the box. The cartridges (accumulated in packs of 10) are then turned in to the American Post Office (APO), Bldg. #211.
Surplus powder toners from photocopiers were analytically tested for hazardous characteristics and were found non-hazardous. The powder can therefore be disposed of at the landfill.
Developer is turned in through LGDRM.
Thule Air Base, Greenland 10/26
4.3 Scrap Metal
All copper cable must be collected and turned in to the local LGDRM. The cables are sent out for recycling. Other scrap metal is not recycled due to financial restrictions (Appendix 3). Thin copper wires are accepted for recycling, but their collection is not mandatory.
A container for the disposal of cable scrap is located in building 801.
Brass shavings and turnings are collected in the maintenance shop (#551). Such shavings and turnings must be collected due to the potential to leach lead if disposed at the landfill. A contain-er for the disposal of brass items is located in building 801. Brass will be collected at the LGDRM until such a time as there is enough material to ship a container for recycling.
4.4 Filters
Air filters: Filters from all ventilation systems are disposed of at the sanitary landfill. The filter from the paint booth in Vehicle Maintenance, Bldg. #580, contains elevated levels of toxic metal and is treated as a hazardous waste stream.
Fuel and oil filters
4.5 Liquid Wastes
: Fuel and oil filters are drained and crushed in a designated crusher and then collected in lined drums and turned in through LGDRM. The drained fuel and oil is burned at K-plant for energy recovery.
Glycol waste: Glycol waste is recycled at the generator. When glycol waste is too old to be re-used, the waste is disposed of via the LGDRM as non-HW.
Antifreeze: Antifreeze waste is accumulated and disposed of via the LGDRM as non-HW.
Paint: The majority of the paint at Thule AB is water based paint or latex paint. Excess paint is accumulated and disposed of via the LGDRM as non-HW.
POL:
4.6 Paint Cans
Used oil and other petroleum, oil and lubricating (POL) products may be used for energy recovery if it fulfils the requirements of the HWMP, CDRL CEV-15B. Otherwise the waste must be disposed of as hazardous waste. At Thule AB, used oil is burned at the K-plant.
Empty paint cans (aerosols) must be punctured and dried before they are disposed at the sanitary landfill.
4.7 Rags
Rags and other types of material used for cleaning, e.g., parts containing non-hazardous materials, can be disposed of at the sanitary landfill. Rags and other types of cleaning material containing hazardous materials must be disposed of according to the HWMP, CEV-15B.
4.8 Sweeping Compound (Absorbant)
Sweeping compound can be disposed of at the sanitary landfill except if it was used with a hazardous material (HM). In this case, it must be disposed of as HW.
4.9 Building Debris
Building debris from construction and demolition projects at Thule AB can be disposed of at the sanitary landfill, if hazardous material/waste and other regulated waste according to this plan and other Thule AB plans and programs have been removed. However, bulk metal from demoli-tion projects can be collected at a designated location at the LGDRM yard, provided it is pre-
Thule Air Base, Greenland 11/26 pared for recycling. Additional information concerning scrap metal recycling is included in Ap-pendix 8.
It is the responsibility of the operational personnel that HW material is not discharged into the landfill such as construction lead and asbestos.
4.10 LED Light bulbs
Any waste containing LED light bulbs will be allowed at the landfill for disposal, unless the waste meets any of the criteria for being hazardous waste. In that case it will be treated as such.
4.11 Special generated waste
4.11.1 UXO areas
In 2003 The United States Air Force (USAF) contracted with a private contractor to perform a preliminary unexploded ordinance (UXO) site investigation at Thule AB. The contract included visual sweeps of off-base areas where UXO had previously been found, delineation of other UXO source areas, and mapping of located UXO items.
The area below the sanitary landfill in the direction of Fox Canyon is a known UXO area. Signs are posted to warn landfill workers.
4.11.2 Arctic Foxes
Arctic foxes at the Thule Defense Area have the potential to carry rabies. The Danish Police Inspector (DPI) will shoot any fox found to be exhibiting abnormal behavior, a symptom of rabies. The dead fox shall be enclosed in bio hazardous waste bags provided at the Base Hospital and accumulated in a drum provided by GC/EE, before the drum is buried at the sanitary landfill by GC/OMPG.
4.11.3 Medical Waste
The medical waste is managed by sterilization prior to disposal. Medical waste, including sharps, is stored in bags with the biohazard symbol, and then placed in a refrigeration unit in a locked room. When an adequate volume has accumulated, it is sterilized in a steam sterilization unit.
Sterilized medical waste is transported to the landfill for disposal. Unsterilized medical waste is not accepted at the landfill. Personnel at the base clinic will immediately dispose of sterilized waste in a special container at the base clinic. This avoids accidentialy having non-sterilized waste disposed at the landfill.
Empty epinephrine vials are considered sharp objects and must be treated as medical waste IAW the Base Clinic procedures.
Thule Air Base, Greenland 12/26
5 UNACCEPTABLE WASTE
Unacceptable waste, such as hazardous waste (regulated and non-regulated), infectious medical waste, polychlorinated biphenyl (PCB) waste, asbestos waste, radioactive materials and waste determined unsuitable for the landfill (e.g., wastes incorporated as serviceable materials, rolling stocks scrap) must not be disposed of at the landfill.
Landfill operational staff receives appropriate training to identify and dispose of unacceptable waste. GC/EE will be contacted for instructions if suspected or confirmed unacceptable wastes are identified at the landfill.
It is mandatory for all personnel and guests to TAB to avoid unacceptable waste to be disposed in the regular trash dumpsters. GC/EE is responsible for conducting awareness campaigns (using signs, TV channels, pamphlets etc.) to ensure the base population is aware of unacceptable wastes. Further, GC and USAF newcomers attend a briefing that states what should be done with the various types of waste.
5.1 Hazardous Waste
All hazardous waste must be disposed of according to the Hazardous Waste Management Plan, CDRL CEV-15B. The hazardous waste is shipped off base for proper disposal.
The Waste identification process is shown in the flowchart below – Solid Waste versus Hazardous Waste:
Solid waste
Is the waste listed in HWMP?
Does the waste exhibit any of the 4 characteristics specified in HWMP (ignitable, corrosive, reactive, toxic)?
No
The waste is hazardous waste
See HWMP
The waste is solid waste
Yes
No
Yes
Figur 1: Flowchart of HW identification guidelines
Thule Air Base, Greenland 13/26
5.2 Infectious Medical Waste
The Final Governing Standard (FGS), Chapter 8, requires that infectious medical waste is incinerated, but Thule AB does not have an incinerator. Stored blood and pathological waste is therefore shipped to the U.S. for incineration at the Andrews AFB Clinic.
5.3 Polychlorinated Biphenyl (PCB)
Any PCB containing items must be correctly marked in both English and Danish.
• Ballasts are removed from service during maintenance. Ballasts containing or suspected to contain PCB are collected and accumulated in Hazardous Waste Accumulation Points (HWAPs), and turned in as hazardous waste through the LGDRM according to the HWMP, CDRL CEV-15B.
• There is no longer any known PCB containing transformers in service at Thule AB. If unmarked transformers are located it will be determined if they will be treated IAW the PCB Replacement Plan, CDRL CEV-12.
5.4 Asbestos Waste
Asbestos Containing Material (ACM) is disposed of at the asbestos landfill located behind South Mountain. The Asbestos Management Plan, CDRL CEV-15A provides instructions for proper disposal.
5.5 Waste Unsuitable for the Sanitary Landfill
Waste unsuitable for the sanitary landfill includes hazardous, asbestos and PCB waste as mentioned above. Furthermore regulated waste (non-hazardous POL products unsuited for incineration, glycol, water-based paint etc), serviceable materials (e.g. functional TV sets), radioactive materials, rolling stocks scrap and electronic parts are disposed of via the LGDRM.
Items such as refrigerators will be drained for refrigerant by GC/CEOM prior to disposal.
Facilities will be surveyed for all these materials prior to demolition.
5.5 Solids from Sewage
It is prohibited to dispose sewage (including screened solids from sewage) at the sanitary landfill.
Thule Air Base, Greenland 14/26
6 RECYCLING AND REUSE
6.1 Recycling
The recycling program ceased in October 2006 according to DCR 06-086 Recycling Program Descope (Appendix 3). AFI 32-7042 requires each installation to have a Qualified Recycling Program. Appendix 8 contains the Qualified Recycling Program Business Plan for Thule AB.
This plan discusses the management of recyclable materials generated on Thule AB.
The waste that was previously recycled, e.g. aluminum cans, scrap metal, glass, cardboard, paper etc., is now disposed of at the landfill unless it is included in hazardous waste stream (HWMP, CEV-15B app. 2) in which case it is disposed of as non-regulated hazardous waste.
The July 2007 report Final Qualified Recycling Program Initial Assessment Report for Thule Air Base, Greenland supported the financial considerations that led to the descoping.
In the 2011 QRP plan at page 26, there are referred to an account number. The number in the report is 573875.890083A1503000, Doc ID RRRP-Peterson, DSR097038, PSR970080.
This should be 57F3875.890083A1503000, DocID RRRP-Peterson, DSR097038 PSR970080, MAFR T Post Code EX.
Currently, recycling at Thule is limited to high value copper cable scrap and acid-lead batteries.
Both of these are sent out annually on the Pacer Goose. Car tires are collected and shipped to Denmark (GC initiative). Furthermore, waste oil is reused for energy recovery at the K-plant.
6.2 Solid waste reduction strategy
Thule’s long term strategy for reduction of solid waste and reuse through energy recovery has been identified as a requirement for a waste incineration facility. Such a facility is awaiting com-pletion of MILCON project WWCX 06-3001 Solid Waste Disposal Facility, scheduled for FY16.
A waste to energy study was conducted by TetraTech during the summer of 2010 to determine if there are any new technologies that can be used and determine if there is a high return of in-vestment (ROI) for converting waste to energy. If there is a good ROI, then this new system could possibly be funded under Energy Conservation Investment Program (ECIP), hopefully in-creasing the chance of funding. The Tetra Tech waste energy study is expected to covers solid waste streams (incineration of hazardous waste is not permitted in the FGS).
A waste to energy study was conducted by TetraTech during the summer of 2010 to determine if there are any new technologies that can be used and determine if there is a high return of in-vestment (ROI) for converting waste to energy. The waste to energy feasibility evaluation identi-fied a suitable technology for use at Thule AB and the ROI indicated that a waste to energy could be economically beneficial at Thule AB. Implementation of a waste to energy system is currently being evaluated by Air Force Space Command personnel.
Thule Air Base, Greenland 15/26
7 LANDFILL OPERATIONS
7.1 Requirements
Thule AB has one sanitary landfill, which is an open landfill located on South Mountain east of DET-1. An open landfill is defined as a landfill where the disposal is exposed to the elements, vectors and scavengers. The landfill receives solid waste from households, maintenance activities, construction and demolition, as well as waste from ships and aircraft.
Waste will be pressed to a density of 1000-1200 lbs/CY by a 40 ton compactor vehicle. Load checks are conducted to ensure unacceptable wastes are not being disposed of within the landfill. Signs are posted and visible to all load transporters stating that unacceptable wastes are prohibited from entering the landfill. Any inappropriate items (chapter 5) are taken to the local LGDRM for determination of proper disposal.
The MOU between the USAF and the Greenland Home Rule states that material capable of being burned should be burned rather than being buried at the landfill. However, Thule AB does not have an incinerator and all solid waste is therefore disposed of at the landfill.
7.2 Site security
The entrance to the landfill is enclosed by a chain-link fence. A sign is posted at the entrance to the landfill “People without any official business at the dump, have no permission to enter”.
It is the P&G supervisor to ensure that the main gate to the sanitary landfill is locked outside normal work hours.
Normally, only the landfill operators enter the landfill, but during the summer other individuals/contractors might enter the landfill with building debris, etc. The P&G Supervisor can approve individuals for unsupervised access to the landfill.
7.3 Sections
The solid waste is disposed in designated areas at the landfill in order to fill it up in a planned manner. However, construction and demolition debris and household wastes do not designated sections.
The P&G supervisor will designate a location for seasonal contractors to unload and ensure that the waste is included in the disposal records (section 7.5). If the P&G supervisor or appointed POC is not available, GC/EE can be consulted for instructions.
7.4 Cover
Cover material is used to prevent garbage from blowing, decrease the chance of fire, and provide protection from disease vectors. The cover material must be excavated during the summer months when the surface is thawed. The cover material is stockpiled close to the active part of the landfill.
When household waste arrives at the landfill they are disposed of in the designated section where they will be compacted. The household waste is covered daily at the end of each day, and other waste as required to prevent the garbage from blowing. During winter operations, severe weather conditions may limit the ability to cover the waste, as the cover soil is frozen; however, the severe weather would also limit any potential vector problem.
Thule Air Base, Greenland 16/26
7.5 Disposal records
Records are maintained for waste disposed at the landfill. The landfill operator records the daily volume of household waste. Construction and building debris are recorded, in a log located in the facility, by the person who delivers the waste at the landfill. Copper cable scrap is recorded by LGDRM.
It is the responsibility of the P&G Supervisor that all waste disposal is recorded, including waste disposed by seasonal contractors. The requirement will be communicated to seasonal contractors when the supervisor approves the use of the landfill.
Thule AB does not have a scale and the quantity of waste is reported in volume and converted to weight by the use of standard conversion factors as most reporting is required in weight and not volume.
7.6 Inspections
In order to insure compliance with FGS 7.3.12 Operation of MSWLF´s, GC/EE will perform inspection at the landfill at least once a month and documentation will be kept at the EE office.
The inspection will include but is not limited to the following:
• Daily cover
• Security
• Solid waste in stream
• Hazardous Waste at Landfill
• The overall aesthetically acceptability
The checklist included in Appendix 4 is used for GC/EE inspections.
7.7 Vector Control
Due to the harsh climate at Thule AB, vector problems are not a concern. The only animals feeding from the landfill are arctic foxes, sea gulls and ravens. The Danish Police Inspector (DPI), who will also ensure that rabies tests are performed in coordination with the Base Hospital, controls the fox population annually.
7.8 Methane Monitoring
The methane gas generated at the landfill is limited and there is no risk for concentrations to approach the 25% of lower explosive limit requirement stated in the FGS. The facilities located at the landfill are raised above ground and possible generated methane gas will not enter the facilities.
7.9 Biodegradation
Thule AB is located in a harsh environment and the temperature fluctuates between -40°F in the winter, when the soil is frozen, to a high of 60°F for a short period during the summer. Even during the summer period, the air temperature occasionally drops below freezing.
Some permafrost microflora are metabolically active at temperatures below 32°F, but temperatures below 20°F appears to be suboptimal for biodegradation in Arctic soils. Therefore, some biodegradation is assumed to occur, but the rate is very slow compared to landfill biodegradation in a temperate climate.
Thule Air Base, Greenland 17/26
7.10 Personnel training
All operators hauling and transporting solid waste to the landfill attend the hazardous waste handler training course in order to be able to identify and prevent disposal of hazardous waste to the sanitary landfill. The hazardous waste handler course is held twice a year. Operators are re-sponsible for recovering hazardous waste and other unwanted wastes, if any is seen at the land-fill.
Seasonal contractors that need to use the landfill are briefed about regulations at pre-construction meetings or environmental briefings.
Thule Air Base, Greenland 18/26
APPENDIX 1: DEFINITIONS
Bulk Waste – Items of solid waste such as household appliance, furniture, large auto parts, and other oversized waste, which, because of the size, preclude or complicate the handling, collection, processing, or disposal of the solid waste
Construction and Demolition Waste - Building materials, packaging, and rubbles resulting from construction, remodeling, repair, and demolition operations on pavements, houses, commercial buildings, and other structures.
Dispose and disposal – To throw away or discard intentionally or accidentally. Disposal includes spills, leaks, and other uncontrolled discharges.
LGDRM – DoD organization, which arranges recycling, sale, or disposal of wastes and surplus material.
Dumpster - See Solid Waste Storage Container.
Environmental Protection Committee (EPC) – Environmental organization, chaired by the instal-lation commander at major Air Force installations, whose main purpose is to ensure environmental concern in every phase of Air Force activities.
Final Cover - Cover material, which serves the same function as daily cover but, in addition, may be permanently exposed on the surface.
Final Governing Standard – Country specific substantive provisions, typically technical limitations on effluents, discharges, etc., or a specific management practice, with which DoD components must comply.
Fiscal Year – Period from 1 October to 30 September of the designated year (FY07: 1 October 2006 – 30 September 2007).
Food Waste - The organic residues generated by the handling, storage, sale, preparation, cooking and serving of foods, commonly called garbage.
Host Nation – A nation, which receives the forces or supplies of allied nations or NATO organiza-tions to be located on, to operate in, or to transit through its territory.
Infectious Medical Waste - Solid waste produced by medical and dental treatment facilities, which is specially managed because it might cause diseases and may pose a risk to both individuals and community health, if not managed properly. The term includes microbiology waste, pathology waste, human blood and blood products, potentially infectious materials, sharps, and infectious wastes (including only those items that are contaminated, or are likely to be contaminated, with infectious agents or pathogens, and excretion exudates and discarded material contaminated with blood).
Installation – A grouping of facilities, located in the same vicinity, which support particular functions.
Land Disposal - Placement in or on land, including, but not limited to, land treatment, facilities, sur-face impounds, underground injection wells, salt dome formations, salt bed formations, under-ground mining, or caves.
Thule Air Base, Greenland 19/26
Municipal Solid Waste - Normally residential and commercial solid waste generated within a community, not including yard waste.
Non-PCB Item - All equipment containing less than 50 ppm (parts per million) PCB.
Open landfill – A land disposal site at which solid wastes are disposed of in a manner that does not protect the environment, is susceptible to open burning, and is exposed to the elements, vectors, and scavengers.
Recyclable Waste – Any waste material with the potential for added value through reworking to a similar or different usable product.
Recycling – Offering a product, otherwise designated to be discarded, for reworking to a similar or different usable product.
Recycling Collection – The process of collecting recyclable material at the point of generation as well as at recycling collection points.
Recycling Disposal – Removal of recyclable material from an installation to a facility where it is incorporated in a new useable product.
Sanitary Landfill - A land disposal site employing an engineered method of disposal of solid waste on land in a manner that minimizes environmental hazards by spreading the solid waste in thin lay-ers, and applying and compacting cover material at the end of each operating day.
Solid Waste - Garbage, refuse, sludge, and other discarded materials, including solid, semisolid, liquid, and gaseous containing materials, resulting from industrial and commercial operations and from community activities. It does not include solids or dissolved material in domestic sewage or other significant pollutants in water resources, such as silt, dissolved, or suspended solids in indus-trial wastewater effluent, dissolved materials in irrigation return flows or other common water pollu-tants.
Solid Waste Storage Container - A receptacle used for the temporary storage of solid waste while awaiting collection.
Thule AB - Thule Air Base
Vector - A carrier which is capable of transmitting a pathogen from one organism to another.
Thule Air Base, Greenland 20/26
APPENDIX 2: ABBREVIATIONS AND ACRONYMS USED
AB Air Base ACM Asbestos Containing Material AFI Air Force Instruction APO American Post Office Bldg. Building BMEWS Ballistic Missile Early Warning System CC Commander CDRL Contract Data Requirements List CE Civil Engineering CES Civil Engineering Squadron (of 21st Space Wing) CEAN Environmental Management (of 21st Space Wing Civil Engineering Squadron) CFY Current Fiscal Year DET Detachment (Detachment 3 of 22nd Space Operations Squadron) DLO Danish Liaison Officer DoD Department of Defense DPI Danish Police Inspector LGDRM Defense Reutilization and Marketing Office DSN Defense Switched Network EE Environmental Engineering EPC Environmental Protection Committee Ext Extension FGS Final Governing Standards FY Fiscal Year GC Greenland Contractors GE-A General Electric – Americom GHR Greenland Home Rule HM Hazardous Material HW Hazardous Waste HWMP Hazardous Waste Management Plan LGS Base Supply MAS Maintenance Action Sheet MOU Memorandum of Understanding POL Petroleum, Oil and Lubricants SF Security Forces SWMP Solid Waste Management Plan SWS Space Warning Squadron TABI Thule Air Base Instruction USAF United States Air Force
Thule Air Base, Greenland 21/26
APPENDIX 3: RECYCLING PROGRAM DESCOPE DCR DOCUMENTA-
TION
Thule Air Base, Greenland 22/26
APPENDIX 4: INSPECTION CHECK LIST FOR SANITARY LANDFILL
GC/EE MONTHLY INSPECTION CHECK LIST FOR SANITARY LANDFILL
Inspector: _______________
Date: _______________
Present: _______________
N/A YES NO INSPECTION (SANITARY LANDFILL)
Is the landfill operated in an aesthetically acceptable manner?
Is the waste covered daily?
If this inspection is performed outside normal operation hours – is the gate then locked?
Are the entrance fence, gate lock and warning signs at the landfill in an acceptable condition?
Is the logbook over solid waste volumes transferred to the sanitary landfill updated?
Are the condition of the fueling station and fuel tanks placed at the entrance to the landfill area in an acceptable condition?
Are all personnel who are or could be exposed to hazardous waste current on their training?
Is there any electronic waste to be observed at Landfill?
Is there any hazardous waste to be observed at Landfill?
Is there any liquid wastes (non-containerized or bulk) observed?
Is there any solid waste to be observed in stream running along the landfill?
Is the number of arctic foxes present at the landfill a problem for operation?
Comments:
Next Inspection: _______________________
Inspector signature: _______________________
Thule Air Base, Greenland 23/26
APPENDIX 5: REFERENCES
Reference 1: AFI 32-7006: Environmental Program for Foreign Countries
Reference 2: AFI 32-7042, Solid and Hazardous Waste Compliance (guidance)
Reference 3: AFI 32-7042, Waste Management, 21 April 2009, Chapter 3, para 3.6.3
Reference 4: DoD 4160.21-M, Defense Material Disposition Manual, Chapter 7, section N
Reference 5: Final Governing Standard (FGS), Chapter 7
Reference 6: Final Governing Standard (FGS), Chapter 8
Reference 7: QI 09.39.00.010, Refuse Collection
Reference 8: TABI 32-101, Management of Electrical Equipment Containing Polychlorinated Biphenyls (PCB)
Reference 9: Thule AB Hazardous Waste Management Plan, CDRL CEV-15B
Reference 10: Thule AB Asbestos Management Plan, CDRL CEV-15A
Reference 11: Report: Final Landfill assessment and operations Management Plan, Dec 2005
Thule Air Base, Greenland 24/26
APPENDIX 6: DISTRIBUTION LIST
The PDF document is distributed via email IAW CDRL Summary list.
Distributed in PDF format
21st Space Wing
21 CES/CEAN
William.ritchie@peterson.af.mil Todd.degarmo@peterson.af.mil
21 SW/PMO 21sw.pmd.thule@peterson.af.mil
821st Air Base Group Commander
821SPTS.PM@thule.af.mil
821st Support Squadron Civil Engineer Flight Commander
821SPTS.CE@thule.af.mil
Greenland Contractors, Thule Air Base All GC organizations on GC LAN (Intranet) mailto:William.ritchie@peterson.af.mil� mailto:Todd.degarmo@peterson.af.mil� mailto:21sw.pmd.thule@peterson.af.mil� mailto:821SPTS.PM@thule.af.mil� mailto:821SPTS.CE@thule.af.mil�
Thule Air Base, Greenland 25/26
APPENDIX 7: REVIEW COMMENTS
Item
Office Symbol
Org Page# Para# Critical, Substantive or Administrative
Comment Rationale Accept Modify Reject
Rationale
NOTE: Comments 1-2 are recommendations.
1 CEANN 21
CES
26 Appendix 8, line 5
Critical PAFB account number should read:
57F3875.890083A1503000, DocID RRRP-Peterson, DSR097038 PSR970080, MAFR T Post Code EX
Account number is required to re-ceive reimburse-ment from DLA Disposition Ser-vices
R Appendix 8 is a third party report prepared in 2011 by TetraTech. It has been added to the plan in order to docu-ment the results of the market analysis per-formed at that time. GC cannot change individual sentences or facts and still preserve the intention of add-ing the appendix.
The suggested change has been added to the main part of the plan
2 CEANN 21
CES
Add an appendix with 21 CES/CEAN comments.
To see if com-ments were added or rejected.
A
Thule Air Base, Greenland 26/26
APPENDIX 8: QUALIFIED RECYCLING PROGRAM BUSINESS PLAN
| CDRL CEV-15E |
| SOLID WASTE MANAGEMENT PLAN |
| Thule Air Base, Greenland |
| Final FY-12 |
| OPR: GREENLAND CONTRACTORS |
| Chief of Environmental Engineering |
| 1 LETTER OF INSTRUCTION |
| 1.1 Security and administrative instructions |
| 2 GENERAL |
| 2.1 Purpose |
| 2.2 Scope |
| 2.3 Regulatory Overview |
| US State Laws: Not applicable |
| 3 ORGANIZATIONAL ROLES AND RESPONSIBILITIES |
| 3.1 Commander, 821 ABG/CC |
| 3.2 Danish Liaison Officer, DLO |
| 3.3 Environmental Engineering, GC/EE |
| 3.4 CE Operations & Maintenance, GC/CEOM |
| 3.5 GC/LGDRM |
| 3.6 CE O & M/Utilities & Facilities Maintenance, GC/OMUFM |
| 3.7 General Personnel |
| 4 SOLID WASTE streams |
| 4.1 Batteries |
| 4.2 Toner Cartridges, Toner and Developer |
| 4.3 Scrap Metal |
| 4.4 Filters |
| 4.5 Liquid Wastes |
| 4.6 Paint Cans |
| 4.7 Rags |
| 4.8 Sweeping Compound (Absorbant) |
| 4.9 Building Debris |
| 4.10 LED Light bulbs |
| 4.11 Special generated waste |
| 4.11.1 UXO areas |
| 4.11.2 Arctic Foxes |
| 4.11.3 Medical Waste |
| 5 Unacceptable Waste |
| 5.1 Hazardous Waste |
| 5.2 Infectious Medical Waste |
| 5.3 Polychlorinated Biphenyl (PCB) |
| 5.4 Asbestos Waste |
| 5.5 Waste Unsuitable for the Sanitary Landfill |
| 5.5 Solids from Sewage |
| 6 Recycling and reuse |
| 6.1 Recycling |
| 6.2 Solid waste reduction strategy |
| 7 Landfill OPERATIONS |
| 7.1 Requirements |
| 7.2 Site security |
| 7.3 Sections |
| 7.4 Cover |
| 7.5 Disposal records |
| 7.6 Inspections |
| 7.7 Vector Control |
| 7.8 Methane Monitoring |
| 7.9 Biodegradation |
| 7.10 Personnel training |
| APPENDIX 1: Definitions |
| Dumpster - See Solid Waste Storage Container. |
| Non-PCB Item - All equipment containing less than 50 ppm (parts per million) PCB. |
| Open landfill – A land disposal site at which solid wastes are disposed of in a manner that does not protect the environment, is susceptible to open burning, and is exposed to the elements, vectors, and scavengers. |
| Thule AB - Thule Air Base |
| APPENDIX 2: Abbreviations and Acronyms Used |
| APPENDIX 3: Recycling Program Descope DCR Documentation |
| APPENDIX 4: INSPECTION CHECK LIST FOR SANITARY LANDFILL |
| APPENDIX 6: Distribution List |
| APPENDIX 7: REVIEW COMMENTS |
| APPENDIX 8: Qualified recycling program business plan |
File details come from the government source that posted it. Updated .