UP

UP

UP

60' - 1"

0' - 6" 2' - 6"

10' - 2" 4' - 6" 3' - 4"

1' - 9" 13' - 9" 10' - 8" 9' - 9" 2' - 8" 0' - 6"

0' - 6" 17' - 0" 5' - 2" 1' - 10"

12' - 0" 2' - 10" 3' - 4" 16' - 11" 0' - 6"

60' - 1"

0'

6"

3'

4"

3'

4"

0"

0" 0'

6"

0'

6" 2'

6"

5'

0"

5'

0"

7'

8" 9'

0"

7'

8" 9'

0"

7'

8" 8'

0"

5'

2" 2'

4"

0'

6"

0'

8"

0'

8"

20' - 0"

15' - 4"

SIGN

SHOP

CARPENTRY

SHOP

STAIR 2

A-111

A-111

RESTROOM

WAREHOUSE

161818

17 TYP, ALL COLUMNS

STAIR 1

A

19B

C

15' - 4"

RESTROOM

STAIR 2

WAREHOUSE

2'

4" 5'

2"

1'

6"

13' - 4"

9'

0"

2'

2" 3'

4"

0'

2'

9"

BOTH SIDES,

UNDER STAIR

ABOVE

STAIR

7 BOTH SIDES

19D

19E

2'

5'

8"

SIGN

SHOP

CARPENTRY

SHOP

19' - 7"

3'

4"

2'

2'

6"

7' - 2" 9' - 9" 2' - 8"

STAIR 1

BOTH SIDES

19H

19F

19J

G

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-111

BL

D

G

FL

O O

R P

LA

N

M

IS

SO

U

R I R

IV

ER

P R

O

JE

C T

O

FF

IC

E, N

EB

R

AS

KA

O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

EN

U

E O

M

AH

A, N

E

R . A

H

LE

R S

R . A

H

LE

R S

B.

G

O R

U P

B.

G

O R

U P

/1

8/

W

F-

-Q

-0

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

M R

PO

P

O

ST

F

LO

O D

R

EH

AB

IL

IT

AT

IO

N

(F Y1

9)

O D

_M

R

PO

.R

VT

3/32" = 1'-0"1 BLDG 19 FLOOR PLAN

1/4" = 1'-0"3 ENLARGED RESTROOM

1/4" = 1'-0"2 ENLARGED SHOPS

KEYNOTE LEGEND

1 REMOVE ALL FINISHES AND GYP BD, WASH, SANITIZE AND DRY

INSULATED CONCRETE FORMWORK TO 3’-0” AFF. PROVIDE AND

INSTALL NEW LINER PANEL (LP-1) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 1/A-501. MODERATE WATER PRESSURE DURING WASH TO

PRESERVE THE INTEGRITY OF EXPANDED POLYSTYRENE (EPS)

MATERIAL.

2 REMOVE ALL LINER PANEL FOR FULL HEIGHT OF WALL. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW LINER PANEL (LP-1) FOR FULL

WALL HEIGHT OF WALL WITH METAL WAINSCOT TRIM AT 3’-0” AFF.

SEE DETAIL 2/A-501. MODERATE WATER PRESSURE DURING WASH

TO PRESERVE THE INTEGRITY OF EXPANDED POLYSTYRENE (EPS)

MATERIAL.

3 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND TILE

(CT-1) TO 6’-0” AFF. NEW TILE AND GROUT TO MATCH EXISTING TILE

AND GROUT IN COLOR, TEXTURE, AND PATTERN. PROVIDE AND

INSTALL NEW GLASS MAT GYP BD AND FRP WALL BOARD ABOVE

6’-0” AFF TO MATCH EXISTING. SEE DETAIL 3/A-501.

4 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND FRP

WALL BOARD TO MATCH EXISTING. PROVIDE NEW TILE BASE TRIM

(CT-2) to 0’-4” AFF. SEE DETAIL 4/A-501. MODERATE WATER

PRESSURE DURING WASH TO PRESERVE THE INTEGRITY OF

EXPANDED POLYSTYRENE (EPS) MATERIAL.

5 REMOVE ALL FINSHES, GYP BD, AND INSULATION, POWER WASH,

SANITIZE AND DRY CMU WALL AND WOOD FRAMING TO 3’-0” AFF.

PAINT CMU WALL AND WOOD FRAMING MEMBERS WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

2” MINIMUM CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE

AND INSTALL NEW LINER PANEL (LP-2) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 5/A-501.

6 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING AND CMU WALL TO 4’-3 1/2” AFF (HEIGHT OF

FURRED PLUMBING WALL, FIELD VERIFY). PROTECT EXISTING

PLUMBING ROUGH-INS AND FIXTURES FROM DAMAGE. PAINT

WOOD FRAMING AND CMU WALL WITH A WATER-REPELLENT,

VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM

CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE AND INSTALL

NEW GLASS MAT GYP BD AND TILE (CT-2) TO 4’-3 ½” AFF (FV) AND

AT HORIZONTAL LEDGE ABOVE FURRED PLUMBING WALL. NEW

TILE AND GROUT TO MATCH EXISTING TILE AND GROUT IN COLOR,

TEXTURE, AND PATTERN. SEE DETAIL 6/A-501.

7 REMOVE PANEL WAINSCOT, AND INSULATION. METAL WAINSCOT

TRIM TO REMAIN. POWER WASH, SANITIZE AND DRY FRAMING

MEMBERS TO APPROXIMATELY 3’-0” AFF (HEIGHT OF EXISTING

WAINSCOT, FIELD VERIFY). PROVIDE 2” MINIMUM CLOSED-CELL

SPRAY FOAM INSULATION. PROVIDE AND INSTALL NEW LINER

PANEL (LP-2) WAINSCOT TO 3’-0” AFF. SEE DETAIL 7/A-501.

8 REMOVE EXTERIOR METAL PANEL WHERE INDICATED, WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO

APPROXIMATELY 3’-2” AFF (HEIGHT OF EXISTING PAINT FINISH

TRANSITION, FIELD VERIFY). PROVIDE AND INSTALL NEW

EXTERIOR METAL PANEL (MP-1). PROVIDE FLASHING AT NEW

EXTERIOR METAL PANEL. FINISH TO MATCH EXISTING METAL

PANEL AT BUILDING WAINSCOT. SEE DETAIL 8/A-501. MODERATE

WATER PRESSURE DURING WASH TO PRESERVE THE INTEGRITY

OF EXPANDED POLYSTYRENE (EPS) MATERIAL.

9 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING TO 3’-0” AFF. PAINT WOOD FRAMING WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

AND INSTALL NEW LINER PANEL (LP-1) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 9/A-502.

10 REMOVE ALL FINSHES, GYP BD, AND INSULATION, POWER WASH,

SANITIZE AND DRY WOOD FRAMING AND LATH BEYOND (WHERE

OCCURS) TO 3’-0” AFF. PAINT WOOD FRAMING AND LATH BEYOND

(WHERE OCCURS) WITH A WATER-REPELLENT, VAPOR-OPEN

ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM CLOSED-CELL SPRAY

FOAM INSULATION. PROVIDE AND INSTALL NEW LINER PANEL

WAINSCOT TO 3’-0” AFF. SEE DETAIL 10/A-502.

11 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. POWER

WASH, SANITIZE AND DRY FRAMING MEMBER TO 3’-0” AFF.

PROTECT EXISTING PLUMBING ROUGH-INS AND FIXTURES FROM

DAMAGE. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND

TILE (CT-1) TO 6’-0” AFF. NEW TILE AND GROUT TO MATCH EXISTING

TILE AND GROUT IN COLOR, TEXTURE, AND PATTERN. PROVIDE

AND INSTALL NEW GLASS MAT GYP BD AND FRP WALL BOARD

ABOVE 6’-0” AFF TO MATCH EXISTING. SEE DETAIL 11/A-502.

12 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING AND CMU WALL TO 4’-3 1/2” AFF (MATCH

HEIGHT OF FURRED PLUMBING WALL, FIELD VERIFY). PAINT WOOD

FRAMING AND CMU WALL WITH A WATER-REPELLENT,

VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM

CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE AND INSTALL

NEW GLASS MAT GYP BD AND TILE (CT-2) TO 4’-3 ½” (FV). NEW TILE

AND GROUT TO MATCH EXISTING TILE AND GROUT IN COLOR,

TEXTURE, AND PATTERN. SEE DETAIL 12/A-501.

13 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. POWER

WASH, SANITIZE AND DRY FRAMING MEMBER TO 3’-0” AFF.

PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND FRP WALL

BOARD TO MATCH EXISTING. PROVIDE NEW TILE BASE TRIM (CT-2)

to 0’-4” AFF. SEE DETAIL 13/A-502.

14 REMOVE LINER PANEL WAINSCOT. POWER WASH, SANITIZE AND

DRY CONCRETE CURB, FRAMING MEMBERS AND WOOD LATH TO

3’-0” AFF. PAINT WOOD FRAMING AND LATH WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

AND INSTALL NEW LINER PANEL (LP-2) WAINSCOT. SEE DETAIL

14/A-502.

15 REMOVE HARDWARE AND RETAIN FOR RE-INSTALLATION. REMOVE

AND REPLACE DOOR AND FRAME. POWER WASH, SANITIZE, AND

DRY ROUGH OPENING FRAMING MEMBERS TO 3’-0”. PAINT DOOR

AND FRAME TO MATCH EXISTING. RE-INSTALL EXISTING

HARDWARE. UNSERVICEABLE HARDWARE SHALL BE REPLACED TO

MATCH EXISTING WITH THE APPROVAL OF THE COR.

15A REMOVE HARDWARE AND RETAIN FOR RE-INSTALLATION. REMOVE

AND REPLACE DOOR PANEL ONLY. POWER WASH, SANITIZE, AND

DRY ROUGH OPENING FRAMING MEMBERS TO 3’-0”. PAINT DOOR

AND FRAME TO MATCH EXISTING. RE-INSTALL EXISTING

HARDWARE. UNSERVICEABLE HARDWARE SHALL BE REPLACED TO

MATCH EXISTING WITH THE APPROVAL OF THE COR.

16 REMOVE AND REPLACE BOTTOM OVERHEAD DOOR PANEL. POWER

WASH, SANITZE AND DRY ENTIRE REMAINING DOOR PANELS AND

TRACK TO REMOVE REMAINING FLOOD DEBRIS AND WATER

MARKS.

17 POWER WASH, SANITIZE AND DRY ELEMENT TO 3’-6” AFF. PREP

AND PAINT ELEMENT TO 3’-6” WITH FINISH EQUIVELANT TO THE

EXISTING.

18 POWER WASH, SANITIZE AND DRY CMU WALL TO 3’-6” AFF. PREP

AND PAINT WALL TO 3’-6” WITH FINISH EQUIVELANT TO THE

EXISTING.

19 REMOVE EXITING TILE BASE TRIM. POWER WASH, SANITIZE AND

DRY ALL EXISTING FLOOR TILE.

G

EN

ER

AL

R

EV

IS

IO

N

S 3/

/2

1 IF STRUCTURAL DAMAGE IS DISCOVERED

DURING REMEDIATION EFFORTS, STOP WORK

AND NOTIFY COR IMMEDIATELY.

2 ALL SANITIZING SHALL CONSIST OF MILD

DETERGENT WASH TO REMOVE ANY LOOSE

DIRT AND DEBRIS FROM REMAINING

SUBSTRATES. ANY DISCOVERED MOLD SHALL

BE REMEDIATED.

3 ALL DRAWINGS ARE SCHEMATIC IN NATURE

AND COMMUNICATE THE INTENT OF THE

REPAIRS.

4 CONTRACTOR IS RESPONSIBLE FOR

DISPOSAL OF ALL TRASH, DEBRIS, AND

FLOOD ITEMS DETERMINED TO BE RUINED BY

FLOOD WATERS IN THIS FACILITY. THE

REMOVAL, TEMPORARY STORAGE, AND/OR

SANITATION OF ANY EQUIPMENT SHALL BE

COORDINATED WITH COR.

5 ALL MATERIALS AND FINISHES SHALL MATCH

EXISTING IN APPEARANCE AND QUALITY AND

BE INSTALLED PER THE MANUFACTURER'S

RECOMMENDATION AND INDUSTRY

STANDARDS.

6 ANY EXISTING WAINSCOT HEIGHTS THAT

DEVIATE FROM THE HEIGHTS INDICATED IN

THE DRAWINGS SHALL BE BROUGHT TO THE

COR'S ATTENTION TO DETERMINE WETHER

THE DEVIATION IS ACCEPTABLE.

GENERAL NOTES

REF.

DW

LOCKER

ROOM

BREAK

ROOM

OFFICE

RESTROOM

WAREHOUSE

2'

8"

50' - 0"

0' - 6" 15' - 2" 18' - 8" 15' - 2" 0' - 6"

50' - 0"

2'

8"

A-112

2'

8"

50' - 0"

0' - 6" 15' - 2" 18' - 8" 15' - 2" 0' - 6"

50' - 0"

2'

8"

2'

8"

50' - 0"

0' - 6" 15' - 2" 18' - 8" 15' - 2" 0' - 6"

50' - 0"

0'

6"

3'

4"

3'

4"

3'

4"

3'

4"

3'

4"

4'

2" 3'

4"

1'

5" 0'

6"

2'

8"

0' - 6" 0' - 4"

3' - 4" 11' - 6" 18' - 8" 14' - 1" 1' - 7"

0'

6"

3'

4"

0"

1'

7"

0' - 6" 15' - 2" 18' - 8" 15' - 2" 0' - 6"

50' - 0"

2'

8"

17 TYP, ALL COLUMNS

STAIR

50C

50A

B

1' - 8" 7' - 9" 1' - 8"

3'

4" 0'

9"

1'

0" 9'

3'

5"

6'

5" 1'

4"

1'

0"

2'

0" 6'

2"

9'

9" 9'

0"

3'

4" 5'

5"

6'

5" 1'

4"

1'

0"

3'

4"

LOCKER

ROOM

BREAK

ROOM

OFFICE

RESTROOM

5' - 2"

2' - 11" 2'

6"

5'

0" 3' - 0"

1' - 0"

A-401

A

C

A-401

C

A

B

15A

15A

9 BOTH SIDES

METAL PANEL REMOVAL

LIMITS OF EXTERIOR

M

ET

AL

P

AN

EL

R

EM

O

VA

L

LI

M

IT

S

O F

EX

TE

R

IO

R

13 13

111111

11111111

STAIR

50F

50E

50D

A-502

A-502

OPP

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-112

BL

D

G

FL

O O

R P

LA

N

M

IS

SO

U

R I R

IV

ER

P R

O

JE

C T

O

FF

IC

E, N

EB

R

AS

KA

O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

EN

U

E O

M

AH

A, N

E

R . A

H

LE

R S

R . A

H

LE

R S

B.

G

O R

U P

B.

G

O R

U P

/1

8/

W

F-

-Q

-0

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

M R

PO

P

O

ST

F

LO

O D

R

EH

AB

IL

IT

AT

IO

N

(F Y1

9)

O D

_M

R

PO

.R

VT

3/32" = 1'-0"1 BLDG 50 FLOOR PLAN

1/4" = 1'-0"2 ENLARGED BLDG 50 RESTROOM

G

EN

ER

AL

R

EV

IS

IO

N

S 3/

/2

KEYNOTE LEGEND

1 REMOVE ALL FINISHES AND GYP BD, WASH, SANITIZE AND DRY

INSULATED CONCRETE FORMWORK TO 3’-0” AFF. PROVIDE AND

INSTALL NEW LINER PANEL (LP-1) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 1/A-501. MODERATE WATER PRESSURE DURING WASH TO

PRESERVE THE INTEGRITY OF EXPANDED POLYSTYRENE (EPS)

MATERIAL.

2 REMOVE ALL LINER PANEL FOR FULL HEIGHT OF WALL. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW LINER PANEL (LP-1) FOR FULL

WALL HEIGHT OF WALL WITH METAL WAINSCOT TRIM AT 3’-0” AFF.

SEE DETAIL 2/A-501. MODERATE WATER PRESSURE DURING WASH

TO PRESERVE THE INTEGRITY OF EXPANDED POLYSTYRENE (EPS)

MATERIAL.

3 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND TILE

(CT-1) TO 6’-0” AFF. NEW TILE AND GROUT TO MATCH EXISTING TILE

AND GROUT IN COLOR, TEXTURE, AND PATTERN. PROVIDE AND

INSTALL NEW GLASS MAT GYP BD AND FRP WALL BOARD ABOVE

6’-0” AFF TO MATCH EXISTING. SEE DETAIL 3/A-501.

4 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO 3’-0”

AFF. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND FRP

WALL BOARD TO MATCH EXISTING. PROVIDE NEW TILE BASE TRIM

(CT-2) to 0’-4” AFF. SEE DETAIL 4/A-501. MODERATE WATER

PRESSURE DURING WASH TO PRESERVE THE INTEGRITY OF

EXPANDED POLYSTYRENE (EPS) MATERIAL.

5 REMOVE ALL FINSHES, GYP BD, AND INSULATION, POWER WASH,

SANITIZE AND DRY CMU WALL AND WOOD FRAMING TO 3’-0” AFF.

PAINT CMU WALL AND WOOD FRAMING MEMBERS WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

2” MINIMUM CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE

AND INSTALL NEW LINER PANEL (LP-2) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 5/A-501.

6 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING AND CMU WALL TO 4’-3 1/2” AFF (HEIGHT OF

FURRED PLUMBING WALL, FIELD VERIFY). PROTECT EXISTING

PLUMBING ROUGH-INS AND FIXTURES FROM DAMAGE. PAINT

WOOD FRAMING AND CMU WALL WITH A WATER-REPELLENT,

VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM

CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE AND INSTALL

NEW GLASS MAT GYP BD AND TILE (CT-2) TO 4’-3 ½” AFF (FV) AND

AT HORIZONTAL LEDGE ABOVE FURRED PLUMBING WALL. NEW

TILE AND GROUT TO MATCH EXISTING TILE AND GROUT IN COLOR,

TEXTURE, AND PATTERN. SEE DETAIL 6/A-501.

7 REMOVE PANEL WAINSCOT, AND INSULATION. METAL WAINSCOT

TRIM TO REMAIN. POWER WASH, SANITIZE AND DRY FRAMING

MEMBERS TO APPROXIMATELY 3’-0” AFF (HEIGHT OF EXISTING

WAINSCOT, FIELD VERIFY). PROVIDE 2” MINIMUM CLOSED-CELL

SPRAY FOAM INSULATION. PROVIDE AND INSTALL NEW LINER

PANEL (LP-2) WAINSCOT TO 3’-0” AFF. SEE DETAIL 7/A-501.

8 REMOVE EXTERIOR METAL PANEL WHERE INDICATED, WASH,

SANITIZE AND DRY INSULATED CONCRETE FORMWORK TO

APPROXIMATELY 3’-2” AFF (HEIGHT OF EXISTING PAINT FINISH

TRANSITION, FIELD VERIFY). PROVIDE AND INSTALL NEW

EXTERIOR METAL PANEL (MP-1). PROVIDE FLASHING AT NEW

EXTERIOR METAL PANEL. FINISH TO MATCH EXISTING METAL

PANEL AT BUILDING WAINSCOT. SEE DETAIL 8/A-501. MODERATE

WATER PRESSURE DURING WASH TO PRESERVE THE INTEGRITY

OF EXPANDED POLYSTYRENE (EPS) MATERIAL.

9 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING TO 3’-0” AFF. PAINT WOOD FRAMING WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

AND INSTALL NEW LINER PANEL (LP-1) WAINSCOT TO 3’-0” AFF. SEE

DETAIL 9/A-502.

10 REMOVE ALL FINSHES, GYP BD, AND INSULATION, POWER WASH,

SANITIZE AND DRY WOOD FRAMING AND LATH BEYOND (WHERE

OCCURS) TO 3’-0” AFF. PAINT WOOD FRAMING AND LATH BEYOND

(WHERE OCCURS) WITH A WATER-REPELLENT, VAPOR-OPEN

ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM CLOSED-CELL SPRAY

FOAM INSULATION. PROVIDE AND INSTALL NEW LINER PANEL

WAINSCOT TO 3’-0” AFF. SEE DETAIL 10/A-502.

11 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. POWER

WASH, SANITIZE AND DRY FRAMING MEMBER TO 3’-0” AFF.

PROTECT EXISTING PLUMBING ROUGH-INS AND FIXTURES FROM

DAMAGE. PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND

TILE (CT-1) TO 6’-0” AFF. NEW TILE AND GROUT TO MATCH EXISTING

TILE AND GROUT IN COLOR, TEXTURE, AND PATTERN. PROVIDE

AND INSTALL NEW GLASS MAT GYP BD AND FRP WALL BOARD

ABOVE 6’-0” AFF TO MATCH EXISTING. SEE DETAIL 11/A-502.

12 REMOVE ALL FINSHES AND GYP BD, POWER WASH, SANITIZE AND

DRY WOOD FRAMING AND CMU WALL TO 4’-3 1/2” AFF (MATCH

HEIGHT OF FURRED PLUMBING WALL, FIELD VERIFY). PAINT WOOD

FRAMING AND CMU WALL WITH A WATER-REPELLENT,

VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE 2” MINIMUM

CLOSED-CELL SPRAY FOAM INSULATION. PROVIDE AND INSTALL

NEW GLASS MAT GYP BD AND TILE (CT-2) TO 4’-3 ½” (FV). NEW TILE

AND GROUT TO MATCH EXISTING TILE AND GROUT IN COLOR,

TEXTURE, AND PATTERN. SEE DETAIL 12/A-501.

13 REMOVE ALL FINSHES AND GYP BD FLOOR TO CEILING. POWER

WASH, SANITIZE AND DRY FRAMING MEMBER TO 3’-0” AFF.

PROVIDE AND INSTALL NEW GLASS MAT GYP BD AND FRP WALL

BOARD TO MATCH EXISTING. PROVIDE NEW TILE BASE TRIM (CT-2)

to 0’-4” AFF. SEE DETAIL 13/A-502.

14 REMOVE LINER PANEL WAINSCOT. POWER WASH, SANITIZE AND

DRY CONCRETE CURB, FRAMING MEMBERS AND WOOD LATH TO

3’-0” AFF. PAINT WOOD FRAMING AND LATH WITH A

WATER-REPELLENT, VAPOR-OPEN ACRYLIC LATEX PAINT. PROVIDE

AND INSTALL NEW LINER PANEL (LP-2) WAINSCOT. SEE DETAIL

14/A-502.

15 REMOVE HARDWARE AND RETAIN FOR RE-INSTALLATION. REMOVE

AND REPLACE DOOR AND FRAME. POWER WASH, SANITIZE, AND

DRY ROUGH OPENING FRAMING MEMBERS TO 3’-0”. PAINT DOOR

AND FRAME TO MATCH EXISTING. RE-INSTALL EXISTING

HARDWARE. UNSERVICEABLE HARDWARE SHALL BE REPLACED TO

MATCH EXISTING WITH THE APPROVAL OF THE COR.

15A REMOVE HARDWARE AND RETAIN FOR RE-INSTALLATION. REMOVE

AND REPLACE DOOR PANEL ONLY. POWER WASH, SANITIZE, AND

DRY ROUGH OPENING FRAMING MEMBERS TO 3’-0”. PAINT DOOR

AND FRAME TO MATCH EXISTING. RE-INSTALL EXISTING

HARDWARE. UNSERVICEABLE HARDWARE SHALL BE REPLACED TO

MATCH EXISTING WITH THE APPROVAL OF THE COR.

16 REMOVE AND REPLACE BOTTOM OVERHEAD DOOR PANEL. POWER

WASH, SANITZE AND DRY ENTIRE REMAINING DOOR PANELS AND

TRACK TO REMOVE REMAINING FLOOD DEBRIS AND WATER

MARKS.

17 POWER WASH, SANITIZE AND DRY ELEMENT TO 3’-6” AFF. PREP

AND PAINT ELEMENT TO 3’-6” WITH FINISH EQUIVELANT TO THE

EXISTING.

18 POWER WASH, SANITIZE AND DRY CMU WALL TO 3’-6” AFF. PREP

AND PAINT WALL TO 3’-6” WITH FINISH EQUIVELANT TO THE

EXISTING.

19 REMOVE EXITING TILE BASE TRIM. POWER WASH, SANITIZE AND

DRY ALL EXISTING FLOOR TILE.

1 IF STRUCTURAL DAMAGE IS DISCOVERED

DURING REMEDIATION EFFORTS, STOP WORK

AND NOTIFY COR IMMEDIATELY.

2 ALL SANITIZING SHALL CONSIST OF MILD

DETERGENT WASH TO REMOVE ANY LOOSE

DIRT AND DEBRIS FROM REMAINING

SUBSTRATES. ANY DISCOVERED MOLD SHALL

BE REMEDIATED.

3 ALL DRAWINGS ARE SCHEMATIC IN NATURE

AND COMMUNICATE THE INTENT OF THE

REPAIRS.

4 CONTRACTOR IS RESPONSIBLE FOR

DISPOSAL OF ALL TRASH, DEBRIS, AND

FLOOD ITEMS DETERMINED TO BE RUINED BY

FLOOD WATERS IN THIS FACILITY. THE

REMOVAL, TEMPORARY STORAGE, AND/OR

SANITATION OF ANY EQUIPMENT SHALL BE

COORDINATED WITH COR.

5 ALL MATERIALS AND FINISHES SHALL MATCH

EXISTING IN APPEARANCE AND QUALITY AND

BE INSTALLED PER THE MANUFACTURER'S

RECOMMENDATION AND INDUSTRY

STANDARDS.

6 ANY EXISTING WAINSCOT HEIGHTS THAT

DEVIATE FROM THE HEIGHTS INDICATED IN

THE DRAWINGS SHALL BE BROUGHT TO THE

COR'S ATTENTION TO DETERMINE WETHER

THE DEVIATION IS ACCEPTABLE.

GENERAL NOTES

TO REMAIN

EXISTING ICF FOR KEYNOTE

SEE FLOOR PLAN

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

NEW LINER

PANEL (LP-1)

7/8" HAT CHANNEL,

SECURED TO ICF

INTERNAL WEB

EXISTING GYP

BD TO REMAIN

WASH, SANITIZE AND

DRY INSULATION

SEE KEYNOTES

ON FLOOR PLAN

FOR CONDITION

AT OPPOSITE

WALL FACE

TO REMAIN

EXISTING ICF FOR KEYNOTE

SEE FLOOR PLAN

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

NEW LINER

PANEL (LP-1)

NEW LINER

PANEL (LP-1)

7/8" HAT CHANNEL,

SECURED TO ICF

INTERNAL WEB

WASH, SANITIZE AND

DRY INSULATION

SEE KEYNOTES

ON FLOOR PLAN

FOR CONDITION

AT OPPOSITE

WALL FACE

TO REMAIN

EXISTING GIRT PLANE EXISTING EXTERIOR WALL

PANEL TO REMAIN U.O.N.

APPROX. 3'-0" AFF

EXISTING WAINSCOT HEIGHT

(VERIFY IN FIELD)

FINSH FLOOR

NEW LINER PANEL (LP-2)

WASH SANITIZE AND DRY

EXISTING FRAMING

MEMBERS

EXISTING LINER

PANEL TO REMAIN

EXISTING FRAMING,

VERIFY LOCATION

EXISTING EXTERIOR

WALL PANEL TO REMAIN,

U.O.N. SEE KEYNOTES

ON FLOOR PLAN

REMOVE EXISTING

FIBERGLASS BATT

INSULATION AND REPLACE

WITH CLOSED-CELL SPRAY

FOAM INSULATION

MIN.

0' - 2"

EXISTING BATT

INSULATION TO REMAIN

3'-2" AFF

WAINSCOT HEIGHT

FINSH FLOOR

NEW EXTERIOR

METAL PANEL (MP-1),

MATCH EXISTING IN

COLOR AND PROFILE

WASH SANITIZE AND

DRY EXISTING

FRAMING MEMBERS

EXISTING EXTERIOR

METAL WALL PANEL

TO REMAIN

WASH, SANITIZE AND

DRY INSULATION,

WHERE OCCURS AT

ICF WALL

SEE KEYNOTES

ON FLOOR PLAN

FOR CONDITION

AT OPPOSITE

WALL FACE

PLANE TO REMAIN

EXISTING GIRT

FOR KEYNOTE

SEE FLOOR PLAN

REMOVE EXISTING

FIBERGLASS BATT

INSULATION AND

REPLACE WITH

CLOSED-CELL SPRAY

FOAM INSULATION

EXISTING STUD WALL

TO REMAIN

TO REMAIN

EXIST CMU TO REMAIN

EXISTING METAL PANEL

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

NEW LINER

PANEL (LP-2)

WASH SANITIZE AND

DRY EXISTING WOOD

FRAMING, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN,

ACRYLIC LATEX PAINT

EXISTING GYP

BD TO REMAIN

MIN.

0' - 2"

NEW STEEL

STUD BLOCKING

AT WAINSCOT

WASH SANITIZE AND

DRY EXISTING CMU

WALL, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN, ACRYLIC

LATEX PAINT

REMOVE EXISTING

FIBERGLASS BATT

INSULATION AND

REPLACE WITH

CLOSED-CELL SPRAY

FOAM INSULATION

EXISTING BATT

INSULATION

TO REMAIN

4'-3 1/2" AFF

T.O. PLATE

FINSH FLOOR

EXISTING STUD WALL

TO REMAIN

TO REMAIN

EXIST CMU PNL TO REMAIN

EXIST METAL

NEW GLASS

MAT GYP BD

WASH SANITIZE AND

DRY EXISTING WOOD

FRAMING, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN, ACRYLIC

LATEX PAINT

EXISTING CMU

WALL TO REMAIN

MIN.

0' - 2"

EXISTING TOP PLATE

AT PLUMBING WALL

WASH SANITIZE AND

DRY EXISTING CMU

WALL, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN,

ACRYLIC LATEX PAINT

REMOVE EXISTING

FIBERGLASS BATT

INSULATION AND

REPLACE WITH

CLOSED-CELL SPRAY

FOAM INSULATION

NEW TILE (CT-2)

AND GROUT TO

MATCH EXISTING

TILE AND GROUT IN

COLOR, TEXTURE,

AND PATTERN

NEW TILE (CT-2)

AND GROUT TO

MATCH EXISTING

TILE AND GROUT IN

COLOR, TEXTURE,

AND PATTERN

MTL OUTSIDE CORNER

TRANSITION STRIP

TO REMAIN

EXISTING ICF FOR KEYNOTE

SEE FLOOR PLAN

9'-3" AFF

CEILING

HEIGHT

FINSH FLOOR

EXISTING GYP

BD CEILING TO

REMAIN

NEW FRP

WALL BOARD

NEW GLASS MAT GYP

BD, SECURED TO ICF

INTERNAL WEB

WASH, SANITIZE AND

DRY INSULATION

SEE KEYNOTES

ON FLOOR PLAN

FOR CONDITION

AT OPPOSITE

WALL FACE

NEW 4" H TILE

BASE TRIM (CT-2)

AND GROUT TO

MATCH EXISTING

TILE AND GROUT IN

COLOR, TEXTURE,

AND PATTERN

6'-0" AFF

TILE WAINSCOT

FINSH FLOOR

NEW TILE (CT-1) AND

GROUT TO MATCH

EXISTING TILE AND

GROUT IN COLOR,

TEXTURE, AND

PATTERN

NEW FRP WALL

BOARD OVER NEW

GLASS MAT GYP BD,

SECURED TO ICF

INTERNAL WEB

NEW GLASS MAT GYP

BD, SECURED TO ICF

INTERNAL WEB

WASH, SANITIZE

AND DRY

INSULATION

SEE KEYNOTES

ON FLOOR PLAN

FOR CONDITION

AT OPPOSITE

WALL FACE

NEW 4" H TILE

BASE TRIM (CT-2)

AND GROUT TO

MATCH EXISTING

TILE AND GROUT IN

COLOR, TEXTURE,

AND PATTERN

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-501

W

AL

L D

ET

AI

LS

M

IS

SO

U

R I R

IV

ER

P R

O

JE

C T

O

FF

IC

E, N

EB

R

AS

KA

O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

EN

U

E O

M

AH

A, N

E

R . A

H

LE

R S

R . A

H

LE

R S

B.

G

O R

U P

B.

G

O R

U P

/1

8/

W

F-

-Q

-0

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

M R

PO

P

O

ST

F

LO

O D

R

EH

AB

IL

IT

AT

IO

N

(F Y1

9)

O D

_M

R

PO

.R

VT

G

EN

ER

AL

R

EV

IS

IO

N

S 3/

/2

1 1/2" = 1'-0"1 ICF W/ LINER PNL WSCT

1 1/2" = 1'-0"2 ICF W/ FULL HT LINER PNL

1 1/2" = 1'-0"7 GIRT PLANE W/ INT LINER PNL

1 1/2" = 1'-0"8 GIRT PLANE W/ EXT MTL PNL

1 1/2" = 1'-0"5 CMU W/ FURRED LINER PNL

1 1/2" = 1'-0"6 CMU W/ FURRED PLBG WALL

1 1/2" = 1'-0"4 ICF W/ FRP

1 1/2" = 1'-0"3 ICF W/ TILE

EXISTING STUD WALL

TO REMAIN

SEE FLOOR PLAN

FOR KEYNOTE

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

EXISTING GYP BD TO REMAIN

NEW STEEL STUD BLOCKING

AT WAINSCOT

SEE KEYNOTES ON FLOOR

PLAN FOR CONDITION AT

OPPOSITE WALL FACE

NEW LINER PANEL (LP-1)

WASH SANITIZE AND DRY EXISTING

WOOD FRAMING, PAINT WITH

WATER REPELLENT, VAPOR-OPEN,

ACRYLIC LATEX PAINT

EXISTING STUD WALL

TO REMAIN

SEE FLOOR PLAN

FOR KEYNOTE

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

NEW LINER PANEL (LP-1)

WASH SANITIZE AND DRY EXISTING

WOOD FRAMING, PAINT WITH

WATER REPELLENT, VAPOR-OPEN,

ACRYLIC LATEX PAINT

EXISTING GYP BD TO REMAIN

MIN.

0' - 2"

NEW STEEL STUD BLOCKING

AT WAINSCOT

SEE KEYNOTES ON FLOOR

PLAN FOR CONDITION AT

OPPOSITE WALL FACE

REMOVE EXISTING

FIBERGLASS BATT

INSULATION AND REPLACE

WITH CLOSED-CELL

SPRAY FOAM INSULATION

EXISTING BATT

INSULATION TO REMAIN

6'-0" AFF

TILE WAINSCOT

FINSH FLOOR

NEW GLASS MAT GYP BD

WASH SANITIZE AND DRY

EXISTING FRAMING

REMOVE EXISTING FIBERGLASS

BATT INSULATION AND REPLACE

WITH CLOSED-CELL SPRAY

FOAM INSULATION

NEW FRP WALL BOARD OVER

NEW GLASS MAT GYP BD

MIN.

0' - 2"

FOR KEYNOTE

SEE FLOOR PLAN

TO REMAIN

EXISTING STUD WALL

NEW TILE (CT-1) AND GROUT

TO MATCH EXISTING TILE

AND GROUT IN COLOR,

TEXTURE, AND PATTERN

SEE KEYNOTES ON FLOOR

PLAN FOR CONDITION AT

OPPOSITE WALL FACE

3'-0" AFF

SPRAY FOAM

INSULATION HEIGHT

NEW 4" H TILE BASE TRIM (CT-2)

AND GROUT TO MATCH EXISTING

TILE AND GROUT IN COLOR,

TEXTURE, AND PATTERN

4'-3 1/2" AFF

T.O. PLATE AT

PLUMBING WALL

FINSH FLOOR

NEW GLASS MAT GYP BD

WASH SANITIZE AND DRY

EXISTING WOOD FRAMING, PAINT

WITH WATER REPELLENT, VAPOR-

OPEN, ACRYLIC LATEX PAINT

REMOVE EXISTING

FIBERGLASS BATT INSULATION

AND REPLACE WITH CLOSED-

CELL SPRAY FOAM INSULATION

EXISTING BATT

INSULATION TO REMAIN

MIN.

0' - 2"

SEE FLOOR PLAN

FOR KEYNOTETO REMAIN

EXISTING STUD WALL

ALIGN T.O. TILE WAINSCOT TO

T.O. TILE AT PLUMBING WALL

NEW TILE (CT-2) AND GROUT

TO MATCH EXISTING TILE

AND GROUT IN COLOR,

TEXTURE, AND PATTERN

SEE KEYNOTES ON FLOOR

PLAN FOR CONDITION AT

OPPOSITE WALL FACE

EXISTING GYP

BD TO REMAIN

TO REMAIN

EXISTING STUD WALL

FOR KEYNOTE

SEE FLOOR PLAN

9'-3" AFF

CEILING

HEIGHT

FINSH FLOOR

EXISTING GYP BD

CEILING TO REMAIN

NEW FRP WALL BOARD

NEW GLASS MAT GYP BD

WASH SANITIZE

AND DRY EXISTING

FRAMING

SEE KEYNOTES ON

FLOOR PLAN FOR

CONDITION AT

OPPOSITE WALL FACE

NEW 4" H TILE BASE TRIM

(CT-2) AND GROUT TO

MATCH EXISTING TILE

AND GROUT IN COLOR,

TEXTURE, AND PATTERN

3'-0" AFF

WAINSCOT HEIGHT

FINSH FLOOR

EXISTING GYP

BD TO REMAIN

NEW STEEL STUD

BLOCKING AT

WAINSCOT

SEE KEYNOTES ON FLOOR

PLAN FOR CONDITION AT

OPPOSITE WALL FACE

NEW LINER PANEL (LP-2)

WASH SANITIZE AND DRY

EXISTING WOOD FRAMING

AND LATH, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN, ACRYLIC

LATEX PAINT

AND LATH TO REMAIN

EXISTING STUD WALL

FOR KEYNOTE

SEE FLOOR PLAN

WASH SANITIZE

AND DRY EXISTING

CONCRETE CURB

3" 1' - 3" 5/8"

TO REMAIN

EXISTING ICF FOR KEYNOTE

SEE FLOOR PLAN

9'-3" AFF

CEILING HEIGHT

FINSH FLOOR

EXISTING GYP BD

CEILING TO REMAIN

NEW FRP WALL BOARD

NEW GLASS MAT GYP

BD, SECURED TO ICF

INTERNAL WEB

WASH, SANITIZE AND

DRY INSULATION

SEE KEYNOTES ON

FLOOR PLAN FOR

CONDITION AT

OPPOSITE WALL FACE

NEW 4" H TILE BASE

TRIM (CT-2) AND GROUT

TO MATCH EXISTING

TILE AND GROUT IN

COLOR, TEXTURE, AND

PATTERN, OVER GLASS

MAT GYP BD

0'

4"

NEW PLYWOOD AND

BLOCKING, AS

REQUIRED, PAINT WITH

WATER REPELLENT,

VAPOR-OPEN, ACRYLIC

LATEX PAINT, ALL SIDES

RE-INSTALL EXISTING

LOCKERS ON NEW BASE,

WITH APPROPRIATE

WALL ANCHORS

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

A-502

W

AL

L D

ET

AI

LS

M

IS

SO

U

R I R

IV

ER

P R

O

JE

C T

O

FF

IC

E, N

EB

R

AS

KA

O

M

AH

A D

IS

TR

IC

T

C

AP

IT

O

L

AV

EN

U

E O

M

AH

A, N

E

R . A

H

LE

R S

R . A

H

LE

R S

B.

G

O R

U P

B.

G

O R

U P

/1

8/

W

F-

-Q

-0

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

M R

PO

P

O

ST

F

LO

O D

R

EH

AB

IL

IT

AT

IO

N

(F Y1

9)

O D

_M

R

PO

.R

VT

G

EN

ER

AL

R

EV

IS

IO

N

S 3/

/2

1 1/2" = 1'-0"9 STUD WALL W/ LINER PNL

1 1/2" = 1'-0"10 INSUL STUD WALL W/ LINER PNL

1 1/2" = 1'-0"11 STUD WALL W/ 6'-0" H TILE

1 1/2" = 1'-0"12 STUD WALL W/ 4'-3 1/2" H TILE

1 1/2" = 1'-0"13 STUD WALL W/ FRP

1 1/2" = 1'-0"14 STUD WALL W/ LATH & LINER PNL

1 1/2" = 1'-0"15 LOCKER INSTALLATION

MRPOA-111
MRPOA-112
MRPOA-501
MRPOA-502