| Am_0001.pdf | ||
| W9128F-16-R-0090_DRAWINGS_NORTH_GATE.PDF | ||
| W9128F-16-R-0090_DRAWINGS_SOUTH_GATE.PDF | ||
| W9128F-16-R-0090_USAFA_Front_Gate-Specs.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE
2. AMENDMENT/MODIFICAITON NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicble)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICIATION NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a)By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPIRATION DATA (If required)
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc. ) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION ( Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
Amendment No. 0005 Aug 12, 2016
U.S ARMY CORPS OF ENGINEERS, OMAHA DISTRICT
CONTRACTING OFFICE
1616 CAPITOL AVE.
OMAHA, NE 68102-4901
See Item 6
W9128F-16-R-0090
Jul 8, 2016
FRONT GATES FORCE PROTECTION, XQPZ 09 4013, USAF ACADEMY, COLORADO
See attached documentation for content of the amendment revisions
Date for receipt of Proposals is 25 AUG 2016 at 1400 hours
Government Point of Contact: Donna Larson(402) 995-2066
8/12/2016
Am #0005 - 1
Am #0005 - 2 (Continuation of SF30)
DEPARTMENT OF THE ARMY
Omaha District, Corps of Engineers
1616 Capitol Avenue Omaha, Nebraska 68102-4901
:NOTICE: Failure to acknowledge : Solicitation No. W9128F-16-R-0090 :all amendments may cause rejec-:
:tion of the offer. See FAR : Date of Issue: 8 JUL 2016 :52.215-1 of Section 00 21 00. : Date of Receiving Proposals:
25 AUG 2016
Amendment No. 0005
12 AUG 2016
SUBJECT: Amendment No. 0005 to Request for Proposal Specifications and Drawings for Design and Construction of Front Gates Force Protection.
TO: Prospective Offerors and Others Concerned
1. The specifications and drawings for subject project are hereby modified as follows (revise all specification indices, attachment lists, and drawing indices accordingly).
a. Specifications. (Descriptive Changes)
(1) Section 01 33 00.36, Page 4, paragraph 1.2 delete the reference “UFC 3-240-07FA Sanitary and Industrial Wastewater Collection” and substitute the following:
“UFC 3-240-01 (2012; Change 1 2014) Wastewater Collection”
(2) Section 01 33 00.38, Pages 4-5, paragraph 1.2 delete the reference “UFC 3-240-07FA Sanitary and Industrial Wastewater Collection” and substitute the following:
“UFC 3-240-01 (2012; Change 1 2014) Wastewater Collection”
(3) Section 01 82 00, Page 2, paragraph 1.1 delete the reference “UFC 3-400-01 Design: Energy Conservation, 5 Jul 02” and substitute the following:
“UFC 1-200-02 (2013, with Change 3) High Performance and Sustainable Building Requirements”
(4) Section 01 82 00, Page 3, paragraph 1.1 delete the reference “UFC 4-020-04A Security Engineering: Electronic Security Systems”.
(5) Section 01 82 00, Page 6, paragraph 1.6.1 delete the last sentence of the first paragraph “Reference UFC 3-400- 01...Additional Design Criteria.” and substitute the following:
“Reference UFC 1-200-02 High Performance and Sustainable Building Requirements for additional design criteria.”
Am #0005 - 3
(6) Section 01 86 26, Page 4, paragraph 1.1.1 delete the reference “UFC 3-400-01 Design: Energy Conservation” and substitute the following:
“UFC 1-200-02 (2013, with Change 3) High Performance and Sustainable Building Requirements”
(7) Section 01 86 26, Page 4, paragraph 1.1.1 delete the reference “UFC 4-020-04A Electronic Security Systems” and substitute the following:
“UFC 4-020-02 (2013) Electronic Security Systems”
(8) Section 01 88 00, Page 3, paragraph 1.3 delete the sentence “All building security...UFC 4-02-04A.” and
“All building security systems will be designed in accordance with MIL HDBK 1013/1A and UFC 4-021-02.”
(9) Section 01 89 00, Page 17, paragraph 1.12.1 delete the first sentence “Determination of peak...UFC 3-230-17FA.” and
“Determination of peak discharges for smaller drainage areas shall be accomplished using either the Rational Method or the modified Rational Method.”
(10) Section 01 89 00, Page 23, paragraph 1.15.3.1 delete the second sentence “If the Federal...UFGS guide specifications.”
and substitute the following:
“If the Federal standards are more stringent, the sewage system shall be designed and constructed in accordance with UFC 3-240-01 and applicable UFGS guide specifications.”
b. Specifications (New and/or Revised and Reissued). Delete and substitute or add specification pages as noted below. The substituted pages are revised and reissued with this amendment.
Pages Deleted Pages Substituted or Added
None
c. Drawings (Not Reissued). None
d. Drawings (Reissued). The following drawing(s) are revised with a revision date as indicated in the title block, and reissued with this amendment.
(1) Sheet C-100A, SITE LAYOUT PLAN, NORTH GATE
2. This amendment is a part of the proposing papers and its receipt shall be acknowledged on the Standard Form 1442. All other conditions and requirements of the request for proposal remain unchanged. If the proposals
Am #0005 - 4 have been mailed prior to receiving this amendment, you will notify the office where proposals are received, in the specified manner, immediately of its receipt and of any changes in your proposal thereby occasioned.
a. Hand-Carried Proposals shall be delivered to the U.S. Army Corps of Engineers, Omaha District, Contracting Division, 1616 Capitol Avenue, Omaha, Nebraska 68102-4901.
b. Mailed Proposals shall be addressed as noted in Item 8 on Page 00 10 00-1 of Standard Form 1442.
3. Offers will be received until 2:00 p.m, local time at place of receiving proposals, 25 AUG 2016.
Attachments:
Drawings as listed in 1.d. above
U.S. Army Corps of Engineers, Omaha District 1616 Capitol Avenue Omaha, Nebraska 68102-4901
12 AUG 2016
NEP/2160
FLAG NOTES
PLACE CULVERT UNDER DRIVE (OPTION)8.
(OPTION)
REPLACE ASPHALT IN HATCHED AREA WITH CONCRETE PAVEMENT 7.
PROPOSED POV SHELTER - DRIVER WAITING AREA.6.
NOT USED.5.
PROPOSED CANOPY AND POV INSPECTION STRUCTURE ROOF LINE.4.
DRAWINGS.
PROPOSED STRUCTURAL CANOPY SUPPORT WALLS. RE: ARCHITECTURAL 3.
PROPOSED CONCRETE VERTICAL CURB AND GUTTER.2.
CONSTRUCT ASPHALT PAVING WHERE SHOWN.1.
GENERAL NOTES
REFER TO THE UTILITY PLAN.
18" CLEARANCE FOR PROPOSED UTILITY CROSSINGS AS REQUIRED.
CONTRACTOR SHALL LOWER EXISTING WATERLINES TO ALLOW MINIMUM
IMPROVEMENT AREAS OR UTILITY CROSSINGS AS REQUIRED.
CONTRACTOR SHALL RELOCATE EXISTING UTILITIES AT PROPOSED 6.
AND CONSTRUCTION.
CONTRACTOR SHALL POT-HOLE EXISTING UTILITIES PRIOR TO DESIGN 5.
DURING CONSTRUCTION.
CONTRACTOR SHALL PROVIDE AND IMPLEMENT A TRAFFIC CONTROL PLAN 4.
VEGETATION.
SEED MIX REQUIREMENTS AND RE-ESTABLISHMENT OF NATIVE
REFER TO THE LANDSCAPE PLANS AND SPECIFICATIONS FOR PLANTINGS, 3.
COMPLETION OF CONSTRUCTION.
CLEARED AREAS AND TO RE-ESTABLISH NATIVE GRASSES AT THE
THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE DUST CONTROL OF
STAGING AREA SHOWN. WITH THE USAFA PRIOR TO CONSTRUCTION. IT IS
THE CONTRACTOR SHALL COORDINATE THE USE OF THE CONTRACTOR 2.
AND REMOVAL INFRASTRUCTURE COORDINATION.
REFER TO THE SITE AND UTILITY PLANS FOR PROPOSED IMPROVEMENTS 1.
UPON IMPACT.
EXCAVATION THAT ARE CAPABLE OF DEFLECTING AN ERRANT VEHICLE
PROVIDE CRASHWORTHY TEMPORARY TRAFFIC BARRIERS AROUND THE
AS PART OF THE TRAFFIC SAFETY MEASURES THE CONTRACTOR SHALL
REQUIREMENT FOR EXCAVATION IN CLOSE PROXIMITY TO TRAVEL LANES,
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). DUE TO THE
CONTROL SHALL BE IN ACCORDANCE WITH ALL REQUIREMENTS OF THE
CONTRACTOR SHALL MAINTAIN TRAFFIC SAFETY AT ALL TIMES. TRAFFIC8.
REGARD TO TEMPERATURE, RATE, VOLUME, AND DURATION OF FLOW."
FEASIBLE, THE PREDEVELOPMENT HYDROLOGY OF THE PROPERTY WITH
MUST "MAINTAIN OR RESTORE, TO THE MAXIMUM EXTENT TECHNICALLY
THESE REQUIREMENTS, FEDERAL FACILITY PROJECTS OVER 5,000 SF
FEDERAL DEVELOPMENT AND REDEVELOPMENT PROJECTS. UNDER
SECTION 438 ESTABLISHES INTO LAW NEW STORM WATER DESIGN FOR
OF THE ENERGY INDEPENDENCE AND SECURITY ACT (EISA). EISA
IMPLEMENTATION OF STORM WATER REQUIREMENTS UNDER SECTION 438
THE STORM WATER MANAGEMENT DESIGN SHALL COMPLY WITH THE DoD 7.
CONSTRUCTION LIMITS
CONTRACTOR STAGING AREA
PREBLES MEADOW
JUMPING MOUSE HABITAT
BOUNDARY
CONSTRUCTION LIMITS
NORTH G
ATE
BLVD.
E
T T
EE
W
T
T
FO
E AC
EE
FO
8 1
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
2 3 4 5 6 7 8 9
F
E
D
C
B
A
10 11
G
H
O M
A H
A D
IS
T R
IC
T
O M
A H
A
N E
B R
A S
K A
J U
N E
A R
C H D
U S A
IR
F
O R
C E A
C A
D E
M Y
C O
L O
R A
D O
F R
O N
T G
A T
E S F
O R
C E P
R O
T E
C T
IO
N
C A
N O
P Y D
E S
IG
N
Omaha District of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
W F -1
-R -0
F
IL
E N
U M
B E
R
N
SCALE: 1"=30'
15 30 60
D M
B
A F -5
-0
A A
C -1
A .d w g
C-100A
IT
E L
A Y
O U
T P
L A
N
N O
R T
H G
A T
E
/1
/2
G E
N E
R A
L R
E V
IS
IO
N
| Standard_Form_30 |
| Am_0005_Narrative |
| AA39C-100A |
File details come from the government source that posted it. Updated .