A.07.24_Amendment_0002_16R0012.pdf

PDF 260 KB Posted

Attached to
Field Office Repairs & Additions Federal contract opportunity
Solicitation number
W9127S-16-R-0012
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Amendment 0002

View the file

Other files for this federal contract opportunity

Other files attached to Field Office Repairs & Additions, newest first.
File Type Posted
A.07.24_Amendment_0001_16R0012.pdf PDF
A.01.13_Drawings_16R0012.pdf PDF
A.07.23_Solicitation_16R0012.pdf PDF
A.01.29_Specifications_16R0012.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to revise the bid schedule, revise section 01 22 00.00 10 of the specifications, & revise the draw ings. All other terms and conditions remains the same.

1. CONTRACT ID CODE PAGE OF PAGES

1 5

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 19-Aug-2016

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9127S-16-R-0012

X 9B. DATED (SEE ITEM 11)

29-Jul-2016

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 2 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

19-Aug-2016

CODE

CONTRACTING DIVISION

USACE, LITTLE ROCK (W9127S)

700 W. CAPITOL AVE, RM 7315

LITTLE ROCK AR 72201-3225

W9127S 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

PN456018

Field Office Repairs and Addition Toad Suck Ferry Field Office, MKARNS Faulkner County, Arkansas

SECTION B

BIDDING SCHEDULE

AM0002

(To be attached to SF 1442)

SOLICITATION NUMBER W9127S-R-16-0012

Line Item No.

Description Estimated Quantity

Unit Measure

Unit Price Amount

Renovate Existing Office Space And Construct A New Addition To The Existing Toad Suck Field Office Building And Incidental Related Work

1 Job XXX $__________

0002 Electrical Service Rack 1 Job XXX $__________

Overexcavate And Backfill Under New Foundation - One (1) Foot In Depth Measured From Bottom Of Adjacent Foundation Member For Entire New Building Addition and Atrium.

135 SY XXX $__________

TOTAL BASE BID $__________

SECTION 01 22 00.00 10

(AM0002) AUG 20116

PRICE AND PAYMENT PROCEDURES

08/15

PART 1 GENERAL

1.1 SINGLE JOB PAYMENT ITEMS

Payment items for the work of this contract for which contract job payments will be made are listed in the BIDDING SCHEDULE and described below. All costs for items of work, which are not specifically mentioned to be included in a particular job or unit price payment item, are included in the listed job item most closely associated with the work involved. The job price and payment made for each item listed constitutes full compensation for furnishing all plant, labor, materials, and equipment, and performing any associated Contractor quality control, environmental protection, meeting safety requirements, tests and reports, and for performing all work required for which separate payment is not otherwise provided.

1.1.1 Renovate Existing Office Space and Construct a New Addition to the existing Toad Suck Field Office Building and Incidental Related Work

1.1.1.1 Payment

Payment will be made for costs associated with renovations and addition to the existing field office building at Toad Suck Ferry to include office spaces, meeting/break room and an atrium. The work shall include construction of concrete footings, wood stud walls, brick veneer exterior and an asphalt shingle roof supported by a wood deck and pre-engineered wood trusses. The work will include service utilities excluding electrical service rack.

1.1.1.2 Unit of Measure

Unit of measure: job.

1.1.2 ELECTRICAL SERVICE RACK

1.1.2.1 PAYMENT

Payment will be made for costs associated with electrical service rack, The work shall include panel board, rack, mater can, concrete for service rack, ground rod, conduit and wire to pad mount.

1.1.2.2 UNIT OF MEASURE: JOB

1.2 UNIT PRICE PAYMENT ITEMS

Payment items for the work of this contract on which the contract unit price payments will be made are listed in the BIDDING SCHEDULE and described below. The unit price and payment made for each item listed constitutes full compensation for furnishing all plant, labor, materials, and equipment, and performing any associated Contractor quality control, environmental protection, meeting safety requirements, tests and reports, SECTION 01 22 00.00 10 Page 1 and for performing all work required for each of the unit price items.

1.2.1 Overexcavate And Backfill Under New Foundation - One (1) Foot In Depth Measured From Bottom Of Adjacent Foundation Member For Entire New Building Addition and Atrium.

1.2.1.1 Payment

Payment will be made for costs associated with overexcavate and backfill under new foundation for entire foundation of the new building addition and atrium. The work shall include overexcavation of unsuitable material to a depth of one foot below the foundation, haul and dispose of excavated material offsite, provide select fill material in accordance with the Structural Notes on Sheet S-001 of the Plans, and all incidentals required to provide overexcavate and backfill under new foundation for entire foundation of the new building addition and atrium.

1.2.1.2 Unit of Measure

Unit of measure: square yard.

PART 2 PRODUCTS

Not Used

PART 3 EXECUTION

Not Used -- End of Section --

SECTION 01 22 00.00 10 Page 2 of Engineers

US Army Corps

Little Rock District fi

M M

E

C A

T

D a te

E P

H

B

SCALE: 3"=1’-0"

SECONDARY FEEDER TRENCHING DETAIL

E L E

C T

R

IC

A L D

E T

A

IL

S I I

SAND

SAND

COMPACTED BACKFILL

CONDUITS AS REQUIRED.

PROVIDE NUMBER OF

CONDUITS TYPICAL.

24"

0 2’ 4’ 6’

0 3" 6" 9" 12"

METALLIC CORE

MARKING TAPE WITH

A

SCALE: 3/8"=1’-0"

PADMOUNT TRANSFORMER

WALL

ATTIC

CABINET

TELECOM

HOMERUN

FLOOR

C

SCALE: NTS

SECTION VIEW - NEW TELECOM CABINET

GROUNDING CABLE

DATA CABLES

INSULATED BUSHING (ALL CONDUITS)

SURGE STRIP (POWER)

CONDUITS

E-502.1

A

U G

R E

V

IS

E D

IA

W

A M

M E

N D

M E

N T

Drawing Ref. No.

10935-62/

S u b m it te d b y

R e v ie w e d b y

D ra w n b y

D e s ig n e d b y

D a te

S o li c it a ti o n N o

W S -1

-R -0

C o n tr a c t

N o

S

Y T

IM

E

D G

N S

P E

C

U S

E R

N A

M E

C h ie f, G e n e ra l E n g in e e ri n g S e c ti o n

B

Serial No.

Drawing Code/

L

IT

T L E R

O C

K

A R

K A

N S

A S

L

IT

T L E R

O C

K D

IS

T R

IC

T

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R S

D A

T E

A C

T

IO

N D

E S

C R

IP

T

IO

N M

A R

K T

R A

C K

IN

G N

O

1 2 3 4 5 6

A

C

D

E

1 2 3 4 5 6

F A

U L

K N

E R C

O U

N T

Y

A R

K A

N S

A S

N A

V

IG

A T

IO

N S

Y S

T E

M

M c C

L E

L L

A N -K

E R

R A

R K

A N

S A

S R

IV

E R

T O

A D S

U C

K F

E R

R Y

F

IE

L D O

F F

IC

E R

E P

A

IR

S A

N D A

D D

IT

IO

N

J U

N E

PEDESTAL

GROUND PEDESTAL

1’

CONDUIT OR CABLE

TOP VIEW

LONGER THAN CONDUIT

CABLE AT LEAST 5 FT.

CAPPED SECONDARY

PULLING TAPE OR

BRING CABLE OR CONDUIT TO ONE FOOT FROM THE CENTER OF THE PEDESTAL BURIED AT 30" BELOW THE GROUND.

STREET SIDE

PROVIDED BY ENTERGY

RACK

SERVICE

80 REQUIRED.)

(IF PVC, SCHED.

FACTORY BEND

36" RADIUS MIN.

GROUND LEVEL.

BELOW

WITH OR

TO BE FLUSH

GROUND ROD

UPPER END OF

AND CLAMP.

GROUND ROD

COPPER CLAD

3/4" X 10’-0"

PAD OR SECONDARY PEDESTAL.

WITH 2’-0" OF THE TRANSFORMER

PROVIDED BY ENTERGY LOCATED

CONDUIT SYSTEM THAT IS

FLAGGING TAPE AND TIE INTO THE

THE CUSTOMER WILL FIND THE RED

M

IN

2’-0"

BY ENTERGY.

PEDESTAL IS SUPPLIED BY THE CONTRACTOR AND INSTALLED

(ALT LEAST 5 EXTRA FEET) AND THE ELBOW TO ENTER THE

PULLING TAPE MUST BE LONG ENOUGH TO REACH PEDESTAL

FOR CONTRACTOR INSTALLED AND SUPPLIED CONDUIT,

EXTRA FEET).

REACH THE CONNECTORS IN THE PEDESTAL ( AT LEAST 5

FOR DIRECT BURIED, CABLE MUST BE LONG ENOUGH TO

BY ENTERGY).

TRANSFORMER (OWNED

EXISTING PAD MOUNT

00_BID SCHEDULE (AM0002).pdf
100%