DATASHEET
Modbus Master/Slave Communication Module
MVI56E-MCM/MCMXT
The MVI56E Communication Module allows for Modbus Master and/or Slave connectivity from Rockwell Automation® ControlLogix® processors to Modbus RTU/ASCII devices. Each MVI56E port can be configured as a Master or Slave.
The MVI56E-MCM and MVI56E-MCMXT act as input/output modules on the ControlLogix backplane, making Modbus data appear as I/O data to the processor.
Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT™ control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures, and has conformal coating to protect it from harsh or caustic conditions.
Features Benefits
Backward Compatibility
All MVI56E products are backward-compatible with earlier MVI56 modules allowing direct replacement without the need to change existing controller programs
10,000 Word Database Allows you to gather more data from your devices, which improves operational performance
Enjoy Enhanced features and flexibility without incurring expensive reprogramming costs
Add-On Instruction Module configuration stored within the RSLogix™ 5000 project (ACD file)
No additional programming or configuration software is required
Add-On Instruction for RSLogix 5000 version 16 or higher cuts development time and costs
CIPconnect® Enabled Facilitates remote user access across the ControlLogix backplane through Rockwell Automation’s 1756-ENBT module
Configure, diagnose, and analyze process data and communications status
Bridge through multiple ENBT/CNBT links to connect to MVI56E-MCMs installed in remote chassis for configuration and diagnostics
Add-On Profile Simplifies adding the module in an RSLogix 5000 project
Configuration
The module configuration is defined in the Add on Instruction. The AOI is fully commented, and includes user-defined data types, ladder rungs and controller tags. The AOI can be used without modification for most application.
The MVI56E-MCM User Manual and sample configuration provide a quick and easy example with step-by-step instructions on how to move data through the module from the Modbus network to the processor.
General Specifications Backward-compatible with previous MVI56-MCM version
Single Slot - 1756 ControlLogix® backplane compatible
10/100 MB Ethernet port for network configuration and diagnostics with Auto Cable Crossover Detection
User-definable module data memory mapping of up to 10,000 16-bit registers
4-character, scrolling, alphanumeric LED display of status and diagnostic data in plain English
ProSoft Discovery Service (PDS) software finds the module on the network and assigns a temporary IP address to facilitate module access
Supports RIUP (Remove and Insert Under Power)
Functional Specifications The MVI56E-MCM will operate on a Local or Remote rack (For remote rack applications with smaller data packet size please refer to the MVI56E-MCMR product)
Supports Enron version of Modbus protocol for floating-point data transactions
PCB includes powerful Modbus network analyzer
Special functions (command control, event commands, status, and so on) are supported by message transfer (unscheduled) using the MSG instruction
Error codes, network error counters, and port status data available in user data memory
Slave Specifications The MVI56E-MCM module accepts Modbus function code commands of 1, 2, 3, 4, 5, 6, 8, 15, 16, 17, 22, and 23 from an attached Modbus Master unit. A port configured as a Modbus Slave permits a remote Master to interact with all data contained in the module.
This data can be derived from other Modbus Slave devices on the network, through a Master port, or from the ControlLogix processor.
Master Specifications A port configured as a virtual Modbus Master device on the MVI56E-MCM module actively issues Modbus commands to other nodes on the Modbus network. Up to 325 commands are supported on each port. Additionally, the Master ports have an optimized polling characteristic that polls Slaves with communication problems less frequently.
The ControlLogix processor ladder logic can issues commands directly from ladder logic or actively select commands from the command list to execute under ladder logic control.
ControlLogix™ Modbus Integration
General Modbus Specifications Communication Parameters
Baud Rate: 110 baud to 115.2 kbps Stop Bits: 1 or 2 Data Size: 7 or 8 bits Parity: None, Even, Odd RTS Timing delays: 0 to 65535 milliseconds
Modbus Modes RTU mode (binary) with CRC-16 ASCII mode with LRC error checking
Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations
Modbus Function Codes 1: Read Coils Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Register 8: Diagnostics 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Data Registers 17: Report Slave ID 22: Mask Write 4x Register 23: Read/Write 4x Registers
Modbus Master Specifications Command List Up to 325 commands per Master port, each fully configurable for function code, slave address, register to/from addressing and word/bit count.
Optimized Polling Configuration options allow Master ports and commands to be optimized to poll slaves with communication problems less frequently.
Command Status/Error Monitoring
Command Status or Error codes are generated for each command as it executes, allowing careful monitoring of communication health between the Master and its Slaves.
Slave Polling Control Master Port maintains a Slave Status list of all network Slaves. Polling of each Slave may be disabled and enabled using this list.
Modbus Slave Specifications Full Memory Access A port configured as a Modbus Slave permits a remote
Master to read from or write to any of the 10,000 registers that make up the user memory database.
Multi-source Slave Data Data presented at the Slave port can be derived from other Modbus Slave devices on a different network through the module’s Master port or from the processor tag database.
Node Address 1 to 247 (software selectable)
Status Data Slave port error codes, counters and statuses are available separately for each port when configured as a Slave
Where Automation Connects™
Global Distribution
ProSoft Technology® products are distributed and supported worldwide through a network of over 500 distributors in over 50 countries.
Our knowledgeable distributors are familiar with your application needs.
For a complete list of distributors, go to our web site at:
www.prosoft-technology.com
Global Support
We are there for you
All ProSoft Technology products are backed with free technical support.
Contact our worldwide Technical Support team directly by phone or email.
Global Offices
We are where you are
ProSoft Technology has regional offices worldwide available to help you with all your industrial application needs. If you need help choosing a ProSoft Technology solution for your particular application check out our contact information under distributor sales on the web site at:
Whether your application is large or small, our technical professionals are there to help you choose the right communication solution.
Hardware Specifications
General
Specification Description
Backplane Current Load 800 mA @ 5 VDC 3 mA @ 24 VDC
Operating Temperature 0°C to 60°C (32°F to 140°F) - MVI56E-MCM
-25°C to 70°C (-13°F to 158°F) - MVI56E-MCMXT
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Extreme/Harsh Environment MVI56E-MCMXT comes with conformal coating
Shock 30 g operational 50 g non-operational Vibration: 5 g from 10 to 150 Hz
Relative Humidity 5% to 95% (without condensation)
LED Indicators Battery Status (ERR) Application Status (APP) Module Status (OK)
4-Character, Scrolling, Alpha- Numeric LED Display
Shows Module, Version, IP, Port Master/Slave Setting, Port Status, and Error Information
Debug/Configuration Ethernet port (E1 - Config)
Ethernet Port 10/100 Base-T, RJ45 Connector, for CAT5 cable
Link and Activity LED indicators
Auto-crossover cable detection
Serial Application ports (P1 & P2)
Full hardware handshaking control, providing radio, modem, and multi-drop support
Software configurable communication parameters
Baud rate: 110 baud to 115.2 kbps RS-232, 485 and 422 Parity: none, odd or even Data bits: 5, 6, 7, or 8 Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds
Serial Applications Ports
(P1, P2)
RJ45 (DB-9M with supplied adapter cable) Configurable RS-232 hardware handshaking 500V Optical isolation from backplane
RS-232, RS-422, RS-485 jumper-select, each port
RX (Receive) and TX (Transmit) LEDs, each port
Shipped with Unit RJ45 to DB-9M cables for each serial port
Agency Approvals & Certifications
Please visit our website: www.prosoft-technology.com
Additional Products
ProSoft Technology® offers a full complement of hardware and software solutions for a wide variety of industrial communication platforms. For a complete list of products, visit our web site at:
Ordering Information
To order this product, please use the following:
Modbus Master/Slave Communication Module for ControlLogix®
MVI56E-MCM or MVI56E-MCMXT
To place an order, please contact your local ProSoft Technology distributor. For a list of ProSoft Technology distributors near you, go to:
www.prosoft-technology.com and select How to Buy from the menu.
Copyright © 2019 ProSoft Technology, Inc.
All rights reserved. 8/1/2019
Specifications subject to change without notice.
http://www.prosoft-technology.com/