W9127N-17-R-0069_Drawing_Set.pdf
PDF 34 MB Posted
- Attached to
- Fall Creek Fish Facility Pipe Lining Federal contract opportunity
- Solicitation number
- W9127N-17-R-0069
About this file
W9127N-17-R-0069 Drawing Set
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9127N-17-R-0069_FCFF_Pipe_Lining_-_Amendment_0002_SF30.pdf | ||
| W9127N-17-R-0069_FCFF_Pipe_Lining_-_Amendment_0002_Specs_Package.pdf | ||
| Site_Visit_Sign-In_Sheets.pdf | ||
| Additional_Solicitation_Attachments.pdf | ||
| W9127N17R00690001_-_Bidder_Inquiry_Key_Amendment.pdf | ||
| W9127N-17-R-0069_Specs_Package_-_Final.pdf | ||
| For_Info_Only_-_Additional_Drawings.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING PLOT SIZE: ANSI F
D
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
BORDER VERSION UPDATE [08-2013]
G-001SHEET NAME:G2ECDJTH BY USERNAME:DATE AND TIME PLOTTED: 5/12/2017 1:13:20 PM
NOTES:
/0
/2
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
P O
R T
L A
N D D
IS
T R
IC
T
PORTLAND DISTRICT
M
A T
T H
E W D
H A
N S
O N P .E
A N
S I F
F L F .1
G -0
X X
X .d g n
G E
C D J
H
G-001
:1
F
L L C
R E
E K D
A M A
N D R
E S
E R
V O
IR
W
N -1
-R -0
W
N -1
-C -0
GENERAL PLANS
CIVIL/ GEOTECH / LANDSCAPE PLANS
D R
A W
IN
G I
N D
E X
MARK
REVISION
FILE NAME
ID
SHEET
DRAWING TITLE
No.
ACTION
SHEET
GENERAL NOTES
PROJECT SITE MAP
DRAWING INDEX
G-003
G-002
G-001
FLF1.101_G-003XXX.DGN
FLF1.101_G-002XXX.DGN
FLF1.101 G-001XXX.DGN
FLF1.101 C-001XXX.DGN C-001 PIPE LINING PLAN DRAWING
INFORMATIONAL DRAWINGS
P
IP
E L
IN
IN
G F
IS
H F
A C
IL
IT
Y W
A T
E R S
U P
P L
Y
G E
C D J T
H
MECHANICAL FRAMING PLAN AT DISCHARGE
MECHANICAL FRAMING PLAN
FISH HORN DISCHARGE ELEVATION
FISH HORN DISCHARGE PLAN
FISH HORN DISCHARGE ISOMETRIC ARRANGEMENT
FISH HORN VALVES ELEVATION
FISH HORN VALVES PLAN
FISH HORN VALVES
OVERALL PLAN VIEW
ASSEMBLY DRAWING - PLATE
ASSEMBLY DRAWING - PLATE
FISH HORNS AND SUPPORTS
GRATING AND DETAILS FRAMING PLAN
STRUCTURAL FRAMING PLAN AT EL 800
STRUCTURAL FRAMING PLAN AT EL 765
STRUCTURAL FRAMING PLAN AT EL 720
EXISTING FISH HORN STRUCUTRES AND SUPPORTS
GENERAL STRUCTURAL NOTES AND PHOTOS
DOWNSTREAM MIGRANT FACILITY GENERAL PLAN AND SECTIONS
DOWNSTREAM MIGRANT FACILITY GENERAL PLAN AND SECTIONS
DOWNSTREAM MIGRANT FACILITY GENERAL PLAN AND SECTIONS
NEW FWS CONNECTION ISOMETRIC VIEW
DOWNSTREAM MIGRANT FACILITY PLAN AND SECTIONS
DOWNSTREAM MIGRANT FACILITY PLANS AND SECTIONS
DOWNSTREAM MIGRANT FACILITY GENERAL PLAN AND SECTIONS
FISH HORNS AND SUPPORTS SHEET 3
FISH HORNS AND SUPPORTS SHEET 2
FISH HORNS AND SUPPORTS SHEET 1
DOWNSTREAM MIGRANT FISH FACILITY VENT PIPE STRUCTURE
REGUALTING OUTLET CONDUIT SECTIONS AND DETAILS
REGULATING OUTLET CONDUIT PLAN AND PROFILE
INTAKE STRUCTURE PLANS AND SECTIONS
REGULATING OUTLET AND FISH FACILITIES GENERAL PLAN
E2002
E2001
MB201
MB101
MB001
MA201
MA101
MA001
M-002
SZ012
SZ011
S-010
S-009
S-008
S-007
S-006
S-005
S-001
C-004
C-003
C-002
MP101
FLD-3-3
FLD-3-2
FLD-3-1
FLD-2-37
FLD-2-36
FLD-2-35
FLD-2-32
FLD-2-13
FLD-2-12
FLD-2-9
FLD-2-8
E2002.pdf
E2001.pdf
MB201.pdf
MB101.pdf
MB001.pdf
MA201.pdf
MA101.pdf
MA001.pdf
M-002.pdf
SZ012.pdf
SZ011.pdf
S-010.pdf
S-009.pdf
S-008.pdf
S-007.pdf
S-006.pdf
S-005.pdf
S-001.pdf
C-004.pdf
C-003.pdf
C-002.pdf
FLF1.101_MP101XXX.DGN
FLD-3-3.TIF
FLD-3-2.TIF
FLD-3-1.TIF
FLD-2-37.TIF
FLD-2-36.TIF
FLD-2-35.TIF
FLD-2-32.TIF
FLD-2-13.TIF
FLD-2-12.TIF
FLD-2-9.TIF
FLD-2-8.TIF
SET ARE INTENDED TO BE PRINTED IN COLOR.
4. ALL SHEETS IN THE PLANS AND SPECIFICATION DRAWING
3. FIO DRAWINGS ARE ON FALL CREEK DATUM (NGVD 29).
2. FIO DENOTES "FOR INFORMATION ONLY"
FIO DRAWING IS FOR REFERENCE ONLYDENOTESe
FOLLOWING CONTRACT DRAWINGS
FIO DRAWING WAS REFERENCED BY THEDENOTESd
CONTRACT
FOLLOWING DRAWINGS AT THE COMPLETION OF THIS
FIO DRAWING WILL BE SUPERCEDED BY THEDENOTESc
CONTRACTOR
THE COMPLETION OF THIS CONTRACT BY THE
DRAWING SHALL BE UPDATED ATDENOTESb
COMPLETION OF THIS CONTRACT
FIO DRAWING IS OBSELETE AT THEDENOTESa
SHOWN BELOW:
1. SHEET ACTION NUMBER IDENTIFICATION KEY SHALL BE AS
G E
C D
M
H
DRAWING PLOT SIZE: ANSI F
C
A
B
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
1 2 3 4 5 6
E
D E
S C
R
IP
T
IO
N M
A R
K D
A T
E A
P P
R of Engineers
US Army Corps
/1
/2
BORDER VERSION UPDATE [08-2013]
S-001SHEET NAME:G2ECDJTH BY USERNAME:DATE AND TIME PLOTTED: 5/12/2017 1:18:54 PM
/0
/2
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
P O
R T
L A
N D
O R
E G
O N
P O
R T
L A
N D D
IS
T R
IC
PORTLAND DISTRICT
M
T T
H E
W D
H A
N S
O N P .E
A N
S I F
F L F .1
G -0
X X
X .d g n
G E
C D J T
H
A N
D P
H O
T O
S G
E N
E R
A L S
T R
U C
T U
R A
L N
O T
E S
G-003
:1
F
L L C
R E
E K D
A M A
N D R
E S
E R
V O
IR
FISH HORNS & TRASHRACKS AFTER DRAWDOWN - LOOKING WEST
E X
IS
T
IN
G F
IS
H H
O R
N S
T R
U C
T U
R E
S
W
N -1
-R -0
W
N -1
-C -0
G E
C D J T
H
FRAMES AND GRATING
FISH HORN VALVE BOX
TO BE REPLACED AND PAINTED (TYP)
SUPPORTS AND ATTACHMENTS
EXISTING STRUCTURAL
FISH HORNS AFTER DRAWDOWN - LOOKING NORTH
GENERAL NOTES:
P
IP
E L
IN
IN
G F
IS
H F
A C
IL
IT
Y W
A T
E R S
U P
P L
Y
9 EXISTING FISH HORNS
9 EXISTING TRASHRACKS
THE CONTRACTOR SHALL PROTECT THE FISH HORN VALVES AND THE EMERGENCY VALVES FROM CLEANING AND LINING OPERATIONS.8
FOR SECTIONS OF PIPE THAT ARE DISASSEMBLED, FOR ACCESS, NEW PIPE CONNECTION GASKETS MUST BE INSTALLED.7
SEE REFERENCE DRAWINGS FLD-2-8, FLD-2-9, FLD-2-12, FLD-2-13, FLD-2-32, FLD-2-35, FLD-2-36, FLD-2-37 FLD-3-1, AND FLD-3-2.6
NSTALL SPRAY-ON IN PLACE PIPE (SIPP) LINING ON EXISTING WATER SUPPLY LINES, PER SPECIFICATION 22 05 83.01 25.I5
ALL BOLTED CONNECTIONS SHALL BE FULLY PRE -TENSIONED WITH A-325 GALVANIZED BOLTS WITH APPROPRIATE NUTS AND WASHERS UNLESS INDICATED OTHERWISE.4
ANY DAMAGE TO THE FISH HORNS AS A RESULT OF THE PIPE LINING OPERATIONS SHALL BE REPAIRED AT THE CONTRACTOR'S COST.3
BOX GRATING, SEE INFO ONLY DWG: FLD-1-23/8. FOR FISH HORN VALVE BOX, SEE INFO ONLY DWG, FLD-2-22.
FOR FISH HORN STRUCTURES AND SUPPORTS, SEE INFO ONLY DWG: FLD-2-36-38, FLD-3-1 & 2. FOR TRASHRACK DETAILS, SEE INFO ONLY DWG, FLD-2-68. FOR FISH HORN VALVE 2
FOR LOCATION OF THE FISH HORNS, SEE SHEET G-002. FOR LOCATION OF FISH HORN VALVE VAULT BOX, SEE INFO ONLY DWG, FLD-2-8.1
G E
C D
M D
H
NTS
NTS
NTS
FISH HORN KNIFE GATE VALVES
NTS
FISH HORNS REMOVED FROM VALVE BOX
| Signed Cover Sheet |
| G-001 |
| FLF1 |
| G-003 |
| C-001 |
File details come from the government source that posted it. Updated .